{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T13:35:02Z","timestamp":1785418502649,"version":"3.56.0"},"reference-count":71,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T00:00:00Z","timestamp":1784246400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002457","name":"Chosun University","doi-asserted-by":"publisher","award":["CHOSUN UNIVERSITY-2026"],"award-info":[{"award-number":["CHOSUN UNIVERSITY-2026"]}],"id":[{"id":"10.13039\/501100002457","id-type":"DOI","asserted-by":"publisher"}]},{"award":["CHOSUN UNIVERSITY-2026"],"award-info":[{"award-number":["CHOSUN UNIVERSITY-2026"]}],"id":[{"id":"https:\/\/ror.org\/01zt9a375","id-type":"ROR","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Red blood cell (RBC) aggregation and viscosity-related flow resistance are important hemorheological parameters for assessing blood flow abnormalities, but their simultaneous measurement often requires multiple pumps or intermittent flow stoppage. In this study, we propose a single syringe pump microfluidic sensing method for simultaneous evaluation of RBC aggregation and transient flow response under continuous pulsatile blood delivery. The device consists of a single inlet, a main straight channel, a bifurcated test channel, and a big outlet. An optimized pulsatile-flow profile was applied by periodically switching the flow rate between high flow rate (Qh = 6 mL\/h for 2 min) and low flow rate (Ql = 1 mL\/h for 4 min), and the transient velocity response was analyzed to extract the time constant (\u03bb1) as a viscosity-related indicator. After optimization, the selected flow profile provides stable and reproducible measurements of both \u03bb1 and the RBC aggregation index (AI) while reducing unnecessary blood consumption. The \u03bb1 shows a strong correlation with viscosity and is significantly affected by syringe air compliance. The proposed AI exhibits consistent trends when compared with conventional aggregation indices. Furthermore, it exhibits temporal stability under continuous blood flow. Finally, the method is adopted to detect time-dependent changes in blood during continuous blood infusion, which demonstrates its potential as a simple, sensitive, and practical microfluidic sensor for real-time hemorheological monitoring.<\/jats:p>","DOI":"10.3390\/s26144541","type":"journal-article","created":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T06:09:09Z","timestamp":1784527749000},"page":"4541","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Pulsatile Flow-Modulation Microfluidic Sensor for Simultaneous Monitoring of Red Blood Cell Aggregation and Viscosity-Sensitive Time Constant"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5047-3012","authenticated-orcid":false,"given":"Yang Jun","family":"Kang","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Chosun University, 10, Chosundae 1-gil, Dong-gu, Gwangju 61452, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,7,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Mehri, R., Mavriplis, C., and Fenech, M. (2018). Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0199911"},{"key":"ref_2","first-page":"423","article-title":"Simulation of red blood cell aggregation in shear flow","volume":"34","author":"Lim","year":"1997","journal-title":"Biorheology"},{"key":"ref_3","first-page":"25","article-title":"Hemodynamic effects of red blood cell aggregation","volume":"45","author":"Baskurt","year":"2007","journal-title":"Indian J. Exp. Biol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"3418","DOI":"10.1182\/bloodadvances.2024015533","article-title":"Red blood cell aggregation within a blood clot causes platelet-independent clot shrinkage","volume":"9","author":"Peshkova","year":"2025","journal-title":"Blood Adv."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"e12317","DOI":"10.1111\/micc.12317","article-title":"Influence of red blood cell aggregation on perfusion of an artificial microvascular network","volume":"24","author":"Reinhart","year":"2017","journal-title":"Microcirculation"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"23","DOI":"10.3233\/CH-2012-1573","article-title":"Erythrocyte aggregation: Basic aspects and clinical importance","volume":"53","author":"Baskurt","year":"2013","journal-title":"Clin. Hemorheol. Microcirc."