{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T05:05:05Z","timestamp":1789707905055,"version":"4.0.1"},"reference-count":31,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2026,9,13]],"date-time":"2026-09-13T00:00:00Z","timestamp":1789257600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Zhejiang Province-Municipality Collaborative Project","award":["2026SDXT016"],"award-info":[{"award-number":["2026SDXT016"]}]},{"name":"Zhejiang Key Laboratory Project","award":["2024E10137"],"award-info":[{"award-number":["2024E10137"]}]},{"name":"Key Science and Technology Research Project of Wenzhou","award":["ZG2023032, ZG2021026"],"award-info":[{"award-number":["ZG2023032, ZG2021026"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Accurate remaining useful life (RUL) prediction of air circuit breakers (ACBs) is crucial for condition-based maintenance. However, existing data-driven prognostic methods suffer from electromechanical feature fragmentation, cross-device domain shifts, and the inability to penalize safety-critical late predictions. This study proposes an explainable RUL prediction framework via physics-informed feature fusion. Through full-lifecycle monitoring, novel indicators, including the electromechanical coupled degradation index (EMCDI) and the contact spring over-travel consumption rate (CSOCR), are introduced to decode interactive degradation cycles. To eliminate the interferences of initial manufacturing tolerances, a phase-decoupled normalization strategy empowers a random forest (RF) model to achieve cross-device transferability in a two-device proof-of-concept experiment, requiring only 50 initial operations for target calibration. Additionally, a safety-oriented asymmetric penalty score (APS) is integrated into the evaluation framework to explicitly penalize hazardous life overestimations. Experimental results demonstrate a full-lifecycle R2 of 0.9936 and a mean absolute error (MAE) of 38.5136. While the early-stage R2 of 0.6880 objectively reflects the statistical flatness of the equipment\u2019s healthy plateau, the framework maintains robust tracking capabilities across the entire lifespan, surpassing mainstream deep learning algorithms such as CNN, MLP, and LSTM. The proposed method consistently achieves a conservative, risk-averse predictive distribution for industrial reliability. Finally, model-level permutation importance analysis confirms that the RF model prioritizes physics-informed indicators rather than relying on spurious curve fitting.<\/jats:p>","DOI":"10.3390\/s26185802","type":"journal-article","created":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T10:19:41Z","timestamp":1789381181000},"page":"5802","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Explainable Remaining Useful Life Prediction of Air Circuit Breakers via Physics-Informed Electro-Mechanical Feature Fusion"],"prefix":"10.3390","volume":"26","author":[{"given":"Jiaqing","family":"Zhou","sequence":"first","affiliation":[{"name":"Zhejiang Key Laboratory of Smart Low-Voltage Apparatus and New Energy Application, Wenzhou University, Wenzhou 325035, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Chen","sequence":"additional","affiliation":[{"name":"Zhejiang Key Laboratory of Smart Low-Voltage Apparatus and New Energy Application, Wenzhou University, Wenzhou 325035, China"},{"name":"School of Mechanical Engineering, Zhejiang University, Hangzhou 310007, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jintao","family":"Chen","sequence":"additional","affiliation":[{"name":"Zhejiang Key Laboratory of Smart Low-Voltage Apparatus and New Energy Application, Wenzhou University, Wenzhou 325035, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinhao","family":"Chen","sequence":"additional","affiliation":[{"name":"Zhejiang Tengen Electric Co., Ltd., Wenzhou 325600, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3296","DOI":"10.1109\/TPWRD.2023.3272883","article-title":"A systematic review for switchgear asset management in power grids: Condition monitoring, health assessment, and maintenance strategy","volume":"38","author":"Zhou","year":"2023","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1007\/s13198-015-0405-z","article-title":"Reliability assessment and improvement of air circuit breaker (ACB) mechanism by identifying and eliminating the root causes","volume":"7","author":"Rane","year":"2016","journal-title":"Int. J. Syst. Assur. Eng. Manag."