{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T07:58:22Z","timestamp":1790409502445,"version":"4.1.0"},"reference-count":69,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T00:00:00Z","timestamp":1759881600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"JST Moonshot R&amp;D","award":["JPMJMS2021"],"award-info":[{"award-number":["JPMJMS2021"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Photoplethysmogram (PPG) signals are increasingly utilized in wearable and mobile healthcare applications due to their non-invasive nature and ease of use in measuring physiological parameters, such as heart rate, blood pressure, and oxygen saturation. Recent advancements have highlighted green-light photoplethysmogram (gPPG) as offering superior signal quality and accuracy compared to traditional red-light photoplethysmogram (rPPG). Given the deterministic chaotic nature of PPG signals\u2019 dynamics, nonlinear time series analysis has emerged as a powerful method for extracting health-related information not captured by conventional linear techniques. However, optimal data conditions, including appropriate sampling frequency and minimum required time series length for effective nonlinear analysis, remain insufficiently investigated. This study examines the impact of downsampling frequencies and reducing time series lengths on the accuracy of estimating dynamical characteristics from gPPG and rPPG signals. Results demonstrate that a sampling frequency of 200 Hz provides an optimal balance, maintaining robust correlations in dynamical indices while reducing computational load. Furthermore, analysis of varying time series lengths revealed that the dynamical properties stabilize sufficiently at around 170 s, achieving an error of less than 5%. A comparative analysis between gPPG and rPPG revealed no significant statistical differences, confirming their similar effectiveness in estimating dynamical properties under controlled conditions. These results enhance the reliability and applicability of PPG-based health monitoring technologies.<\/jats:p>","DOI":"10.3390\/s25196232","type":"journal-article","created":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T12:04:52Z","timestamp":1759925092000},"page":"6232","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Data Reduction Methodology for Dynamic Characteristic Extraction in Photoplethysmogram"],"prefix":"10.3390","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5850-0604","authenticated-orcid":false,"given":"Nina","family":"Sviridova","sequence":"first","affiliation":[{"name":"Department of Intelligent Systems, Tokyo City University, 1-28-1 Tamazutsumi, Setagaya-ku, Tokyo 158-8557, Japan"},{"name":"International Research Center for Neurointelligence, The University of Tokyo, 7-3-1 Hongo Bunkyo-ku, Tokyo 113-0033, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sora","family":"Okazaki","sequence":"additional","affiliation":[{"name":"Department of Intelligent Systems, Tokyo City University, 1-28-1 Tamazutsumi, Setagaya-ku, Tokyo 158-8557, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,10,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Park, J., Seok, H.S., Kim, S.-S., and Shin, H. (2022). Photoplethysmogram Analysis and Applications: An Integrative Review. Front. Physiol., 12.","DOI":"10.3389\/fphys.2021.808451"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Kim, K.B., and Baek, H.J. (2023). Photoplethysmography in Wearable Devices: A Comprehensive Review of Technological Advances, Current Challenges, and Future Directions. Electronics, 12.","DOI":"10.3390\/electronics12132923"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Namvari, M., Lipoth, J., Knight, S., Jamali, A.A., Hedayati, M., Spiteri, R.J., and Syed-Abdul, S. (2022). Photoplethysmography Enabled Wearable Devices and Stress Detection: A Scoping Review. J. Pers. Med., 12.","DOI":"10.3390\/jpm12111792"},{"key":"ref_4","unstructured":"Kyriacou, P.A., and Allen, J. (2021). Photoplethysmography, Academic Press. [1st ed.]."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/28\/3\/R01","article-title":"Photoplethysmography and Its Application in Clinical Physiological Measurement","volume":"28","author":"Allen","year":"2007","journal-title":"Physiol. Meas."