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.3324\/haematol.2008.005371","article-title":"Red blood cell aggregation, aggregate strength and oxygen transport potential of blood are abnormal in both homozygous sickle cell anemia and sickle-hemoglobin C disease","volume":"94","author":"Tripette","year":"2009","journal-title":"Haematologica"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"eadj6423","DOI":"10.1126\/sciadv.adj6423","article-title":"Marginated aberrant red blood cells induce pathologic vascular stress fluctuations in a computational model of hematologic disorders","volume":"9","author":"Cheng","year":"2023","journal-title":"Sci. Adv."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Bernhardt, I., and Kaestner, L. (2025). Historical View and Some Unsolved Problems in Red Blood Cell Membrane Research. Front. Biosci., 30.","DOI":"10.31083\/FBL25331"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1038\/s41598-023-49849-w","article-title":"Partitioning of dense RBC suspensions in single microfluidic bifurcations: Role of cell deformability and bifurcation angle","volume":"14","author":"Stathoulopoulos","year":"2024","journal-title":"Sci. Rep."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1002\/ajh.26440","article-title":"Increased blood viscosity and red blood cell aggregation in patients with COVID-19","volume":"97","author":"Nader","year":"2022","journal-title":"Am. J. Hematol."},{"key":"ref_12","first-page":"785","article-title":"Evaluation of a method to assess red blood cell aggregation","volume":"26","author":"Chabanel","year":"1989","journal-title":"Biorheology"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Kang, Y.J. (2025). Assessment of continuous flow-dependent red cell aggregation using a microfluidic chip. Appl. Sci., 15.","DOI":"10.3390\/app152111481"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"100711","DOI":"10.1016\/j.pacs.2025.100711","article-title":"Quantitative ultrasound and photoacoustic assessments of red blood cell aggregation in the human radial artery","volume":"43","author":"Bok","year":"2025","journal-title":"Photoacoustics"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"117","DOI":"10.3233\/CH-2009-1191","article-title":"A transient, microfluidic approach to the investigation of erythrocyte aggregation: The threshold shear-stress for erythrocyte disaggregation","volume":"42","author":"Shin","year":"2009","journal-title":"Clin. Hemorheol. Microcirc."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"5996","DOI":"10.1039\/D0AN00604A","article-title":"In vitro analysis of multiple blood flow determinants using red blood cell dynamics under oscillatory flow","volume":"145","author":"Isiksacan","year":"2020","journal-title":"Analyst"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3930","DOI":"10.1039\/D0LC00619J","article-title":"Vibration motor-integrated low-cost, miniaturized system for rapid quantification of red blood cell aggregation","volume":"20","author":"Namgung","year":"2020","journal-title":"Lab Chip"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"197","DOI":"10.3233\/CH-2009-1172","article-title":"Measurement of erythrocyte aggregation in a microchip stirring system by light transmission","volume":"41","author":"Shin","year":"2009","journal-title":"Clin. Hemorheol. Microcirc."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"38049","DOI":"10.1038\/s41598-025-21864-z","article-title":"Erythrocyte aggregation kinetics for studying the vascular phase of inflammation in patients with suspected acute coronary syndrome or acute stroke","volume":"15","author":"Charansonney","year":"2025","journal-title":"Sci. Rep."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Wen, J., Wan, N., Bao, H., and Li, J. (2019). Quantitative measurement and evaluation of red blood cell aggregation in normal blood based on a modified Hanai equation. Sensors, 19.","DOI":"10.3390\/s19051095"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1109\/TBME.2009.2036598","article-title":"Time course of electrical impedance during red blood cell aggregation in a glass tube: Comparison with light transmittance","volume":"57","author":"Baskurt","year":"2010","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"117006","DOI":"10.1117\/1.3652712","article-title":"Wavelength selection in measuring red blood cell aggregation based on light transmittance","volume":"16","author":"Uyuklu","year":"2011","journal-title":"J. Biomed. Opt."