{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:28:43Z","timestamp":1793726923267,"version":"4.6.1"},"reference-count":20,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T00:00:00Z","timestamp":1777334400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Smart insoles equipped with pressure sensor matrices are increasingly used for gait analysis, yet high-density arrays compromise battery life and data throughput. This study aims to identify the optimal sparse sensor layout required to accurately estimate the Center of Pressure (CoP) by analyzing the trade-off between sensor number, spatial placement, and reconstruction error. Plantar pressure data were collected from twelve healthy participants walking at a self-selected speed using 16-sensor connected insoles. A combinatorial algorithm evaluated all 216\u22121 possible sensor combinations to minimize the Root Mean Square Error (RMSE) in the antero-posterior, medio-lateral, and global Euclidean directions. Results reveal a non-linear convergence of accuracy that depends on the spatial axis. For longitudinal and global progression, a clear inflection point achieving sub-centimetric accuracy (RMSE &lt; 5 mm) is reached at seven sensors. In contrast, medio-lateral tracking shows its largest discrete error reduction at five sensors, followed by gradual improvements at higher densities. Anatomical frequency analysis highlights distinct spatial requirements: the posterior heel is consistently selected for medio-lateral accuracy, while the lateral arch and metatarsal regions are critical for longitudinal progression. These findings suggest that while a minimum of seven strategically placed sensors enables robust CoP tracking across all spatial axes, optimal hardware design should remain task-specific. This work provides a data-driven framework for the development of energy-efficient wearable gait monitoring systems.<\/jats:p>","DOI":"10.3390\/s26092723","type":"journal-article","created":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T11:33:37Z","timestamp":1777376017000},"page":"2723","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Optimizing Sensor Number and Placement for Accurate and Robust Center of Pressure Estimation on Instrumented Insoles"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-8929-7775","authenticated-orcid":false,"given":"Matthis","family":"Gautier","sequence":"first","affiliation":[{"name":"Centre de Nanosciences et de Nanotechnologies, Centre National de la Recherche Scientifique, Universit\u00e9 Paris-Saclay, 91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-3128-2306","authenticated-orcid":false,"given":"Fabien","family":"Parrain","sequence":"additional","affiliation":[{"name":"Centre de Nanosciences et de Nanotechnologies, Centre National de la Recherche Scientifique, Universit\u00e9 Paris-Saclay, 91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6121-7188","authenticated-orcid":false,"given":"Pierre-Yves","family":"Joubert","sequence":"additional","affiliation":[{"name":"Centre de Nanosciences et de Nanotechnologies, Centre National de la Recherche Scientifique, Universit\u00e9 Paris-Saclay, 91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,4,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/0966-6362(96)82849-9","article-title":"Human balance and posture control during standing and walking","volume":"3","author":"Winter","year":"1995","journal-title":"Gait Posture"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Gage, J.R. (1993). Gait Analysis in Cerebral Palsy, Mac Keith Press.","DOI":"10.1097\/00003086-199303000-00016"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s11517-008-0382-3","article-title":"Spatial synchronization of an insole pressure distribution system with a 3D motion analysis system for center of pressure measurements","volume":"47","author":"Fradet","year":"2009","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/S0966-6362(00)00071-0","article-title":"Comparison of an in-shoe pressure measurement device to a force plate: Concurrent validity of center of pressure measurements","volume":"12","author":"Chesnin","year":"2000","journal-title":"Gait Posture"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.foot.2012.07.001","article-title":"In-shoe center of pressure: Indirect force plate vs. direct insole measurement","volume":"22","author":"Debbi","year":"2012","journal-title":"Foot"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1080\/02640414.2016.1161205","article-title":"Validation of Moticon\u2019s OpenGo sensor insoles during gait, jumps, balance and cross-country skiing specific imitation movements","volume":"35","author":"Martiner","year":"2017","journal-title":"J. Sport. Sci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1109\/TITB.2007.899493","article-title":"Gait Analysis Using a Shoe-Integrated Wireless Sensor System","volume":"12","author":"Bamberg","year":"2008","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/1743-0003-9-21","article-title":"A review of wearable sensors and systems with application in rehabilitation","volume":"9","author":"Patel","year":"2012","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Camomilla, V., Bergamini, E., Fantozzi, S., and Vannozzi, G. (2018). Trends supporting the in-field use of wearable inertial sensors for sport performance evaluation: A systematic review. J. Sport Health Sci., 18.","DOI":"10.3390\/s18030873"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.robot.2014.09.032","article-title":"Review of assistive strategies in powered lower-limb orthoses and exoskeletons","volume":"64","author":"Yan","year":"2015","journal-title":"Robot. Auton. Syst."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Chou, L.W., Shen, J.H., Lin, H.T., Yang, Y.T., and Hu, W.P. (2021). A Study on the Influence of Number\/Distribution of Sensing Points of the Smart Insoles on the Center of Pressure Estimation for the Internet of Things Applications. Sustainability, 13.","DOI":"10.3390\/su13052934"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1186\/s12938-016-0237-3","article-title":"The configuration of plantar pressure sensing cells for wearable measurement of COP coordinates","volume":"15","author":"Wang","year":"2016","journal-title":"Biomed. Eng. Online"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Fuchs, P.X., Chen, W.H., and Shiang, T.Y. (2024). Center of Pressure Measurement Accuracy via Insoles with a Reduced Pressure Sensor Number during Gaits. Sensors, 24.","DOI":"10.3390\/s24154918"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2771","DOI":"10.1080\/14763141.2022.2057354","article-title":"Sensor number in simplified insole layouts and the validity of ground reaction forces during locomotion","volume":"23","author":"Fuchs","year":"2022","journal-title":"Sport. Biomech."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Hsu, W.C., Sugiarto, T., Chen, J.W., and Lin, Y.J. (2018). The design and application of simplified insole-based prototypes with plantar pressure measurement for fast screening of flat-foot. Sensors, 18.","DOI":"10.3390\/s18113617"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2597","DOI":"10.1016\/j.jbiomech.2008.05.007","article-title":"Estimating the complete ground reaction forces with pressure insoles in walking","volume":"41","author":"Fong","year":"2008","journal-title":"J. Biomech."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Abou Ghaida, H., Poffo, L., Le Page, R., and Goujon, J.M. (2023). Effect of Sensor Size, Number and Position under the Foot to Measure the Center of Pressure (CoP) Displacement and Total Center of Pressure (CoPT) Using an Anatomical Foot Model. Sensors, 23.","DOI":"10.3390\/s23104848"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"28077","DOI":"10.1109\/JSEN.2021.3125021","article-title":"Optimal Sensor Placement for Estimation of Center of Plantar Pressure Based on the Improved Genetic Algorithms","volume":"21","author":"Xian","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Lin, C.W., Ruan, S.J., Hsu, W.C., Tu, Y.W., and Han, S.L. (2020). Optimizing the Sensor Placement for Foot Plantar Center of Pressure without Prior Knowledge Using Deep Reinforcement Learning. Sensors, 20.","DOI":"10.3390\/s20195588"},{"key":"ref_20","unstructured":"Moticon (2023). OpenGo Sensor Insole Specification, Moticon. Version 03.03."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/9\/2723\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T12:00:18Z","timestamp":1777377618000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/9\/2723"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,28]]},"references-count":20,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,5]]}},"alternative-id":["s26092723"],"URL":"https:\/\/doi.org\/10.3390\/s26092723","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,28]]}}}