{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T14:07:34Z","timestamp":1783951654764,"version":"3.55.0"},"reference-count":38,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T00:00:00Z","timestamp":1744156800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Orion Corporation, Espoo Finland"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Sciences"],"abstract":"<jats:p>Noninvasive blood pressure (NIBP) device performance in dogs may be influenced by extreme pressures and altered systemic vascular resistance (SVR). This study evaluated the agreement of two NIBP devices (HDO and petMAP) with invasive blood pressure (IBP) measurements, compliance with hypertension consensus statement criteria, and their trending ability (TA) across varying blood pressure and SVR ranges in awake and anesthetized dogs. Seven healthy Beagles were studied, with IBP recorded from the dorsal metatarsal artery and NIBP cuffs placed randomly on the front limb, hind limb, or base of the tail. Cardiac output was determined by thermodilution, and the systemic vascular resistance index (SVRI) was calculated by a standard formula. Bland\u2013Altman, concordance rate, and polar plot analyses were used for statistical analysis. A total of 752 and 640 paired measurements were obtained for HDO and petMAP, respectively. Both devices showed good agreement with IBP for mean arterial pressure (MAP) at low blood pressure and the SVRI. At high blood pressure and the SVRI, agreement weakened, with substantial underestimation of systolic arterial pressure (SAP). Both devices demonstrated moderate to good TA for MAP and SAP. Overall, the best agreement was observed for MAP at a low SVRI, while agreement was moderate at hypertension (petMAP) and a high SVRI (petMAP, HDO).<\/jats:p>","DOI":"10.3390\/vetsci12040349","type":"journal-article","created":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T07:49:02Z","timestamp":1744184942000},"page":"349","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of Two Veterinary Oscillometric Noninvasive Blood Pressure (NIBP) Measurement Devices (petMAP Graphic II and High-Definition Oscillometry) in Dogs"],"prefix":"10.3390","volume":"12","author":[{"given":"Hanna","family":"Walter","sequence":"first","affiliation":[{"name":"Small Animal Clinic, University of Veterinary Medicine Hannover, 30559 Hannover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6430-6154","authenticated-orcid":false,"given":"Sabine B. R.","family":"K\u00e4stner","sequence":"additional","affiliation":[{"name":"Small Animal Clinic, University of Veterinary Medicine Hannover, 30559 Hannover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-3180-8048","authenticated-orcid":false,"given":"Thomas","family":"Amon","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus-Liebig-University, 35392 Gie\u00dfen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia M. A.","family":"T\u00fcnsmeyer","sequence":"additional","affiliation":[{"name":"Small Animal Clinic, University of Veterinary Medicine Hannover, 30559 Hannover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,4,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1161\/01.HYP.0000150857.39919.cb","article-title":"Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Recommendations for blood pressure measurement in humans and experimental animals. Part 2: Blood pressure measurement in experimental animals: A statement for professionals from the subcommittee of professional and public education of the American Heart Association council on high blood pressure research","volume":"45","author":"Kurtz","year":"2005","journal-title":"Hypertension"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.2460\/javma.1997.210.09.1279","article-title":"Arterial blood pressure monitoring in anesthetized animals","volume":"210","author":"Wagner","year":"1997","journal-title":"J. Am. Vet. Med. Assoc."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"F339","DOI":"10.1152\/ajprenal.2000.278.3.F339","article-title":"Renal physiology of the mouse","volume":"278","author":"Meneton","year":"2000","journal-title":"Am. J. Physiol. Ren. Physiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1152\/jappl.2000.88.5.1537","article-title":"A new method for measurement of blood pressure, heart rate, and activity in the mouse by radiotelemetry","volume":"88","author":"Mills","year":"2000","journal-title":"J. Appl. Physiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1053\/svms.2000.18292","article-title":"Direct blood pressure monitoring","volume":"15","author":"Waddell","year":"2000","journal-title":"Clin. Tech. Small Anim. Pract."