{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T11:56:00Z","timestamp":1790769360634,"version":"4.1.0"},"reference-count":42,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Three-dimensional gait analysis (3DGA) in patients undergoing total hip and knee arthroplasty (THA and TKA, respectively) is impractical for widespread clinical use. This study evaluated the Azure Kinect, combined with the Motognosis AMSA software (AK-M), for the assessment of selected clinically relevant gait parameters in THA and TKA patients compared with reference 3DGA. Twenty participants (10 THA, 10 TKA) were simultaneously assessed using AK-M and Qualisys 3DGA while walking along an 8 m walkway. Discrete peaks of sixteen bilateral gait parameters were compared using Bland\u2013Altman mean bias and 95% limits of agreement (LOAs), with ICC(3,1) as a complementary measure of relative consistency. Maximum hip kinematics and knee extension demonstrated low mean bias. In contrast, maximum knee flexion, knee range of motion, and step length demonstrated larger mean bias and wider LOAs. Cadence and gait speed demonstrated the lowest bias and narrowest LOAs. ICC(3,1) values ranged from 0.84 to 0.95. AK-M showed parameter-specific agreement with 3DGA, supporting preliminary concurrent validity for simplified assessment of selected discrete gait outcomes. Wider LOAs for other parameters identify areas requiring further technical refinement and clinical interpretation. These findings apply to the combined arthroplasty cohort and should not be interpreted as separate THA and TKA cohorts.<\/jats:p>","DOI":"10.3390\/s26196204","type":"journal-article","created":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T10:59:25Z","timestamp":1790765965000},"page":"6204","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Preliminary Concurrent Validation of a Portable Markerless Motion Capture System Against Three-Dimensional Gait Analysis Following Total Hip and Knee Arthroplasty"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-1439-473X","authenticated-orcid":false,"given":"Mark","family":"Abdelnour","sequence":"first","affiliation":[{"name":"Surgical and Interventional Sciences, Department of Surgery, McGill University, Montreal, QC H3G 1A4, Canada"},{"name":"Division of Orthopaedic Surgery, Department of Surgery, McGill University, 1650 Cedar Avenue, Montreal, QC H3G 1A4, Canada"},{"name":"Jo Miller Orthopaedic Research Laboratory, Montreal General Hospital, Montreal, QC H3G 1A4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9700-4523","authenticated-orcid":false,"given":"Adam","family":"Hart","sequence":"additional","affiliation":[{"name":"Surgical and Interventional Sciences, Department of Surgery, McGill University, Montreal, QC H3G 1A4, Canada"},{"name":"Division of Orthopaedic Surgery, Department of Surgery, McGill University, 1650 Cedar Avenue, Montreal, QC H3G 1A4, Canada"},{"name":"Jo Miller Orthopaedic Research Laboratory, Montreal General Hospital, Montreal, QC H3G 1A4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-9477-7989","authenticated-orcid":false,"given":"Patrik","family":"Abdelnour","sequence":"additional","affiliation":[{"name":"Surgical and Interventional Sciences, Department of Surgery, McGill University, Montreal, QC H3G 1A4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"}]},{"given":"Shawn","family":"Robbins","sequence":"additional","affiliation":[{"name":"School of Physical and Occupational Therapy, Faculty of Medicine and Health Sciences, McGill University, Montreal, QC H3G 1Y5, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karen","family":"Smith","sequence":"additional","affiliation":[{"name":"Division of Orthopaedic Surgery, Department of Surgery, McGill University, 1650 Cedar Avenue, Montreal, QC H3G 1A4, Canada"},{"name":"Jo Miller Orthopaedic Research Laboratory, Montreal General Hospital, Montreal, QC H3G 1A4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"data-curation","vocabulary":"credit"}]},{"given":"Tanya","family":"Capolicchio","sequence":"additional","affiliation":[{"name":"Division of Orthopaedic Surgery, Department of Surgery, McGill University, 1650 Cedar Avenue, Montreal, QC H3G 1A4, Canada"},{"name":"Jo Miller Orthopaedic Research Laboratory, Montreal General Hospital, Montreal, QC H3G 1A4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"data-curation","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"}]},{"given":"Maria