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Maeda, Y., Sekine, M., Tamura, T., Moriya, A., Suzuki, T., and Kameyama, K. (2008, January 20\u201325). Comparison of Reflected Green Light and Infrared Photoplethysmography. Proceedings of the 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, BC, Canada.","DOI":"10.1109\/IEMBS.2008.4649649"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/s13534-019-00097-w","article-title":"Current Progress of Photoplethysmography and SPO2 for Health Monitoring","volume":"9","author":"Tamura","year":"2019","journal-title":"Biomed. Eng. Lett."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Lee, S., Shin, H., and Hahm, C. (February, January 31). Effective PPG Sensor Placement for Reflected Red and Green Light, and Infrared Wristband-Type Photoplethysmography. Proceedings of the 2016 18th International Conference on Advanced Communication Technology (ICACT), Pyeongchang, Republic of Korea.","DOI":"10.1109\/ICACT.2016.7423470"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1007\/s10916-010-9506-z","article-title":"The Advantages of Wearable Green Reflected Photoplethysmography","volume":"35","author":"Maeda","year":"2011","journal-title":"J. Med. Syst."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"282","DOI":"10.3390\/electronics3020282","article-title":"Wearable Photoplethysmographic Sensors\u2014Past and Present","volume":"3","author":"Tamura","year":"2014","journal-title":"Electronics"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.chaos.2018.09.016","article-title":"Photoplethysmogram at Green Light: Where Does Chaos Arise From?","volume":"116","author":"Sviridova","year":"2018","journal-title":"Chaos Solitons Fractals"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.bspc.2008.07.001","article-title":"Three-Section Transmission-Line Arterial Model for Noninvasive Assessment of Vascular Remodeling in Primary Hypertension","volume":"4","author":"Filho","year":"2009","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1007\/s10877-015-9669-8","article-title":"Photoplethysmography Variability as an Alternative Approach to Obtain Heart Rate Variability Information in Chronic Pain Patient","volume":"29","author":"Chuang","year":"2015","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1088\/0967-3334\/31\/9\/015","article-title":"Photoplethysmography Pulse Rate Variability as a Surrogate Measurement of Heart Rate Variability during Non-Stationary Conditions","volume":"31","author":"Gil","year":"2010","journal-title":"Physiol. Meas."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Fujita, D., Suzuki, A., and Ryu, K. (2019). PPG-Based Systolic Blood Pressure Estimation Method Using PLS and Level-Crossing Feature. Appl. Sci., 9.","DOI":"10.3390\/app9020304"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Rubins, U., Grabovskis, A., Grube, J., and Kukulis, I. (2008, January 16\u201320). Photoplethysmography Analysis of Artery Properties in Patients with Cardiovascular Diseases. Proceedings of the 14th Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, Riga, Latvia.","DOI":"10.1007\/978-3-540-69367-3_85"},{"key":"ref_17","unstructured":"Wright, G., and Caceres, J.L.H. (2017). Extracting Clinically Relevant Information from Pulse Oximetry Traces. J. Health Inform. Afr., 4."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Sharma, M., Rajput, J.S., Tan, R.S., and Acharya, U.R. (2021). Automated Detection of Hypertension Using Physiological Signals: A Review. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph18115838"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Nakagome, K., Makinodan, M., Uratani, M., Kato, M., Ozaki, N., Miyata, S., Iwamoto, K., Hashimoto, N., Toyomaki, A., and Mishima, K. (2023). Feasibility of a Wrist-Worn Wearable Device for Estimating Mental Health Status in Patients with Mental Illness. Front. Psychiatry, 14.","DOI":"10.3389\/fpsyt.2023.1189765"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"21232","DOI":"10.1109\/JSEN.2022.3208427","article-title":"A Novel Rapid Assessment of Mental Stress by Using PPG Signals Based on Deep Learning","volume":"22","author":"Wang","year":"2022","journal-title":"IEEE Sens. J."},{"key":"ref_21","first-page":"27","article-title":"Technology development and the prospect of chaos analysis through pulse waves: The potential for the applied development of the correspondence method to mental illness in China","volume":"40","author":"Hu","year":"2014","journal-title":"Bull. Grad. Sch. Hum. Sci. Osaka Univ."