{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T21:06:30Z","timestamp":1769720790827,"version":"3.49.0"},"reference-count":33,"publisher":"MDPI AG","issue":"20","license":[{"start":{"date-parts":[[2021,10,9]],"date-time":"2021-10-09T00:00:00Z","timestamp":1633737600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Applied Sciences"],"abstract":"<jats:p>Experimental research studies have shown that wearing a mouthguard (MG) is an effective way to prevent tooth or maxillofacial trauma. However, there is a lack of scientific information regarding how the material arrangement within the mouthguard can modify its mechanical response during an impact. Hence, this study aimed to evaluate the influence of material arrangement within custom-made mouthguards on stress transmitted to anterior teeth, bone, and soft tissue after impact. Four 3D finite element models of a human maxilla were reconstructed based on the CBCT of a young patient and analyzed according to the presence or absence of a mouthguard and the type of material arrangement within those with a mouthguard: model NMG with no mouthguard; model CMG representing the conventional arrangement with a single 4 mm-thick ethylene-vinyl acetate (EVA) foil; model FMG presenting layer arrangement with two 1 mm-thick foils of EVA in the outer shell and one 2 mm-thick foil of EVA foam in the core; model HMG presenting a 1 mm-thick compact inner and outer shell of EVA and a 2 mm wide air-filled zone in the core. Linear quasi-static analysis and frontal load were used to simulate an impact with an energy of 4.4 J. Isotropic linear elastic properties were assumed for the bone and teeth but not for the mouthguard protection and oral soft tissues. The results were evaluated and compared in terms of displacement, stretches, and stresses. All the mouthguards analyzed reduced the risk of injury to teeth and bone, reducing the displacement and stress of these structures. However, the implementation of a honeycomb structured layer allowed more significant displacement and deformation of the mouthguard\u2019s external layer, thus promoting higher protection of the anatomic structures, namely the root dentin and the bone tissue. Nevertheless, the results also indicate that improving the mouthguard flexibility might increase the soft tissue injuries.<\/jats:p>","DOI":"10.3390\/app11209363","type":"journal-article","created":{"date-parts":[[2021,10,10]],"date-time":"2021-10-10T21:19:32Z","timestamp":1633900772000},"page":"9363","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["The Effectiveness of Dental Protection and the Material Arrangement in Custom-Made Mouthguards"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4019-9379","authenticated-orcid":false,"given":"Ana","family":"Messias","sequence":"first","affiliation":[{"name":"Center for Mechanical Engineering, Materials and Processes (CEMMPRE), Department of Mechanical Engineering, University of Coimbra, 3030-788 Coimbra, Portugal"},{"name":"Center for Mechanical Engineering, Materials and Processes (CEMMPRE), Department of Dentistry, University of Coimbra, 3030-788 Coimbra, Portugal"}]},{"given":"In\u00eas J.","family":"Gomes","sequence":"additional","affiliation":[{"name":"Center for Mechanical Engineering, Materials and Processes (CEMMPRE), Department of Mechanical Engineering, University of Coimbra, 3030-788 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5203-3670","authenticated-orcid":false,"given":"Paulo N. B.","family":"Reis","sequence":"additional","affiliation":[{"name":"Center for Mechanical Engineering, Materials and Processes (CEMMPRE), Department of Mechanical Engineering, University of Coimbra, 3030-788 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5237-0773","authenticated-orcid":false,"given":"Ana M.","family":"Amaro","sequence":"additional","affiliation":[{"name":"Center for Mechanical Engineering, Materials and Processes (CEMMPRE), Department of Mechanical Engineering, University of Coimbra, 3030-788 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3030-0146","authenticated-orcid":false,"given":"Maria A.","family":"Neto","sequence":"additional","affiliation":[{"name":"Center for Mechanical Engineering, Materials and Processes (CEMMPRE), Department of Mechanical Engineering, University of Coimbra, 3030-788 Coimbra, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2021,10,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"63","DOI":"10.3221\/IGF-ESIS.57.06","article-title":"Impact response of different materials for sports mouthguards","volume":"15","author":"Moreira","year":"2021","journal-title":"Frat. ed Integrit\u00e0 Strutt."