{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T13:07:55Z","timestamp":1788959275583,"version":"build-2803163510"},"reference-count":34,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"College of Sciences and Mathematics (COSM) Seed Grant Program, Arkansas State University"},{"id":[{"id":"https:\/\/ror.org\/006pyvd89","id-type":"ROR","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Excess phosphorus loading is a major contributor to eutrophication and harmful algal blooms, creating a need for rapid, reliable, and field-deployable phosphate monitoring technologies. In this study, a novel reagent-free electrochemical sensor for orthophosphate determination was developed based on ion-transfer stripping voltammetry (ITSV) at a phosphate-selective membrane interface. The sensor consisted of a poly(vinyl chloride) (PVC)\/o-nitrophenyl octyl ether (o-NPOE) membrane containing tributyltin chloride (TBTC) as a phosphate-selective ionophore integrated with a PEDOT:PSS solid-contact transducer for efficient ion-to-electron signal conversion. Orthophosphate was quantified through the controlled transfer of H2PO4\u2212 ions across the membrane without the use of chemical reagents, enzymes, or redox mediators. Under optimized conditions, the sensor exhibited a linear response over the concentration range of 10\u2013850 \u03bcM with high linearity (R2 = 0.9955) and a limit of detection of 2.8 \u03bcM. The corresponding limit of quantification (LOQ) was 9.4 \u03bcM. Chronoamperometric measurements provided rapid concentration-dependent responses over a broader range of 5\u20131000 \u03bcM, demonstrating the potential applicability of the platform for future real-time monitoring applications. The sensor also maintained strong analytical performance in tap water samples and in the presence of chloride, sulfate, and nitrate ions, with detection limits ranging from 3.8 to 4.7 \u03bcM. To the best of our knowledge, this work represents the first demonstration of a solid-contact ITSV sensor for direct orthophosphate determination and offers a simple, low-cost, and reagent-free approach for phosphate monitoring in aqueous systems.<\/jats:p>","DOI":"10.3390\/s26185722","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T12:26:11Z","timestamp":1788956771000},"page":"5722","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Solid-Contact Ion-Transfer Stripping Voltammetric Sensor for Reagent-Free Orthophosphate Determination in Tap Water"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2448-0881","authenticated-orcid":false,"given":"Anahita","family":"Izadyar","sequence":"first","affiliation":[{"name":"Department of Chemistry and Physics, Arkansas State University, State University, P.O. Box 419, Jonesboro, AR 72467, USA"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"}]},{"given":"Scout","family":"Weatherford","sequence":"additional","affiliation":[{"name":"Department of Chemistry and Physics, Arkansas State University, State University, P.O. Box 419, Jonesboro, AR 72467, USA"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"data-curation","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-8862-1524","authenticated-orcid":false,"given":"Ezekiel","family":"McCain","sequence":"additional","affiliation":[{"name":"Department of Chemistry and Physics, Arkansas State University, State University, P.O. Box 419, Jonesboro, AR 72467, USA"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"investigation","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.hal.2008.08.006","article-title":"Eutrophication and Harmful Algal Blooms: A Scientific Consensus","volume":"8","author":"Heisler","year":"2008","journal-title":"Harmful Algae"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1021\/es801217q","article-title":"Eutrophication of U.S. Freshwaters: Analysis of Potential Economic Damages","volume":"43","author":"Dodds","year":"2009","journal-title":"Environ. Sci. Technol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1007\/s00248-012-0159-y","article-title":"Harmful Cyanobacterial Blooms: Causes, Consequences, and Controls","volume":"65","author":"Paerl","year":"2013","journal-title":"Microb. Ecol."},{"key":"ref_4","unstructured":"U.S. Environmental Protection Agency (2015). Drinking Water Health Advisory for Microcystins and Cylindrospermopsin."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Chorus, I., and Welker, M. (2021). Toxic Cyanobacteria in Water, CRC Press. [2nd ed.].","DOI":"10.1201\/9781003081449"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"356","DOI":"10.4319\/lo.2006.51.1_part_2.0356","article-title":"Recent Advances in the Understanding and Management of Eutrophication","volume":"51","author":"Schindler","year":"2006","journal-title":"Limnol. Oceanogr."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.aca.2008.06.016","article-title":"Characterisation and Quantification of Organic Phosphorus and Organic Nitrogen Components in Aquatic Systems: A Review","volume":"624","author":"Worsfold","year":"2008","journal-title":"Anal. Chim. Acta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0003-2670(00)88444-5","article-title":"A Modified Single-Solution Method for the Determination of Phosphate in Natural Waters","volume":"27","author":"Murphy","year":"1962","journal-title":"Anal. Chim. Acta"},{"key":"ref_9","unstructured":"U.S. Environmental Protection Agency (1978). Method 365.1: Determination of Phosphorus by Semi-Automated Colorimetry."},{"key":"ref_10","unstructured":"Harris, D.C., and Lucy, C.A. (2020). Quantitative Chemical Analysis, W.H. Freeman\/Macmillan Learning. [10th ed.]."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"9989","DOI":"10.1021\/acs.est.7b01581","article-title":"A Lab-on-Chip Analyzer for In Situ Measurement of Soluble Reactive Phosphate: Improved Phosphate Blue Assay and Application to Fluvial Monitoring","volume":"51","author":"Grand","year":"2017","journal-title":"Environ. Sci. Technol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"115908","DOI":"10.1016\/j.trac.2020.115908","article-title":"Recent Advances in the Determination of Phosphate in Environmental Water Samples: Insights from Practical Perspectives","volume":"127","author":"Zhu","year":"2020","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2147","DOI":"10.1351\/pac200476122147","article-title":"Electrochemistry at the Interface Between Two Immiscible Electrolyte Solutions (IUPAC Technical Report)","volume":"76","author":"Samec","year":"2004","journal-title":"Pure Appl. Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1039\/b415395m","article-title":"Nanoelectrodes, Nanoelectrode Arrays and Their Applications","volume":"129","author":"Arrigan","year":"2004","journal-title":"Analyst"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"3284","DOI":"10.1021\/acssensors.1c01035","article-title":"Amperometric Environmental Phosphate Sensors","volume":"6","author":"Lu","year":"2021","journal-title":"ACS Sens."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"He, Y., Han, C., Du, H., Ye, Y., and Tao, C. (2024). Potentiometric Phosphate Ion Sensor Based on Electrochemically Modified All-Solid-State Copper Electrode for Phosphate Ions\u2019 Detection in Real Water. Chemosensors, 12.","DOI":"10.3390\/chemosensors12040053"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Podra\u017cka, M., B\u0105czy\u0144ska, E., Kundys, M., Jele\u0144, P.S., and Witkowska Nery, E. (2018). Electronic Tongue: A Tool for All Tastes?. Biosensors, 8.","DOI":"10.3390\/bios8010003"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"3587","DOI":"10.1039\/D1QI00032B","article-title":"Turn-On Detection of Assorted Phosphates by Luminescent Chemosensors","volume":"8","author":"Kumar","year":"2021","journal-title":"Inorg. Chem. Front."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2210","DOI":"10.1002\/elan.201800279","article-title":"Stripping Voltammetry at the Interface between Two Immiscible Electrolyte Solutions: A Review Paper","volume":"30","author":"Izadyar","year":"2018","journal-title":"Electroanalysis"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2411","DOI":"10.1002\/elan.201300369","article-title":"Square-Wave Voltammetry: A Review on the Recent Progress","volume":"25","author":"Gulaboski","year":"2013","journal-title":"Electroanalysis"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1351\/PAC-CON-08-08-36","article-title":"Charge-Transfer Processes at the Interface between Hydrophobic Ionic Liquid and Water","volume":"81","author":"Samec","year":"2009","journal-title":"Pure Appl. Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"4932","DOI":"10.1021\/ac990497z","article-title":"Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers","volume":"71","author":"Bobacka","year":"1999","journal-title":"Anal. Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1021\/cr068100w","article-title":"Potentiometric Ion Sensors","volume":"108","author":"Bobacka","year":"2008","journal-title":"Chem. Rev."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"4405","DOI":"10.1039\/C9CS00587K","article-title":"Recent Advances in Solid-Contact Ion-Selective Electrodes: Functional Materials, Transduction Mechanisms, and Development Trends","volume":"49","author":"Shao","year":"2020","journal-title":"Chem. Soc. Rev."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1002\/elan.201900637","article-title":"Evaluation, Pitfalls and Recommendations for the Water Layer Test for Solid Contact Ion-Selective Electrodes","volume":"32","author":"Hambly","year":"2019","journal-title":"Electroanalysis"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"7150","DOI":"10.1021\/cr500023c","article-title":"Electrochemistry of Graphene and Related Materials","volume":"114","author":"Ambrosi","year":"2014","journal-title":"Chem. Rev."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1905968","DOI":"10.1155\/2017\/1905968","article-title":"Pencil Graphite Electrodes: A Versatile Tool in Electroanalysis","volume":"2017","author":"David","year":"2017","journal-title":"J. Anal. Methods Chem."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"19434","DOI":"10.1021\/acssuschemeng.9b04216","article-title":"Recombinant Mn Peroxidase from Corn Grain Has an Excellent Electrocatalytic Effect in a Designed Amperometric Biosensor to Detect Hydrogen Peroxide at Low Concentrations","volume":"7","author":"Izadyar","year":"2019","journal-title":"ACS Sustain. Chem. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"115387","DOI":"10.1016\/j.jelechem.2021.115387","article-title":"A Bienzymatic Amperometric Glucose Biosensor Based on Using a Novel Recombinant Mn Peroxidase from Corn and Glucose Oxidase with a Nafion Membrane","volume":"895","author":"Izadyar","year":"2021","journal-title":"J. Electroanal. Chem."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"6530","DOI":"10.1002\/jsfa.12019","article-title":"Development of a Highly Sensitive Glucose Nanocomposite Biosensor Based on Recombinant Enzyme from Corn","volume":"102","author":"Izadyar","year":"2022","journal-title":"J. Sci. Food Agric."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"102445","DOI":"10.1016\/j.bcab.2022.102445","article-title":"Electrocatalytic Effect of Recombinant Mn Peroxidase from Corn on Microbiosensors to Detect Glucose","volume":"43","author":"Izadyar","year":"2022","journal-title":"Biocatal. Agric. Biotechnol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"415","DOI":"10.13031\/2013.22633","article-title":"Evaluation of Phosphate Ion-Selective Membranes and Cobalt-Based Electrodes for Soil Nutrient Sensing","volume":"50","author":"Kim","year":"2007","journal-title":"Trans. ASABE"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2540","DOI":"10.1021\/ac00173a024","article-title":"Phosphate-Selective Polymer Membrane Electrode","volume":"60","author":"Glazier","year":"1988","journal-title":"Anal. Chem."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.talanta.2003.12.034","article-title":"Organic Tin Compounds Combined with Anionic Additives: An Ionophore System Leading to a Phosphate Ion-Selective Electrode?","volume":"63","author":"Sasaki","year":"2004","journal-title":"Talanta"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/18\/5722\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T12:33:44Z","timestamp":1788957224000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/18\/5722"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,9]]},"references-count":34,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["s26185722"],"URL":"https:\/\/doi.org\/10.3390\/s26185722","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,9]]}}}