{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T09:03:34Z","timestamp":1775293414999,"version":"3.50.1"},"reference-count":29,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2008,3,17]],"date-time":"2008-03-17T00:00:00Z","timestamp":1205712000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A gas diffusion sequential injection system with amperometric detection using aboron-doped diamond electrode was developed for the determination of sulfite. A gasdiffusion unit (GDU) was used to prevent interference from sample matrices for theelectrochemical measurement. The sample was mixed with an acid solution to generategaseous sulfur dioxide prior to its passage through the donor channel of the GDU. Thesulfur dioxide diffused through the PTFE hydrophobic membrane into a carrier solution of 0.1 M phosphate buffer (pH 8)\/0.1% sodium dodecyl sulfate in the acceptor channel of theGDU and turned to sulfite. Then the sulfite was carried to the electrochemical flow cell anddetected directly by amperometry using the boron-doped diamond electrode at 0.95 V(versus Ag\/AgCl). Sodium dodecyl sulfate was added to the carrier solution to preventelectrode fouling. This method was applicable in the concentration range of 0.2-20 mgSO32\u2212\/L and a detection limit (S\/N = 3) of 0.05 mg SO32\u2212\/L was achieved. This method wassuccessfully applied to the determination of sulfite in wines and the analytical resultsagreed well with those obtained by iodimetric titration. The relative standard deviations forthe analysis of sulfite in wines were in the range of 1.0-4.1 %. The sampling frequency was65 h\u22121.<\/jats:p>","DOI":"10.3390\/s8031846","type":"journal-article","created":{"date-parts":[[2008,12,1]],"date-time":"2008-12-01T09:42:49Z","timestamp":1228124569000},"page":"1846-1857","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":43,"title":["Amperometric Determination of Sulfite by Gas Diffusion- Sequential Injection with Boron-Doped Diamond Electrode"],"prefix":"10.3390","volume":"8","author":[{"given":"Chakorn","family":"Chinvongamorn","sequence":"first","affiliation":[{"name":"Materials Chemistry and Catalysis Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kulwadee","family":"Pinwattana","sequence":"additional","affiliation":[{"name":"Materials Chemistry and Catalysis Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Narong","family":"Praphairaksit","sequence":"additional","affiliation":[{"name":"Materials Chemistry and Catalysis Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshihiko","family":"Imato","sequence":"additional","affiliation":[{"name":"Department of Applied Chemistry, Faculty of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Orawon","family":"Chailapakul","sequence":"additional","affiliation":[{"name":"Materials Chemistry and Catalysis Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2008,3,17]]},"reference":[{"key":"ref_1","unstructured":"Iland, P., Ewart, A., and Sitters, J. (1993). Techniques for Chemical Analysis and Stability Tests of Grape Juice and Wine, Patrick Iland Wine Promotions."},{"key":"ref_2","unstructured":"Official Method 990.28 (2000). Official Methods of Analysis of AOAC International, AOAC International. Chapter 47."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.foodcont.2005.07.008","article-title":"Simple methods for rapid determination of sulfite in food products","volume":"17","author":"Li","year":"2006","journal-title":"Food Control"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0003-2670(02)00005-3","article-title":"Novel spectrofluorimetric method for the determination of sulfite with rhodamine B hydrazide in a micellar medium","volume":"456","author":"Yang","year":"2002","journal-title":"Anal. Chim. Acta"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1016\/S0039-9140(98)00277-X","article-title":"Chemiluminescence determination of sulfite in sugar and sulfur dioxide in air using Tris(2,2\u2032-bipyridyl)ruthenium(II)-permanganate system","volume":"48","author":"Meng","year":"1999","journal-title":"Talanta"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.aca.2003.08.014","article-title":"Voltammetric and amperometric determination of sulfite using an aluminum electrode modified by nickel pentacyanonitrosylferrate film: Application to the analysis of some real samples","volume":"497","author":"Hydarpour","year":"2003","journal-title":"Anal. Chim. Acta"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1016\/j.snb.2004.09.033","article-title":"Electrochemical sensor for sulfite determination based on iron hexacyanoferrate film modified electrodes","volume":"106","author":"Garcia","year":"2005","journal-title":"Sens. Actuat. B"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/S0308-8146(98)00021-1","article-title":"Determination of free, bound and total sulphites in foods by indirect photometry-HPLC","volume":"63","author":"Pizzoferrato","year":"1998","journal-title":"Food Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/S0021-9673(01)01295-X","article-title":"Capillary electrophoretic determination of sulfite using the zone-passing technique of in-capillary derivatization","volume":"934","author":"Jankovskiene","year":"2001","journal-title":"J. Chromatogr. A"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/0003-2670(96)00261-9","article-title":"Electroimmobilisation of sulphite oxidase into a polypyrrole film and its utilisation for flow amperometric detection of sulphite","volume":"332","author":"Adeloju","year":"1996","journal-title":"Anal. Chim. Acta"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.1039\/a803618g","article-title":"Determination of sulfite in sugar and sulfur dioxide in air by chemiluminescence using the Ru(bipy)3(2+)-KBrO3 