{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T14:45:26Z","timestamp":1781707526021,"version":"3.54.5"},"reference-count":61,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T00:00:00Z","timestamp":1770249600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>High-intensity interval training (HIIT) provides substantial cardiovascular benefits; however, precise monitoring typically requires expensive devices. These systems are feasible in research laboratories but are costly for schools and the fitness industry. Low-cost, validated devices are required to facilitate broader implementation. A cross-sectional study was conducted with 213 students (173 men and 40 women) from the Catholic University of Valencia, Spain. The participants completed an HIIT protocol consisting of five 3 min blocks. Heart rate (HR) was recorded using a Moofit HW401 armband (ANT+ technology). Ratings of perceived exertion (RPE, Omni-Res scale) and the Wint index were also obtained. Pearson correlations were computed between reserve heart rate (HRr), RPE, and Wint index during the warm-up phases (T1, T2) and HIIT, stratified by sex, age, and body mass index (BMI). HRr was strongly correlated with the Wint index (r = 0.95, p &lt; 0.0001) and moderately correlated with RPE (r = 0.235, p = 0.001). No significant sex differences were observed (men 83.66 \u00b1 8.18% vs. women 82.31 \u00b1 10.89%; p &gt; 0.05). Correlations were weaker in participants with extreme BMI values (n &lt; 10, obese). The Moofit HW401 armband showed consistent agreement between HRr, RPE, and Wint index during HIIT, supporting its practical use for group monitoring in educational settings, pending formal validation against gold standards.<\/jats:p>","DOI":"10.3390\/s26031049","type":"journal-article","created":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T15:24:19Z","timestamp":1770305059000},"page":"1049","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Agreement Between Reserve Heart Rate, Perceived Exertion and Wint Index During HIIT Using a Low-Cost ANT+ Armband in University Students"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5089-8427","authenticated-orcid":false,"given":"Julio","family":"Mart\u00edn-Ruiz","sequence":"first","affiliation":[{"name":"Department of Health and Functional Assessment, Catholic University of Valencia, 46900 Valencia, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0565-3329","authenticated-orcid":false,"given":"Laura","family":"Ruiz-Sanchis","sequence":"additional","affiliation":[{"name":"Department of Sports Management and Physical Activity, Catholic University of Valencia, 46900 Valencia, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,2,5]]},"reference":[{"key":"ref_1","unstructured":"L\u00f3pez-Chicharro, J., and Vicente-Campos, D. (2018). HIIT Entrenamiento Interv\u00e1lico de Alta Intensidad, Exercise Physiology and Tranining."},{"key":"ref_2","first-page":"65","article-title":"M\u00e9todo HITT: Una herramienta para el fortalecimiento de la condici\u00f3n f\u00edsica en adolescentes","volume":"5","author":"Moreno","year":"2021","journal-title":"Rev. Conecta Libertad"},{"key":"ref_3","first-page":"1","article-title":"Effect of individual characteristics and aerobic training on the %HRR-%VO2R relationship","volume":"23","author":"Sisti","year":"2022","journal-title":"Eur. J. Sport Sci."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1519\/JSC.0000000000002079","article-title":"Relationship Between Percentages of Heart Rate Reserve and Oxygen Uptake Reserve During Cycling and Running: A Validation Study","volume":"33","author":"Farinatti","year":"2019","journal-title":"J. Strength Cond. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1123\/ijspp.2016-0062","article-title":"Ecological Validity of the Session Rating of Perceived Exertion for Quantifying Internal Training Load in Fencing","volume":"12","author":"Turner","year":"2017","journal-title":"Int. J. Sports Physiol. Perform."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.jadohealth.2024.09.017","article-title":"Effects of Exercise Interventions on Blood Pressure in Children and Adolescents with Overweight or Obesity: A Systematic Review and Meta-Analysis of Randomized Controlled Trials","volume":"76","author":"Zhou","year":"2025","journal-title":"J. Adolesc. Health"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Ko, J., So, W., and Park, S. (2025). Narrative Review of High-Intensity Interval Training: Positive Impacts on Cardiovascular Health and Disease Prevention. J. Cardiovasc. Dev. Dis., 12.","DOI":"10.3390\/jcdd12040158"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.1002\/ehf2.15225","article-title":"Training-induced change of diastolic function in heart failure with preserved ejection fraction","volume":"12","author":"Gevaert","year":"2025","journal-title":"ESC Heart Fail."