{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T13:08:52Z","timestamp":1788786532022,"version":"build-2803163510"},"reference-count":91,"publisher":"MDPI AG","issue":"17","license":[{"start":{"date-parts":[[2026,9,6]],"date-time":"2026-09-06T00:00:00Z","timestamp":1788652800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This review evaluates urinary catheter sensors designed to warn of crystalline encrustation and blockage or to monitor infection-related microbial, interfacial, and host-response states. A source-to-claim framework links each measured state and sampling compartment with its readout, reference endpoint, and supportable clinical claim. The analysis also considers whether catheter integration preserves the relationship between source, readout, and claim. pH-responsive systems have the strongest human feasibility evidence, although the studies are small, use different sampling configurations, and include few blockage events. Evidence for urease sensing is confined to analytical studies and controlled in vitro experiments. Mineral-deposition and hydraulic approaches rely mainly on catheter models or adjacent-device studies. Most infection-related platforms are sample-based assays, prototypes, or short-duration systems that measure clinically non-equivalent states. Analyte detection alone cannot establish a diagnosis or predict a later event in either application. Interpretation also changes with sensor location and with the effects of transport, fouling, and mechanical loading on the recognition interface. Translation requires validation over complete catheter episodes against an endpoint matched to the intended claim. An additional channel is warranted only if it resolves a prespecified uncertainty and improves clinically relevant performance against a fixed comparator.<\/jats:p>","DOI":"10.3390\/s26175659","type":"journal-article","created":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T12:12:25Z","timestamp":1788783145000},"page":"5659","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Sensing in Urinary Catheter Systems: From Measurands and Signal Fidelity to Supportable Clinical Claims"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3243-5490","authenticated-orcid":false,"given":"Shuai","family":"Zhang","sequence":"first","affiliation":[{"name":"School of Pharmacy, Queen\u2019s University Belfast, Belfast BT9 7BL, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e03913","DOI":"10.1002\/adhm.202503913","article-title":"Smart Catheters for Diagnosis, Monitoring, and Therapy","volume":"15","author":"Tarman","year":"2026","journal-title":"Adv. Healthc. Mater."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1186\/2047-2994-3-23","article-title":"Catheter associated urinary tract infections","volume":"3","author":"Nicolle","year":"2014","journal-title":"Antimicrob. Resist. Infect. Control"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"574","DOI":"10.12968\/bjcn.2002.7.11.10888","article-title":"Managing recurrent urinary catheter encrustation","volume":"7","author":"Getliffe","year":"2002","journal-title":"Br. J. Community Nurs."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1038\/sc.2010.32","article-title":"The encrustation and blockage of long-term indwelling bladder catheters: A way forward in prevention and control","volume":"48","author":"Stickler","year":"2010","journal-title":"Spinal Cord"},{"key":"ref_5","unstructured":"National Institute for Health and Care Excellence (2026, August 07). Urinary Tract Infection (Catheter-Associated): Antimicrobial Prescribing. NICE Guideline NG113. Published 23 November 2018, Updated May 2025. Available online: https:\/\/www.nice.org.uk\/guidance\/ng113\/chapter\/Recommendations."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"World Health Organization (2024). Global Report on Infection Prevention and Control 2024, World Health Organization. Available online: https:\/\/www.who.int\/publications\/i\/item\/9789240103986.","DOI":"10.2471\/B09195"},{"key":"ref_7","unstructured":"NHS England (2026, August 07). Antimicrobial Resistance (AMR). Available online: https:\/\/www.england.nhs.uk\/ourwork\/prevention\/antimicrobial-resistance-amr\/."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1021\/acsinfecdis.5c01146","article-title":"Host Pathogen Interactions during Catheter-Associated Urinary Tract Infections","volume":"12","author":"Kohler","year":"2026","journal-title":"ACS Infect. Dis."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"e75798","DOI":"10.7554\/eLife.75798","article-title":"Inhibiting host-protein deposition on urinary catheters reduces associated urinary tract infections","volume":"11","author":"Andersen","year":"2022","journal-title":"eLife"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2704","DOI":"10.1038\/s41467-024-46974-6","article-title":"Fibrinolytic-deficiencies predispose hosts to septicemia from a catheter-associated UTI","volume":"15","author":"Molina","year":"2024","journal-title":"Nat. Commun."