{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T06:55:58Z","timestamp":1781506558323,"version":"3.54.1"},"reference-count":22,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T00:00:00Z","timestamp":1759190400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Institute of Health (NIH) United States","award":["RO1CA273700-01"],"award-info":[{"award-number":["RO1CA273700-01"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Tomography"],"abstract":"<jats:p>Breast cancer detection remains a significant challenge, with traditional mammography presenting barriers such as discomfort, radiation exposure, high false-positive rates, and financial burden. Moreover, younger women frequently fall outside routine mammographic screening guidelines, leaving critical gaps in early detection. Objectives: This study investigates the potential of quantitative transmission breast acoustic computed tomography scanner imaging (QT3D) as an innovative, non-invasive imaging modality for characterizing and evaluating breast masses. Methods: A comparative analysis between QT3D imaging and magnetic resonance imaging (MRI) was conducted in a cohort of patients with biopsy-proven benign or malignant breast lesions, comparing key metrics in quantifying breast masses for the purposes of breast mass characterization. Results: The findings in this study highlight its capability in identifying relatively small tumors, multiple lesions, satellite lesions, intraductal extensions, and calcifications, in addition to offering valuable diagnostic insights. Conclusions: This work is a first step toward studies essential for confirming its clinical feasibility, establishing its role in breast cancer tumor characterization, and potentially improving patient outcomes.<\/jats:p>","DOI":"10.3390\/tomography11100111","type":"journal-article","created":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T07:58:13Z","timestamp":1759305493000},"page":"111","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Quantitative Volumetric Analysis Using 3D Ultrasound Tomography for Breast Mass Characterization"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-5588-9730","authenticated-orcid":false,"given":"Maria L.","family":"Anzola","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON M4N 3M5, Canada"},{"name":"Physical Sciences, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Alberico","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON M4N 3M5, Canada"},{"name":"Physical Sciences, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joyce","family":"Yip","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON M4N 3M5, Canada"},{"name":"Physical Sciences, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Wiskin","sequence":"additional","affiliation":[{"name":"QT Imaging Holdings, Inc., Novato, CA 94949, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bilal","family":"Malik","sequence":"additional","affiliation":[{"name":"QT Imaging Holdings, Inc., Novato, CA 94949, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raluca","family":"Dinu","sequence":"additional","affiliation":[{"name":"QT Imaging Holdings, Inc., Novato, CA 94949, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3271-8087","authenticated-orcid":false,"given":"Belinda","family":"Curpen","sequence":"additional","affiliation":[{"name":"Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, ON M4N 3M5, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3099-7425","authenticated-orcid":false,"given":"Michael L.","family":"Oelze","sequence":"additional","affiliation":[{"name":"Grainer College of Engineering, University of Illinois at Urbana-Champaign, Champaign, IL 61801, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory J.","family":"Czarnota","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON M4N 3M5, Canada"},{"name":"Physical Sciences, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada"},{"name":"Department of Radiation Oncology, Sciences Centre, Physical Sciences, University of Toronto, Toronto, ON M4N 3M5, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,9,30]]},"reference":[{"key":"ref_1","unstructured":"National Cancer Institute of Canada (2024). Canadian Cancer Statistics 2024. Canadian Cancer Society, National Cancer Institute of Canada."},{"key":"ref_2","unstructured":"Canadian Cancer Statistic Dashboard (CCSD) (2025, September 01). Cancer Incidence 2024. Available online: https:\/\/cancerstats.ca\/."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1200\/JCO.1998.16.1.93","article-title":"Primary chemotherapy in operable breast cancer: Eight-year experience at the Milan Cancer Institute","volume":"16","author":"Bonadonna","year":"1998","journal-title":"J. Clin. Oncol."},{"key":"ref_4","unstructured":"Coherent Digital (2013). The Role of Taxanes in Neoadjuvant Chemotherapy for Women with Non-Metastatic Breast Cancer, Canadian Electronic Library. [2nd ed.]."