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1093\/eurjpc\/zwae332","article-title":"Comparison of exercise training modalities and change in peak oxygen consumption in heart failure with preserved ejection fraction: A secondary analysis of the OptimEx-Clin trial","volume":"32","author":"Mueller","year":"2025","journal-title":"Eur. J. Prev. Cardiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"793","DOI":"10.47197\/retos.v37i37.67809","article-title":"M\u00e9todos de evaluaci\u00f3n del equilibrio est\u00e1tico y din\u00e1mico en ni\u00f1os de 8 a 12 a\u00f1os (Evaluation methods of static and dynamic balance in children aged 8 to 12 years old)","volume":"37","year":"2020","journal-title":"Retos"},{"key":"ref_11","first-page":"57","article-title":"Biomec\u00e1nica y Bases Neuromusculares de La Actividad F\u00edsica y El Deporte","volume":"5","author":"Izquierdo","year":"2010","journal-title":"Cult. Cienc. Deporte"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/S0749-3797(99)00056-2","article-title":"Correlates of objectively measured physical activity in preadolescent youth","volume":"17","author":"Trost","year":"1999","journal-title":"Am. J. Prev. Med."},{"key":"ref_13","first-page":"17","article-title":"Accelerometer assessment of physical activity in active, healthy older adults","volume":"17","author":"Copeland","year":"2009","journal-title":"J. Aging Phys. Act."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1086\/589815","article-title":"Accelerometry to Estimate Energy Expenditure during Activity: Best Practice with Data Loggers","volume":"82","author":"Halsey","year":"2009","journal-title":"Physiol. Biochem. Zool."},{"key":"ref_15","first-page":"CD013591","article-title":"Mobile health (m-health) smartphone interventions for adolescents and adults with overweight or obesity","volume":"2","author":"Metzendorf","year":"2024","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1007\/s10916-024-02091-x","article-title":"Mobile Apps for Wound Assessment and Monitoring: Limitations, Advancements and Opportunities","volume":"48","author":"Kabir","year":"2024","journal-title":"J. Med. Syst."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Bucher, S.L., Young, A., Dolan, M., Padmanaban, G.P., Chandnani, K., and Purkayastha, S. (2023). The NeoRoo mobile app: Initial design and prototyping of an Android-based digital health tool to support Kangaroo Mother Care in low\/middle-income countries (LMICs). PLoS Digit. Health, 2.","DOI":"10.1371\/journal.pdig.0000216"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e43186","DOI":"10.2196\/43186","article-title":"Design Guidelines of Mobile Apps for Older Adults: Systematic Review and Thematic Analysis","volume":"11","author":"Ferre","year":"2023","journal-title":"JMIR mHealth uHealth"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Seo, M. (2024). Acute Response of Different High-Intensity Interval Training Protocols on Cardiac Auto-Regulation Using Wearable Device. Sensors, 24.","DOI":"10.3390\/s24144758"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1002\/pmrj.12424","article-title":"Accuracy of Wearable Devices for Measuring Heart Rate During Conventional and Nordic Walking","volume":"13","author":"Baek","year":"2021","journal-title":"PM&R"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1186\/s12984-024-01440-8","article-title":"Feedback control of heart rate during robotics-assisted tilt table exercise in patients after stroke: A clinical feasibility study","volume":"21","author":"Brockmann","year":"2024","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1007\/s13246-021-01003-4","article-title":"A new approach to HR monitoring using photoplethysmographic signals during intensive physical exercise","volume":"44","author":"Chen","year":"2021","journal-title":"Phys. Eng. Sci. Med."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Bonneval, L., Wing, D., Sharp, S., Tristao Parra, M., Moran, R., LaCroix, A., and Godino, J. (2025). Validity of Heart Rate Variability Measured with Apple Watch Series 6 Compared to Laboratory Measures. Sensors, 25.","DOI":"10.3390\/s25082380"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"e54871","DOI":"10.2196\/54871","article-title":"Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study","volume":"13","author":"Ceugniez","year":"2025","journal-title":"JMIR mHealth uHealth"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Rogers, B., Giles, D., Draper, N., Mourot, L., and Gronwald, T. (2021). Detection of the Anaerobic Threshold in Endurance Sports: Validation of a New Method Using Correlation Properties of Heart Rate Variability. J. Funct. Morphol. Kinesiol., 6.","DOI":"10.3390\/jfmk6020038"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Zimatore, G., Falcioni, L., Gallotta, M.C., Bonavolont\u00e0, V., Campanella, M., De Spirito, M., Guidetti, L., and Baldari, C. (2021). Recurrence quantification analysis of heart rate variability to detect both ventilatory thresholds. PLoS ONE, 16.","DOI":"10.1371\/journal.pone.0249504"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Mehmood, N.Q., and Culmone, R. (2015, January 24\u201327). An ANT protocol based health care system. Proceedings of the 2015 IEEE 29th International Conference on Advanced Information Networking and Applications Workshops, Gwangju, Republic of Korea.","DOI":"10.1109\/WAINA.2015.45"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Weghorn, H. (2015). Usability and Engineering Aspects of Competing RF Technologies for Communication with Commercial Sports Sensors in Ubiquitous Applications-Experimental Comparison of Power Consumption and Use Cases for ANT and Bluetooth Low Energy Sensor Devices. Proceedings of the 3rd International Congress on Sport Sciences Research and Technology Support (icSPORTS 2015), Lisbon, Portugal, 15\u201317 November 2015, SciTePress.","DOI":"10.5220\/0005643502630270"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"3651591","DOI":"10.1155\/2016\/3651591","article-title":"A flexible and scalable architecture for real-time ANT sensor data acquisition and NoSQL storage","volume":"12","author":"Mehmood","year":"2016","journal-title":"Int. J. Distrib. Sens. Netw."