{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T03:11:03Z","timestamp":1787886663602,"version":"build-2784847793"},"reference-count":37,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T00:00:00Z","timestamp":1778025600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sports"],"abstract":"<jats:p>Background: Plantar pressure analysis provides insight into load distribution at the foot\u2013pedal interface during cycling; however, its modulation by pedaling power, cadence, and overuse injury status remains poorly understood by professional cyclists. It is unclear whether common overuse injuries, such as Achilles tendinopathy, patellofemoral pathology, and iliotibial band syndrome, are associated with distinct plantar loading patterns. This study aimed to characterize plantar pressure distribution in elite cyclists and determine how power, cadence, and injury status influence this pattern. Methods: Professional cyclists completed a single integrated protocol using a high-resolution in-shoe pressure system. Plantar forces were recorded across nine anatomical regions and grouped into the transverse and longitudinal segments of the foot. Three phases were included: absolute power manipulation (100 and 200 W), cadence manipulation (80 and 100 rpm) at fixed power, and an ecological combined protocol using relative power (1.5 and 3 W\u00b7kg\u22121) with individualized cadence. The cyclists used their habitual bike setups. Participants were classified into the non-pathological (NP), AT, PFP, or ITBS groups. Mixed repeated-measures ANOVAs were used to analyze the effects of power, cadence, zone, foot, and injury status. Results: The plantar pressure distribution was consistently dominated by the medial forefoot. Increasing the absolute power from 100 to 200 W increased the maximal plantar pressures by 84.74% (p &lt; 0.001), whereas increasing the cadence from 80 to 100 rpm at a fixed power increased the pressures by 15.90% (p = 0.003). Under individualized conditions, increasing relative power from 1.5 to 3 W\u00b7kg\u22121 increased pressures by 39.59% (p &lt; 0.001), whereas cadence had no global main effect but significantly altered the regional pressure distribution (p &lt; 0.001). Injury groups showed pathology-specific deviations, including higher overall pressures and asymmetry in Achilles tendinopathy, bilateral asymmetry in patellofemoral pathology, and asymmetric loading patterns in iliotibial band syndrome. Conclusions: Power is the main determinant of plantar pressure, and cadence modulates load distribution. Overuse injuries induce pathology-specific pressure patterns, supporting plantar pressure analysis for injury prevention and performance optimization in athletes.<\/jats:p>","DOI":"10.3390\/sports14050184","type":"journal-article","created":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T08:01:39Z","timestamp":1778140899000},"page":"184","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Effect of Power Output and Pedaling Cadence on Plantar Pressures in Professional Cyclists with Overuse Injuries"],"prefix":"10.3390","volume":"14","author":[{"given":"D\u00eddac","family":"Navarro-Mart\u00ednez","sequence":"first","affiliation":[{"name":"Department of Physical Preparation and Conditioning, Faculty of Physical Activity and Sport Sciences, Catholic University of Valencia, 46900 Torrent, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javier","family":"Zahonero","sequence":"additional","affiliation":[{"name":"Department of Physical Preparation and Conditioning, Faculty of Physical Activity and Sport Sciences, Catholic University of Valencia, 46900 Torrent, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8564-9655","authenticated-orcid":false,"given":"Pablo","family":"Vera","sequence":"additional","affiliation":[{"name":"Institute for Research on Musculoskeletal Disorders, School of Medicine and Health Sciences, Catholic University of Valencia, 46001 Valencia, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-9747-9645","authenticated-orcid":false,"given":"Jos\u00e9","family":"Mart\u00ed-Mart\u00ed","sequence":"additional","affiliation":[{"name":"Department of Physical Preparation and Conditioning, Faculty of Physical Activity and Sport Sciences, Catholic University of Valencia, 46900 Torrent, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1518-8582","authenticated-orcid":false,"given":"Florentino","family":"Huertas","sequence":"additional","affiliation":[{"name":"Department of Physical Preparation and Conditioning, Faculty of Physical Activity and Sport Sciences, Catholic University of Valencia, 46900 Torrent, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6657-7246","authenticated-orcid":false,"given":"Carlos","family":"Barrios","sequence":"additional","affiliation":[{"name":"Institute for Research on Musculoskeletal Disorders, School of Medicine and Health Sciences, Catholic University of Valencia, 46001 Valencia, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,5,6]]},"reference":[{"key":"ref_1","unstructured":"Burke, E.E.R. (2003). Cycling Biomechanics: Road and Mountain Bike, Human Kinetics. High-Tech Cycling (2.a ed.)