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.molonc.2008.04.001","article-title":"Imaging and cancer: A review","volume":"2","author":"Fass","year":"2008","journal-title":"Mol. Oncol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.diii.2017.01.001","article-title":"BI-RADS\u00ae fifth edition: A summary of changes","volume":"98","author":"Spak","year":"2017","journal-title":"Diagn. Interv. Imaging"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1148\/radiol.10091173","article-title":"Calcifications in Digital Mammographic Screening: Improvement of Early Detection of Invasive Breast Cancers?","volume":"255","author":"Weigel","year":"2010","journal-title":"Radiology"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1186\/bcr1829","article-title":"Mammographic density, breast cancer risk and risk prediction","volume":"9","author":"Vachon","year":"2007","journal-title":"Breast Cancer Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.ajog.2014.06.048","article-title":"Screening ultrasound as an adjunct to mammography in women with mammographically dense breasts","volume":"212","author":"Scheel","year":"2015","journal-title":"Am. J. Obstet. Gynecol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/RUQ.0000000000000568","article-title":"Reproducibility of Automated Breast Ultrasonography and Handheld Ultrasonography for Breast Lesion Size Measurement","volume":"38","author":"Park","year":"2022","journal-title":"Ultrasound Q."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1148\/radiol.2019182947","article-title":"Breast MRI: State of the Art","volume":"292","author":"Mann","year":"2019","journal-title":"Radiology"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1002\/jmri.25479","article-title":"Diffusion-weighted breast MRI: Clinical applications and emerging techniques","volume":"45","author":"Partridge","year":"2017","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1007\/s12609-016-0230-7","article-title":"Breast MRI Screening: Benefits and Limitations","volume":"8","author":"Heller","year":"2016","journal-title":"Curr. Breast Cancer Rep."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1883","DOI":"10.1007\/s11255-020-02779-2","article-title":"Gadolinium-based contrast media exposure and the possible risk of subclinical kidney damage: A pilot study","volume":"53","author":"Martino","year":"2021","journal-title":"Int. Urol. Nephrol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1016\/j.acra.2018.02.014","article-title":"Automated Breast Ultrasonography (ABUS) in the Screening and Diagnostic Setting","volume":"25","author":"Rella","year":"2018","journal-title":"Acad. Radiol."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Telegrafo, M., Stucci, S.L., Gurrado, A., Catacchio, C., Cofone, F., Maruccia, M., Ianora, A.A.S., and Moschetta, M. (2024). Automated Breast Ultrasound for Evaluating Response to Neoadjuvant Therapy: A Comparison with Magnetic Resonance Imaging. J. Pers. Med., 14.","DOI":"10.3390\/jpm14090930"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"554","DOI":"10.3390\/tomography10040044","article-title":"Breast Tomographic Ultrasound: The Spectrum from Current Dense Breast Cancer Screenings to Future Theranostic Treatments","volume":"10","author":"Littrup","year":"2024","journal-title":"Tomography"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Wiskin, J., Lee, S., Cwikla, M., and Malik, B. (2020, January 15\u201320). Quantitative Breast Density (QBD) estimation with 3D transmission ultrasound and incomplete information. Proceedings of the SPIE Medical Imaging, Houston, TX, USA.","DOI":"10.1117\/12.2549837"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1158\/1940-6207.CAPR-19-0268","article-title":"Quantitative assessment of breast density: Transmission ultrasound is comparable to mammography with tomosynthesis","volume":"12","author":"Natesan","year":"2019","journal-title":"Cancer Prev. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"S10","DOI":"10.1016\/j.acra.2020.11.011","article-title":"An Exploratory Multi-reader, Multi-case Study Comparing Transmission Ultrasound to Mammography on Recall Rates and Detection Rates for Breast Cancer Lesions","volume":"29","author":"Malik","year":"2022","journal-title":"Acad. Radiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2248","DOI":"10.1016\/j.acra.2023.12.038","article-title":"A Multireader Multicase (MRMC) Receiver Operating Characteristic (ROC) Study Evaluating Noninferiority of Quantitative Transmission (QT) Ultrasound to Digital Breast Tomosynthesis (DBT) on Detection and Recall of Breast Lesions","volume":"31","author":"Jiang","year":"2024","journal-title":"Acad. Radiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"100827","DOI":"10.1016\/j.tranon.2020.100827","article-title":"Breast lesion characterization using Quantitative Ultrasound (QUS) and derivative texture methods","volume":"13","author":"Osapoetra","year":"2020","journal-title":"Transl Oncol."}],"container-title":["Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2379-139X\/11\/10\/111\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T09:15:12Z","timestamp":1760346912000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2379-139X\/11\/10\/111"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,30]]},"references-count":22,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2025,10]]}},"alternative-id":["tomography11100111"],"URL":"https:\/\/doi.org\/10.3390\/tomography11100111","relation":{},"ISSN":["2379-139X"],"issn-type":[{"value":"2379-139X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,30]]}}}