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"eade7689","DOI":"10.1126\/sciadv.ade7689","article-title":"The catheterized bladder environment promotes Efg1- and Als1-dependent Candida albicans infection","volume":"9","author":"Andersen","year":"2023","journal-title":"Sci. Adv."},{"key":"ref_12","first-page":"82","article-title":"Evaluation of the appropriate time period between sampling and analyzing for automated urinalysis","volume":"26","author":"Conrad","year":"2016","journal-title":"Biochem. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"8617","DOI":"10.1038\/s41598-025-92802-2","article-title":"Continuous spectroscopic monitoring of urinary catheter output: Advancements and clinical implications","volume":"15","author":"Kuenert","year":"2025","journal-title":"Sci. Rep."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1086\/650482","article-title":"Diagnosis, Prevention, and Treatment of Catheter-Associated Urinary Tract Infection in Adults: 2009 International Clinical Practice Guidelines from the Infectious Diseases Society of America","volume":"50","author":"Hooton","year":"2010","journal-title":"Clin. Infect. Dis."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"e83","DOI":"10.1093\/cid\/ciy1121","article-title":"Clinical Practice Guideline for the Management of Asymptomatic Bacteriuria: 2019 Update by the Infectious Diseases Society of America","volume":"68","author":"Nicolle","year":"2019","journal-title":"Clin. Infect. Dis."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Schaffer, J.N., and Pearson, M.M. (2015). Proteus mirabilis and Urinary Tract Infections. Microbiol. Spectr., 3.","DOI":"10.1128\/microbiolspec.UTI-0017-2013"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"460","DOI":"10.4161\/viru.2.5.17783","article-title":"Proteus mirabilis biofilms and catheter-associated urinary tract infections","volume":"2","author":"Jacobsen","year":"2011","journal-title":"Virulence"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1046\/j.1464-410x.1999.00014.x","article-title":"The physicochemical basis of urinary catheter encrustation","volume":"83","author":"Choong","year":"1999","journal-title":"BJU Int."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1046\/j.1464-410x.2000.00343.x","article-title":"The dissolution of urinary catheter encrustation","volume":"85","author":"Getliffe","year":"2000","journal-title":"BJU Int."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1099\/jmm.0.46404-0","article-title":"Modulation of crystalline Proteus mirabilis biofilm development on urinary catheters","volume":"55","author":"Stickler","year":"2006","journal-title":"J. Med. Microbiol."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Armbruster, C.E., Mobley, H.L.T., and Pearson, M.M. (2018). Pathogenesis of Proteus mirabilis infection. EcoSal. Plus, 8.","DOI":"10.1128\/ecosalplus.esp-0009-2017"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.tim.2016.11.015","article-title":"From Catheter to Kidney Stone: The Uropathogenic Lifestyle of Proteus mirabilis","volume":"25","author":"Norsworthy","year":"2017","journal-title":"Trends Microbiol."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Wasfi, R., Hamed, S.M., Amer, M.A., and Fahmy, L.I. (2020). Proteus mirabilis Biofilm: Development and Therapeutic Strategies. Front. Cell. Infect. Microbiol., 10.","DOI":"10.3389\/fcimb.2020.00414"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1038\/s41467-023-44095-0","article-title":"Microbial co-occurrences on catheters from long-term catheterized patients","volume":"15","author":"Nye","year":"2024","journal-title":"Nat. Commun."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"9678","DOI":"10.1038\/s41467-025-64661-y","article-title":"Harnessing microbial-derived metabolites in the urinary tract to prevent infection induced catheter encrustation","volume":"16","author":"Guterman","year":"2025","journal-title":"Nat. Commun."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.bios.2016.02.059","article-title":"An in-situ infection detection sensor coating for urinary catheters","volume":"81","author":"Milo","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1801242","DOI":"10.1002\/admi.201801242","article-title":"Theranostic Infection-Responsive Coating to In Situ Detect and Prevent Urinary Catheter Blockage","volume":"5","author":"Zhou","year":"2018","journal-title":"Adv. Mater. Interfaces"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.cnc.2025.02.005","article-title":"Point-of-Care Sensors and Medical Internet-of-Things Technologies to Manage Catheter-Associated Urinary Tract Infections in the Intensive Care Unit","volume":"37","author":"Zandi","year":"2025","journal-title":"Crit. Care Nurs. Clin. N. Am."