."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.jelekin.2007.10.010","article-title":"Electromyographic analysis of pedaling: A review","volume":"19","author":"Hug","year":"2009","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1080\/14763141.2012.731428","article-title":"Effects of workload and pedalling cadence on knee forces in competitive cyclists","volume":"12","author":"Bini","year":"2013","journal-title":"Sports Biomech.\/Int. Soc. Biomech. Sports"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1123\/ijsb.6.4.394","article-title":"A dual piezoelectric element force pedal for kinetic analysis of cycling","volume":"6","author":"Broker","year":"1990","journal-title":"Int. J. Sport Biomech."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1080\/026404100365072","article-title":"The influence of cadence and power output on force application and in-shoe pressure distribution during cycling by competitive and recreational cyclists","volume":"18","author":"Sanderson","year":"2000","journal-title":"J. Sports Sci."},{"key":"ref_6","first-page":"299","article-title":"In-shoe pressure distribution for running in various types of footwear","volume":"11","author":"Hennig","year":"1995","journal-title":"J. Appl. Biomech."},{"key":"ref_7","first-page":"12","article-title":"Influence of carbon fiber foot orthoses on plantar pressure distribution in cycling","volume":"26","author":"Baur","year":"2012","journal-title":"Sportverletz. Sportschaden Organ Ges. Orthop.-Traumatol. Sportmed."},{"key":"ref_8","first-page":"85","article-title":"The muscle force component in pedaling retains constant direction across pedaling rates","volume":"25","author":"Loras","year":"2009","journal-title":"J. Appl. Biomech."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/0021-9290(93)90466-R","article-title":"In-shoe pressure distribution for cycling at different cadences","volume":"26","author":"Amoroso","year":"1993","journal-title":"J. Biomech."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"313","DOI":"10.2165\/00007256-200535040-00003","article-title":"The science of cycling: Factors affecting performance\u2014Part 2","volume":"35","author":"Faria","year":"2005","journal-title":"Sports Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1097\/00005768-200108000-00018","article-title":"Preferred pedalling cadence in professional cycling","volume":"33","author":"Hoyos","year":"2001","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/j.jelekin.2006.07.007","article-title":"Muscle activation during cycling at different cadences: Effect of maximal strength capacity","volume":"17","author":"Bieuzen","year":"2007","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1111\/j.1365-201X.2005.01490.x","article-title":"Neuromuscular function during prolonged pedalling exercise at different cadences","volume":"185","author":"Sarre","year":"2005","journal-title":"Acta Physiol. Scand."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1249\/00005768-199207000-00008","article-title":"Cycling efficiency is related to the percentage of type I muscle fibers","volume":"24","author":"Coyle","year":"1992","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1177\/107110070602700108","article-title":"The effect of triceps surae contracture force on plantar foot pressure distribution","volume":"27","author":"Aronow","year":"2006","journal-title":"Foot Ankle Int."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1177\/0309364613486916","article-title":"Patellar tendon bearing brace: Combined effect of heel clearance and ankle status on foot plantar pressure","volume":"38","author":"Alimerzaloo","year":"2014","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1080\/02701367.2008.10599511","article-title":"The influence of matching populations on kinematic and kinetic variables in runners with iliotibial band syndrome","volume":"79","author":"Grau","year":"2008","journal-title":"Res. Q. Exerc. Sport"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1080\/0264041031000071010","article-title":"The effect of prolonged cycling on pedal forces","volume":"21","author":"Sanderson","year":"2003","journal-title":"J. Sports Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1007\/s00421-005-0039-y","article-title":"Power output during women\u2019s World Cup road cycle racing","volume":"95","author":"Ebert","year":"2005","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_20","unstructured":"Jeukendrup, A.E. (2002). High-Performance Cycling, Human Kinetics."