{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T15:28:02Z","timestamp":1792682882078,"version":"4.5.0"},"reference-count":54,"publisher":"MDPI AG","issue":"16","license":[{"start":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T00:00:00Z","timestamp":1786924800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Photoplethysmography-derived pulse rate variability (PPG-derived PRV) is increasingly used in wearable and camera-based biomedical sensors as a low-burden alternative to electrocardiography-derived heart rate variability (ECG-derived HRV), but its agreement with ECG-derived measurements remains uncertain. This systematic review and meta-analysis evaluated the accuracy of PPG-derived PRV compared with ECG-derived HRV in healthy or apparently healthy non-clinical populations, focusing on the root mean square of successive differences (RMSSD) and the standard deviation of normal-to-normal intervals (SDNN). Forty-three studies were included in the qualitative synthesis; 33 were summarized narratively, and 10 unique studies provided sufficient data for quantitative synthesis. Eight studies contributed to each RMSSD and SDNN meta-analysis. The pooled absolute standardized error was 0.188 (95% CI: 0.066 to 0.309; I2 = 11.69%) for RMSSD and 0.134 (95% CI: 0.014 to 0.255; I2 = 0%) for SDNN. Sensitivity analyses supported the robustness of RMSSD findings, whereas SDNN estimates were directionally stable but less robust in statistical significance. Because the quantitative synthesis included only 10 studies and was based predominantly on selected resting or controlled conditions, the pooled estimates should not be generalized to sleep, exercise, stress, or free-living settings or interpreted as evidence of interchangeability.<\/jats:p>","DOI":"10.3390\/s26165192","type":"journal-article","created":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T11:00:05Z","timestamp":1786964405000},"page":"5192","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Accuracy of Photoplethysmography-Derived Pulse Rate Variability Compared with Electrocardiography-Derived Heart Rate Variability: A Systematic Review and Meta-Analysis"],"prefix":"10.3390","volume":"26","author":[{"given":"Shiwen","family":"Xu","sequence":"first","affiliation":[{"name":"School of Physical Education, Henan Normal University, Xinxiang 453007, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Liu","sequence":"additional","affiliation":[{"name":"School of Physical Education, Shangqiu Normal University, Shangqiu 476000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengliang","family":"Liu","sequence":"additional","affiliation":[{"name":"School of Physical Education, Henan Normal University, Xinxiang 453007, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Su","sequence":"additional","affiliation":[{"name":"School of Physical Education, Guangdong University of Technology, Guangzhou 510006, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhuangzhuang","family":"Gu","sequence":"additional","affiliation":[{"name":"School of Physical Education, Henan Normal University, Xinxiang 453007, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,8,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1093\/oxfordjournals.eurheartj.a014868","article-title":"Heart rate variability: Standards of measurement, physiological interpretation and clinical use","volume":"17","author":"Malik","year":"1996","journal-title":"Eur. Heart J."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Laborde, S., Mosley, E., and Thayer, J.F. (2017). Heart rate variability and cardiac vagal tone in psychophysiological research: Recommendations for experiment planning, data analysis, and data reporting. Front. Psychol., 8.","DOI":"10.3389\/fpsyg.2017.00213"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1007\/s40279-019-01061-5","article-title":"The accuracy of acquiring heart rate variability from portable devices: A systematic review and meta-analysis","volume":"49","author":"Dobbs","year":"2019","journal-title":"Sports Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1007\/s00421-018-3808-0","article-title":"Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions","volume":"118","author":"Caminal","year":"2018","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"896","DOI":"10.1123\/ijspp.2019-0406","article-title":"Validity of a Smartphone Application and Chest Strap for Recording RR Intervals at Rest in Athletes","volume":"15","author":"Pereira","year":"2020","journal-title":"Int. J. Sports Physiol. Perform."