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1007\/s11571-024-10090-4","article-title":"Linear and Nonlinear Analysis of Multimodal Physiological Data for Affective Arousal Recognition","volume":"18","author":"Khaleghi","year":"2024","journal-title":"Cogn. Neurodyn."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1152\/jappl.1999.86.1.359","article-title":"Is Breathing in Infants Chaotic? Dimension Estimates for Respiratory Patterns during Quiet Sleep","volume":"86","author":"Small","year":"1999","journal-title":"J. Appl. Physiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1038\/39043","article-title":"Decrease of Cardiac Chaos in Congestive Heart Failure","volume":"389","author":"Poon","year":"1997","journal-title":"Nature"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.chaos.2015.05.005","article-title":"Human Photoplethysmogram: New Insight into Chaotic Characteristics","volume":"77","author":"Sviridova","year":"2015","journal-title":"Chaos Solitons Fractals"},{"key":"ref_26","first-page":"1","article-title":"Chaotic Pulsation in Human Capillary Vessels and Its Dependence on the Mental and Physical Conditions","volume":"4","author":"Tsuda","year":"1992","journal-title":"Proc. Annu. Meet. Biomed. Fuzzy Syst. Assoc. BMFSA"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2245","DOI":"10.1142\/S0218127400001407","article-title":"Mental Conditions Reflected by the Chaos of Pulsation in Capillary Vessels","volume":"10","author":"Sumida","year":"2000","journal-title":"Int. J. Bifurc. Chaos"},{"key":"ref_28","unstructured":"Strogatz, S. (2014). Nonlinear Dynamics and Chaos: With Applications to Physics, Biology, Chemistry, and Engineering, CRC Press. [3rd ed.]."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Shelhamer, M. (2006). Nonlinear Dynamics in Physiology: A State-Space Approach, WORLD SCIENTIFIC.","DOI":"10.1142\/9789812772794"},{"key":"ref_30","first-page":"141","article-title":"Towards Understanding of Photoplethysmogram Dynamics through Nonlinear Time Series Analysis","volume":"71","author":"Sviridova","year":"2019","journal-title":"Seisan Kenkyu"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.physrep.2006.11.001","article-title":"Recurrence Plots for the Analysis of Complex Systems","volume":"438","author":"Marwan","year":"2007","journal-title":"Phys. Rep."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1152\/jappl.1994.76.2.965","article-title":"Dynamical Assessment of Physiological Systems and States Using Recurrence Plot Strategies","volume":"76","author":"Webber","year":"1994","journal-title":"J. Appl. Physiol."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Webber, C.L., and Marwan, N. (2015). Recurrence Quantification Analysis: Theory and Best Practices, Springer International Publishing. Understanding Complex Systems.","DOI":"10.1007\/978-3-319-07155-8"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"e0203","DOI":"10.15275\/rusomj.2024.0203","article-title":"Cross-Recurrence Quantification Of Cardiovascular Signals In Newborns Is A Sensitive Marker Of Health Status","volume":"13","author":"Skazkina","year":"2024","journal-title":"Russ. Open Med J."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Hamedani, N.E., Sadredini, S.Z., and Khodabakhshi, M.B. (2021, January 25\u201326). A CNN Model for Cuffless Blood Pressure Estimation from Nonlinear Characteristics of PPG Signals. Proceedings of the 2021 28th National and 6th International Iranian Conference on Biomedical Engineering (ICBME), Tehran, Iran.","DOI":"10.1109\/ICBME54433.2021.9750332"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Alotaiby, T.N., Alshebeili, S.A., Alotibi, G., and Alotaibi, G.N. (2022, January 24\u201326). Recurrence Quantification Analysis for PPG\/ECG-Based Subject Authentication|IEEE Conference Publication|IEEE Xplore. Proceedings of the 2022 4th International Conference on Data Intelligence and Security (ICDIS), Shenzhen, China.","DOI":"10.1109\/ICDIS55630.2022.00051"},{"key":"ref_37","first-page":"56","article-title":"Application of Recurrence Quantification Analysis to Hypertension Photoplethysmograms","volume":"74","author":"Sviridova","year":"2020","journal-title":"IEICE Proc. Ser."