{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T05:35:06Z","timestamp":1794461706584,"version":"4.9.1"},"reference-count":59,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T00:00:00Z","timestamp":1787270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Tomography"],"abstract":"<jats:p>Background\/Objectives: Computed tomography perfusion is widely used in acute ischemic stroke, but its performance is less reliable for lacunar and infratentorial infarcts. This technical review examines the acquisition and processing factors that influence their detectability. Methods: A targeted technical review of PubMed\/MEDLINE, Scopus, and Web of Science was performed, focusing on acquisition, reconstruction, vascular input selection, deconvolution, filtering, spatial sampling, automated classification, posterior circulation stroke, and lacunar infarction. Results: Detectability depends on lesion size and contrast, posterior fossa artifacts, spatial and temporal resolution, vascular curve quality, mathematical stabilization, and automated thresholds. Larger cerebellar infarcts may remain visible, whereas brainstem, deep cerebellar, and perforator lesions are more vulnerable. Temporal maps and direct review of parametric images may reveal abnormalities absent from automated summaries. Conclusions: This technical review shows that computed tomography perfusion should be interpreted as a derived estimate rather than a direct representation of cerebral hemodynamics. Negative automated findings do not exclude lacunar or infratentorial infarction when clinical suspicion remains high.<\/jats:p>","DOI":"10.3390\/tomography12080118","type":"journal-article","created":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T14:20:36Z","timestamp":1787322036000},"page":"118","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Where Does the Signal Go? Technical Challenges of CT Perfusion in Lacunar and Infratentorial Stroke"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3787-2243","authenticated-orcid":false,"given":"Nicola","family":"Morelli","sequence":"first","affiliation":[{"name":"Diagnostic Neuroradiology Unit, Guglielmo da Saliceto Hospital, Azienda USL di Piacenza, 29121 Piacenza, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8091-2063","authenticated-orcid":false,"given":"Marco","family":"Spallazzi","sequence":"additional","affiliation":[{"name":"Neurology Unit, Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3154-7634","authenticated-orcid":false,"given":"Eugenia","family":"Rota","sequence":"additional","affiliation":[{"name":"Neurology Unit, San Giacomo Hospital, 15067 Novi Ligure, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marina","family":"Biondi","sequence":"additional","affiliation":[{"name":"Diagnostic Neuroradiology Unit, Guglielmo da Saliceto Hospital, Azienda USL di Piacenza, 29121 Piacenza, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2794-5237","authenticated-orcid":false,"given":"Davide","family":"Colombi","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Imaging, Centro Diagnostico Rocca, 29121 Piacenza, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,8,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1056\/NEJMoa1804355","article-title":"MRI-guided thrombolysis for stroke with unknown time of onset","volume":"379","author":"Thomalla","year":"2018","journal-title":"N. Engl. J. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1056\/NEJMoa1713973","article-title":"Thrombectomy for stroke at 6 to 16 hours with selection by perfusion imaging","volume":"378","author":"Albers","year":"2018","journal-title":"N. Engl. J. Med."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1056\/NEJMoa1706442","article-title":"Thrombectomy 6 to 24 hours after stroke with a mismatch between deficit and infarct","volume":"378","author":"Nogueira","year":"2018","journal-title":"N. Engl. J. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1056\/NEJMoa1813046","article-title":"Thrombolysis guided by perfusion imaging up to 9 hours after onset of stroke","volume":"380","author":"Ma","year":"2019","journal-title":"N. Engl. J. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1007\/s11739-015-1299-0","article-title":"Computed tomography perfusion-based thrombolysis in wake-up stroke","volume":"10","author":"Morelli","year":"2015","journal-title":"Intern. Emerg. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1148\/radiol.09091021","article-title":"Certainty of stroke diagnosis: Incremental benefit with CT perfusion over noncontrast CT and CT angiography","volume":"255","author":"Hopyan","year":"2010","journal-title":"Radiology"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"49","DOI":"10.3174\/ajnr.A6925","article-title":"Acute ischemic stroke or epileptic seizure? Yield of CT perfusion in a \u201ccode stroke\u201d situation","volume":"42","author":"Lucas","year":"2021","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Cvikov\u00e1, M., Har\u0161\u00e1ny, M., Vinkl\u00e1rek, J., \u0160tefela, J., Fojtov\u00e1, I., and Mikul\u00edk, R. (2024). Effectiveness of computed tomography perfusion imaging in stroke management. Front. Neurol., 15.","DOI":"10.3389\/fneur.2024.1390501"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1586\/14737175.9.2.179","article-title":"Lacunar stroke","volume":"9","author":"Arboix","year":"2009","journal-title":"Expert Rev. Neurother."