{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T00:12:57Z","timestamp":1788826377146,"version":"build-2803163510"},"reference-count":44,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This study validates a clinically accessible approach for quantifying the Upper Extremity Reachable Workspace (UERW) using monocular AI-driven Markerless Motion Capture (MMC). Objective validation of such techniques for clinically oriented tasks is essential to support their adoption in clinical motion analysis. Nine adults without impairments performed the standardized UERW task, reaching targets distributed across a virtual sphere centered on the torso and displayed via VR headset. Movements were simultaneously captured with a marker-based system and eight FLIR cameras; monocular analysis was applied to two videos representing frontal and offset camera configurations. Agreement was assessed by comparing the percentage workspacereached across six of eight workspace octants between the systems. The frontal camera demonstrated strong agreement with the marker-based reference (mean bias: 0.61\u00b10.12% reachspace per octant), whereas the offset view underestimated workspace reached \u22125.66\u00b10.45%. Depth-related errors in the frontal configuration were confined to posterior octants, whereas the offset view introduced inaccuracies in both contralateral and posterior octants. These findings support the feasibility of a frontal monocular camera for UERW assessment, particularly for anterior workspace evaluation. While posterior accuracy remains limited by depth estimation and anatomical occlusion errors, the overall results demonstrate clinical potential for practical, monocular-camera assessments.<\/jats:p>","DOI":"10.3390\/s26113421","type":"journal-article","created":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T12:09:07Z","timestamp":1779970147000},"page":"3421","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Monocular Markerless Motion Capture Enables Quantitative Assessment of Upper Extremity Reachable Workspace"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8387-9887","authenticated-orcid":false,"given":"Seth","family":"Donahue","sequence":"first","affiliation":[{"name":"Shriners Children\u2019s Lexington, Lexington, KY 40508, USA"},{"name":"Department of Physical Therapy, University of Kentucky, Lexington, KY 40536, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2382-8065","authenticated-orcid":false,"given":"J.D.","family":"Peiffer","sequence":"additional","affiliation":[{"name":"Shirley Ryan AbilityLab, Center for Bionic Medicine, Chicago, IL 60611, USA"},{"name":"Department of Physical Medicine and Rehabilitation, Northwestern University, Evanston, IL 60208, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6449-6613","authenticated-orcid":false,"given":"R. Tyler","family":"Richardson","sequence":"additional","affiliation":[{"name":"Department of Kinesiology, School of Behavioral Sciences and Education, Pennsylvania State University at Harrisburg, Middletown, PA 17057, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yishan","family":"Zhong","sequence":"additional","affiliation":[{"name":"School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shaun Q. Y.","family":"Tan","sequence":"additional","affiliation":[{"name":"School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benoit L.","family":"Marteau","sequence":"additional","affiliation":[{"name":"School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephanie A.","family":"Russo","sequence":"additional","affiliation":[{"name":"Nationwide Children\u2019s Hospital, Columbus, OH 43205, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3961-3608","authenticated-orcid":false,"given":"May D.","family":"Wang","sequence":"additional","affiliation":[{"name":"Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30322, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5714-1400","authenticated-orcid":false,"given":"R. James","family":"Cotton","sequence":"additional","affiliation":[{"name":"Shirley Ryan AbilityLab, Center for Bionic Medicine, Chicago, IL 60611, USA"},{"name":"Department of Physical Medicine and Rehabilitation, Northwestern University, Evanston, IL 60208, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ross","family":"Chafetz","sequence":"additional","affiliation":[{"name":"Shriners Hospitals for Children, Philadelphia, PA 19140, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,5,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"106501","DOI":"10.1016\/j.clinbiomech.2025.106501","article-title":"Automated identification of clinically meaningful biomechanical phenotypes in cerebral palsy through multicenter gait data","volume":"125","author":"Graf","year":"2025","journal-title":"Clin. Biomech."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.jhsa.2023.11.013","article-title":"Evaluation of Upper Extremity Reachable Workspace in Children With Brachial Plexus Birth Injury","volume":"49","author":"Richardson","year":"2024","journal-title":"J. Hand Surg."},{"key":"ref_3","first-page":"1","article-title":"Validity, Reliability, and Sensitivity of a 3D Vision Sensor-Based Upper Extremity Reachable Workspace Evaluation in Neuromuscular Diseases","volume":"5","author":"Han","year":"2013","journal-title":"PLoS Curr."