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1007\/s12283-022-00371-8","article-title":"Examining weekly heart rate variability changes: A comparison between monitoring methods","volume":"25","year":"2022","journal-title":"Sports Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"07TR01","DOI":"10.1088\/1361-6579\/ab998c","article-title":"Pulse rate variability in cardiovascular health: A review on its applications and relationship with heart rate variability","volume":"41","author":"May","year":"2020","journal-title":"Physiol. Meas."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.ijcard.2012.03.119","article-title":"How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram","volume":"166","author":"Vagedes","year":"2013","journal-title":"Int. J. Cardiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"e13441","DOI":"10.1111\/psyp.13441","article-title":"Stressing the accuracy: Wrist-worn wearable sensor validation over different conditions","volume":"56","author":"Menghini","year":"2019","journal-title":"Psychophysiology"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1007\/s10877-019-00382-0","article-title":"Comparison of multiple cardiac signal acquisition technologies for heart rate variability analysis","volume":"34","author":"Charlier","year":"2020","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"14079","DOI":"10.1038\/s41598-019-50526-0","article-title":"Speckleplethysmographic (SPG) Estimation of Heart Rate Variability During an Orthostatic Challenge","volume":"9","author":"Dunn","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Burma, J.S., Griffiths, J.K., Lapointe, A.P., Oni, I.K., Soroush, A., Carere, J., Smirl, J.D., and Dunn, J.F. (2024). Heart Rate Variability and Pulse Rate Variability: Do Anatomical Location and Sampling Rate Matter?. Sensors, 24.","DOI":"10.3390\/s24072048"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: An updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.jclinepi.2010.03.002","article-title":"Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed","volume":"64","author":"Kottner","year":"2011","journal-title":"J. Clin. Epidemiol."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Lakens, D. (2013). Calculating and reporting effect sizes to facilitate cumulative science: A practical primer for t-tests and ANOVAs. Front. Psychol., 4.","DOI":"10.3389\/fpsyg.2013.00863"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1037\/1082-989X.7.1.105","article-title":"Combining effect size estimates in meta-analysis with repeated measures and independent-groups designs","volume":"7","author":"Morris","year":"2002","journal-title":"Psychol. Methods"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1","DOI":"10.18637\/jss.v036.i03","article-title":"Conducting meta-analyses in R with the metafor package","volume":"36","author":"Viechtbauer","year":"2010","journal-title":"J. Stat. Softw."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Correia, B., Dias, N., Costa, P., and P\u00eago, J.M. (2020). Validation of a wireless bluetooth photoplethysmography sensor used on the earlobe for monitoring heart rate variability features during a stress-inducing mental task in healthy individuals. Sensors, 20.","DOI":"10.3390\/s20143905"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.ijpsycho.2021.06.005","article-title":"Correspondence of parasympathetic-mediated heart rate variability derived from electrocardiogram and photoplethysmography signals in ethnically diverse adolescents","volume":"167","author":"Diehl","year":"2021","journal-title":"Int. J. Psychophysiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.ijpsycho.2022.10.003","article-title":"Validity of the Empatica E4 wristband to estimate resting-state heart rate variability in a lab-based context","volume":"182","author":"Stuyck","year":"2022","journal-title":"Int. J. Psychophysiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"e14356","DOI":"10.1111\/psyp.14356","article-title":"Pulse rate variability: An alternative to heart rate variability in adults with spinal cord injury","volume":"60","author":"Schoffl","year":"2023","journal-title":"Psychophysiology"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1097\/PSY.0000000000001236","article-title":"Validation of photoplethysmography using a mobile phone application for the assessment of heart rate variability in the context of heart rate variability biofeedback","volume":"85","author":"Huizink","year":"2023","journal-title":"Psychosom. Med."