{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T09:47:07Z","timestamp":1791884827335,"version":"4.3.4"},"reference-count":60,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Grid-following photovoltaic (PV) inverters inject fault currents whose magnitude and phase are set by the control mode active during the disturbance, so directional overcurrent relay (DOCR) settings coordinated for one inverter response can miscoordinate after a mode change. This paper proposes a communication-free adaptive protection scheme built on local sensing. A voltage-adaptive current fingerprinting classifier uses local positive sequence measurements to detect current-limiting (CL), active current priority (ACP) and reactive current priority (RCP) operation, as well as momentary cessation (MC) and asymmetrical faults. The classifier activates the relay setting group prepared offline for the detected mode. With pickup currents fixed, the coordination sub-problem is shown to be a linear program (LP), so every setting group is computed at its exact global optimum. Where the grid code droop law makes ACP and RCP indistinguishable by angle, the classifier declares the ambiguity and activates a group that is feasible for both. Under a class-0.5 instrument transformer noise model, the group placed in service is coordination-valid in 99.8% of cases and the expected residual miscoordination is 3.0\u00d710\u22125 s, 0.01% of the 0.30 s margin. On the CIGRE medium-voltage benchmark, the scheme satisfies the margin in all operating modes for three-phase, line-to-line (LL) and single-line-to-ground (SLG) faults. The same fault types are then verified at three fault locations on a practical Egyptian 11 kV feeder model, where the sensing layer is confirmed on an electromagnetic transient (EMT) model and the scheme removes the violations of single-setting coordination using an estimated 4 kB of relay memory.<\/jats:p>","DOI":"10.3390\/s26196323","type":"journal-article","created":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T10:13:02Z","timestamp":1791367982000},"page":"6323","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A New Current Fingerprinting Sensing Method for Adaptive Protection of PV-Integrated Distribution Networks"],"prefix":"10.3390","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5488-8744","authenticated-orcid":false,"given":"Ahmed A.","family":"Salem","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, Faculty of Engineering, Suez Canal University, Ismailia 41522, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"supervision","vocabulary":"credit"},{"role":"conceptualization","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-7483-5761","authenticated-orcid":false,"given":"Emad Eldeen","family":"Omran","sequence":"additional","affiliation":[{"name":"Suez Canal Authority, Ismailia 41522, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"software","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"given":"Azza A.","family":"ElDesouky","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Faculty of Engineering, Port Said University, Port Fouad 42526, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8729-8329","authenticated-orcid":false,"given":"Hany S. E.","family":"Mansour","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Faculty of Engineering, Suez Canal University, Ismailia 41522, Egypt"},{"name":"Green Energy Program, Egypt-Japan KOSEN (EJ-KOSEN) Institute of Technology, 10th of Ramadan City 44629, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1124-4487","authenticated-orcid":false,"given":"Mohamed A. A.","family":"Mohamed","sequence":"additional","affiliation":[{"name":"WMG (Warwick Manufacturing Group), University of Warwick, Coventry CV4 7AL, UK"},{"name":"Faculty of Engineering, Assiut University, Assiut 71515, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3024-5108","authenticated-orcid":false,"given":"Eyad S.","family":"Oda","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Faculty of Engineering, Suez Canal University, Ismailia 41522, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"}]}],"member":"1968","published-online":{"date-parts":[[2026,10,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1859","DOI":"10.1109\/TPEL.2009.2017082","article-title":"A review of the state of the art of power electronics for wind turbines","volume":"24","author":"Chen","year":"2009","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4030","DOI":"10.1016\/j.rser.2011.07.033","article-title":"Recent developments in microgrids and example cases around the world, A review","volume":"15","author":"Ustun","year":"2011","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"113721","DOI":"10.1016\/j.epsr.2026.113721","article-title":"Advanced adaptive overcurrent protection scheme for smart distribution networks based on short-term load forecasting","volume":"263","author":"Alasali","year":"2027","journal-title":"Electr. Power Syst. Res."