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"lxad121","DOI":"10.1093\/jambio\/lxad121","article-title":"Infection responsive coatings to reduce biofilm formation and encrustation of urinary catheters","volume":"134","author":"Slate","year":"2023","journal-title":"J. Appl. Microbiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"102191","DOI":"10.1016\/j.mtbio.2025.102191","article-title":"Smart bacteria-responsive coatings for combating catheter-associated urinary tract infections","volume":"34","author":"Liu","year":"2025","journal-title":"Mater. Today Bio"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"102225","DOI":"10.1016\/j.mtbio.2025.102225","article-title":"Urinary catheters: State of the art and future perspectives\u2014A narrative review","volume":"34","author":"Skok","year":"2025","journal-title":"Mater. Today Bio"},{"key":"ref_32","unstructured":"FDA-NIH Biomarker Working Group (2026, August 07). BEST (Biomarkers, EndpointS, and Other Tools) Resource. Food and Drug Administration and National Institutes of Health, 2016-Present, Available online: https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK326791\/."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"h5527","DOI":"10.1136\/bmj.h5527","article-title":"STARD 2015: An updated list of essential items for reporting diagnostic accuracy studies","volume":"351","author":"Bossuyt","year":"2015","journal-title":"BMJ"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1136\/bmj.332.7549.1089","article-title":"Comparative accuracy: Assessing new tests against existing diagnostic pathways","volume":"332","author":"Bossuyt","year":"2006","journal-title":"BMJ"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1636","DOI":"10.1373\/clinchem.2012.182576","article-title":"Beyond diagnostic accuracy: The clinical utility of diagnostic tests","volume":"58","author":"Bossuyt","year":"2012","journal-title":"Clin. Chem."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"i2372","DOI":"10.1136\/bmj.i2372","article-title":"IDEAL-D: A rational framework for evaluating and regulating the use of medical devices","volume":"353","author":"Sedrakyan","year":"2016","journal-title":"BMJ"},{"key":"ref_37","unstructured":"(2025). Biological Evaluation of Medical Devices\u2014Part 1: Requirements and General Principles for the Evaluation of Biological Safety Within a Risk Management Process (Standard No. ISO 10993-1:2025)."},{"key":"ref_38","unstructured":"U.S. Food and Drug Administration (2026, August 07). Use of International Standard ISO 10993-1, \u201cBiological Evaluation of Medical Devices\u2014Part 1: Evaluation and Testing Within a Risk Management Process\u201d: Guidance for Industry and Food and Drug Administration Staff, Available online: https:\/\/www.fda.gov\/media\/142959\/download."},{"key":"ref_39","unstructured":"(2023). Packaging for Terminally Sterilized Medical Devices\u2014Part 1: Requirements for Materials, Sterile Barrier Systems and Packaging Systems\u2014Amendment 1: Application of Risk Management (Standard No. ISO 11607-1:2019\/Amd 1:2023)."},{"key":"ref_40","unstructured":"(2019). Medical Devices\u2014Application of Risk Management to Medical Devices (Standard No. ISO 14971:2019)."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Heylen, R.A., Mercer-Chalmers, J., Morton, A., Urie, J., Jefferies, E., Patenall, B.L., Laabei, M., and Jenkins, A.T.A. (2022). Pilot Clinical Trial to test the function of a Diagnostic Sensor in predicting Impending Urinary Catheter Blockage in Long-term Catheterized Patients. medRxiv.","DOI":"10.1101\/2022.10.25.22281351"},{"key":"ref_42","unstructured":"ISRCTN Registry (2026, August 07). ISRCTN51644058: A Study to Test a Sensor for Giving Early Warning of Urinary Catheter Blockage. Overall Study Status: Completed; Results Available. Available online: https:\/\/www.isrctn.com\/ISRCTN51644058."},{"key":"ref_43","unstructured":"ClinicalTrials.gov (2026, August 07). NCT04315129: Smart Catheter: A Novel Biosensor for Early Detection of Catheter-Associated Urinary Tract Infection. Status: Completed; Actual Enrolment 100; No Results Posted, Available online: https:\/\/clinicaltrials.gov\/study\/NCT04315129."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1021\/jacs.6b11077","article-title":"Luminescent Lanthanide Cyclen-Based Enzymatic Assay Capable of Diagnosing the Onset of Catheter-Associated Urinary Tract Infections Both in Solution and within Polymeric Hydrogels","volume":"139","author":"Surender","year":"2017","journal-title":"J. Am. Chem. Soc."