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Flatt, A.A., Blalock, A.C.E., Wade, A.N., and Riemann, B.L. (2025). Biostrap Kairos wristband versus electrocardiography for resting heart rate variability assessment. Sensors, 25.","DOI":"10.3390\/s25103165"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Coste, A., Millour, G., and Hausswirth, C. (2025). A comparative study between ECG- and PPG-based heart rate sensors for heart rate variability measurements: Influence of body position, duration, sex, and age. Sensors, 25.","DOI":"10.3390\/s25185745"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Johansson, H., Adderley, E., Clarke, S., McIntyre, P., Reilly, G., Caulfield, B., and Holden, S. (2026). An observational study of the reliability and concurrent validity of heart rate variability devices in athletes. Front. Physiol., 16.","DOI":"10.3389\/fphys.2025.1707318"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1007\/s40846-019-00468-9","article-title":"Evaluation of coherence between ECG- and PPG-derived parameters on heart rate variability and respiration in healthy volunteers with\/without controlled breathing","volume":"39","author":"Jan","year":"2019","journal-title":"J. Med. Biol. Eng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"100698","DOI":"10.1016\/j.cegh.2021.100698","article-title":"Association of heart rate variability measured by RR interval from ECG and pulse to pulse interval from photoplethysmography","volume":"10","author":"Kumar","year":"2021","journal-title":"Clin. Epidemiol. Glob. Health"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1111\/cpf.12334","article-title":"A comparison of two methods of heart rate variability assessment at high altitude","volume":"37","author":"Boos","year":"2017","journal-title":"Clin. Physiol. Funct. Imaging"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1324","DOI":"10.1123\/ijspp.2016-0668","article-title":"Comparison of Heart-Rate-Variability Recording With Smartphone Photoplethysmography, Polar H7 Chest Strap, and Electrocardiography","volume":"12","author":"Plews","year":"2017","journal-title":"Int. J. Sports Physiol. Perform."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s10916-017-0842-0","article-title":"Reliability of the Parabola Approximation Method in Heart Rate Variability Analysis Using Low-Sampling-Rate Photoplethysmography","volume":"41","author":"Baek","year":"2017","journal-title":"J. Med. Syst."},{"key":"ref_32","first-page":"4038034","article-title":"Analysis of a Pulse Rate Variability Measurement Using a Smartphone Camera","volume":"2018","author":"Fidrich","year":"2018","journal-title":"J. Healthc. Eng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1007\/s11517-019-01957-4","article-title":"Comparison of short-term heart rate variability indexes evaluated through electrocardiographic and continuous blood pressure monitoring","volume":"57","author":"Pernice","year":"2019","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"04NT01","DOI":"10.1088\/1361-6579\/ab840a","article-title":"Feasible assessment of recovery and cardiovascular health: Accuracy of nocturnal HR and HRV assessed via ring PPG in comparison to medical grade ECG","volume":"41","author":"Kinnunen","year":"2020","journal-title":"Physiol. Meas."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Holmes, C.J., Fedewa, M.V., Winchester, L.J., MacDonald, H.V., Wind, S.A., and Esco, M.R. (2020). Validity of Smartphone Heart Rate Variability Pre- and Post-Resistance Exercise. Sensors, 20.","DOI":"10.3390\/s20205738"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Killian, J.M., Radin, R.M., Gardner, C.L., Kasuske, L., Bashirelahi, K., Nathan, D., Keyser, D.O., Cellucci, C.J., Darmon, D., and Rapp, P.E. (2021). Alternative Devices for Heart Rate Variability Measures: A Comparative Test-Retest Reliability Study. Behav. Sci., 11.","DOI":"10.3390\/bs11050068"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Bellenger, C.R., Miller, D.J., Halson, S.L., Roach, G.D., and Sargent, C. (2021). Wrist-Based Photoplethysmography Assessment of Heart Rate and Heart Rate Variability: Validation of WHOOP. Sensors, 21.","DOI":"10.3390\/s21103571"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Nuuttila, O.P., Korhonen, E., Laukkanen, J., and Kyr\u00f6l\u00e4inen, H. (2021). Validity of the Wrist-Worn Polar Vantage V2 to Measure Heart Rate and Heart Rate Variability at Rest. Sensors, 22.","DOI":"10.3390\/s22010137"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"e27487","DOI":"10.2196\/27487","article-title":"Accuracy Assessment of Oura Ring Nocturnal Heart Rate and Heart Rate Variability in Comparison With Electrocardiography in Time and Frequency Domains: Comprehensive Analysis","volume":"24","author":"Cao","year":"2022","journal-title":"J. Med. Internet Res."