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1007\/s00415-009-5104-8","article-title":"Ischemic stroke of the cortical \u201chand knob\u201d area: Stroke mechanisms and prognosis","volume":"256","author":"Peters","year":"2009","journal-title":"J. Neurol."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Tan, M.Y.Q., Singhal, S., Ma, H., Chandra, R.V., Cheong, J., Clissold, B.B., Ly, J., Srikanth, V., and Phan, T.G. (2016). Examining subcortical infarcts in the era of acute multimodality CT imaging. Front. Neurol., 7.","DOI":"10.3389\/fneur.2016.00220"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1111\/j.1747-4949.2012.00816.x","article-title":"Single subcortical infarction associated with parental arterial disease: Important yet neglected subtype of atherothrombotic stroke","volume":"8","author":"Kim","year":"2013","journal-title":"Int. J. Stroke"},{"key":"ref_13","first-page":"67","article-title":"A method of calculating brain blood flow with a CT dynamic scanner","volume":"30","author":"Axel","year":"1981","journal-title":"Adv. Neurol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"662","DOI":"10.3174\/ajnr.A1487","article-title":"Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke, part 1: Theoretic basis","volume":"30","author":"Konstas","year":"2009","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Morelli, N., Spallazzi, M., Biondi, M., Rota, E., and Colombi, D. (2026). Understanding CT perfusion in acute ischemic stroke: How algorithms shape perfusion maps. Diagnostics, 16.","DOI":"10.3390\/diagnostics16121831"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and multi-energy CT: Principles, technical approaches, and clinical applications","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"20170079","DOI":"10.1259\/bjr.20170079","article-title":"Low radiation dose in computed tomography: The role of iodine","volume":"90","author":"Aschoff","year":"2017","journal-title":"Br. J. Radiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.neurad.2016.04.001","article-title":"Utilizing dual energy CT to improve CT diagnosis of posterior fossa ischemia","volume":"43","author":"Hixson","year":"2016","journal-title":"J. Neuroradiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"3435","DOI":"10.1161\/STROKEAHA.111.618355","article-title":"Cerebral blood flow is the optimal CT perfusion parameter for assessing infarct core","volume":"42","author":"Campbell","year":"2011","journal-title":"Stroke"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1148\/radiol.2511080983","article-title":"Difference in tracer delay-induced effect among deconvolution algorithms in CT perfusion analysis: Quantitative evaluation with digital phantoms","volume":"251","author":"Kudo","year":"2009","journal-title":"Radiology"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1148\/radiol.254082000","article-title":"Differences in CT perfusion maps generated by different commercial software: Quantitative analysis by using identical source data of acute stroke patients","volume":"254","author":"Kudo","year":"2010","journal-title":"Radiology"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1148\/radiol.12112618","article-title":"Accuracy and reliability assessment of CT and MR perfusion analysis software using a digital phantom","volume":"267","author":"Kudo","year":"2013","journal-title":"Radiology"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1923","DOI":"10.1161\/STROKEAHA.110.610618","article-title":"CT cerebral blood flow maps optimally correlate with admission diffusion-weighted imaging in acute stroke, but thresholds vary by postprocessing platform","volume":"42","author":"Kamalian","year":"2011","journal-title":"Stroke"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1111\/jon.13090","article-title":"CT perfusion extended-window ischemic core estimation: Bayesian algorithm versus oscillation-index singular value decomposition","volume":"33","author":"Morelli","year":"2023","journal-title":"J. Neuroimaging"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1136\/neurintsurg-2012-010404","article-title":"Low signal, high noise and large uncertainty make CT perfusion unsuitable for acute ischemic stroke patient selection for endovascular therapy","volume":"4","year":"2012","journal-title":"J. Neurointerv. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Bennink, E., Oosterbroek, J., Kudo, K., Viergever, M.A., Velthuis, B.K., and de Jong, H.W.A.M. (2015). Influence of thin-slice reconstruction on CT brain perfusion analysis. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0137766"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1161\/STROKEAHA.114.007117","article-title":"Limited reliability of computed tomographic perfusion acute infarct volume measurements compared with diffusion-weighted imaging in anterior circulation stroke","volume":"46","author":"Schaefer","year":"2015","journal-title":"Stroke"},{"key":"ref_28","first-page":"1077","article-title":"Multisection dynamic CT perfusion for acute cerebral ischemia: The \u201ctoggling-table\u201d technique","volume":"22","author":"Roberts","year":"2001","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_29","first-page":"720","article-title":"Dynamic perfusion CT: Optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients","volume":"25","author":"Wintermark","year":"2004","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.crad.2010.12.014","article-title":"Whole-brain dynamic CT angiography and perfusion imaging","volume":"66","author":"Orrison","year":"2011","journal-title":"Clin. Radiol."},{"key":"ref_31","unstructured":"American College of Radiology, American Society of Neuroradiology, and Society for Pediatric Radiology (2026, July 08). ACR\u2013ASNR\u2013SPR Practice Parameter for the Performance of Computed Tomography (CT) Perfusion in Neuroradiologic Imaging. Revised, Resolution 22. Available online: https:\/\/gravitas.acr.org\/PPTS\/GetDocumentView?docId=170."},{"key":"ref_32","unstructured":"U.S. Food and Drug Administration (2026, July 08). Letter to the Medical Imaging Technology Alliance Regarding CT Recommendations, Available online: https:\/\/www.fda.gov\/radiation-emitting-products\/initiative-reduce-unnecessary-radiation-exposure-medical-imaging\/letter-medical-imaging-technology-alliance-regarding-ct-recommendations."},{"key":"ref_33","unstructured":"American Association of Physicists in Medicine (2026, July 08). Adult Brain Perfusion CT Protocols, Version 2.0. Available online: https:\/\/www.aapm.org\/pubs\/CTProtocols\/documents\/AdultBrainPerfusionCT.pdf."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1260\/2040-2295.5.1.67","article-title":"Automatic detection of CT perfusion datasets unsuitable for analysis due to head movement of acute ischemic stroke patients","volume":"5","author":"Fahmi","year":"2014","journal-title":"J. Healthc. Eng."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"213","DOI":"10.2214\/AJR.05.2188","article-title":"Reproducibility of postprocessing of quantitative CT perfusion maps","volume":"188","author":"Sanelli","year":"2007","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.2214\/AJR.09.2845","article-title":"Arterial input function placement for accurate CT perfusion map construction in acute stroke","volume":"194","author":"Ferreira","year":"2010","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1007\/s00234-009-0516-9","article-title":"Automated versus manual post-processing of perfusion-CT data in patients with acute cerebral ischemia: Influence on interobserver variability","volume":"51","author":"Soares","year":"2009","journal-title":"Neuroradiology"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"8317","DOI":"10.1007\/s00330-021-08067-6","article-title":"Variation in arterial input function in a large multicenter computed tomography perfusion study","volume":"31","author":"Peerlings","year":"2021","journal-title":"Eur. Radiol."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"2657","DOI":"10.1111\/ene.14934","article-title":"Diagnostic and prognostic utility of computed tomography perfusion imaging in posterior circulation acute ischemic stroke: A systematic review and meta-analysis","volume":"28","author":"Katyal","year":"2021","journal-title":"Eur. J. Neurol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1007\/s00234-016-1743-5","article-title":"Diagnostic accuracy of whole-brain CT perfusion in the detection of acute infratentorial infarctions","volume":"58","author":"Bollwein","year":"2016","journal-title":"Neuroradiology"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1007\/s00415-025-12933-4","article-title":"Effectiveness of CT perfusion in posterior circulation stroke: Evaluation of perfusion abnormalities and associated clinical signs","volume":"272","author":"Furlanis","year":"2025","journal-title":"J. Neurol."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Zedde, M., Napoli, M., Grisendi, I., Assenza, F., Moratti, C., Valzania, F., and Pascarella, R. (2023). CT perfusion in lacunar stroke: A systematic review. Diagnostics, 13.","DOI":"10.3390\/diagnostics13091564"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"103903","DOI":"10.1016\/j.nicl.2025.103903","article-title":"CT perfusion lesions are present in most MRI-confirmed lacunar strokes","volume":"48","author":"Thomas","year":"2025","journal-title":"NeuroImage Clin."