{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:55:41Z","timestamp":1760144141017,"version":"build-2065373602"},"reference-count":41,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2024,3,26]],"date-time":"2024-03-26T00:00:00Z","timestamp":1711411200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sports"],"abstract":"<jats:p>A goal of mobile monitoring is to approximate metabolic energy expenditure (EE) during activities of daily living and exercise. Many physical activity monitors are inaccurate with respect to estimated EE and differentiating between activities that occur over short intervals. The objective of our study was to assess the validity of the SenseWear Armband (SWA) compared to indirect calorimetry (IC) during short intervals of walking and running. Twenty young, fit participants walked (preferred speed) and ran (75%, 85%, and 95% of predicted VO2max run speeds) on a treadmill. EE estimates from IC, SWA, and prediction equations that used the SWA, speed, and heart rate were examined during each 4 min interval and across the whole protocol (Total). The level of significance was p &lt; 0.05. The SWA overestimated EE relative to IC by 1.62 kcal\u00b7min\u22121 while walking and 1.05 kcal\u00b7min\u22121 while running at 75%. However, it underestimated EE at the 85% (0.05 kcal\u00b7min\u22121) and 95% (0.92 kcal\u00b7min\u22121) speeds, but not significantly, and overestimated total EE by 28.29 kcal. Except for walking, our results suggest that the SWA displayed a good level of agreement (ICC = 0.76 to 0.84) with IC measures. Activity-specific algorithms using SWA, speed, and heart rate improved EE estimates, based on the standard error of the estimates, but perhaps not enough to justify extra sensors. The SWA may enable EE estimation of locomotion outside the laboratory, including those with short bouts of high intensity activity, but continued development of the SWA, or devices like it, is needed to enable accurate monitoring.<\/jats:p>","DOI":"10.3390\/sports12040093","type":"journal-article","created":{"date-parts":[[2024,3,26]],"date-time":"2024-03-26T13:16:41Z","timestamp":1711459001000},"page":"93","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of the SenseWear Armband during Short Bouts of Exercise"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3125-0400","authenticated-orcid":false,"given":"Ryan D.","family":"Wedge","sequence":"first","affiliation":[{"name":"Department of Physical Therapy, College of Allied Health Sciences, East Carolina University, Greenville, NC 27834, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mike","family":"McCammon","sequence":"additional","affiliation":[{"name":"Department of Kinesiology, College of Health and Human Performance, East Carolina University, Greenville, NC 27834, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9963-2985","authenticated-orcid":false,"given":"Stacey A.","family":"Meardon","sequence":"additional","affiliation":[{"name":"Department of Physical Therapy, College of Allied Health Sciences, East Carolina University, Greenville, NC 27834, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,3,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e14327","DOI":"10.1111\/sms.14327","article-title":"Direct and Indirect Impact of Low Energy Availability on Sports Performance","volume":"34","author":"Melin","year":"2023","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1249\/MSS.0000000000002092","article-title":"Training Load and Energy Expenditure during Military Basic Training Period","volume":"52","author":"Jurvelin","year":"2020","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"S574","DOI":"10.1249\/MSS.0b013e31817c71e7","article-title":"New Techniques and Issues in Assessing Walking Behavior and Its Contexts","volume":"40","author":"Freedson","year":"2008","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"e13938","DOI":"10.2196\/13938","article-title":"Accuracy of 12 Wearable Devices for Estimating Physical Activity Energy Expenditure Using a Metabolic Chamber and the Doubly Labeled Water Method: Validation Study","volume":"7","author":"Murakami","year":"2019","journal-title":"JMIR MHealth UHealth"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Dasa, M.S., Friborg, O., Kristoffersen, M., Pettersen, G., Sundgot-Borgen, J., and Rosenvinge, J.H. (2022). Accuracy of Tracking Devices\u2019 Ability to Assess Exercise Energy Expenditure in Professional Female Soccer Players: Implications for Quantifying Energy Availability. Int. J. Environ. Res. Public. Health, 19.","DOI":"10.3390\/ijerph19084770"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1152\/japplphysiol.00714.2018","article-title":"Evaluating Physiological Signal Salience for Estimating Metabolic