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Antonova, N., and Khristov, K. (2025). Microrheological and microfluidic approaches for evaluation of the mechanical properties of blood cells. Appl. Sci., 15.","DOI":"10.20944\/preprints202507.1661.v1"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Alexandrova-Watanabe, A., Abadjieva, E., Ivanova, M., Gartcheva, L., Langari, A., Guenova, M., Tiankov, T., Nikolova, E.V., Krumova, S., and Todinova, S. (2025). Quantitative assessment of red blood cell disaggregation in chronic lymphocytic leukemia via software image flow analysis. Fluids, 10.","DOI":"10.3390\/fluids10070167"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"7173","DOI":"10.1038\/s41598-018-25317-8","article-title":"Significantly increased low shear rate viscosity, blood elastic modulus, and RBC aggregation in adults following cardiac surgery","volume":"8","author":"Wu","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"4348","DOI":"10.1038\/srep04348","article-title":"The plasma protein fibrinogen stabilizes clusters of red blood cells in microcapillary flows","volume":"4","author":"Brust","year":"2014","journal-title":"Sci. Rep."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"19751","DOI":"10.1038\/s41598-022-24166-w","article-title":"Relationship between red blood cell aggregation and dextran molecular mass","volume":"12","author":"Bosek","year":"2022","journal-title":"Sci. Rep."},{"key":"ref_28","first-page":"19","article-title":"The impact of measurement techniques and common effectors on red blood cell aggregation","volume":"60","author":"Chien","year":"2025","journal-title":"Biorheology"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Kang, Y.J. (2026). A microfluidic method for simultaneous assessment of blood viscosity and red blood cell aggregation during continuous syringe delivery. Sensors, 26.","DOI":"10.20944\/preprints202603.2297.v1"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Chang, Y.N., and Yao, D.J. (2024). Development of a microfluidic viscometer for non-Newtonian blood analog fluid analysis. Bioengineering, 11.","DOI":"10.3390\/bioengineering11121298"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1097\/MAT.0000000000001280","article-title":"Hemodilution increases the susceptibility of red blood cells to mechanical shear stress during in vitro hemolysis testing","volume":"67","author":"Sargent","year":"2021","journal-title":"ASAIO J."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"10503","DOI":"10.1021\/ac402505z","article-title":"Microfluidic biosensor for monitoring temporal variations of hemorheological and hemodynamic properties using an extracorporeal rat bypass loop","volume":"85","author":"Kang","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1565","DOI":"10.1039\/D1LC01133B","article-title":"Feature tracking microfluidic analysis reveals differential roles of viscosity and friction in sickle cell blood","volume":"22","author":"Szafraniec","year":"2022","journal-title":"Lab Chip"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1039\/D4AN01550A","article-title":"Measurement of fluid viscosity based on pressure-driven flow digital-printed microfluidics","volume":"150","author":"Ge","year":"2025","journal-title":"Analyst"},{"key":"ref_35","first-page":"353","article-title":"Shear-dependent aggregation characteristics of red blood cells in a pressure-driven microfluidic channel","volume":"34","author":"Shin","year":"2006","journal-title":"Clin. Hemorheol. Microcirc."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"28793","DOI":"10.1038\/s41598-024-80332-2","article-title":"Microfluidics chips fabrication techniques comparison","volume":"14","author":"Liu","year":"2024","journal-title":"Sci. Rep."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Gerlt, M.S., Laubli, N.F., Manser, M., Nelson, B.J., and Dual, J. (2021). Reduced etch lag and high aspect ratios by deep reactive ion etching (DRIE). Micromachines, 12.","DOI":"10.3390\/mi12050542"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Kang, Y.J. (2020). Experimental investigation of air compliance effect on measurement of mechanical properties of blood sample flowing in microfluidic channels. Micromachines, 11.","DOI":"10.3390\/mi11050460"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"22504","DOI":"10.1038\/s41598-021-01865-4","article-title":"Microfluidic active pressure and flow stabiliser","volume":"11","author":"Sodergren","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/j.ces.2017.12.045","article-title":"Damping hydrodynamic fluctuations in microfluidic systems","volume":"178","author":"Kalantarifard","year":"2018","journal-title":"Chem. Eng. Sci."