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"e70271","DOI":"10.1002\/mp.70271","article-title":"Robust filtering of thin-slice reconstructions improves lacunar stroke detection in CT perfusion imaging","volume":"53","author":"Vromans","year":"2026","journal-title":"Med. Phys."},{"key":"ref_45","first-page":"1434","article-title":"False-negative diffusion-weighted MR findings in acute ischemic stroke","volume":"21","author":"Oppenheim","year":"2000","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1212\/WNL.0000000000004120","article-title":"Diagnosis of DWI-negative acute ischemic stroke: A meta-analysis","volume":"89","author":"Edlow","year":"2017","journal-title":"Neurology"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Alkhiri, A., Alturki, F., Alansari, N.M., Almaghrabi, A.A., Alghamdi, B.A., Alamri, A.F., Alghamdi, S., and Makkawi, S. (2024). Prognosis and distribution of ischemic stroke with negative diffusion-weighted imaging: A systematic review and meta-analysis. Front. Neurol., 15.","DOI":"10.3389\/fneur.2024.1376439"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1161\/STROKEAHA.115.008718","article-title":"Additional diagnostic value of computed tomography perfusion for detection of acute ischemic stroke in the posterior circulation","volume":"46","author":"Dankbaar","year":"2015","journal-title":"Stroke"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.nicl.2013.06.017","article-title":"Multi-delay multiparametric arterial spin-labeled perfusion MRI in acute ischemic stroke\u2014Comparison with dynamic susceptibility contrast-enhanced perfusion imaging","volume":"3","author":"Wang","year":"2013","journal-title":"NeuroImage Clin."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1212\/WNL.43.5.957","article-title":"The capsular warning syndrome: Pathogenesis and clinical features","volume":"43","author":"Donnan","year":"1993","journal-title":"Neurology"},{"key":"ref_51","first-page":"e316","article-title":"2026 guideline for the early management of patients with acute ischemic stroke: A guideline from the American Heart Association\/American Stroke Association","volume":"57","author":"Prabhakaran","year":"2026","journal-title":"Stroke"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"4199","DOI":"10.1002\/mp.14351","article-title":"Automatic arterial input function selection in CT and MR perfusion datasets using deep convolutional neural networks","volume":"47","author":"Winder","year":"2020","journal-title":"Med. Phys."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"102971","DOI":"10.1016\/j.media.2023.102971","article-title":"Spatio-temporal physics-informed learning: A novel approach to CT perfusion analysis in acute ischemic stroke","volume":"90","author":"Hoving","year":"2023","journal-title":"Med. Image Anal."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"109134","DOI":"10.1016\/j.compbiomed.2024.109134","article-title":"CT perfusion parameter estimation in stroke using neural network with transformer and physical model priors","volume":"182","author":"Luo","year":"2024","journal-title":"Comput. Biol. Med."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"102211","DOI":"10.1016\/j.media.2021.102211","article-title":"AIFNet: Automatic vascular function estimation for perfusion analysis using deep learning","volume":"74","author":"Sima","year":"2021","journal-title":"Med. Image Anal."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"2535","DOI":"10.3174\/ajnr.A8857","article-title":"CT perfusion map generation from multiphase CTA using a generative adversarial model for acute ischemic stroke","volume":"46","author":"Cai","year":"2025","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"2257","DOI":"10.3174\/ajnr.A5402","article-title":"Photon-counting CT of the brain: In vivo human results and image-quality assessment","volume":"38","author":"Pourmorteza","year":"2017","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"2624","DOI":"10.3174\/ajnr.A8910","article-title":"Photon-counting detector CT of the brain reduces variability of Hounsfield units and has a mean offset compared with energy-integrating detector CT","volume":"46","author":"Stein","year":"2025","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1097\/RLI.0000000000000418","article-title":"Photon-counting computed tomography for vascular imaging of the head and neck: First in vivo human results","volume":"53","author":"Symons","year":"2018","journal-title":"Investig. Radiol."}],"container-title":["Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2379-139X\/12\/8\/118\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T04:18:48Z","timestamp":1787631528000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2379-139X\/12\/8\/118"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,21]]},"references-count":59,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["tomography12080118"],"URL":"https:\/\/doi.org\/10.3390\/tomography12080118","relation":{},"ISSN":["2379-139X"],"issn-type":[{"value":"2379-139X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,21]]}}}