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1111\/j.1467-2995.2012.00711.x","article-title":"Agreement between direct, oscillometric and Doppler ultrasound blood pressures using three different cuff positions in anesthetized dogs","volume":"39","author":"Garofalo","year":"2012","journal-title":"Vet. Anaesth. Analg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"205","DOI":"10.2460\/ajvr.1998.59.02.205","article-title":"Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs","volume":"59","author":"Grosenbaugh","year":"1998","journal-title":"Am. J. Vet. Res."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1111\/j.1467-2995.2004.00141.x","article-title":"Evaluation of a new oscillometric blood pressure monitor in isoflurane-anesthetized dogs","volume":"31","author":"Sawyer","year":"2004","journal-title":"Vet. Anaesth. Analg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1016\/j.jash.2014.08.014","article-title":"Oscillometric blood pressure: A review for clinicians","volume":"8","author":"Alpert","year":"2014","journal-title":"J. Am. Soc. Hypertens."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Pugsley, M.K., and Curtis, M.J. (2015). High Definition Oscillometry: Non-invasive Blood Pressure Measurement and Pulse Wave Analysis. Principles of Safety Pharmacology, Springer.","DOI":"10.1007\/978-3-662-46943-9"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"33","DOI":"10.21836\/PEM20150105","article-title":"Evaluation of accuracy of invasive and non-invasive blood pressure monitoring in relation to carotid artery pressure in anaesthetised ponies","volume":"31","author":"Gent","year":"2015","journal-title":"Pferdeheilkunde"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/vaa.12213","article-title":"A study of measurement of noninvasive blood pressure with the oscillometric device, Sentinel, in isoflurane-anaesthetized horses","volume":"42","author":"Hatz","year":"2015","journal-title":"Vet. Anaesth. Analg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1007\/s11259-010-9346-9","article-title":"Comparison of invasive and non-invasive blood pressure monitoring during clinical anaesthesia in dogs","volume":"34","author":"MacFarlane","year":"2010","journal-title":"Vet. Res. Commun."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.vaa.2024.02.001","article-title":"Anaesthetic-sparing effect of the anxiolytic drug tasipimidine in Beagle dogs","volume":"51","author":"Amon","year":"2024","journal-title":"Vet. Anaesth. Analg."},{"key":"ref_15","first-page":"80","article-title":"Invasive and noninvasive monitoring","volume":"1","author":"Shoemaker","year":"2000","journal-title":"Textb. Crit. Care"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"59","DOI":"10.5326\/JAAHA-MS-7055","article-title":"2020 AAHA anesthesia and monitoring guidelines for dogs and cats","volume":"56","author":"Grubb","year":"2020","journal-title":"J. Am. Anim. Hosp. Assoc."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.vaa.2024.03.005","article-title":"Effects of tasipimidine premedication with and without methadone and dexmedetomidine on cardiovascular variables during propofol-isoflurane anaesthesia in Beagle dogs","volume":"51","author":"Amon","year":"2024","journal-title":"Vet. Anaesth. Analg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1080\/10543400701329422","article-title":"Agreement between methods of measurement with multiple observations per individual","volume":"17","author":"Bland","year":"2007","journal-title":"J. Biopharm. Stat."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1053\/j.jvca.2011.01.003","article-title":"Assessment of trending ability of cardiac output monitors by polar plot methodology","volume":"25","author":"Critchley","year":"2011","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1111\/vec.12011","article-title":"Measuring the level of agreement between directly measured blood pressure and pressure readings obtained with a veterinary-specific oscillometric unit in anesthetized dogs","volume":"23","author":"Acierno","year":"2013","journal-title":"J. Vet. Emerg. Crit. Care"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1111\/j.1476-4431.2010.00520.x","article-title":"Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs","volume":"20","author":"Bosiack","year":"2010","journal-title":"J. Vet. Emerg. Crit. Care"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1111\/vaa.12203","article-title":"Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia","volume":"42","author":"Hopster","year":"2015","journal-title":"Vet. Anaesth. Analg."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1111\/j.1939-1676.2007.tb03005.x","article-title":"Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats","volume":"21","author":"Brown","year":"2007","journal-title":"J. Vet. Intern. Med.\/Am. Coll. Vet. Intern. Med."