Do Carmo","family":"Correia De Lima","sequence":"additional","affiliation":[{"name":"School of Physical and Occupational Therapy, Faculty of Medicine and Health Sciences, McGill University, Montreal, QC H3G 1Y5, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8986-6326","authenticated-orcid":false,"given":"Michael","family":"Tanzer","sequence":"additional","affiliation":[{"name":"Surgical and Interventional Sciences, Department of Surgery, McGill University, Montreal, QC H3G 1A4, Canada"},{"name":"Division of Orthopaedic Surgery, Department of Surgery, McGill University, 1650 Cedar Avenue, Montreal, QC H3G 1A4, Canada"},{"name":"Jo Miller Orthopaedic Research Laboratory, Montreal General Hospital, Montreal, QC H3G 1A4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Hulleck, A.A., Menoth Mohan, D., Abdallah, N., El Rich, M., and Khalaf, K. (2022). Present and future of gait assessment in clinical practice: Towards the application of novel trends and technologies. Front. Med. Technol., 4.","DOI":"10.3389\/fmedt.2022.901331"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1016\/j.jbiomech.2004.02.047","article-title":"Quantification of human motion: Gait analysis\u2014Benefits and limitations to its application to clinical problems","volume":"37","author":"Simon","year":"2004","journal-title":"J. Biomech."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/1743-0003-3-4","article-title":"Gait analysis methods in rehabilitation","volume":"3","author":"Baker","year":"2006","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1038\/sj.sc.3101524","article-title":"The Case for gait analysis as part of the management of incomplete spinal cord injury","volume":"41","author":"Patrick","year":"2003","journal-title":"Spinal Cord."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/j.mporth.2024.10.003","article-title":"Understanding gait assessment and analysis","volume":"38","author":"Bhambra","year":"2024","journal-title":"Orthop. Trauma"},{"key":"ref_6","first-page":"e55714","article-title":"Using Gold-standard Gait Analysis Methods to Assess Experience Effects on Lower-limb Mechanics During Moderate High-heeled Jogging and Running","volume":"127","author":"Zhang","year":"2017","journal-title":"J. Vis. Exp."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.2106\/JBJS.RVW.17.00133","article-title":"Postoperative Gait Mechanics After Total Hip Arthroplasty: A Systematic Review and Meta-Analysis","volume":"6","author":"Moyer","year":"2018","journal-title":"JBJS Rev."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"S90","DOI":"10.1016\/j.injury.2019.11.011","article-title":"Gait analysis\u2014Available platforms for outcome assessment","volume":"51","author":"Brand","year":"2020","journal-title":"Injury"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"872","DOI":"10.5535\/arm.2018.42.6.872","article-title":"Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems","volume":"42","author":"Cho","year":"2018","journal-title":"Ann. Rehabil. Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.physio.2013.03.001","article-title":"Affordable clinical gait analysis: An assessment of the marker tracking accuracy of a new low-cost optical 3D motion analysis system","volume":"99","author":"Carse","year":"2013","journal-title":"Physiotherapy"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"125","DOI":"10.2522\/ptj.20080234","article-title":"Use of Standardized Outcome Measures in Physical Therapist Practice: Perceptions and Applications","volume":"89","author":"Jette","year":"2009","journal-title":"Phys. Ther."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.2522\/ptj.20070040","article-title":"Practitioner and Organizational Barriers to Evidence-based Practice of Physical Therapists for People With Stroke","volume":"87","author":"Salbach","year":"2007","journal-title":"Phys. Ther."