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"20578","DOI":"10.1021\/acs.analchem.4c05182","article-title":"Fluorescent Probe for the pH-Independent Rapid and Sensitive Direct Detection of Urease-Producing Bacteria","volume":"96","author":"Albrich","year":"2024","journal-title":"Anal. Chem."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Duran Ramirez, J.M., Gomez, J., Obernuefemann, C.L.P., Gualberto, N.C., and Walker, J.N. (2022). Semi-Quantitative Assay to Measure Urease Activity by Urinary Catheter-Associated Uropathogens. Front. Cell. Infect. Microbiol., 12.","DOI":"10.3389\/fcimb.2022.859093"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1128\/JCM.44.4.1540-1542.2006","article-title":"A sensor to detect the early stages in the development of crystalline Proteus mirabilis biofilm on indwelling bladder catheters","volume":"44","author":"Stickler","year":"2006","journal-title":"J. Clin. Microbiol."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1002\/jbm.b.31930","article-title":"Development of an \u201cearly warning\u201d sensor for encrustation of urinary catheters following Proteus infection","volume":"100B","author":"Malic","year":"2012","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1021\/acssensors.7b00861","article-title":"Development of an Infection-Responsive Fluorescent Sensor for the Early Detection of Urinary Catheter Blockage","volume":"3","author":"Milo","year":"2018","journal-title":"ACS Sens."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"113775","DOI":"10.1016\/j.bios.2021.113775","article-title":"Optimisation of a lozenge-based sensor for detecting impending blockage of urinary catheters","volume":"197","author":"Heylen","year":"2022","journal-title":"Biosens. Bioelectron."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"148512","DOI":"10.1016\/j.ijbiomac.2025.148512","article-title":"Smart colorimetric label based on chitosan-grafted cresol red for early detection of catheter blockage and infection through urinary pH monitoring","volume":"332","author":"Keawdoungdee","year":"2025","journal-title":"Int. J. Biol. Macromol."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1111\/j.1464-410X.2006.06562.x","article-title":"A clinical assessment of the performance of a sensor to detect crystalline biofilm formation on indwelling bladder catheters","volume":"98","author":"Stickler","year":"2006","journal-title":"BJU Int."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1111\/bju.12577","article-title":"A clinical evaluation of a sensor to detect blockage due to crystalline biofilm formation on indwelling urinary catheters","volume":"114","author":"Long","year":"2014","journal-title":"BJU Int."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"5403","DOI":"10.1039\/C7TB01302G","article-title":"Prevention of encrustation and blockage of urinary catheters by Proteus mirabilis via pH-triggered release of bacteriophage","volume":"5","author":"Milo","year":"2017","journal-title":"J. Mater. Chem. B"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1021\/acs.analchem.7b04047","article-title":"Real-time monitoring of urinary encrustation using a quartz crystal microbalance","volume":"90","author":"Abadian","year":"2018","journal-title":"Anal. Chem."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"17429","DOI":"10.1038\/s41598-021-97026-8","article-title":"Automated versus manual urine output monitoring in the intensive care unit","volume":"11","author":"Minor","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1007\/s12471-026-02038-6","article-title":"Automated monitoring of urine output in hospitalized patients with indwelling urinary catheters: A clinical evaluation on the cardiology ward","volume":"34","author":"Perdeck","year":"2026","journal-title":"Neth. Heart J."},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Hota, P., Pandian, A.S., Dom\u00ednguez, R.E., Mo, M., Fu, B., Miranda, S., Cay-Durgun, P., Sirganagari, D., Serhan, M., and Serhan, P. (2026). Development and Validation of an Optical Sensor-Based Automated Urine Flow Meter for Real-Time Patient Monitoring. Sensors, 26.","DOI":"10.3390\/s26030849"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"2238","DOI":"10.1053\/j.jvca.2024.06.021","article-title":"Continuous Urine Output-Based Alert Identifies Cardiac Surgery-associated Acute Kidney Injury Earlier Than Serum Creatinine: A Prospective and Retrospective Observational Study","volume":"38","author":"Moll","year":"2024","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"Iacubovici, L., Karol, D., Baar, Y., Beri, A., Herzberg, H., Zarour, S., Goren, O., and Cohen, B. (2023). Assessment of Intra-Abdominal Pressure with a Novel Continuous Bladder Pressure Monitor\u2014A Clinical Validation Study. Life, 13.","DOI":"10.3390\/life13020384"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1186\/s13017-025-00644-0","article-title":"Variation and accuracy of intra-abdominal pressure measurement in different body positions: A prospective study","volume":"20","author":"Tayebi","year":"2025","journal-title":"World J. Emerg. Surg."