{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T18:19:34Z","timestamp":1785435574627,"version":"3.56.0"},"reference-count":44,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Australian government research training program scholarship"},{"id":[{"id":"https:\/\/ror.org\/0314h5y94","id-type":"ROR","asserted-by":"publisher"}]},{"name":"Balance Mat Pty. Ltd."},{"DOI":"10.13039\/501100001802","name":"University of Canberra","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001802","id-type":"DOI","asserted-by":"crossref"}]},{"id":[{"id":"https:\/\/ror.org\/04s1nv328","id-type":"ROR","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Background: Early identification of balance impairments is critical for detecting the fall risk in older adults. Force plates are the standard for measuring postural sway, but are restricted in practice because they are cumbersome and expensive. The Balance Mat is a portable device that requires comprehensive validation against force plates and clinical benchmarks in older adult populations. Objective: The objective of this study was to evaluate the technical validity and clinical discriminative ability of the Balance Mat against a laboratory-grade force plate, clinical tests, and the fall history in an older adult cohort. Methods: Fifty-six community-dwelling older adults performed static balance assessments across six stance conditions. Postural sway data were recorded simultaneously using the Balance Mat and a force plate. The technical validity was assessed using Spearman\u2019s rank correlation and intraclass correlation coefficients. Linear regression models were applied to calibrate the Balance Mat outputs against the force plate. The diagnostic accuracy for classifying the fall risk against the timed up and go test, the Falls Efficacy Scale-International, and the retrospective fall history was evaluated using an area-under-the-curve analysis. Results: The Balance Mat demonstrated strong associations with force plate measurements, particularly for the sway path\/velocity, variance and Area95 (r&gt;0.80). Following calibration, the absolute agreement for the sway path\/velocity reached excellent levels (ICC=0.93) and good levels for Area95 and RMS (ICC&gt;0.75), whereas the mean sway demonstrated a poor agreement and was excluded. For fall-risk classification, the calibrated Balance Mat achieved a fair accuracy for the retrospective fall history and a high Falls Efficacy Scale-International concern (area under the curve, 0.76\u20130.78), and a fair accuracy for the timed up and go thresholds (area under the curve, 0.70). Conclusions: The calibrated Balance Mat provided valid measurements of postural sway that aligned with the force plate parameters, particularly for the sway path\/velocity and Area95. The within-stance agreement for the sway path\/velocity ranged from ICC = 0.44 to 0.88, and the pooled value should not be interpreted as the uniform performance across all stance conditions. Given its fair diagnostic accuracy, the device is best utilised as a portable screening tool in combination with standard clinical assessments and the fall history rather than as a standalone diagnostic test.<\/jats:p>","DOI":"10.3390\/s26134021","type":"journal-article","created":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T03:20:21Z","timestamp":1782357621000},"page":"4021","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Technical and Clinical Validation of a Portable Optical Fibre Balance Mat for Quantifying Postural Sway in Older Adults"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-6923-4613","authenticated-orcid":false,"given":"Abishek","family":"Shrestha","sequence":"first","affiliation":[{"name":"Faculty of Science and Technology, University of Canberra (UC), Bruce, ACT 2617, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7509-5265","authenticated-orcid":false,"given":"Damith","family":"Herath","sequence":"additional","affiliation":[{"name":"Faculty of Science and Technology, University of Canberra (UC), Bruce, ACT 2617, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angie","family":"Fearon","sequence":"additional","affiliation":[{"name":"Faculty of Health, University of Canberra, Bruce, ACT 2617, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8324-3870","authenticated-orcid":false,"given":"Maryam","family":"Ghahramani","sequence":"additional","affiliation":[{"name":"Faculty of Science and Technology, University of Canberra (UC), Bruce, ACT 2617, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,6,24]]},"reference":[{"key":"ref_1","unstructured":"AIHW (2026, April 20). Falls, 2023, Available online: https:\/\/www.aihw.gov.au\/reports\/injury\/falls."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jcgg.2013.05.002","article-title":"Relevance of balance measurement tools and balance training for fall prevention in older adults","volume":"5","author":"Noohu","year":"2014","journal-title":"J. Clin. Gerontol. Geriatr."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1519\/JPT.0000000000000111","article-title":"Validity and reliability of a portable balance tracking system, BTrackS, in older adults","volume":"41","author":"Levy","year":"2018","journal-title":"J. Geriatr. Phys. Ther."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2049","DOI":"10.1088\/0967-3334\/33\/12\/2049","article-title":"Quantitative falls risk estimation through multi-sensor assessment of standing balance","volume":"33","author":"Greene","year":"2012","journal-title":"Physiol. Meas."