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1186\/s12984-019-0568-y","article-title":"Gait analysis with the Kinect v2: Normative study with healthy individuals and comprehensive study of its sensitivity, validity, and reliability in individuals with stroke","volume":"16","author":"Latorre","year":"2019","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/s11517-018-1868-2","article-title":"Automated analysis of gait and modified timed up and go using the Microsoft Kinect in people with Parkinson\u2019s disease: Associations with physical outcome measures","volume":"57","author":"Tan","year":"2019","journal-title":"Med. Biol. Eng. Comput"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"255","DOI":"10.3233\/NRE-2002-17312","article-title":"The validity of the GaitRite and the Functional Ambulation Performance scoring system in the analysis of Parkinson gait","volume":"17","author":"Nelson","year":"2002","journal-title":"NeuroRehabilitation"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1097\/MRR.0000000000000276","article-title":"Smartphone technology: A reliable and valid measure of knee movement in knee replacement","volume":"41","author":"Castle","year":"2018","journal-title":"Int. J. Rehabil. Res."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Z\u00fcgner, R., Tranberg, R., Timperley, J., Hodgins, D., Mohaddes, M., and K\u00e4rrholm, J. (2019). Validation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty. BMC Musculoskelet. Disord., 20.","DOI":"10.1186\/s12891-019-2416-4"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Onitsuka, K., Kubota, K., Yokoyama, M., Miyazawa, T., Hamaguchi, T., Taniguchi, H., Usuki, N., Miyamoto, S., Okazaki, K., and Murata, K. (2023). Clinical utility of markerless motion capture for kinematic evaluation of sit-to-stand during 30 s-CST at one year post total knee arthroplasty: A retrospective study. BMC Musculoskelet. Disord., 24.","DOI":"10.1186\/s12891-023-06364-3"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Yoshimoto, K., and Shinya, M. (2022). Use of the Azure Kinect to measure foot clearance during obstacle crossing: A validation study. PLoS ONE, 17.","DOI":"10.1371\/journal.pone.0265215"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Jo, S., Song, S., Kim, J., and Song, C. (2022). Agreement between Azure Kinect and marker-based motion analysis during functional movements: A feasibility study. Sensors, 22.","DOI":"10.3390\/s22249819"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"106324","DOI":"10.1016\/j.cmpb.2021.106324","article-title":"Postural control assessment via Microsoft Azure Kinect DK: An evaluation study","volume":"209","author":"Antico","year":"2021","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Bertram, J., Kr\u00fcger, T., R\u00f6hling, H.M., Jelusic, A., Mansow-Model, S., Schniepp, R., Wuehr, M., and Otte, K. (2023). Accuracy and repeatability of the Microsoft Azure Kinect for clinical measurement of motor function. PLoS ONE, 18.","DOI":"10.1371\/journal.pone.0279697"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/j.gaitpost.2009.04.004","article-title":"A six degrees-of-freedom marker set for gait analysis: Repeatability and comparison with a modified Helen Hayes set","volume":"30","author":"Collins","year":"2009","journal-title":"Gait Posture"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Otte, K., Kayser, B., Mansow-Model, S., Verrel, J., Paul, F., Brandt, A.U., and Schmitz-H\u00fcbsch, T. (2016). Accuracy and Reliability of the Kinect Version 2 for Clinical Measurement of Motor Function. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0166532"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.joca.2019.02.798","article-title":"A comparison of muscle activation and knee mechanics during gait between patients with non-traumatic and post-traumatic knee osteoarthritis","volume":"27","author":"Robbins","year":"2019","journal-title":"Osteoarthr. Cartil."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.jbiomech.2004.03.009","article-title":"A new method for estimating joint parameters from motion data","volume":"38","author":"Schwartz","year":"2005","journal-title":"J. Biomech."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1115\/1.3138397","article-title":"A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee","volume":"105","author":"Grood","year":"1983","journal-title":"J. Biomech. Eng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.gaitpost.2014.08.014","article-title":"Altered gait biomechanics and increased knee-specific impairments in patients with coexisting tibiofemoral and patellofemoral osteoarthritis","volume":"41","author":"Farrokhi","year":"2015","journal-title":"Gait Posture"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Molina-Rueda, F., Fern\u00e1ndez-V\u00e1zquez, D., Navarro-L\u00f3pez, V., Miangolarra-Page, J.C., and Carratal\u00e1-Tejada, M. (2022). The