},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Glienke, M., Krumnau, A., Reichelt, A.C., Reis, G., Steiner, C., Pohlmann, P.F., Dressler, F.F., Gratzke, C., Miernik, A., and Sch\u00f6b, D.S. (2025). Real-time digital monitoring of continuous bladder irrigation: Clinical evaluation of a sensor-based system for hematuria and catheter-associated events. Front. Digit. Health, 7.","DOI":"10.3389\/fdgth.2025.1634537"},{"key":"ref_63","unstructured":"(2018). Sterile Urethral Catheters for Single Use (Standard No. ISO 20696:2018). Available online: https:\/\/www.iso.org\/standard\/68854.html."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"136990","DOI":"10.1016\/j.snb.2024.136990","article-title":"Stimulus responsive wireless sensor integrated smart urine bag for early detection of catheter-associated infections","volume":"426","author":"Rana","year":"2025","journal-title":"Sens. Actuators B Chem."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"1712","DOI":"10.1021\/acssensors.2c00439","article-title":"S-Nitrosothiol-Impregnated Silicone Catheter for Colorimetric Sensing of Indole and E. coli: Toward On-Body Detection of Urinary Tract Infections","volume":"7","author":"Brady","year":"2022","journal-title":"ACS Sens."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"117539","DOI":"10.1016\/j.bios.2025.117539","article-title":"An integrated wearable fluorescence sensor for E. coli detection in catheter bags","volume":"283","author":"Xu","year":"2025","journal-title":"Biosens. Bioelectron."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"14679","DOI":"10.1021\/acs.analchem.4c03617","article-title":"Field-Deployable Colorimetric Array for On-Site Diagnosis of Urinary Tract Infection and Identification of Causative Pathogens","volume":"96","author":"Li","year":"2024","journal-title":"Anal. Chem."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1021\/acsmeasuresciau.5c00187","article-title":"Integrated iPRISM Direct-on-Urine Platform for Rapid UTI Diagnosis in a Double-Blind Clinical Trial","volume":"6","author":"Jiang","year":"2026","journal-title":"ACS Meas. Sci. Au"},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1109\/TBME.2018.2872896","article-title":"Flexible platform for in situ impedimetric detection and bioelectric effect treatment of Escherichia coli biofilms","volume":"66","author":"Huiszoon","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"3241","DOI":"10.1109\/TBME.2021.3066995","article-title":"Integrated System for Bacterial Detection and Biofilm Treatment on Indwelling Urinary Catheters","volume":"68","author":"Huiszoon","year":"2021","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"Huiszoon, R.C., Chu, S., Beardslee, L.A., Rajasekaran, P.R., Bentley, W.E., and Ghodssi, R. (2019, January 23\u201327). In situ sensor electrode patterning on urinary catheters towards infection prevention. Proceedings of the 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems and Eurosensors XXXIII, Berlin, Germany.","DOI":"10.1109\/TRANSDUCERS.2019.8808470"},{"key":"ref_72","doi-asserted-by":"crossref","unstructured":"Oliver, L.M., Dunlop, P.S.M., Byrne, J.A., Blair, I.S., Boyle, M., McGuigan, K.G., and McAdams, E.T. (September, January 30). An impedimetric sensor for monitoring the growth of Staphylococcus epidermidis. Proceedings of the 2006 International Conference of the IEEE Engineering in Medicine and Biology Society, New York, NY, USA.","DOI":"10.1109\/IEMBS.2006.4397455"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"140520","DOI":"10.1016\/j.snb.2026.140520","article-title":"Impedance fingerprinting of biofilm formation on PEDOT:PSS electrodes enables rapid detection of biofilm-associated urinary tract infection","volume":"467","author":"Islayem","year":"2026","journal-title":"Sens. Actuators B Chem."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1038\/s41522-018-0069-y","article-title":"Rapid diagnostic assay for detection of cellulose in urine as biomarker for biofilm-related urinary tract infections","volume":"4","author":"Antypas","year":"2018","journal-title":"npj Biofilms Microbiomes"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"1877","DOI":"10.1021\/acssensors.0c01085","article-title":"Real-Time Monitoring of a Protein Biomarker","volume":"5","author":"Parolo","year":"2020","journal-title":"ACS Sens."