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2324","DOI":"10.1109\/TBME.2022.3142617","article-title":"Development of Data-Driven Metrics for Balance Impairment and Fall Risk Assessment in Older Adults","volume":"69","author":"McManus","year":"2022","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_6","first-page":"45","article-title":"Research and Clinical Applications of Assessing Balance","volume":"5","author":"Guskiewicz","year":"1996","journal-title":"Balance"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"304","DOI":"10.3138\/ptc.41.6.304","article-title":"Measuring balance in the elderly: Preliminary development of an instrument","volume":"41","author":"Berg","year":"1989","journal-title":"Physiother. Can."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/j.1532-5415.1991.tb01616.x","article-title":"The timed \u201cUp & Go\u201d: A test of basic functional mobility for frail elderly persons","volume":"39","author":"Podsiadlo","year":"1991","journal-title":"J. Am. Geriatr. Soc."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1111\/j.1532-5415.1986.tb05480.x","article-title":"Performance-oriented assessment of mobility problems in elderly patients","volume":"34","author":"Tinetti","year":"1986","journal-title":"J. Am. Geriatr. Soc."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1093\/ptj\/76.6.576","article-title":"Use of the Berg Balance Test to Predict Falls in Elderly Persons","volume":"76","author":"Thorbahn","year":"1996","journal-title":"Phys. Ther."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Chen, B., Liu, P., Xiao, F., Liu, Z., and Wang, Y. (2021). Review of the Upright Balance Assessment Based on the Force Plate. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph18052696"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.jbiomech.2018.05.008","article-title":"Leveling the playing field: Evaluation of a portable instrument for quantifying balance performance","volume":"75","author":"Richmond","year":"2018","journal-title":"J. Biomech."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Kelly, D., Esquivel, K.M., Gillespie, J., Condell, J., Davies, R., Karim, S., Nevala, E., Alam\u00e4ki, A., Jalovaara, J., and Barton, J. (2021). Feasibility of sensor technology for balance assessment in home rehabilitation settings. Sensors, 21.","DOI":"10.3390\/s21134438"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Ghahramani, M., Hosseini, I., and Herath, D. (2022). Performance analysis of a postural balance assessment mat prototype using inertial sensor. Proceedings of the 2022 IEEE Sensors, IEEE.","DOI":"10.1109\/SENSORS52175.2022.9967035"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Shrestha, A., Herath, D., Fearon, A., and Ghahramani, M. (2025). Assessing the Reliability and Validity of a Balance Mat for Measuring Postural Stability: A Combined Robot-Human Approach. Proceedings of the 2025 IEEE Medical Measurements & Applications (MeMeA), IEEE.","DOI":"10.1109\/MeMeA65319.2025.11067995"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1186\/1743-0003-9-59","article-title":"ISway: A sensitive, valid and reliable measure of postural control","volume":"9","author":"Mancini","year":"2012","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.gaitpost.2009.11.012","article-title":"Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance","volume":"31","author":"Clark","year":"2010","journal-title":"Gait Posture"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.ish.2025.04.003","article-title":"Evaluating the test-retest reliability and comparability of postural sway measures from the Balance Mat and a force plate","volume":"1","author":"Raj","year":"2025","journal-title":"Intell. Sport. Health"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1093\/ageing\/afi196","article-title":"Development and initial validation of the Falls Efficacy Scale-International (FES-I)","volume":"34","author":"Yardley","year":"2005","journal-title":"Age Ageing"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1007\/s12603-011-0062-0","article-title":"Timed Up and Go test and risk of falls in older adults: A systematic review","volume":"15","author":"Beauchet","year":"2011","journal-title":"J. Nutr. Health Aging"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1093\/ageing\/32.3.315","article-title":"Identifying a cut-off point for normal mobility: A comparison of the timed \u2018up and go\u2019 test in community-dwelling and institutionalised elderly women","volume":"32","author":"Bischoff","year":"2003","journal-title":"Age Ageing"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1093\/ageing\/afp225","article-title":"The falls efficacy scale international (FES-I). A comprehensive longitudinal validation study","volume":"39","author":"Delbaere","year":"2010","journal-title":"Age Ageing"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1109\/10.532130","article-title":"Measures of postural steadiness: Differences between healthy young and elderly adults","volume":"43","author":"Prieto","year":"1996","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"891390","DOI":"10.1155\/2015\/891390","article-title":"Techniques and methods for testing the postural function in healthy and pathological subjects","volume":"2015","author":"Paillard","year":"2015","journal-title":"BioMed Res. Int."