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Mej\u00eda-Mej\u00eda, E., May, J.M., Elgendi, M., and Kyriacou, P.A. (2021). Classification of Blood Pressure in Critically Ill Patients Using Photoplethysmography and Machine Learning. Comput. Methods Programs Biomed., 208.","DOI":"10.1016\/j.cmpb.2021.106222"},{"key":"ref_39","first-page":"43","article-title":"Nonlinear Time Series Analysis: 1. A New Method of Analysis and the Theoretical Background","volume":"158","author":"Ohtomo","year":"1992","journal-title":"Bull. Fac. Eng. Hokkaido Univ."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1142\/S0218127411029008","article-title":"HOW TO AVOID POTENTIAL PITFALLS IN RECURRENCE PLOT BASED DATA ANALYSIS","volume":"21","author":"Marwan","year":"2011","journal-title":"Int. J. Bifurc. Chaos"},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Sviridova, N., Zhao, T., Nakano, A., and Ikeguchi, T. (2022). Photoplethysmogram Recording Length: Defining Minimal Length Requirement from Dynamical Characteristics. Sensors, 22.","DOI":"10.20944\/preprints202206.0131.v1"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2300527","DOI":"10.1002\/aisy.202300527","article-title":"A System-Level Feasibility Study of a Lead-Free Ultrasonically Powered Light Delivery Implant for Optogenetics","volume":"6","author":"Laursen","year":"2024","journal-title":"Adv. Intell. Syst."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Lu, H., Yuan, G., Zhang, J., and Liu, G. (2020). Recognition of Impulse of Love at First Sight Based On Photoplethysmography Signal. Sensors, 20.","DOI":"10.3390\/s20226572"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1007\/s10877-020-00470-6","article-title":"Photoplethysmography-Derived Approximate Entropy and Sample Entropy as Measures of Analgesia Depth during Propofol\u2013Remifentanil Anesthesia","volume":"35","author":"Chen","year":"2021","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Imanishi, A., and Oyama-Higa, M. (2007, January 7\u201310). On the Largest Lyapunov Exponents of Finger Plethysmogram and Heart Rate under Anxiety, Fear, and Relief States. Proceedings of the 2007 IEEE International Conference on Systems, Man and Cybernetics, Montreal, QC, Canada.","DOI":"10.1109\/ICSMC.2007.4413829"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Zhao, X., and Sun, G. (2021). A Multi-Class Automatic Sleep Staging Method Based on Photoplethysmography Signals. Entropy, 23.","DOI":"10.3390\/e23010116"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"14185","DOI":"10.1109\/JSEN.2022.3180893","article-title":"A 186\u03bcW Photoplethysmography-Based Noninvasive Glucose Sensing SoC","volume":"22","author":"Hina","year":"2022","journal-title":"IEEE Sens. J."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/j.chaos.2018.07.035","article-title":"Poincar\u00e9\u2019s Section Analysis for PPG-Based Automatic Emotion Recognition","volume":"114","author":"Goshvarpour","year":"2018","journal-title":"Chaos Solitons Fractals"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Shi, P., Xu, Y., Guo, M., and Yu, H. (2017, January 14\u201316). Heart Rate Variability for Assessment of Fatigue of Central Motor Control in a Rhythmical Finger Tapping Task. Proceedings of the 2017 10th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI), Shanghai, China.","DOI":"10.1109\/CISP-BMEI.2017.8302222"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s12046-019-1118-9","article-title":"Estimation of Blood Glucose by Non-Invasive Method Using Photoplethysmography","volume":"44","author":"Habbu","year":"2019","journal-title":"S\u0101dhan\u0101"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Li, N., Yu, J., Mao, X., Zhao, Y., and Huang, L. (2023). The Nonlinearity Properties of Pulse Signal of Pregnancy in the Three Trimesters. Biomed. Signal Process. Control, 79.","DOI":"10.1016\/j.bspc.2022.104158"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Vraka, A., Hornero, F., F\u00e1cila, L., Ravelli, F., Alcaraz, R., and Rieta, J.J. (2024). Harnessing Photoplethysmography and Deep Learning in Continuous Blood Pressure Monitoring for Early Hypertension Detection. Advances in Digital Health and Medical Bioengineering, Springer.","DOI":"10.1007\/978-3-031-62520-6_25"},{"key":"ref_53","first-page":"313","article-title":"Application of Photoplethysmogram for Detecting Physiological Effects of Tractor Noise","volume":"8","author":"Sviridova","year":"2015","journal-title":"Eng. Agric. Environ. Food"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Miao, T., Ogura, Y., Fujita, E., and Oyama-Higa, M. (2008, January 12\u201315). Fluctuation Analysis of Finger Plethysmograms Related to Various Conditions. Proceedings of the 2008 IEEE International Conference on Systems, Man and Cybernetics, Singapore.","DOI":"10.1109\/ICSMC.2008.4811811"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Xing, X., Dong, W.