{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T13:07:13Z","timestamp":1789477633853,"version":"build-2803163510"},"reference-count":24,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T00:00:00Z","timestamp":1789430400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science Grants-in-Aid for Scientific Research","doi-asserted-by":"publisher","award":["24K18775"],"award-info":[{"award-number":["24K18775"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Tomography"],"abstract":"<jats:p>Background\/Objectives: To evaluate the clinical feasibility, safety, and geometric characteristics of a supine CT-guided posterior approach using a custom dorsal-space mat in patients for whom the supine position was required or preferred. Methods: This retrospective study included 16 consecutive patients prepared for the approach. Puncture trajectory parameters, positional stability, technical success, procedure time, and adverse events were evaluated in successfully positioned patients (n = 15; 35 trajectories). A geometric model was constructed to estimate maximum allowable puncture angles determined by mat height, needle length, and table geometry. Results: Positioning feasibility was 15\/16 (93.8%); one patient was converted to a lateral approach due to shoulder pain. Technical success was 100% per patient (15\/15) and per trajectory (35\/35). The mean puncture angle and depth were 40.2\u00b0 \u00b1 9.1\u00b0 and 8.3 \u00b1 2.5 cm, respectively. All puncture angles were within theoretical geometric limits, with a mean angular margin of 14.9\u00b0 \u00b1 10.9\u00b0. Quantitative stability assessment was feasible in 14 patients; median two-dimensional displacement and absolute axial rotation were 4.1 mm (IQR, 3.3\u20134.5 mm) and 0.9\u00b0 (IQR, 0.3\u20131.2\u00b0), respectively. Between-group differences observed in the trajectory-level analysis were not statistically significant in the patient-level sensitivity analysis. One Grade 5 adverse event occurred after RFA; although a relationship with the procedure could not be excluded, it was unrelated to the mat or puncture trajectory. Conclusions: This preliminary feasibility study suggests that the dorsal-space mat can provide sufficient working space for CT-guided posterior procedures while maintaining the supine position. Larger prospective studies are required to establish its broader clinical applicability and safety.<\/jats:p>","DOI":"10.3390\/tomography12090134","type":"journal-article","created":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T11:57:34Z","timestamp":1789473454000},"page":"134","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Supine CT-Guided Posterior Approach Using a Dorsal-Space Mat: Initial Clinical Experience and Geometric Characterization"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2021-7827","authenticated-orcid":false,"given":"Yuya","family":"Koike","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Nihon University School of Medicine, 30-1, Oyaguchi Kami-cho, Itabashi-ku, Tokyo 173-8610, Japan"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"software","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0725-6880","authenticated-orcid":false,"given":"Tatsuo","family":"Ueda","sequence":"additional","affiliation":[{"name":"Department of Radiology, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo 113-8603, Japan"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"validation","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"given":"Fumie","family":"Sugihara","sequence":"additional","affiliation":[{"name":"Department of Radiology, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo 113-8603, Japan"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"}]},{"given":"Masashi","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Nihon University School of Medicine, 30-1, Oyaguchi Kami-cho, Itabashi-ku, Tokyo 173-8610, Japan"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1016\/j.diii.2016.05.001","article-title":"Simultaneous biopsy and radiofrequency ablation of T1a renal cell carcinoma","volume":"97","author":"Iguchi","year":"2016","journal-title":"Diagn. Interv. Imaging"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Bondarenko, M., Zhang, J., Baal, U.H., Lam, B., Chaudhari, G., Lee, Y.J., Schroeder, J., Vella, M., Haas, B., and Vu, T. (2025). Development and validation of a risk nomogram predicting pneumothorax requiring chest tube placement post-percutaneous CT-guided lung biopsy. BMC Med. Imaging, 25.","DOI":"10.1186\/s12880-025-01794-y"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1111\/j.1754-9485.2011.02283.x","article-title":"Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung","volume":"55","author":"Nakamura","year":"2011","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"4243","DOI":"10.1007\/s00330-020-07449-6","article-title":"Predictors of pneumothorax and chest drainage after percutaneous CT-guided lung biopsy: A prospective study","volume":"31","author":"Ruud","year":"2021","journal-title":"Eur. Radiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"29","DOI":"10.2214\/AJR.14.13151","article-title":"CT-guided fine-needle aspiration and core needle biopsies of pulmonary lesions: A single-center experience with 750 biopsies in Japan","volume":"204","author":"Takeshita","year":"2015","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/S0009-9260(97)80036-0","article-title":"Ilio-psoas abscesses: Percutaneous drainage under image guidance","volume":"52","author":"Gupta","year":"1997","journal-title":"Clin. Radiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1080\/13645706.2023.2174806","article-title":"Outcomes of C-arm cone-beam CT-guided percutaneous procedures for thoracolumbar spondylodiscitis","volume":"32","author":"Koike","year":"2023","journal-title":"Minim. Invasive Ther. Allied Technol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"3372","DOI":"10.1007\/s00330-018-5991-0","article-title":"Canceled or aborted CT-guided interventions: 13-year clinical experience at a tertiary care center","volume":"29","author":"Yakar","year":"2019","journal-title":"Eur. Radiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1007\/s00270-011-0138-6","article-title":"A new method of an axial puncture approach for draining loculated pleural effusions","volume":"34","author":"Takizawa","year":"2011","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1456","DOI":"10.1007\/s00270-021-02844-y","article-title":"Feasibility and safety of the craniocaudal approach for superior sulcus lesions of the thorax","volume":"44","author":"Koretsune","year":"2021","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1007\/s00270-022-03060-y","article-title":"CT-guided femoral approach for psoas muscle abscess drainage","volume":"45","author":"Hayashi","year":"2022","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1007\/s00270-017-1577-5","article-title":"A new CT-guided modified trocar technique for drainage of difficult locations abscesses","volume":"40","author":"Tyng","year":"2017","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"ref_13","first-page":"uaaf025","article-title":"Radiofrequency ablation of renal tumour in the supine position using a dorsal-space mat","volume":"11","author":"Koike","year":"2025","journal-title":"BJR Case Rep."},{"key":"ref_14","first-page":"130","article-title":"Computed tomography-guided drainage with modified trocar technique using a Drainaway drainage kit","volume":"8","author":"Togawa","year":"2023","journal-title":"Interv. Radiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jvir.2022.10.011","article-title":"Adverse event classification: Clarification and validation of the Society of Interventional Radiology specialty-specific system","volume":"34","author":"Baerlocher","year":"2023","journal-title":"J. Vasc. Interv. Radiol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s00270-016-1531-y","article-title":"CIRSE guidelines on percutaneous ablation of small renal cell carcinoma","volume":"40","author":"Krokidis","year":"2017","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1007\/s00330-011-2363-4","article-title":"CT-guided adrenal biopsy: Comparison of ipsilateral decubitus versus prone patient positioning for biopsy approach","volume":"22","author":"Odisio","year":"2012","journal-title":"Eur. Radiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1089\/end.2015.0373","article-title":"Anthropometric renal anatomic alterations between supine and prone positions in percutaneous renal ablation for renal cortical neoplasms","volume":"30","author":"Lusch","year":"2016","journal-title":"J. Endourol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1186\/s40001-025-03239-2","article-title":"Influence of prone, supine, and lateral positions during spine surgery on vascular, abdominal, and postural anatomy","volume":"30","author":"Smajic","year":"2025","journal-title":"Eur. J. Med. Res."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Br\u00f6nnimann, M.P., Manser, L., Maurer, M.H., Gebauer, B., Auer, T.A., Schnapauff, D., Collettini, F., Nguyen, T.-L., Komarek, A., and Krokidis, M.E. (2024). Enhanced positioning strategies to reduce pneumothorax in CT-guided lung biopsies. Diagnostics, 14.","DOI":"10.3390\/diagnostics14232639"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1148\/radiology.210.1.r99ja1759","article-title":"Pneumothorax and dependent versus nondependent patient position after needle biopsy of the lung","volume":"210","author":"Collings","year":"1999","journal-title":"Radiology"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1007\/s00270-019-02196-8","article-title":"Post-biopsy manoeuvres to reduce pneumothorax incidence in CT-guided transthoracic lung biopsies","volume":"42","author":"Huo","year":"2019","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1148\/radiol.11103506","article-title":"Rapid needle-out patient-rollover time after CT-guided transthoracic biopsy: Effect on pneumothorax rate","volume":"262","author":"McCarthy","year":"2012","journal-title":"Radiology"},{"key":"ref_24","first-page":"31","article-title":"Patient positioning after lung biopsy: Influence on pneumothorax incidence","volume":"54","author":"Masterson","year":"2003","journal-title":"Can. Assoc. Radiol. J."}],"container-title":["Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2379-139X\/12\/9\/134\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T12:24:21Z","timestamp":1789475061000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2379-139X\/12\/9\/134"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,15]]},"references-count":24,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["tomography12090134"],"URL":"https:\/\/doi.org\/10.3390\/tomography12090134","relation":{},"ISSN":["2379-139X"],"issn-type":[{"value":"2379-139X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,15]]}}}