},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Devill\u00e9, W.L., Yzermans, J.C., van Duijn, N.P., Bezemer, P.D., van der Windt, D.A., and Bouter, L.M. (2004). The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy. BMC Urol., 4.","DOI":"10.1186\/1471-2490-4-4"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"265","DOI":"10.4103\/2249-4863.154672","article-title":"Reliability of dipstick assay in predicting urinary tract infection","volume":"4","author":"Mambatta","year":"2015","journal-title":"J. Fam. Med. Prim. Care"},{"key":"ref_78","doi-asserted-by":"crossref","unstructured":"Mendes, A.F.N.S., Matela, N., Coelho, J.M.P., and Marqu\u00eas, J.T. (2025). A Spectroscopic Methodology to Early Detection of Urinary Tract Infections. Sensors, 25.","DOI":"10.3390\/s25020400"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"e03584-20","DOI":"10.1128\/mBio.03584-20","article-title":"Biofilm Development on Urinary Catheters Promotes the Appearance of Viable but Nonculturable Bacteria","volume":"12","author":"Wilks","year":"2021","journal-title":"mBio"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"055005","DOI":"10.1088\/1361-6579\/abfbb9","article-title":"Technical considerations for evaluating clinical prediction indices: A case study for predicting code blue events with MEWS","volume":"42","author":"Gadhoumi","year":"2021","journal-title":"Physiol. Meas."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1177\/0954411918790286","article-title":"An engineering approach towards a more discrete and efficient urinary drainage system","volume":"233","author":"Marzo","year":"2019","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/0195-6701(87)90009-0","article-title":"Comparison of flow rates into vented and non-vented urinary drainage bags: Possible relevance to infection","volume":"10","author":"Winterbottom","year":"1987","journal-title":"J. Hosp. Infect."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"1517","DOI":"10.1038\/s41551-025-01389-6","article-title":"A biochemical sensor with continuous extended stability in vivo","volume":"9","author":"Chen","year":"2025","journal-title":"Nat. Biomed. Eng."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1177\/0272989X06295361","article-title":"Decision curve analysis: A novel method for evaluating prediction models","volume":"26","author":"Vickers","year":"2006","journal-title":"Med. Decis. Mak."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"4230","DOI":"10.1002\/sim.9025","article-title":"Minimum sample size for external validation of a clinical prediction model with a binary outcome","volume":"40","author":"Riley","year":"2021","journal-title":"Stat. Med."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1002\/sim.9275","article-title":"Minimum sample size calculations for external validation of a clinical prediction model with a time-to-event outcome","volume":"41","author":"Riley","year":"2022","journal-title":"Stat. Med."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"e078378","DOI":"10.1136\/bmj-2023-078378","article-title":"TRIPOD+AI statement: Updated guidance for reporting clinical prediction models that use regression or machine learning methods","volume":"385","author":"Collins","year":"2024","journal-title":"BMJ"},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1097\/NNR.0000000000000071","article-title":"Self-management intervention for long-term indwelling urinary catheter users: Randomized clinical trial","volume":"64","author":"Wilde","year":"2015","journal-title":"Nurs. Res."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"e087203","DOI":"10.1136\/bmjopen-2024-087203","article-title":"CATHETER II: A randomised controlled trial comparing the clinical effectiveness of various washout policies versus no washout policy in preventing catheter-associated complications in adults living with long-term catheters","volume":"14","author":"Omar","year":"2024","journal-title":"BMJ Open"},{"key":"ref_90","unstructured":"(2020). Medical Devices\u2014Part 1: Application of Usability Engineering to Medical Devices (Standard No. IEC 62366-1:2015+A1:2020)."},{"key":"ref_91","unstructured":"U.S. Food and Drug Administration (2026, September 01). Cybersecurity in Medical Devices: Quality Management System Considerations and Content of Premarket Submissions. Guidance for Industry and Food and Drug Administration Staff, Available online: https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/cybersecurity-medical-devices-quality-management-system-considerations-and-content-premarket."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/17\/5659\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T12:21:43Z","timestamp":1788783703000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/17\/5659"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,6]]},"references-count":91,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["s26175659"],"URL":"https:\/\/doi.org\/10.3390\/s26175659","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,6]]}}}