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1080\/02703181.2018.1556231","article-title":"Concurrent validity of postural sway measures in older adults with cognitive impairment","volume":"36","author":"McGough","year":"2018","journal-title":"Phys. Occup. Ther. Geriatr."},{"key":"ref_26","unstructured":"Evans, J.D. (1996). Straightforward Statistics for the Behavioral Sciences, Thomson Brooks\/Cole Publishing Co."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1111\/j.1651-2227.2006.00180.x","article-title":"Understanding diagnostic tests 1: Sensitivity, specificity and predictive values","volume":"96","author":"Akobeng","year":"2007","journal-title":"Acta Paediatr."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"195","DOI":"10.4103\/tjem.tjem_182_23","article-title":"Receiver operating characteristic curve analysis in diagnostic accuracy studies: A guide to interpreting the area under the curve value","volume":"23","author":"Aksel","year":"2023","journal-title":"Turk. J. Emerg. Med."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.gaitpost.2003.11.006","article-title":"The assessment of body sway and the choice of the stability parameter(s)","volume":"21","author":"Raymakers","year":"2005","journal-title":"Gait Posture"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Sturnieks, D.L., Arnold, R., and Lord, S.R. (2011). Validity and reliability of the Swaymeter device for measuring postural sway. BMC Geriatr., 11.","DOI":"10.1186\/1471-2318-11-63"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"18244","DOI":"10.3390\/s141018244","article-title":"Validating and calibrating the Nintendo Wii balance board to derive reliable center of pressure measures","volume":"14","author":"Leach","year":"2014","journal-title":"Sensors"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"e045431","DOI":"10.1136\/bmjopen-2020-045431","article-title":"Practical and validated tool to assess falls risk in the primary care setting: A systematic review","volume":"11","author":"Meekes","year":"2021","journal-title":"BMJ Open"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Barry, E., Galvin, R., Keogh, C., Horgan, F., and Fahey, T. (2014). Is the Timed Up and Go test a useful predictor of risk of falls in community dwelling older adults: A systematic review and meta-analysis. BMC Geriatr., 14.","DOI":"10.1186\/1471-2318-14-14"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1519\/JPT.0000000000000099","article-title":"Determining risk of falls in community dwelling older adults: A systematic review and meta-analysis using posttest probability","volume":"40","author":"Lusardi","year":"2017","journal-title":"J. Geriatr. Phys. Ther."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1097\/EDE.0b013e3181e89905","article-title":"Risk factors for falls in community-dwelling older people: A systematic review and meta-analysis","volume":"21","author":"Deandrea","year":"2010","journal-title":"Epidemiology"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Li, Y., Hou, L., Zhao, H., Xie, R., Yi, Y., and Ding, X. (2023). Risk factors for falls among community-dwelling older adults: A systematic review and meta-analysis. Front. Med., 9.","DOI":"10.3389\/fmed.2022.1019094"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Howcroft, J., Lemaire, E.D., Kofman, J., and McIlroy, W.E. (2017). Elderly fall risk prediction using static posturography. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0172398"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1007\/s11517-018-1901-5","article-title":"Body postural sway analysis in older people with different fall histories","volume":"57","author":"Ghahramani","year":"2019","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"112259","DOI":"10.1016\/j.exger.2023.112259","article-title":"A prospective cohort study on the association between new falls and balancing ability among older adults over 80 years who are independent","volume":"180","author":"Zhou","year":"2023","journal-title":"Exp. Gerontol."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Kozinc, \u017d., L\u00f6fler, S., Hofer, C., Carraro, U., and \u0160arabon, N. (2020). Diagnostic balance tests for assessing risk of falls and distinguishing older adult fallers and non-fallers: A systematic review with meta-analysis. Diagnostics, 10.","DOI":"10.3390\/diagnostics10090667"},{"key":"ref_42","first-page":"228","article-title":"Development of a protocol for improving the clinical utility of posturography as a fall-risk screening tool","volume":"66","author":"Berme","year":"2011","journal-title":"J. Gerontol. Ser. A Biomed. Sci. Med. Sci."},{"key":"ref_43","first-page":"239","article-title":"The relevance of clinical balance assessment tools to differentiate balance deficits","volume":"46","author":"Mancini","year":"2010","journal-title":"Eur. J. Phys. Rehabil. Med."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.gaitpost.2020.12.019","article-title":"Age-associated increase in postural variability relate to greater low-frequency center of pressure oscillations","volume":"85","author":"Delmas","year":"2021","journal-title":"Gait Posture"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/13\/4021\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T04:58:21Z","timestamp":1783486701000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/13\/4021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,24]]},"references-count":44,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["s26134021"],"URL":"https:\/\/doi.org\/10.3390\/s26134021","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,24]]}}}