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.cej.2012.08.083","article-title":"Experiments and simulation on a pulse dampener system for stabilizing liquid flow","volume":"210","author":"Deng","year":"2012","journal-title":"Chem. Eng. J."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Zhou, Y., Liu, J., Yan, J., Zhu, T., Guo, S., Li, S., and Li, T. (2020). Standing air bubble-based micro-hydraulic capacitors for flow stabilization in syringe pump-driven systems. Micromachines, 11.","DOI":"10.3390\/mi11040396"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"026301","DOI":"10.1103\/PhysRevE.86.026301","article-title":"Bubble-induced damping in displacement-driven microfluidic flows","volume":"86","author":"Lee","year":"2012","journal-title":"Phys. Rev. E"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"e30","DOI":"10.5334\/jors.bl","article-title":"PIVlab\u2014Towards user-friendly, affordable and accurate digital particle image velocimetry in MATLAB","volume":"2","author":"Thielicke","year":"2014","journal-title":"J. Open Res. Softw."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.1007\/s00348-010-1015-9","article-title":"Flow rate estimation in large depth-of-field micro-PIV","volume":"50","author":"Kloosterman","year":"2010","journal-title":"Exp. Fluids"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1146\/annurev-fluid-121108-145427","article-title":"Recent advances in micro-particle image velocimetry","volume":"42","author":"Wereley","year":"2010","journal-title":"Ann. Rev. Fluid Mech."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"S166","DOI":"10.1007\/s003480070018","article-title":"Out-of-focus effects on particle image visibility and correlation in microscopic particle image velocimetry","volume":"29","author":"Olsen","year":"2000","journal-title":"Exp. Fluids"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"4871","DOI":"10.1039\/D1AY00948F","article-title":"Blood rheometer based on microflow manipulation of continuous blood flows using push-and-back mechanism","volume":"13","author":"Kang","year":"2021","journal-title":"Anal. Methods"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1039\/C2LC20799K","article-title":"Design of pressure-driven microfluidic networks using electric circuit analogy","volume":"12","author":"Oh","year":"2012","journal-title":"Lab Chip"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"30441","DOI":"10.1039\/C8RA06006A","article-title":"A simple capillary viscometer based on the ideal gas law","volume":"8","author":"Bautista","year":"2018","journal-title":"RSC Adv."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1881","DOI":"10.1039\/c2lc21163g","article-title":"Fluidic low pass filter for hydrodynamic flow stabilization in microfluidic environments","volume":"12","author":"Kang","year":"2012","journal-title":"Lab Chip"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Nader, E., Skinner, S., Romana, M., Fort, R., Lemonne, N., Guillot, N., Gauthier, A., Antoine-Jonville, S., Renoux, C., and Hardy-Dessources, M.D. (2019). Blood rheology: Key parameters, impact on blood flow, role in sickle cell disease and effects of exercise. Front. Physiol., 10.","DOI":"10.3389\/fphys.2019.01329"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1810","DOI":"10.1016\/j.jbiomech.2013.05.010","article-title":"Large scale simulation of red blood cell aggregation in shear flows","volume":"46","author":"Xu","year":"2013","journal-title":"J. Biomech."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"2871","DOI":"10.1016\/j.ultrasmedbio.2017.08.005","article-title":"Protocol for robust in vivo measurements of erythrocyte aggregation using ultrasound spectroscopy","volume":"43","author":"Chayer","year":"2017","journal-title":"Ultrasound Med. Biol."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Kim, G., Jeong, S., and Kang, Y.J. (2020). Ultrasound standing wave-based cell-to-liquid separation for measuring viscosity and aggregation of blood sample. Sensors, 20.","DOI":"10.3390\/s20082284"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"3059","DOI":"10.1529\/biophysj.108.130328","article-title":"Effects of dextran molecular weight on red blood cell aggregation","volume":"95","author":"Neu","year":"2008","journal-title":"Biophys. J."