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.measurement.2017.02.017","article-title":"A data-driven prognostic approach based on statistical similarity: An application to industrial circuit breakers","volume":"108","author":"Leone","year":"2017","journal-title":"Measurement"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1109\/TPWRD.2017.2748146","article-title":"A RankBoost-based data-driven method to determine maintenance priority of circuit breakers","volume":"33","author":"Zhong","year":"2018","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_5","unstructured":"He, J., Li, Y., Yang, Q., and Liang, X. (2022). Fault diagnosis technology of low voltage circuit breaker based on multilayer perceptron. Proceedings of the 16th Annual Conference of China Electrotechnical Society, Springer Nature."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Qu, S. (2025, January 18\u201320). Fault diagnosis method for low-voltage circuit breakers based on BWO-SCN. Proceedings of the 2025 7th International Conference on Information Science, Electrical and Automation Engineering (ISEAE), Harbin, China.","DOI":"10.1109\/ISEAE64934.2025.11041917"},{"key":"ref_7","first-page":"3506611","article-title":"Vibration signal augmentation method for fault diagnosis of low-voltage circuit breaker based on W-CGAN","volume":"72","author":"Yang","year":"2023","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"106772","DOI":"10.1016\/j.ymssp.2020.106772","article-title":"Fault diagnosis model of adaptive miniature circuit breaker based on fractal theory and probabilistic neural network","volume":"142","author":"Yao","year":"2020","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"70710","DOI":"10.1109\/ACCESS.2026.3688732","article-title":"Method for matching the suction characteristics and enhancing the action reliability of the electromagnetic operating mechanism of low-voltage circuit breakers","volume":"14","author":"Han","year":"2026","journal-title":"IEEE Access"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2127","DOI":"10.1007\/s42835-025-02539-1","article-title":"Analysis of insulation material components in low-voltage circuit breakers according to degradation status","volume":"21","author":"Kang","year":"2026","journal-title":"J. Electr. Eng. Technol."},{"key":"ref_11","first-page":"e70498","article-title":"A low voltage circuit breaker switch trip circuit state detection method based on current signal characteristic extraction and bidirectional long short-term memory neural network","volume":"7","author":"Zhang","year":"2025","journal-title":"Eng. Rep."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Alsumaidaee, Y.A.M., Yaw, C.T., Koh, S.P., Tiong, S.K., Chen, C.P., and Ali, K. (2022). Review of medium-voltage switchgear fault detection in a condition-based monitoring system by using deep learning. Energies, 15.","DOI":"10.3390\/en15186762"},{"key":"ref_13","first-page":"3551111","article-title":"Life prediction for molded case circuit breakers based on BiGRU","volume":"74","author":"Zhou","year":"2025","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Ouyang, J., and Chi, C. (2023). The prediction of residual electrical life in alternating current circuit breakers based on savitzky-golay-long short-term. Sensors, 23.","DOI":"10.3390\/s23156860"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1007\/s43236-023-00706-z","article-title":"Remaining useful life prediction of circuit breaker operating mechanisms based on wavelet-enhanced dual-tree residual networks","volume":"24","author":"Wu","year":"2024","journal-title":"J. Power Electron."},{"key":"ref_16","first-page":"3517314","article-title":"Remaining useful life prediction for circuit breaker based on SM-CFE and SA-BiLSTM","volume":"72","author":"Sun","year":"2023","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_17","first-page":"3508512","article-title":"Fault diagnosis of conventional circuit breaker contact system based on time\u2013frequency analysis and improved AlexNet","volume":"70","author":"Sun","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"076120","DOI":"10.1088\/1361-6501\/adec0c","article-title":"Remaining useful life prognosis of vacuum circuit breaker mechanical performance via vibration signal feature fusion","volume":"36","author":"Zhao","year":"2025","journal-title":"Meas. Sci. Technol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"095110","DOI":"10.1088\/1361-6501\/ac727f","article-title":"On-line mechanical life prediction method for a conventional circuit breaker based on multi-parameter particle swarm optimization-support vector regression using vibration detection","volume":"33","author":"Sun","year":"2022","journal-title":"Meas. Sci. Technol."