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"645781","DOI":"10.1155\/2015\/645781","article-title":"An experimental performance evaluation and compatibility study of the Bluetooth low energy based platform for ECG monitoring in WBANs","volume":"11","author":"Touati","year":"2015","journal-title":"Int. J. Distrib. Sens. Netw."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1002\/ejsc.12115","article-title":"Monitoring fatigue state with heart rate-based and subjective methods during intensified training in recreational runners","volume":"24","author":"Nuuttila","year":"2024","journal-title":"Eur. J. Sport Sci."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s40279-023-01948-4","article-title":"Sports Heart Monitors as Reliable Diagnostic Tools for Training Control and Detecting Arrhythmias in Professional and Leisure-Time Endurance Athletes: An Expert Consensus Statement","volume":"54","author":"Gajda","year":"2024","journal-title":"Sports Med."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Alamar, B. (2024). Sports Analytics: A Guide for Coaches, Managers, and Other Decision Makers, Columbia University Press.","DOI":"10.7312\/alam20520"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"775","DOI":"10.47197\/retos.v47.94795","article-title":"Relaci\u00f3n entre el nivel de actividad f\u00edsica y el rendimiento acad\u00e9mico en estudiantes de una instituci\u00f3n universitaria. Estudio multic\u00e9ntrico. (Relationship between the level of physical activity and the academic performance in students at a university institution. Multicentric Study)","volume":"47","author":"Bedoya","year":"2023","journal-title":"Retos"},{"key":"ref_35","first-page":"116","article-title":"Valoraci\u00f3n del nivel de actividad f\u00edsica y aptitud f\u00edsica en una muestra de universitarios: Comparativa tras la pandemia de COVID-19","volume":"11","author":"Molero","year":"2022","journal-title":"RICCAFD Rev. Iberoam. Cienc. Act. F\u00eds. Deporte"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"41","DOI":"10.21830\/23460628.108","article-title":"Efectos de un programa f\u00edsico en el componente motriz valorado a partir del cribado de movimiento funcional (FMS) en estudiantes universitarios","volume":"10","author":"Bustamante","year":"2022","journal-title":"Br\u00fajula Semill. Investig."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"e34","DOI":"10.2196\/mhealth.7043","article-title":"Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable Devices","volume":"5","author":"Dooley","year":"2017","journal-title":"JMIR mHealth uHealth"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"e10893","DOI":"10.7717\/peerj.10893","article-title":"Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities","volume":"9","author":"Shumate","year":"2021","journal-title":"PeerJ"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1697","DOI":"10.1249\/MSS.0000000000001284","article-title":"Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise","volume":"49","author":"Gillinov","year":"2017","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Saucedo-Araujo, R.G., Huertas-Delgado, F.J., Barranco-Ruiz, Y.M., Perez-Lopez, I.J., Aznar-Lain, S., Chillon, P., and Herrador-Colmenero, M. (2022). Testing the Mystic School Mobile Application to Promote Active Commuting to School in Spanish Adolescents: The PACO Study. Children, 9.","DOI":"10.3390\/children9121997"},{"key":"ref_41","unstructured":"Monteagudo Chiner, P., Capella-Peris, C., Beltran-Garrido, J.V., and Hernando, C. (2023). Percepci\u00f3n, satisfacci\u00f3n y desarrollo de competencias relacionadas con la valoraci\u00f3n condicional: Una cuesti\u00f3n relevante para el alumnado de Ciencias de la Actividad F\u00edsica y el Deporte. Nuevos Caminos en las Pr\u00e1cticas Innovadoras Docentes del Ecosistema Educativo, Dykinson."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1249\/01.MSS.0000048831.15016.2A","article-title":"Concurrent validation of the OMNI perceived exertion scale for resistance exercise","volume":"35","author":"Robertson","year":"2003","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"73","DOI":"10.2478\/hukin-2013-0047","article-title":"Mechanical work and long-distance performance prediction: The influence of allometric scaling","volume":"38","author":"Tartaruga","year":"2013","journal-title":"J. Hum. Kinet."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1242\/jeb.195.1.211","article-title":"Mechanical determinants of the minimum energy cost of gradient running in humans","volume":"195","author":"Minetti","year":"1994","journal-title":"J. Exp. Biol."