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"430","DOI":"10.3928\/01477447-20100429-25","article-title":"Current concepts: Neonatal brachial plexus palsy","volume":"33","author":"Abzug","year":"2010","journal-title":"Orthopedics"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1111\/j.1469-8749.2008.03098.x","article-title":"Quantification of upper extremity function and range of motion in children with cerebral palsy","volume":"50","author":"Koman","year":"2008","journal-title":"Dev. Med. Child Neurol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1007\/s11999-013-3324-9","article-title":"Assessing shoulder motion in children: Age limitations to mallet and ABC loops","volume":"472","author":"Pearl","year":"2014","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_7","first-page":"128","article-title":"Evaluating the acromion marker cluster as a method for measuring scapular orientation in children with brachial plexus birth palsy","volume":"30","author":"Nicholson","year":"2014","journal-title":"J. Appl. Biomech."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.jse.2013.06.023","article-title":"Scapulothoracic and glenohumeral contributions to motion in children with brachial plexus birth palsy","volume":"23","author":"Russo","year":"2014","journal-title":"J. Shoulder Elb. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Han, J.J., Hayward, L.J., Adams, C., and Perez-Ibarra, J. (2025). Reachable Workspace as a Clinical Outcome for Upper Extremity Function: A Narrative Review. Muscle Nerve.","DOI":"10.1002\/mus.70190"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1002\/mus.24287","article-title":"Reachable workspace in facioscapulohumeral muscular dystrophy (FSHD) by Kinect","volume":"51","author":"Han","year":"2015","journal-title":"Muscle Nerve"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1002\/mus.24567","article-title":"Upper extremity 3-dimensional reachable workspace analysis in dystrophinopathy using Kinect","volume":"52","author":"Han","year":"2015","journal-title":"Muscle Nerve"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1080\/21678421.2016.1241278","article-title":"Longitudinal Evaluation of Upper Extremity Reachable Workspace in ALS by Kinect Sensor","volume":"18","author":"Oskarsson","year":"2017","journal-title":"Amyotroph. Lateral Scler. Front. Degener."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1097\/BPO.0000000000002926","article-title":"Vertical video-based gait analysis for assessment of transverse plane motion: Reliability and validity in a neuromuscular population","volume":"45","author":"Olleac","year":"2025","journal-title":"J. Pediatr. Orthop."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"326","DOI":"10.2106\/00004623-200602000-00011","article-title":"Validation of the Shriners Hospital for Children Upper Extremity Evaluation (SHUEE) for Children with Hemiplegic Cerebral Palsy","volume":"88","author":"Davids","year":"2006","journal-title":"J. Bone Jt. Surg."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"94","DOI":"10.55275\/JPOSNA-2020-94","article-title":"Gait analysis at your fingertips: Accuracy and reliability of mobile app enhanced observational gait analysis in children with cerebral palsy","volume":"2","author":"Kephart","year":"2020","journal-title":"J. Pediatr. Orthop. Soc. N. Am."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.gaitpost.2023.05.029","article-title":"Comparison of kinematics between Theia markerless and conventional marker-based gait analysis in clinical patients","volume":"104","author":"Wren","year":"2023","journal-title":"Gait Posture"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"100128","DOI":"10.1016\/j.bea.2024.100128","article-title":"Validation of upper extremity kinematics using Markerless motion capture","volume":"7","author":"Hansen","year":"2024","journal-title":"Biomed. Eng. Adv."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"110422","DOI":"10.1016\/j.jbiomech.2021.110422","article-title":"Inter-Session Repeatability of Markerless Motion Capture Gait Kinematics","volume":"121","author":"Kanko","year":"2021","journal-title":"J. Biomech."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Uhlrich, S.D., Falisse, A., Kidzi\u0144ski, \u0141., Muccini, J., Ko, M., Chaudhari, A.S., Hicks, J.L., and Delp, S.L. (2023). OpenCap: Human Movement Dynamics from Smartphone Videos. PLoS Comput. Biol., 19.","DOI":"10.1371\/journal.pcbi.1011462"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Cotton, R.J. (2024). Differentiable Biomechanics Unlocks Opportunities for Markerless Motion Capture. arXiv.","DOI":"10.1109\/ICORR66766.2025.11063174"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Farrens, A., Chan, V., Garcia-Fernandez, L., Zhu, Z.J., Kim, J.M., Farrens, M.K., and King, S.T. (2025, January 12\u201316). Markerless Motion Capture Enhances Clinical Assessments: Preliminary Validation with the Box and Blocks Test. Proceedings of the IEEE International Conference on Rehabilitation Robotics (ICORR), Chicago, IL, USA.","DOI":"10.1109\/ICORR66766.2025.11063098"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1109\/TMRB.2025.3605962","article-title":"Differentiable Biomechanics for Markerless Motion Capture in Upper Limb Stroke Rehabilitation: A Comparison With Optical Motion Capture","volume":"8","author":"Unger","year":"2025","journal-title":"IEEE Trans. Med. Robot. Bionics"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"e12995","DOI":"10.7717\/peerj.12995","article-title":"Applications and limitations of current markerless motion capture methods for clinical gait biomechanics","volume":"10","author":"Wade","year":"2022","journal-title":"PeerJ"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"112738","DOI":"10.1016\/j.jbiomech.2025.112738","article-title":"Artificial intelligence-enhanced 3D gait analysis with a single consumer-grade camera","volume":"187","author":"Guo","year":"2025","journal-title":"J. Biomech."