-F., Xiao, R., Song, M., and Jiang, C. (2023). Analysis of the Chaotic Component of Photoplethysmography and Its Association with Hemodynamic Parameters. Entropy, 25.","DOI":"10.3390\/e25121582"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Wu, S., Chen, M., Wei, K., and Liu, G. (2021). Sleep Apnea Screening Based on Photoplethysmography Data from Wearable Bracelets Using an Information-Based Similarity Approach. Comput. Methods Programs Biomed., 211.","DOI":"10.1016\/j.cmpb.2021.106442"},{"key":"ref_57","unstructured":"(2025, August 01). Pulse Sensor|Electronics Basics|ROHM. Available online: https:\/\/www.rohm.com\/electronics-basics\/sensors\/sensor_what3."},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Gitman, Y., and Murphy, J. (2023). Heartbeat Sensor Projects with PulseSensor: Prototyping Devices with Biofeedback, Apress.","DOI":"10.1007\/978-1-4842-9325-6"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"351","DOI":"10.7326\/M17-3203","article-title":"Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: Synopsis of the 2017 American College of Cardiology\/American Heart Association Hypertension Guideline","volume":"168","author":"Carey","year":"2018","journal-title":"Ann. Intern. Med."},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"B\u00e9res, S., and Hejjel, L. (2021). The Minimal Sampling Frequency of the Photoplethysmogram for Accurate Pulse Rate Variability Parameters in Healthy Volunteers. Biomed. Signal Process. Control, 68.","DOI":"10.1016\/j.bspc.2021.102589"},{"key":"ref_61","unstructured":"(2024, December 10). Scipy.Signal.Butter\u2014SciPy v1.7.1 Manual. Available online: https:\/\/docs.scipy.org\/doc\/\/scipy-1.7.1\/reference\/reference\/generated\/scipy.signal.butter.html."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"180076","DOI":"10.1038\/sdata.2018.76","article-title":"An Optimal Filter for Short Photoplethysmogram Signals","volume":"5","author":"Liang","year":"2018","journal-title":"Sci. Data"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1867","DOI":"10.1109\/TBME.2009.2039568","article-title":"Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data","volume":"57","author":"Krishnan","year":"2010","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_64","doi-asserted-by":"crossref","unstructured":"Elgendi, M. (2016). Optimal Signal Quality Index for Photoplethysmogram Signals. Bioengineering, 3.","DOI":"10.3390\/bioengineering3040021"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"105","DOI":"10.5136\/lifesupport.22.105","article-title":"Study of Mental Stress Evaluation based on analysis of Heart Rate Variability","volume":"22","author":"Matsumoto","year":"2010","journal-title":"J. Life Support Eng."},{"key":"ref_66","unstructured":"Rubenstein, D.A., Yin, W., and Frame, M.D. (2021). Biofluid Mechanics. An Introduction to Fluid Mechanics, Macrocirculation, and Microcirculation, Academic Press. Biomedical Engineering."},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Ni, Z., Sun, F., and Li, Y. (2022). Heart Rate Variability-Based Subjective Physical Fatigue Assessment. Sensors, 22.","DOI":"10.3390\/s22093199"},{"key":"ref_68","unstructured":"Kuratsune, H., Tajima, S., Koizumi, J., Nishizawa, Y., Watanabe, Y., and Kataoka, Y. (2010). Fatigue Level Determination Processing System (\u75b2\u52b4\u5ea6\u306e\u5224\u5b9a\u51e6\u7406\u30b7\u30b9\u30c6\u30e0)|\u7279\u8a31\u60c5\u5831|J-GLOBAL \u79d1\u5b66\u6280\u8853\u7dcf\u5408\u30ea\u30f3\u30af\u30bb\u30f3\u30bf\u30fc 2010. (2010-201113), Japan Patent, (In Japanese)."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1007\/BF01053745","article-title":"Embedology","volume":"65","author":"Sauer","year":"1991","journal-title":"J. Stat. Phys"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/19\/6232\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:50:30Z","timestamp":1760035830000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/19\/6232"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,8]]},"references-count":69,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2025,10]]}},"alternative-id":["s25196232"],"URL":"https:\/\/doi.org\/10.3390\/s25196232","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,8]]}}}