},{"key":"ref_24","first-page":"18","article-title":"Teil 1: Technologie und Vermeidung von Messfehlern","volume":"4","author":"Egner","year":"2006","journal-title":"Kleintier. Konkret-Die Z. Kleintierpraxis"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1111\/j.1476-4431.2010.00536.x","article-title":"Evaluation of an indirect oscillometric blood pressure monitor in normotensive and hypotensive anesthetized dogs","volume":"20","author":"Shih","year":"2010","journal-title":"J. Vet. Emerg. Crit. Care"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.rvsc.2014.05.003","article-title":"Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs","volume":"97","author":"Vachon","year":"2014","journal-title":"Res. Vet. Sci."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1111\/j.1748-5827.2010.00938.x","article-title":"Evaluation of high-definition and conventional oscillometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines","volume":"51","author":"Wernick","year":"2010","journal-title":"J. Small Anim. Pract."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1111\/j.1467-2995.2012.00774.x","article-title":"Comparison of high definition oscillometric and Doppler ultrasound devices with invasive blood pressure in anaesthetized dogs","volume":"40","author":"Seliskar","year":"2013","journal-title":"Vet. Anaesth. Analg."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1111\/vaa.12035","article-title":"A clinical comparison between a non-invasive blood pressure monitor using high definition oscillometry (Memodiagnostic MD 15\/90 Pro) and invasive arterial blood pressure measurement in anaesthetized dogs","volume":"40","author":"Rysnik","year":"2013","journal-title":"Vet. Anaesth. Analg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"402","DOI":"10.2460\/javma.237.4.402","article-title":"Agreement between directly measured blood pressure and pressures obtained with three veterinary-specific oscillometric units in cats","volume":"237","author":"Acierno","year":"2010","journal-title":"J. Am. Vet. Med. Assoc."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1213\/ANE.0000000000000965","article-title":"The Accuracy of the CNAP (R) device compared with Invasive radial artery measurements for providing continuous noninvasive arterial blood pressure readings at a medical intensive care unit: A method-comparison study","volume":"121","author":"Smolle","year":"2015","journal-title":"Anesth. Analg."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1093\/bja\/aeu055","article-title":"Use of the Nexfin (TM) device to detect acute arterial pressure variations during anaesthesia induction","volume":"113","author":"Weiss","year":"2014","journal-title":"Br. J. Anaesth."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"300","DOI":"10.5326\/JAAHA-MS-6163","article-title":"Agreement between Doppler and invasive blood pressure monitoring in anesthetized dogs weighing <5 kg","volume":"51","author":"Kennedy","year":"2015","journal-title":"J. Am. Anim. Hosp. Assoc."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1177\/1098612X13495025","article-title":"Comparison of high-definition oscillometry\u2014A non-invasive technology for arterial blood pressure measurement\u2014With a direct invasive method using radio-telemetry in awake healthy cats","volume":"15","author":"Martel","year":"2013","journal-title":"J. Feline Med. Surg."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1111\/vec.12075","article-title":"Comparison of invasive versus noninvasive blood pressure measurements before and after hemorrhage in anesthetized greyhounds using the Surgivet V9203","volume":"23","author":"Drynan","year":"2013","journal-title":"J. Vet. Emerg. Crit. Care"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Grimm, K.A., Lamont, L.A., Tranquilli, W.J., Greene, S.A., and Robertson, S.A. (2015). Monitoring anesthetized patients. Veterinary Anesthesia and Analgesia the Fifth Edition of Lumb and Jones, Wiley Blackwell.","DOI":"10.1002\/9781119421375"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1097\/00000542-198012000-00011","article-title":"The dynamic responses of liquid-filled catheter systems for direct measurements of blood pressure","volume":"53","author":"Shinozaki","year":"1980","journal-title":"Anesthesiology"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1016\/j.vaa.2017.07.002","article-title":"Validation of noninvasive blood pressure equipment: Which peripheral artery is best for comparison studies in dogs?","volume":"44","author":"Ramos","year":"2017","journal-title":"Vet. Anaesth. Analg."}],"container-title":["Veterinary Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-7381\/12\/4\/349\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:11:33Z","timestamp":1760029893000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-7381\/12\/4\/349"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,9]]},"references-count":38,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,4]]}},"alternative-id":["vetsci12040349"],"URL":"https:\/\/doi.org\/10.3390\/vetsci12040349","relation":{},"ISSN":["2306-7381"],"issn-type":[{"value":"2306-7381","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,9]]}}}