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"112233","DOI":"10.1016\/j.jbiomech.2024.112233","article-title":"Markerless motion analysis to assess reaching-sideways in individuals with dyskinetic cerebral palsy: A validity study","volume":"173","author":"Vanmechelen","year":"2024","journal-title":"J. Biomech."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1186\/s12984-023-01186-9","article-title":"A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation","volume":"20","author":"Lam","year":"2023","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_27","unstructured":"Peiffer, J.D., Shah, K., Djuraskovic, I., Anarwala, S., Abdou, K., Patel, R., Jayabalan, P., Pennicooke, B., and Cotton, R.J. (2025). Portable Biomechanics Laboratory: Clinically Accessible Movement Analysis from a Handheld Smartphone. arXiv."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Koleini, F., Saleem, M.U., Wang, P., Xue, H., Helmy, A., and Fenwick, A. (2025). BioPose: Biomechanically Accurate 3D Pose Estimation from Monocular Videos. arXiv.","DOI":"10.1109\/WACV61041.2025.00617"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1080\/23335432.2025.2556187","article-title":"Assessing single camera markerless motion capture with OpenSim inverse kinematics during upper limb activities of daily living","volume":"12","author":"Scott","year":"2025","journal-title":"Int. Biomech."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"110908","DOI":"10.1016\/j.compbiomed.2025.110908","article-title":"Video-based markerless assessment of bilateral upper limb motor activity following cervical spinal cord injury","volume":"196","author":"Lagomarsino","year":"2025","journal-title":"Comput. Biol. Med."},{"key":"ref_31","first-page":"106603","article-title":"Hand tracking for clinical applications: Validation of the Google MediaPipe framework for finger tapping assessment","volume":"96","author":"Panattoni","year":"2024","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1186\/s12984-025-01808-4","article-title":"Using MediaPipe to track upper-limb reaching movements after stroke: A proof-of-principle study","volume":"22","author":"Wagh","year":"2025","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1080\/17453674.2018.1525195","article-title":"Knee joint sagittal plane movement in cerebral palsy: A comparative study of 2-dimensional markerless video and 3-dimensional gait analysis","volume":"89","author":"Cereatti","year":"2018","journal-title":"Acta Orthop."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"e13517","DOI":"10.7717\/peerj.13517","article-title":"Healthcare applications of single camera markerless motion capture: A scoping review","volume":"10","author":"Scott","year":"2022","journal-title":"PeerJ"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Tan, S.Q.Y., Zhong, Y., Marteau, B., Hornback, A., Shi, W., Warshauer, S., Courter, R., Donahue, S., Lottiers, L., and Russo, S. (2024, January 5\u20136). VR-RAISE: Virtual Reality for Reachability Assessment Using an Interactive System Environment. Proceedings of the 2024 IEEE 3rd International Conference on Intelligent Reality (ICIR), Coimbra, Portugal.","DOI":"10.1109\/ICIR64558.2024.10976979"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1109\/TBIOM.2020.3037257","article-title":"MeTRAbs: Metric-Scale Truncation-Robust Heatmaps for Absolute 3D Human Pose Estimation","volume":"3","author":"Linder","year":"2021","journal-title":"IEEE Trans. Biom. Behav. Identity Sci."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Ghorbani, S., Mahdaviani, K., Thaler, A., Kording, K., Cook, D.J., Blohm, G., and Troje, N.F. (2021). MoVi: A Large Multi-Purpose Human Motion and Video Dataset. PLoS ONE, 16.","DOI":"10.1371\/journal.pone.0253157"},{"key":"ref_38","unstructured":"Chen, K., Wang, J., Pang, J., Cao, Y., Xiong, Y., Li, X., Sun, S., Feng, W., Liu, Z., and Xu, J. (2019). MMDetection: Open MMLab Detection Toolbox and Benchmark. arXiv."},{"key":"ref_39","unstructured":"Guyon, I., Luxburg, U.V., Bengio, S., Wallach, H., Fergus, R., Vishwanathan, S., and Garnett, R. (2017). Attention is All you Need. Proceedings of the Advances in Neural Information Processing Systems, Curran Associates, Inc."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Werling, K., Raitor, M., Stingel, J., Hicks, J.L., Collins, S., Delp, S.L., and Liu, C.K. (2022). Rapid Bilevel Optimization to Concurrently Solve Musculoskeletal Scaling, Marker Registration, and Inverse Kinematic Problems for Human Motion Reconstruction. bioRxiv.","DOI":"10.1101\/2022.08.22.504896"},{"key":"ref_41","unstructured":"Kidger, P., and Garcia, C. (2021). Equinox: Neural networks in JAX via callable PyTrees and filtered transformations. arXiv."},{"key":"ref_42","unstructured":"DeepMind (2025, May 05). The DeepMind JAX Ecosystem. Available online: https:\/\/github.com\/google-deepmind."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.otsr.2009.04.012","article-title":"Upper extremity kinematics analysis in obstetrical brachial plexus palsy","volume":"95","author":"Fitoussi","year":"2009","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"112","DOI":"10.2106\/JBJS.N.00203","article-title":"Glenohumeral abduction contracture in children with unresolved neonatal brachial plexus palsy","volume":"97","author":"Eismann","year":"2015","journal-title":"J. Bone Jt. Surg. Am."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/11\/3421\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T17:36:50Z","timestamp":1780076210000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/11\/3421"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,28]]},"references-count":44,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["s26113421"],"URL":"https:\/\/doi.org\/10.3390\/s26113421","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,28]]}}}