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Mansour, N.M., Oda, E.S., Omran, E.E., and Abdelsalam, A.A. (2021). An analytical investigation review of DG impacts on the relaying performance in distribution networks. Proceedings of the 2021 22nd International Middle East Power Systems Conference (MEPCON), Assiut, Egypt, 14\u201316 December 2021, IEEE.","DOI":"10.1109\/MEPCON50283.2021.9686305"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1049\/iet-gtd.2018.5021","article-title":"A novel constraint and non-standard characteristics for optimal over-current relays coordination to enhance microgrid protection scheme","volume":"13","author":"Saad","year":"2019","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.tej.2019.05.016","article-title":"Impact of inverter-based DERs integration on protection, control, operation, and planning of electrical distribution grids","volume":"32","author":"Yazdaninejadi","year":"2019","journal-title":"Electr. J."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1109\/TPWRS.2004.825981","article-title":"Definition and classification of power system stability","volume":"19","author":"Kundur","year":"2004","journal-title":"IEEE Trans. Power Syst."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1109\/TPWRS.2015.2433932","article-title":"A fundamental study of applying wind turbines for power system frequency control","volume":"31","author":"Chow","year":"2016","journal-title":"IEEE Trans. Power Syst."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"111025","DOI":"10.1016\/j.epsr.2024.111025","article-title":"Highly sensitive protection scheme considering the PV operation control models","volume":"237","author":"Alasali","year":"2024","journal-title":"Electr. Power Syst. Res."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"109609","DOI":"10.1016\/j.epsr.2023.109609","article-title":"Modeling and studying the impact of dynamic reactive current limiting in grid-following inverters for distribution network protection","volume":"224","author":"Gonzalez","year":"2023","journal-title":"Electr. Power Syst. Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"100683","DOI":"10.1016\/j.ref.2025.100683","article-title":"Advanced control strategies for grid-following inverter fault response: Implementation and analysis in MATLAB for protection studies in medium voltage distribution networks","volume":"53","author":"Pham","year":"2025","journal-title":"Renew. Energy Focus"},{"key":"ref_12","unstructured":"(2018). Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces (Standard No. IEEE Std 1547-2018)."},{"key":"ref_13","unstructured":"(2022). Standard for Interconnection and Interoperability of Inverter-Based Resources Interconnecting with Associated Transmission Electric Power Systems (Standard No. IEEE Std 2800-2022)."},{"key":"ref_14","unstructured":"(2018). Technical Requirements for the Connection and Operation of Customer Installations to the Medium-Voltage Network (Standard No. VDE-AR-N 4110)."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"111594","DOI":"10.1016\/j.epsr.2025.111594","article-title":"An adaptive protection scheme for an inverter-dominated grid considering momentary cessation","volume":"244","author":"Omran","year":"2025","journal-title":"Electr. Power Syst. Res."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Kim, J., Liu, Y., Ross, B.A., Chen, Y., Samaan, N.A., Muljadi, E., and Seo, S. (2024). Fault contribution of grid-following and grid-forming inverters considering generic inverter controls and ride-through requirements. Proceedings of the IECON 2024\u201450th Annual Conference of the IEEE Industrial Electronics Society, Chicago, IL, USA, 3\u20136 November 2024, IEEE.","DOI":"10.1109\/IECON55916.2024.10905413"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1109\/TPWRD.2010.2080289","article-title":"Optimum coordination of directional overcurrent relays using the hybrid GA-NLP approach","volume":"26","author":"Bedekar","year":"2011","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/j.epsr.2016.09.017","article-title":"Setting directional overcurrent protection parameters using hybrid GA optimizer","volume":"143","author":"Bottura","year":"2017","journal-title":"Electr. Power Syst. Res."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"78503","DOI":"10.1109\/ACCESS.2019.2922426","article-title":"Improved firefly algorithm for the optimal coordination of directional overcurrent relays","volume":"7","author":"Khurshaid","year":"2019","journal-title":"IEEE Access"},{"key":"ref_20","first-page":"1910","article-title":"Optimal coordination of directional overcurrent relays using biogeography-based optimization algorithms","volume":"9","author":"Albasri","year":"2015","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.advengsoft.2013.12.007","article-title":"Grey wolf optimizer","volume":"69","author":"Mirjalili","year":"2014","journal-title":"Adv. Eng. Softw."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Alarafi, M.A., Alsheibi, A., and Alhaffar, A. (2026). Optimal coordination of directional overcurrent relays in IEC microgrid using metaheuristic algorithms. Proceedings of the 2026 IEEE 5th International Maghreb Meeting of the Conference on Sciences and Techniques of Automatic Control and Computer Engineering (MI-STA), IEEE.","DOI":"10.1109\/MI-STA68962.2026.11511195"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1016\/j.engappai.2010.01.024","article-title":"Optimal coordination of over-current relays using modified differential evolution algorithms","volume":"23","author":"Thangaraj","year":"2010","journal-title":"Eng. Appl. Artif. Intell."