{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T12:14:06Z","timestamp":1785413646472,"version":"3.56.0"},"reference-count":24,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T00:00:00Z","timestamp":1777852800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100031938","name":"Canc\u00e9rop\u00f4le Lyon Auvergne-Rh\u00f4ne-Alpes","doi-asserted-by":"crossref","award":["CV-2021-024"],"award-info":[{"award-number":["CV-2021-024"]}],"id":[{"id":"10.13039\/100031938","id-type":"DOI","asserted-by":"crossref"}]},{"award":["CV-2021-024"],"award-info":[{"award-number":["CV-2021-024"]}],"id":[{"id":"https:\/\/ror.org\/02nhpf205","id-type":"ROR","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007380","name":"Fondation de l\u2019Avenir","doi-asserted-by":"publisher","award":["AP-RM-21-001"],"award-info":[{"award-number":["AP-RM-21-001"]}],"id":[{"id":"10.13039\/100007380","id-type":"DOI","asserted-by":"publisher"}]},{"award":["AP-RM-21-001"],"award-info":[{"award-number":["AP-RM-21-001"]}],"id":[{"id":"https:\/\/ror.org\/02dddmh90","id-type":"ROR","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>(1) Background: Breast cancer screening remains limited by mammography, particularly in younger women, in dense breast tissue, and in the detection of interval cancers. The PHI-BRA Smart Bra was developed as a wearable, non-invasive device combining thermography and bioimpedance for frequent breast monitoring. This first-in-human study aimed to assess the feasibility and in vivo diagnostic performance of the PHI-BRA system in discriminating between women with and without breast lesions. (2) Methods: A prospective feasibility study was conducted between March 2023 and February 2024. A calibration cohort (n = 15) was used to define the discrimination model, followed by an analysis cohort (n = 26; 13 with breast lesions and 13 without). Thermal and bioimpedance signals were acquired using the PHI-BRA device. Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis, with mammography as the reference standard. (3) Results: In the analysis cohort, the temperature-based model achieved an area under the ROC curve (AUC) of 80.8% (95% CI [63.2\u201398.3]). At the optimal threshold, sensitivity was 84.6% (95% CI [61.5\u2013100]) and specificity was 76.9% (95% CI [53.8\u2013100]). Exploratory bioimpedance analyses showed lower sensitivity but high specificity, mainly limited by sensor contact stability. No adverse events were reported. (4) Conclusions: This first-in-human study demonstrates an initial exploration of the feasibility and safety of a wearable thermography-based approach for breast lesion discrimination. The results support further clinical validation of a multimodal wearable system as a complementary tool to existing breast cancer screening strategies.<\/jats:p>","DOI":"10.3390\/s26092869","type":"journal-article","created":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T07:57:29Z","timestamp":1777967849000},"page":"2869","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Assessing the Diagnostic Performance of a Smart Bra Using Temperature and Bioimpedance for Breast Cancer Detection: A First-in-Human Study"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-7636-7345","authenticated-orcid":false,"given":"Anne-Sophie","family":"Belmont","sequence":"first","affiliation":[{"name":"Plateforme Transversale de Recherche Clinique de l\u2019Institut de Canc\u00e9rologie, Hospices Civils de Lyon, 69495 Pierre-B\u00e9nite, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0070-9856","authenticated-orcid":false,"given":"Marie-Val\u00e9rie","family":"Moreno","sequence":"additional","affiliation":[{"name":"Research and Development Center, RunSys, 162 Lot le Verger, 69380 Chasselay, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eloise","family":"Aubret","sequence":"additional","affiliation":[{"name":"Plateforme Transversale de Recherche Clinique de l\u2019Institut de Canc\u00e9rologie, Hospices Civils de Lyon, 69495 Pierre-B\u00e9nite, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justine","family":"Dubreuil","sequence":"additional","affiliation":[{"name":"Plateforme Transversale de Recherche Clinique de l\u2019Institut de Canc\u00e9rologie, Hospices Civils de Lyon, 69495 Pierre-B\u00e9nite, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-5508-6650","authenticated-orcid":false,"given":"Nathalie","family":"Piazon","sequence":"additional","affiliation":[{"name":"Service de Gyn\u00e9cologie, H\u00f4pital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julien","family":"Berthiller","sequence":"additional","affiliation":[{"name":"P\u00f4le de Sant\u00e9 Public, Hospices Civils de Lyon, 69 003 Lyon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2205-9655","authenticated-orcid":false,"given":"Maxime","family":"Bonjour","sequence":"additional","affiliation":[{"name":"P\u00f4le de Sant\u00e9 Public, Hospices Civils de Lyon, 69 003 Lyon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5143-0666","authenticated-orcid":false,"given":"Emmanuelle","family":"Dantony","sequence":"additional","affiliation":[{"name":"P\u00f4le de Sant\u00e9 Public, Hospices Civils de Lyon, 69 003 Lyon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Audrey","family":"Haquin","sequence":"additional","affiliation":[{"name":"Service d\u2019Imageries M\u00e9dicales, H\u00f4pital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6770-7340","authenticated-orcid":false,"given":"Marion","family":"Cortet","sequence":"additional","affiliation":[{"name":"Service de Gyn\u00e9cologie, H\u00f4pital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,5,4]]},"reference":[{"key":"ref_1","first-page":"229","article-title":"Global cancer statistics 2022: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries","volume":"74","author":"Bray","year":"2024","journal-title":"CA Cancer J. Clin."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Moreno, M.