Energy Cost from Wearable Sensors","volume":"126","author":"Ingraham","year":"2019","journal-title":"J. Appl. Physiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1804","DOI":"10.1152\/japplphysiol.00309.2011","article-title":"Evaluation of Artificial Neural Network Algorithms for Predicting METs and Activity Type from Accelerometer Data: Validation on an Independent Sample","volume":"111","author":"Freedson","year":"2011","journal-title":"J. Appl. Physiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1682\/JRRD.2007.11.0197","article-title":"How Humans Walk: Bout Duration, Steps per Bout, and Rest Duration","volume":"45","author":"Orendurff","year":"2008","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1249\/01.MSS.0000126805.32659.43","article-title":"Evaluation of the SenseWear Pro Armband\u2122 to assess energy expenditure during exercise","volume":"36","author":"Jakicic","year":"2004","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"983","DOI":"10.3389\/fphys.2017.00983","article-title":"Monitoring Energy Expenditure Using a Multi-Sensor Device\u2014Applications and Limitations of the SenseWear Armband in Athletic Populations","volume":"8","author":"Koehler","year":"2017","journal-title":"Front. Physiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.jsams.2017.07.022","article-title":"Validity of the ActiGraph GT3X+ and BodyMedia SenseWear Armband to Estimate Energy Expenditure during Physical Activity and Sport","volume":"21","author":"Gastin","year":"2018","journal-title":"J. Sci. Med. Sport"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2806","DOI":"10.1519\/JSC.0b013e3182a1f836","article-title":"Validation of the SenseWear Pro3 Armband Using an Incremental Exercise Test","volume":"28","author":"Mortelmans","year":"2014","journal-title":"J. Strength Cond. Res."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Taylor, M. (2014). Validation of The Bodymedia Mini Armband to Estimate Energy Expenditure of Female Basketball Players during Variable Intensity Game-like Conditions. [Doctoral Dissertation, University of Pittsburgh].","DOI":"10.1249\/01.mss.0000494070.82906.d3"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1519\/JSC.0000000000000243","article-title":"Validity of the SenseWear Armband to Assess Energy Expenditure During Intermittent Exercise and Recovery in Rugby Union Players","volume":"28","author":"Zanetti","year":"2014","journal-title":"J. Strength Cond. Res."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2076","DOI":"10.1249\/mss.0b013e31814fb439","article-title":"Energy Cost of Physical Activities in Children: Validation of SenseWear Armband","volume":"39","author":"Arvidsson","year":"2007","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1007\/s00421-010-1695-0","article-title":"Validation of the SenseWear Armband at High Intensity Exercise","volume":"111","author":"Drenowatz","year":"2011","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1249\/MSS.0b013e31820750f5","article-title":"Assessing Energy Expenditure in Male Endurance Athletes: Validity of the SenseWear Armband","volume":"43","author":"Koehler","year":"2011","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1055\/s-2003-40701","article-title":"Use of Heart Rate to Predict Energy Expenditure from Low to High Activity Levels","volume":"24","author":"Hiiloskorpi","year":"2003","journal-title":"Int. J. Sports Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1152\/jappl.1963.18.2.367","article-title":"Energy Cost of Running","volume":"18","author":"Margaria","year":"1963","journal-title":"J. Appl. Physiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1097\/00005768-199703000-00019","article-title":"Non-Exercise V02max Estimation for Physically Active College Students","volume":"29","author":"George","year":"1997","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_21","unstructured":"Liguori, G. (2021). ACSM\u2019s Guidelines for Exercise Testing and Prescription (American College of Sports Medicine), Lippincott. [11th ed.]."},{"key":"ref_22","first-page":"65","article-title":"A Simple Sequentially Rejective Multiple Test Procedure","volume":"6","author":"Holm","year":"1979","journal-title":"Scand. J. Stat."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1086","DOI":"10.1037\/0003-066X.46.10.1086","article-title":"Effect Sizes: Pearson\u2019s Correlation, Its Display via the BESD, and Alternative Indices","volume":"46","author":"Rosenthal","year":"1991","journal-title":"Am. Psychol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"597","DOI":"10.22237\/jmasm\/1257035100","article-title":"New Effect Size Rules of Thumb","volume":"8","author":"Sawilowsky","year":"2009","journal-title":"J. Mod. Appl. Stat. Methods"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Jenkins, D.G., and Quintana-Ascencio, P.F. (2020). A Solution to Minimum Sample Size for Regressions. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0229345"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1830","DOI":"10.1080\/02640414.2016.1140220","article-title":"Validity of SenseWear\u00ae Armband v5.2 and v2.2 for Estimating Energy Expenditure","volume":"34","author":"Bhammar","year":"2016","journal-title":"J. Sports Sci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1249\/01.MSS.0000128144.91337.38","article-title":"Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure","volume":"36","author":"Fruin","year":"2004","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.jesf.2014.11.002","article-title":"Validity of the SenseWear Armband Step Count Measure during Controlled and Free-Living Conditions","volume":"13","author":"Lee","year":"2015","journal-title":"J. Exerc. Sci. Fit."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1136\/bjsports-2018-099643","article-title":"How Well Do Activity Monitors Estimate Energy Expenditure? A Systematic Review and Meta-Analysis of the Validity of Current Technologies","volume":"54","author":"Turicchi","year":"2020","journal-title":"Br. J. Sports Med."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1109\/JSEN.2016.2628346","article-title":"A Survey on Activity Detection and Classification Using Wearable Sensors","volume":"17","author":"Cornacchia","year":"2017","journal-title":"IEEE Sens. J."},{"key":"ref_32","first-page":"1","article-title":"Concurrent Validity of ActiGraph GT3X+ and Axivity AX3 Accelerometers for Estimating Physical Activity and Sedentary Behavior","volume":"4","author":"Hedayatrad","year":"2020","journal-title":"J. Meas. Phys. Behav."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1876","DOI":"10.1249\/MSS.0b013e3181d9cf7f","article-title":"Critical Power: Implications for Determination of VO2max and Exercise Tolerance","volume":"42","author":"Jones","year":"2010","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1249\/00003677-199600240-00004","article-title":"The Slow Component of Oxygen Uptake Kinetics in Humans","volume":"24","author":"Gaesser","year":"1996","journal-title":"Exerc. Sport Sci. Rev."},{"key":"ref_35","first-page":"247165","article-title":"SenseWear Armband and Stroke: Validity of Energy Expenditure and Step Count Measurement during Walking","volume":"2012","author":"Manns","year":"2012","journal-title":"Stroke Res. Treat."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Cabarkapa, D.V., Cabarkapa, D., Philipp, N.M., and Fry, A.C. (2023). Impact of the Anatomical Accelerometer Placement on Vertical Jump Performance Characteristics. Sports, 11.","DOI":"10.3390\/sports11040092"},{"key":"ref_37","unstructured":"Andre, D., Pelletier, R., Farringdon, J., Safier, S., Talbott, W., Stone, R., Vyas, N., Wolf, D., Vishnubhatla, S., and Boehmke, S. (2006). The Development of the SenseWear\u00ae Armband, a Revolutionary Energy Assessment Device to Assess Physical Activity and Lifestyle, Body Media, Inc."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"e110","DOI":"10.2196\/jmir.9157","article-title":"Using Fitness Trackers and Smartwatches to Measure Physical Activity in Research: Analysis of Consumer Wrist-Worn Wearables","volume":"20","author":"Henriksen","year":"2018","journal-title":"J. Med. Internet Res."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1519\/SSC.0000000000000464","article-title":"Nutritional Needs of the Female Athlete: Risk and Prevention of Low Energy Availability","volume":"42","author":"Black","year":"2020","journal-title":"Strength Cond. J."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1007\/s00167-011-1398-z","article-title":"Anterior Cruciate Ligament Reconstruction Improves the Metabolic Energy Cost of Level Walking at Customary Speeds","volume":"19","author":"Colak","year":"2011","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/S0966-6362(99)00009-0","article-title":"The Energy Expenditure of Normal and Pathologic Gait","volume":"9","author":"Waters","year":"1999","journal-title":"Gait Posture"}],"container-title":["Sports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4663\/12\/4\/93\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:18:58Z","timestamp":1760105938000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4663\/12\/4\/93"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,26]]},"references-count":41,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["sports12040093"],"URL":"https:\/\/doi.org\/10.3390\/sports12040093","relation":{},"ISSN":["2075-4663"],"issn-type":[{"type":"electronic","value":"2075-4663"}],"subject":[],"published":{"date-parts":[[2024,3,26]]}}}