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Cathignol, A., Kluska, J., Szapiro, A., and Alberto, D. (2026, January 26\u201329). A dynamic bayesian approach for prognostics: Application to circuit breakers. Proceedings of the 2026 Annual Reliability and Maintainability Symposium (RAMS), Miramar Beach, FL, USA.","DOI":"10.1109\/RAMS50514.2026.11424456"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Zhuang, Q., Wang, Y., Liu, S., Gu, P., Cheng, Y., Kang, H., Yang, F., Cheng, S., Yang, B., and Dong, Y. (2025, January 7\u20139). Remaining useful life prognosis for circuit breaker operating mechanisms based on bayesian hierarchical deep learning. Proceedings of the 2025 12th International Forum on Electrical Engineering and Automation (IFEEA), Xi\u2019an, China.","DOI":"10.1109\/IFEEA66847.2025.11388723"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"34519","DOI":"10.1109\/JSEN.2025.3596724","article-title":"Research on mechanical performance degradation modeling and remaining useful life prognosis method of AC high-voltage circuit breakers","volume":"25","author":"Zhou","year":"2025","journal-title":"IEEE Sens. J."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"042002","DOI":"10.1088\/1361-6501\/ae319f","article-title":"Explainable AI for remaining useful life prediction in industrial systems: A survey","volume":"37","author":"Qu","year":"2026","journal-title":"Meas. Sci. Technol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"110072","DOI":"10.1016\/j.engappai.2025.110072","article-title":"Physics-informed deep learning framework for explainable remaining useful life prediction","volume":"143","author":"Kim","year":"2025","journal-title":"Eng. Appl. Artif. Intell."},{"key":"ref_25","unstructured":"Yang, Q., Bie, Z., and Yang, X. (2025). Fault diagnosis technology of circuit breaker based on multi-source signal data fusion. Proceedings of the 19th Annual Conference of China Electrotechnical Society, Springer Nature."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1051\/meca\/2026011","article-title":"Mechanical characteristic failure analysis and intelligent diagnosis method of filter bank circuit breakers in UHVDC projects","volume":"27","author":"Wang","year":"2026","journal-title":"Mech. Ind."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"040802","DOI":"10.1115\/1.4071396","article-title":"A review on the remaining useful life prediction of rotating machinery based on deep learning","volume":"26","author":"Wang","year":"2026","journal-title":"J. Comput. Inf. Sci. Eng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"120851","DOI":"10.1016\/j.measurement.2026.120851","article-title":"A probabilistic inference framework for RUL prediction: Modeling, propagation, and quantification of uncertainty","volume":"270","author":"Chen","year":"2026","journal-title":"Measurement"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1109\/TR.2023.3255786","article-title":"Run-to-failure relay dataset for predictive maintenance research with machine learning","volume":"73","author":"Winkel","year":"2024","journal-title":"IEEE Trans. Reliab."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Wang, Y., Yan, J., Zhang, Z., Wang, J., Geng, Y., and Srinivasan, D. (2026). Few-shot mechanical fault diagnosis of high-voltage circuit breakers using prior knowledge-constrained wavelet-based multi-frequency feature fusion. IEEE Trans. Ind. Appl., 1\u201311.","DOI":"10.1109\/TIA.2026.3711620"},{"key":"ref_31","unstructured":"(2020). Low-Voltage Switchgear and Control Gear\u2014Part 2: Circuit-Breakers (Standard No. GB\/T 14048.2-2020)."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/18\/5802\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T04:30:39Z","timestamp":1789705839000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/18\/5802"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,13]]},"references-count":31,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["s26185802"],"URL":"https:\/\/doi.org\/10.3390\/s26185802","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,13]]}}}