system","volume":"123","author":"Wu","year":"1998","journal-title":"Analyst"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0925-4005(02)00015-1","article-title":"Flow-injection chemiluminescence detecting sulfite with in situ electrogenerated Mn3+ as the oxidant","volume":"84","author":"Zheng","year":"2002","journal-title":"Sens. Actuat. B"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/S0003-2670(00)01197-1","article-title":"A gas diffusion sequential injection system for the determination of sulphur dioxide in wines","volume":"427","author":"Segundo","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/S0003-2670(01)01364-2","article-title":"Spectrophotometric determination of sulphur dioxide and hydrogen sulphide in gas phase by sequential injection analysis technique","volume":"449","author":"Kass","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/0003-2670(95)00611-7","article-title":"Flow-injection analysis with chemiluminescent detection of sulphite using Na2CO3---NaHCO3-Cu2+ system","volume":"323","author":"Lin","year":"1996","journal-title":"Anal. Chim. Acta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/S0003-2670(96)00421-7","article-title":"Determination of sulphite in wines by gas-diffusion flow injection analysis utilizing spectrophotometric pH-detection","volume":"337","author":"Kraak","year":"1997","journal-title":"Anal. Chim. Acta"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/S0003-2670(00)00866-7","article-title":"Determination of sulfur dioxide and ascorbic acid in beverages using a dual channel flow injection electrochemical detection system","volume":"416","author":"Cardwell","year":"2000","journal-title":"Anal. Chim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.aca.2004.05.001","article-title":"Chemiluminescent determination of sulfite traces based on the induced oxidation of Ni(II)\/tetraglycine complex by oxygen in the presence of luminol: mechanistic considerations","volume":"517","author":"Bonifacio","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1016\/j.foodchem.2004.10.032","article-title":"Determination of sulphite and acetic acid in foods by gas permeation flow injection analysis","volume":"92","author":"Araujo","year":"2005","journal-title":"Food Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/S0003-2670(97)00427-3","article-title":"Flow injection spectrophotometric determination of sulfite using a crude extract of sweet potato root (Ipomoea batatas (L.) Lam.) as a source of polyphenol oxidase","volume":"354","year":"1997","journal-title":"Anal. Chim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1016\/S0039-9140(96)02184-4","article-title":"Flow injection analysis of sulphite by gas-phase molecular absorption UV\/VIS spectrophotometry","volume":"44","author":"Safavi","year":"1997","journal-title":"Talanta"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3187","DOI":"10.1021\/ac001049q","article-title":"Sensitive and selective flow injection analysis of hydrogen sulfite\/sulfur dioxide by fluorescence detection with and without membrane separation by gas diffusion","volume":"73","author":"Mana","year":"2001","journal-title":"Anal. Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/S0003-2670(99)00179-8","article-title":"Chemiluminescence of sulfite based on auto-oxidation sensitized by rhodamine 6G","volume":"391","author":"Huang","year":"1999","journal-title":"Anal. Chim. Acta"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/S0003-2670(00)01377-5","article-title":"Flow-injection chemiluminescence determination of sulfite using online electrogenerated silver(II) as the oxidant","volume":"432","author":"Li","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/S0003-2670(99)00060-4","article-title":"Determination of sulfur dioxide in wines by gas-diffusion flow injection analysis utilizing modified electrodes with electrostatically assembled films of tetraruthenated porphyrin","volume":"387","author":"Azevedo","year":"1999","journal-title":"Anal. Chim. Acta"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/S0925-4005(02)00319-2","article-title":"Determination of sulfite by flow injection analysis using a poly[Ni-(protoporphyrin IX)] chemically modified electrode","volume":"88","author":"Carballo","year":"2003","journal-title":"Sens. Actuat. B"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1002\/1521-4109(200206)14:11<721::AID-ELAN721>3.0.CO;2-1","article-title":"Anodic voltammetry of xanthine, theophylline, theobromine and caffeine at conductive diamond electrodes and its analytical application","volume":"14","author":"Spataru","year":"2002","journal-title":"Electroanalysis"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1021\/ac010935d","article-title":"Electrochemical detection of carbamate pesticides at conductive diamond electrodes","volume":"74","author":"Rao","year":"2002","journal-title":"Anal. Chem."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1002\/1521-4109(200106)13:10<831::AID-ELAN831>3.0.CO;2-Z","article-title":"Microwave-enhanced anodic stripping detection of lead in a river sediment sample. A mercury-free procedure employing a boron-doped diamond electrode","volume":"13","author":"Tsai","year":"2001","journal-title":"Electroanalysis"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/8\/3\/1846\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:20:33Z","timestamp":1760221233000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/8\/3\/1846"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,3,17]]},"references-count":29,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2008,3]]}},"alternative-id":["s8031846"],"URL":"https:\/\/doi.org\/10.3390\/s8031846","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,3,17]]}}}