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.foot.2007.04.002","article-title":"BioFoot\u00ae in-shoe system: Normal values and assessment of the reliability and repeatability","volume":"17","author":"Cuevas","year":"2007","journal-title":"Foot"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/S0268-0033(01)00026-2","article-title":"A Comparison of vertical force and temporal parameters produced by an in-shoe pressure measuring system and a force platform","volume":"16","author":"Barnett","year":"2001","journal-title":"Clin. Biomech."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"489","DOI":"10.2165\/00007256-200131070-00004","article-title":"Tests of cycling performance","volume":"31","author":"Paton","year":"2001","journal-title":"Sports Med."},{"key":"ref_24","first-page":"276","article-title":"Validation of a mathematical model for road cycling power","volume":"14","author":"Martin","year":"1998","journal-title":"J. Appl. Biomech."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1055\/s-2004-817855","article-title":"Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter","volume":"26","author":"Bertucci","year":"2005","journal-title":"Int. J. Sports Med."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1123\/ijspp.2013-0317","article-title":"Validity and reliability of the look Keo power pedal system for measuring power output during incremental and repeated sprint cycling","volume":"10","author":"Sparks","year":"2015","journal-title":"Int. J. Sports Physiol. Perform."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1055\/s-2008-1038621","article-title":"Validity and reliability of the Ergomopro powermeter","volume":"29","author":"Kirkland","year":"2008","journal-title":"Int. J. Sports Med."},{"key":"ref_28","unstructured":"Field, A.P. (2009). Discovering Statistics Using SPSS: (and Sex, Drugs and Rock \u00abn\u00bb Roll), SAGE Publications. [3rd ed.]."},{"key":"ref_29","unstructured":"Johnsson, E.B. (1987). An Investigation of the In-Shoe Pressure Distribution During Cycling in Conventional Cycling Shoes or Running Shoes, Human Kinetics. Biomechanics X-B."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.jsams.2012.04.006","article-title":"Contoured in-shoe foot orthoses increase mid-foot plantar contact area when compared with a flat insert during cycling","volume":"16","author":"Bousie","year":"2013","journal-title":"J. Sci. Med. Sport"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/0958-2592(92)90047-S","article-title":"In-shoe plantar pressure measurement: A review","volume":"2","author":"Cavanagh","year":"1992","journal-title":"Foot"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1080\/14763141.2010.540672","article-title":"Kinetics and kinematics analysis of incremental cycling to exhaustion","volume":"9","author":"Bini","year":"2010","journal-title":"Sports Biomech."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.clinbiomech.2007.08.015","article-title":"Changes in plantar pressure distribution after Achilles tendon augmentation with flexor hallucis longus transfer","volume":"23","author":"Hahn","year":"2008","journal-title":"Clin. Biomech."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1007\/s00167-013-2726-2","article-title":"Long-term biomechanical outcomes after Achilles tendon ruptures","volume":"23","author":"Rosso","year":"2015","journal-title":"Knee Surg. Sports Traumatol. Arthrosc. Off. J. ESSKA"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Bini, E.R.R., and Carpes, F.P. (2014). Non-traumatic injuries in cycling. Biomechanics of Cycling, Springer.","DOI":"10.1007\/978-3-319-05539-8"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1115\/1.2193543","article-title":"How changing the inversion\/eversion foot angle affects the nondriving intersegmental knee moments and the relative activation of the vastii muscles in cycling","volume":"128","author":"Gregersen","year":"2006","journal-title":"J. Biomech. Eng."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1007\/s12178-010-9061-8","article-title":"Iliotibial band friction syndrome","volume":"3","author":"Lavine","year":"2010","journal-title":"Curr. Rev. Musculoskelet. Med."}],"container-title":["Sports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4663\/14\/5\/184\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T08:33:10Z","timestamp":1778142790000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4663\/14\/5\/184"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,6]]},"references-count":37,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,5]]}},"alternative-id":["sports14050184"],"URL":"https:\/\/doi.org\/10.3390\/sports14050184","relation":{},"ISSN":["2075-4663"],"issn-type":[{"value":"2075-4663","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,6]]}}}