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1139\/h2012-105","article-title":"Is maximal lactate steady state during intermittent cycling different for active compared with passive recovery?","volume":"37","author":"Greco","year":"2012","journal-title":"Appl. Physiol. Nutr. Metab."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"1911","DOI":"10.1007\/s00421-016-3443-6","article-title":"Mechanical work and efficiency of 5 + 5 m shuttle running","volume":"116","author":"Zamparo","year":"2016","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Yamaner, E., Tur\u011fut, T., Aksoy, A., Demirk\u0131ran, B., U\u00e7ar, M.A., Ba\u015fo\u011flu, B., \u00c7ami\u00e7i, F., Yanar, M.S., B\u00fclb\u00fcl, A., and Ko\u00e7, A.F. (2025). Impact of an 8-week high-intensity bodyweight interval training on body composition and blood lipid metabolism in young women with overweight. Front. Public Health, 13.","DOI":"10.3389\/fpubh.2025.1578569"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1080\/02701367.2022.2042463","article-title":"Influence of HIIRT With Fixed and Self-Selected Recovery Intervals on Physiological, Affective, and Enjoyment Responses","volume":"94","author":"Fidalgo","year":"2023","journal-title":"Res. Q. Exerc. Sport"},{"key":"ref_49","unstructured":"R Core Team (2022). R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing."},{"key":"ref_50","unstructured":"Kassambara, A. (2020). Ggpubr: \u201cggplot2\u201d Based Publication Ready Plots, Datanovia. R Package Version 0.4.0."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s40279-023-01938-6","article-title":"A Perspective on High-Intensity Interval Training for Performance and Health","volume":"53","author":"Coates","year":"2023","journal-title":"Sports Med."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1097\/00008483-199707000-00007","article-title":"Validity of rating of perceived exertion during graded exercise testing in apparently healthy adults and cardiac patients","volume":"17","author":"Whaley","year":"1997","journal-title":"J. Cardiopulm. Rehabil."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1123\/ijspp.2018-0637","article-title":"Comparison of RPE (Rating of Perceived Exertion) Scales for Session RPE","volume":"14","author":"Arney","year":"2019","journal-title":"Int. J. Sports Physiol. Perform."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"93","DOI":"10.2478\/hukin-2013-0072","article-title":"Exercise Intensity and Validity of the Ratings of Perceived Exertion (Borg and OMNI Scales) in an Indoor Cycling Session","volume":"39","author":"Muyor","year":"2013","journal-title":"J. Hum. Kinet."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1249\/MSS.0b013e318213fefb","article-title":"Quantity and quality of exercise for developing and maintaining cardiorespiratory, musculoskeletal, and neuromotor fitness in apparently healthy adults: Guidance for prescribing exercise","volume":"43","author":"Garber","year":"2011","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1016\/j.numecd.2013.06.002","article-title":"Is high-intensity exercise better than moderate-intensity exercise for weight loss?","volume":"23","year":"2013","journal-title":"Nutr. Metab. Cardiovasc. Dis."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1007\/s12017-020-08638-8","article-title":"High-Intensity Functional Training: Molecular Mechanisms and Benefits","volume":"23","author":"Okun","year":"2021","journal-title":"Neuromolecular Med."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"jrm00387","DOI":"10.2340\/jrm.v55.4523","article-title":"Relationship Between Heart Rate and Perceived Exertion in Neuromuscular Diseases: How do Laboratory-Based Exercise Testing Results Translate to Home-Based Aerobic Training Sessions?","volume":"55","author":"Voorn","year":"2023","journal-title":"J. Rehabil. Med."},{"key":"ref_59","first-page":"29","article-title":"Relationships between rating of perceived exertion, heart rate and blood lactate during continuous and alternated-intensity cycling exercises","volume":"35","author":"Zinoubi","year":"2018","journal-title":"Biol. Sport"},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"Kim, K.B., and Baek, H.J. (2023). Photoplethysmography in Wearable Devices: A Comprehensive Review of Technological Advances, Current Challenges, and Future Directions. Electronics, 12.","DOI":"10.3390\/electronics12132923"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1136\/bjsports-2020-103148","article-title":"Recommendations for determining the validity of consumer wearable heart rate devices: Expert statement and checklist of the INTERLIVE Network","volume":"55","author":"Stang","year":"2021","journal-title":"Br. J. Sports Med."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/3\/1049\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T05:10:43Z","timestamp":1770613843000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/3\/1049"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,5]]},"references-count":61,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["s26031049"],"URL":"https:\/\/doi.org\/10.3390\/s26031049","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,5]]}}}