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"e2307956","DOI":"10.1002\/smll.202307956","article-title":"Stopping microfluidic flow","volume":"20","author":"Sahin","year":"2024","journal-title":"Small"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1039\/b517054k","article-title":"A method for dynamic system characterization using hydraulic series resistance","volume":"6","author":"Kim","year":"2006","journal-title":"Lab Chip"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"109456","DOI":"10.1016\/j.ijmecsci.2024.109456","article-title":"Blood viscometer using capillary blood flow under disposable compliance pump","volume":"277","author":"Kang","year":"2024","journal-title":"Int. J. Mech. Sci."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"3742","DOI":"10.1039\/c1lc20658c","article-title":"Acoustofluidics 1: Governing equations in microfluidics","volume":"11","author":"Bruus","year":"2011","journal-title":"Lab Chip"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"044114","DOI":"10.1063\/1.4892037","article-title":"Microfluidic-based measurement of erythrocyte sedimentation rate for biophysical assessment of blood in an in vivo malaria-infected mouse","volume":"8","author":"Kang","year":"2014","journal-title":"Biomicrofluidics"},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Kang, Y.J., and Kim, B.J. (2018). Multiple and Periodic Measurement of RBC Aggregation and ESR in Parallel Microfluidic Channels under On-Off Blood Flow Control. Micromachines, 9.","DOI":"10.3390\/mi9070318"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"024110","DOI":"10.1063\/1.4917023","article-title":"Microfluidic-based speckle analysis for sensitive measurement of erythrocyte aggregation: A comparison of four methods for detection of elevated erythrocyte aggregation in diabetic rat blood","volume":"9","author":"Yeom","year":"2015","journal-title":"Biomicrofluidics"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1016\/j.crhy.2013.04.004","article-title":"Aggregation of red blood cells: From rouleaux to clot formation","volume":"14","author":"Wagner","year":"2013","journal-title":"C. R. Phys."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"073317","DOI":"10.1063\/5.0057415","article-title":"Effects of syringe pump fluctuations on cell-free layer in hydrodynamic separation microfluidic devices","volume":"33","author":"Haque","year":"2021","journal-title":"Phys. Fluids"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"3285","DOI":"10.1021\/ie071349z","article-title":"Formula for the viscosity of a glycerol\u2212water mixture","volume":"47","author":"Cheng","year":"2008","journal-title":"Ind. Eng. Chem. Res."},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Zhbanov, A., and Yang, S. (2015). Effects of Aggregation on Blood Sedimentation and Conductivity. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0129337"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"024610","DOI":"10.1103\/PhysRevE.105.024610","article-title":"Erythrocyte sedimentation: Effect of aggregation energy on gel structure during collapse","volume":"105","author":"Dasanna","year":"2022","journal-title":"Phys. Rev. E"},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Trejo-Soto, C., and Hernandez-Machado, A. (2022). Normalization of blood viscosity according to the hematocrit and the shear rate. Micromachines, 13.","DOI":"10.3390\/mi13030357"},{"key":"ref_70","first-page":"155","article-title":"Inter-species differences in hematocrit to blood viscosity ratio","volume":"46","author":"Nemeth","year":"2009","journal-title":"Biorheology"},{"key":"ref_71","first-page":"H1770","article-title":"Blood viscosity in tube flow: Dependence on diameter and hematocrit","volume":"263","author":"Pries","year":"1992","journal-title":"Am. J. Physiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/14\/4541\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T06:10:03Z","timestamp":1784527803000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/14\/4541"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,17]]},"references-count":71,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["s26144541"],"URL":"https:\/\/doi.org\/10.3390\/s26144541","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,17]]}}}