-V., and Herrera, E. (2019). Evaluation on Phantoms of the Feasibility of a Smart Bra to Detect Breast Cancer in Young Adults. Sensors, 19.","DOI":"10.3390\/s19245491"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"109219","DOI":"10.1016\/j.compbiomed.2024.109219","article-title":"Portable noninvasive technologies for early breast cancer detection: A systematic review","volume":"182","author":"Aboagye","year":"2024","journal-title":"Comput. Biol. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1186\/s13643-024-02708-9","article-title":"Breast thermography: A systematic review and meta-analysis","volume":"13","year":"2024","journal-title":"Syst. Rev."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1080\/03091902.2019.1664672","article-title":"A survey of breast cancer screening techniques: Thermography and electrical impedance tomography","volume":"43","author":"Zerhouni","year":"2019","journal-title":"J. Med. Eng. Technol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1159\/000448347","article-title":"Comparison of the Accuracy of Thermography and Mammography in the Detection of Breast Cancer","volume":"11","author":"Omranipour","year":"2016","journal-title":"Breast Care"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"e713","DOI":"10.1016\/S1470-2045(17)30833-1","article-title":"Breast thermography alone no substitute for mammography","volume":"18","author":"Gourd","year":"2017","journal-title":"Lancet Oncol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e5970","DOI":"10.1097\/MD.0000000000005970","article-title":"Bioimpedance spectroscopy can precisely discriminate human breast carcinoma from benign tumors","volume":"96","author":"Du","year":"2017","journal-title":"Medicine"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Gupta, D., Lammersfeld, C.A., Vashi, P.G., King, J., Dahlk, S.L., Grutsch, J.F., and Lis, C.G. (2008). Bioelectrical impedance phase angle as a prognostic indicator in breast cancer. BMC Cancer, 8.","DOI":"10.1186\/1471-2407-8-249"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2703","DOI":"10.1200\/JCO.2005.06.155","article-title":"Electrical Impedance Scanning for the Early Detection of Breast Cancer in Young Women: Preliminary Results of a Multicenter Prospective Clinical Trial","volume":"23","author":"Stojadinovic","year":"2005","journal-title":"J. Clin. Oncol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1111\/j.1749-6632.1999.tb09446.x","article-title":"A Review of Parameters for the Bioelectrical Characterization of Breast Tissue","volume":"873","author":"Jossinet","year":"1999","journal-title":"Ann. N. Y. Acad. Sci."},{"key":"ref_12","unstructured":"(2009). Biological Evaluation of Medical Devices\u2014Part 5: Tests for In Vitro Cytotoxicity (Standard No. ISO 10993-5:2009)."},{"key":"ref_13","unstructured":"Moreno, M.V. (2020). Medical Device for Detecting a Mammary Tumor. (WO2020201546A1), World Intellectual Property Organization (WIPO)."},{"key":"ref_14","unstructured":"R Core Team (2022). R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"105074","DOI":"10.1016\/j.cmpb.2019.105074","article-title":"Role of image thermography in early breast cancer detection\u2014Past, present and future","volume":"183","author":"Singh","year":"2020","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Ryan, L., and Agaian, S. (2025). Breast Cancer Detection Using Infrared Thermography: A Survey of Texture Analysis and Machine Learning Approaches. Bioengineering, 12.","DOI":"10.3390\/bioengineering12060639"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"506","DOI":"10.5603\/GP.a2022.0014","article-title":"Contact thermography\u2014A modern method and its role in breast cancer prevention","volume":"93","author":"Zborowska","year":"2022","journal-title":"Ginekol. Pol."},{"key":"ref_18","first-page":"8565490","article-title":"The Accuracy of Electrical Impedance Tomography for Breast Cancer Detection: A Systematic Review and Meta-Analysis","volume":"2022","author":"Mirhoseini","year":"2022","journal-title":"Breast J."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.1007\/s003300000553","article-title":"Electrical impedance scanning for classifying suspicious breast lesions: First results","volume":"10","author":"Malich","year":"2000","journal-title":"Eur. Radiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2522","DOI":"10.1002\/mp.13474","article-title":"Technical Note: A new method to rapidly identify benign and malignant breast lumps through bioelectrical impedance spectroscopy","volume":"46","author":"Wu","year":"2019","journal-title":"Med. Phys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"505","DOI":"10.4149\/BLL_2016_098","article-title":"Effectiveness of breast electrical impedance imaging for clinically suspicious breast lesions","volume":"117","author":"Daglar","year":"2016","journal-title":"Bratisl. Med. J."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1684\/bdc.2012.1595","article-title":"Canaux cationiques TRP dans le cancer du sein: Expression, r\u00f4le et corr\u00e9lation avec des param\u00e8tres cliniques","volume":"99","author":"Gautier","year":"2012","journal-title":"Bull. Cancer"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1136\/gutjnl-2021-326610","article-title":"SK2 channels set a signalling hub bolstering CAF-triggered tumourigenic processes in pancreatic cancer","volume":"72","author":"Nigri","year":"2023","journal-title":"Gut"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"3287","DOI":"10.31557\/APJCP.2022.23.10.3287","article-title":"Comparison of Classification Success Rates of Different Machine Learning Algorithms in the Diagnosis of Breast Cancer","volume":"23","author":"Ozcan","year":"2022","journal-title":"Asian Pac. J. Cancer Prev."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/9\/2869\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T04:17:58Z","timestamp":1778041078000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/9\/2869"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,4]]},"references-count":24,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,5]]}},"alternative-id":["s26092869"],"URL":"https:\/\/doi.org\/10.3390\/s26092869","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,4]]}}}