Timing of Kinematic and Kinetic Parameters during Gait Cycle as a Marker of Early Gait Deterioration in Multiple Sclerosis Subjects with Mild Disability. J. Clin. Med., 11.","DOI":"10.3390\/jcm11071892"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"e13752","DOI":"10.7717\/peerj.13752","article-title":"Comparison of sagittal plane gait characteristics between the overground and treadmill approach for gait analysis in typically developing children","volume":"10","author":"Senden","year":"2022","journal-title":"PeerJ"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"100045","DOI":"10.1016\/j.gloepi.2020.100045","article-title":"Bland-Altman methods for comparing methods of measurement and response to criticisms","volume":"3","author":"Mansournia","year":"2021","journal-title":"Glob. Epidemiol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1177\/1941738117726323","article-title":"Development and Validation of a Portable and Inexpensive Tool to Measure the Drop Vertical Jump Using the Microsoft Kinect V2","volume":"9","author":"Gray","year":"2017","journal-title":"Sports Health"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Albert, J.A., Owolabi, V., Gebel, A., Brahms, C.M., Granacher, U., and Arnrich, B. (2020). Evaluation of the Pose Tracking Performance of the Azure Kinect and Kinect v2 for Gait Analysis in Comparison with a Gold Standard: A Pilot Study. Sensors, 20.","DOI":"10.3390\/s20185104"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1002\/rob.22313","article-title":"Robotics-driven gait analysis: Assessing Azure Kinect\u2019s performance in in-lab versus in-corridor environments","volume":"41","author":"Guffanti","year":"2024","journal-title":"J. Field Robot."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1007\/s43465-020-00101-x","article-title":"Kinematic Gait Analysis After Primary Total Hip Replacement: A Systematic Review: Gait After Total Hip Replacement: A Systematic Review","volume":"54","author":"Mendiolagoitia","year":"2020","journal-title":"Indian J. Orthop."},{"key":"ref_37","first-page":"586412","article-title":"Center of Mass Compensation during Gait in Hip Arthroplasty Patients: Comparison between Large Diameter Head Total Hip Arthroplasty and Hip Resurfacing","volume":"2011","author":"Bouffard","year":"2011","journal-title":"Rehabil. Res. Pract."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Scataglini, S., Abts, E., Van Bocxlaer, C., Van den Bussche, M., Meletani, S., and Truijen, S. (2024). Accuracy, Validity, and Reliability of Markerless Camera-Based 3D Motion Capture Systems versus Marker-Based 3D Motion Capture Systems in Gait Analysis: A Systematic Review and Meta-Analysis. Sensors, 24.","DOI":"10.3390\/s24113686"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.gaitpost.2021.04.005","article-title":"Effects of camera viewing angles on tracking kinematic gait patterns using Azure Kinect, Kinect v2 and Orbbec Astra Pro v2","volume":"87","author":"Yeung","year":"2021","journal-title":"Gait Posture"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.gaitpost.2022.05.021","article-title":"Comparison of Azure Kinect overground gait spatiotemporal parameters to marker based optical motion capture","volume":"96","author":"Guess","year":"2022","journal-title":"Gait Posture"},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Ferraris, C., Amprimo, G., Cerfoglio, S., Masi, G., Vismara, L., and Cimolin, V. (2024). Machine-Learning-Based Validation of Microsoft Azure Kinect in Measuring Gait Profiles. Electronics, 13.","DOI":"10.3390\/electronics13234739"},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Cerfoglio, S., Ferraris, C., Vismara, L., Amprimo, G., Priano, L., Bigoni, M., Galli, M., Mauro, A., and Cimolin, V. (2024). Estimation of gait parameters in healthy and hemiplegic individuals using Azure Kinect: A comparative study with the optoelectronic system. Front. Bioeng. Biotechnol., 12.","DOI":"10.3389\/fbioe.2024.1449680"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/19\/6204\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T11:04:46Z","timestamp":1790766286000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/19\/6204"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":42,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["s26196204"],"URL":"https:\/\/doi.org\/10.3390\/s26196204","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,30]]}}}