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Khan, B.M., Wadood, A., Khan, S., Ali, H., Khurshaid, T., Iqbal, A., and Kim, K.C. (2024). Analysis of war optimization algorithm in a multi-loop power system based on directional overcurrent relays. Energies, 17.","DOI":"10.3390\/en17225542"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1345","DOI":"10.1007\/s11227-025-07840-4","article-title":"An improved walrus optimizer for optimal coordination of directional overcurrent relays in complex networks","volume":"81","author":"Ayvaz","year":"2025","journal-title":"J. Supercomput."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"7103","DOI":"10.1007\/s00202-024-02416-6","article-title":"Optimizing directional overcurrent relay coordination with jellyfish search algorithm","volume":"106","author":"Mohamedshareef","year":"2024","journal-title":"Electr. Eng."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"109446","DOI":"10.1016\/j.epsr.2023.109446","article-title":"Optimal coordination of directional overcurrent relays in complex networks using the Elite marine predators algorithm","volume":"221","author":"Merabet","year":"2023","journal-title":"Electr. Power Syst. Res."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"119166","DOI":"10.1109\/ACCESS.2026.3719866","article-title":"A new adaptive protection framework for enhanced coordination of overcurrent and ground fault relays with non-standard curves and dynamic group settings","volume":"14","author":"Oda","year":"2026","journal-title":"IEEE Access"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1109\/TSG.2011.2149550","article-title":"A simple adaptive overcurrent protection of distribution systems with distributed generation","volume":"2","author":"Mahat","year":"2011","journal-title":"IEEE Trans. Smart Grid"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2256","DOI":"10.1109\/TPWRD.2021.3108760","article-title":"Optimal protection coordination for inverter-dominated islanded microgrids considering N-1 contingency","volume":"37","author":"Sati","year":"2022","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1332","DOI":"10.1109\/JPROC.2017.2669342","article-title":"Microgrid protection","volume":"105","author":"Hooshyar","year":"2017","journal-title":"Proc. IEEE"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"131681","DOI":"10.1109\/ACCESS.2024.3456158","article-title":"Optimum coordination approach for directional overcurrent relays in interconnected power systems considering uncertainty in photovoltaic generation","volume":"12","author":"Elsadd","year":"2024","journal-title":"IEEE Access"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"183038","DOI":"10.1109\/ACCESS.2024.3510415","article-title":"A novel solution for overcoming conflicts between line protection and LVRT in MV solar PV interconnections","volume":"12","author":"Eluvathingal","year":"2024","journal-title":"IEEE Access"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Kabeel, M.A., Eladany, M.M., and ElDesouky, A.A. (2022). A centralized protection scheme for microgrids with artificial neural network-based on fault detection and location. Proceedings of the 23rd International Middle East Power Systems Conference (MEPCON), Cairo, Egypt, 13\u201315 December 2022, IEEE.","DOI":"10.1109\/MEPCON55441.2022.10021790"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"125797","DOI":"10.1016\/j.apenergy.2025.125797","article-title":"End-to-end microgrid protection using distributed data-driven methods","volume":"391","author":"Chen","year":"2025","journal-title":"Appl. Energy"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"111017","DOI":"10.1016\/j.epsr.2024.111017","article-title":"A new and effective directional overcurrent relay coordination approach for IIDG-based distribution networks using different setting groups for peak and off-peak demand periods","volume":"237","author":"Ayvaz","year":"2024","journal-title":"Electr. Power Syst. Res."},{"key":"ref_37","first-page":"2492","article-title":"Modified inverter control for enhanced relaying coordination","volume":"31","author":"Salem","year":"2016","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_38","first-page":"2717","article-title":"Performance evaluation of advanced metaheuristic algorithms for directional overcurrent relay coordination in distribution networks","volume":"16","year":"2026","journal-title":"Sci. Rep."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1952","DOI":"10.1109\/ACCESS.2023.3347393","article-title":"Optimization techniques for directional overcurrent relay coordination: A comprehensive review","volume":"12","author":"Foqha","year":"2024","journal-title":"IEEE Access"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1002\/ese3.70362","article-title":"Advanced clustering and optimisation techniques for adaptive protection in AC microgrids with hardware-in-the-loop testing","volume":"14","author":"Alasali","year":"2026","journal-title":"Energy Sci. Eng."