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"89","DOI":"10.2478\/joeb-2021-0012","article-title":"Estimation of Heart Rate Variability from Finger Photoplethysmography During Rest, Mild Exercise and Mild Mental Stress","volume":"12","author":"Singstad","year":"2021","journal-title":"J. Electr. Bioimpedance"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"106696","DOI":"10.1016\/j.cmpb.2022.106696","article-title":"Validity and reliability of different smartphones applications to measure HRV during short and ultra-short measurements in elite athletes","volume":"217","author":"Zabala","year":"2022","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1049\/htl2.12023","article-title":"Effectiveness of the heartbeat interval error and compensation method on heart rate variability analysis","volume":"9","author":"Shintomi","year":"2022","journal-title":"Healthc. Technol. Lett."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Miller, D.J., Sargent, C., and Roach, G.D. (2022). A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults. Sensors, 22.","DOI":"10.3390\/s22166317"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Taoum, A., Bisiaux, A., Tilquin, F., Le Guillou, Y., and Carrault, G. (2022). Validity of Ultra-Short-Term HRV Analysis Using PPG-A Preliminary Study. Sensors, 22.","DOI":"10.3390\/s22207995"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Sarhaddi, F., Kazemi, K., Azimi, I., Cao, R., Niela-Vil\u00e9n, H., Axelin, A., Liljeberg, P., and Rahmani, A.M. (2022). A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability. PLoS ONE, 17.","DOI":"10.1101\/2022.04.29.22274461"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Himariotis, A.T., Coffey, K.F., Noel, S.E., and Cornell, D.J. (2022). Validity of a Smartphone Application in Calculating Measures of Heart Rate Variability. Sensors, 22.","DOI":"10.3390\/s22249883"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Costantini, S., Chiappini, M., Malerba, G., Dei, C., Falivene, A., Arlati, S., Colombo, V., Biffi, E., and Storm, F.A. (2023). Wrist-Worn Sensor Validation for Heart Rate Variability and Electrodermal Activity Detection in a Stressful Driving Environment. Sensors, 23.","DOI":"10.3390\/s23208423"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Vondrasek, J.D., Riemann, B.L., Grosicki, G.J., and Flatt, A.A. (2023). Validity and Efficacy of the Elite HRV Smartphone Application during Slow-Paced Breathing. Sensors, 23.","DOI":"10.21203\/rs.3.rs-3139466\/v1"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"035002","DOI":"10.1088\/1361-6579\/ad2c14","article-title":"Quantifying the accuracy of inter-beat intervals acquired from consumer-grade photoplethysmography wristbands using an electrocardiogram-aided information-based similarity approach","volume":"45","author":"Cui","year":"2024","journal-title":"Physiol. Meas."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"O\u2019Grady, B., Lambe, R., Baldwin, M., Acheson, T., and Doherty, C. (2024). The Validity of Apple Watch Series 9 and Ultra 2 for Serial Measurements of Heart Rate Variability and Resting Heart Rate. Sensors, 24.","DOI":"10.3390\/s24196220"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Rehman, R.Z.U., Chatterjee, M., Manyakov, N.V., Daans, M., Jackson, A., O\u2019Brisky, A., Telesky, T., Smets, S., Berghmans, P.J., and Yang, D. (2024). Assessment of Physiological Signals from Photoplethysmography Sensors Compared to an Electrocardiogram Sensor: A Validation Study in Daily Life. Sensors, 24.","DOI":"10.3390\/s24216826"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Liang, T., Yilmaz, G., and Soon, C.S. (2024). Deriving Accurate Nocturnal Heart Rate, rMSSD and Frequency HRV from the Oura Ring. Sensors, 24.","DOI":"10.3390\/s24237475"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Rogers, D.W., Himariotis, A.T., Sherriff, T.J., Proulx, Q.J., Duong, M.T., Noel, S.E., and Cornell, D.J. (2025). Test-Retest Reliability and Concurrent Validity of Photoplethysmography Finger Sensor to Collect Measures of Heart Rate Variability. Sports, 13.","DOI":"10.3390\/sports13020029"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1109\/TIM.2017.2786677","article-title":"A yellow\u2013orange wavelength-based short-term heart rate variability measurement scheme for wrist-based wearables","volume":"67","author":"Mohapatra","year":"2018","journal-title":"IEEE Trans. Instrum. Meas."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/16\/5192\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T11:08:58Z","timestamp":1786964938000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/16\/5192"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,17]]},"references-count":54,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["s26165192"],"URL":"https:\/\/doi.org\/10.3390\/s26165192","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,17]]}}}