},{"key":"ref_41","unstructured":"Schweitzer Engineering Laboratories (2013). SEL-751 Feeder Protection Relay Data Sheet, SEL. Available online: https:\/\/selinc.com\/api\/download\/10734\/."},{"key":"ref_42","unstructured":"ABB (2023). Relion 615 Series Technical Manual, Product Version 5.0 FP1 IEC, ABB. Available online: https:\/\/techdoc.relays.protection-control.abb\/r\/615-series-Technical-Manual\/5.0-FP1-IEC\/en-US\/615-series-Technical-Manual."},{"key":"ref_43","unstructured":"Siemens (2018). Reyrolle 7SR210 and 7SR220 Argus Overcurrent Protection Relay, Catalogue Sheet, Siemens Protection Devices Ltd.. Available online: https:\/\/assets.new.siemens.com\/siemens\/assets\/api\/uuid:a73803e0-e762-4949-b637-8d36b0f24d9a\/7sr210and7sr220arguscataloguesheet.pdf."},{"key":"ref_44","unstructured":"Wilches-Bernal, F., Byrne, R., and Eto, J. (2024). Performance Specifications for Grid-Forming Inverters, Technical Report NREL\/TP-5D00-87902."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1109\/TPWRS.2021.3107959","article-title":"Transient stability assessment and enhancement of grid-forming converters embedding current reference saturation as current limiting strategy","volume":"37","author":"Rokrok","year":"2022","journal-title":"IEEE Trans. Power Syst."},{"key":"ref_46","unstructured":"Do, M.T., Bourry, F., and Chilard, O. (2017). Sensitivity analysis of the CIGRE medium-voltage benchmark network. Proceedings of the IEEE Manchester PowerTech, Manchester, UK, 18\u201322 June 2017, IEEE."},{"key":"ref_47","unstructured":"(2016). Short-Circuit Currents in Three-Phase A.C. Systems, Part 0, Calculation of Currents (Standard No. IEC 60909-0)."},{"key":"ref_48","unstructured":"(2009). Measuring Relays and Protection Equipment, Functional Requirements for over\/Under Current Protection (Standard No. IEC 60255-151)."},{"key":"ref_49","unstructured":"(2012). Instrument Transformers, Part 2, Additional Requirements for Current Transformers (Standard No. IEC 61869-2)."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"8708","DOI":"10.1109\/TNNLS.2022.3224577","article-title":"Positive-incentive noise","volume":"35","author":"Li","year":"2024","journal-title":"IEEE Trans. Neural Netw. Learn. Syst."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Li, J., Zhang, S., Zhang, H., and Zhang, J. (2025). Hierarchical-injected noise-enhanced convolutional neural network for rolling bearing fault diagnosis under limited training samples. Struct. Health Monit., online ahead of print.","DOI":"10.1177\/14759217251383791"},{"key":"ref_52","unstructured":"(2002). Electromagnetic Compatibility (EMC)\u2014Part 2-2: Environment\u2014Compatibility Levels for Low-Frequency Conducted Disturbances and Signalling in Public Low-Voltage Power Supply Systems (Standard No. IEC 61000-2-2)."},{"key":"ref_53","unstructured":"(2018). IEEE Standard for Inverse-Time Characteristics Equations for Overcurrent Relays (Standard No. IEEE Std C37.112-2018)."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.neucom.2023.02.010","article-title":"RIME: A physics-based optimization","volume":"532","author":"Su","year":"2023","journal-title":"Neurocomputing"},{"key":"ref_55","unstructured":"Holland, J.H. (1975). Adaptation in Natural and Artificial Systems, University of Michigan Press."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1942","DOI":"10.1109\/ICNN.1995.488968","article-title":"Particle swarm optimization","volume":"4","author":"Kennedy","year":"1995","journal-title":"Proc. IEEE Int. Conf. Neural Netw. (ICNN)"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.advengsoft.2016.01.008","article-title":"The whale optimization algorithm","volume":"95","author":"Mirjalili","year":"2016","journal-title":"Adv. Eng. Softw."},{"key":"ref_58","unstructured":"(2007). IEEE Guide for the Application of Current Transformers Used for Protective Relaying Purposes (Standard No. IEEE Std C37.110-2007)."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Khalifa, L.S., Abdelaziz, A.A., and Elsadd, M.A. (2018). Enhancing recloser-fuse coordination in distribution networks with distributed generation. Proceedings of the 20th International Middle East Power Systems Conference (MEPCON), Cairo, Egypt, 18\u201320 December 2018, IEEE.","DOI":"10.1109\/MEPCON.2018.8635116"},{"key":"ref_60","unstructured":"(2011). Communication Networks and Systems for Power Utility Automation, Part 8-1, Specific Communication Service Mapping (SCSM), Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO\/IEC 8802-3 (Standard No. IEC 61850-8-1)."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/19\/6323\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T09:04:45Z","timestamp":1791882285000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/26\/19\/6323"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,7]]},"references-count":60,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["s26196323"],"URL":"https:\/\/doi.org\/10.3390\/s26196323","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,7]]}}}