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1016\/j.dental.2018.03.022","article-title":"Evaluation of the filler packing structures in dental resin composites: From theory to practice","volume":"34","author":"Wang","year":"2018","journal-title":"Dent. Mater."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.jmbbm.2019.02.009","article-title":"Mechanical behavior of restorative dental composites under various loading conditions","volume":"93","author":"Khosravani","year":"2019","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"117","DOI":"10.2165\/00007256-200737020-00003","article-title":"Mouthguards in sport: Activities history, physical properties and injury prevention effectiveness","volume":"37","author":"Knapik","year":"2007","journal-title":"Sport. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1308\/205016817821281738","article-title":"The Role of Mouthguards in Preventing and Reducing Sports-related Trauma","volume":"6","author":"Green","year":"2017","journal-title":"Prim. Dent. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1111\/edt.12520","article-title":"Risk of ankylosis of 400 avulsed and replanted human teeth in relation to length of dry storage: A re-evaluation of a long-term clinical study","volume":"36","author":"Lauridsen","year":"2020","journal-title":"Dent. Traumatol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1111\/j.1600-4469.2004.00210.x","article-title":"The influence of impact object characteristics on impact force and force absorption by mouthguard material","volume":"20","author":"Takeda","year":"2004","journal-title":"Dent. Traumatol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"335","DOI":"10.11607\/jomi.5803","article-title":"Mouthguard Biomechanics for Protecting Dental Implants from Impact: Experimental and Finite Element Impact Analysis","volume":"33","author":"Carvalho","year":"2018","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1007\/s10439-019-02267-4","article-title":"Mechanical Safety of Embedded Electronics for In-body Wearables: A Smart Mouthguard Study","volume":"47","author":"Bridgman","year":"2019","journal-title":"Ann. Biomed. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1111\/j.1834-7819.2000.tb00237.x","article-title":"The effect on energy absorption of hard inserts in laminated EVA mouthguards","volume":"45","author":"Westerman","year":"2000","journal-title":"Aust. Dent. J."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1034\/j.1600-9657.2002.180103.x","article-title":"EVA mouthguards: How thick should they be?","volume":"18","author":"Westerman","year":"2002","journal-title":"Dent. Traumatol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1097\/00005768-200206000-00006","article-title":"The effect of mouthguard design on stresses in the tooth-bone complex","volume":"34","author":"Cummins","year":"2002","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1111\/edt.12210","article-title":"Custom-Fitted EVA Mouthguards: What is the ideal thickness? A dynamic finite element impact study","volume":"32","author":"Verissimo","year":"2016","journal-title":"Dent. Traumatol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1136\/bjsm.36.1.51","article-title":"Beneficial effects of air inclusions on the performance of ethylene vinyl acetate (EVA) mouthguard material","volume":"36","author":"Westerman","year":"2002","journal-title":"Br. J. Sports Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1111\/j.1600-9657.2006.00361.x","article-title":"Does hard insertion and space improve shock absorption ability of mouthguard?","volume":"22","author":"Takeda","year":"2006","journal-title":"Dent. Traumatol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1177\/1943387520980237","article-title":"Biomechanical Analysis of a Custom-Made Mouthguard Reinforced With Different Elastic Modulus Laminates During a Simulated Maxillofacial Trauma","volume":"14","author":"Tribst","year":"2021","journal-title":"Craniomaxillofacial Trauma Reconstr."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Neto, M.A., Amaro, A., Luis, R., Cirne, J., and Leal, R. (2015). Engineering Computation of Structures: The Finite Element Method, Springer.","DOI":"10.1007\/978-3-319-17710-6"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Messias, A., Neto, M.A., Amaro, A.M., Lopes, V.M., and Nicolau, P. (2021). Mechanical evaluation of implant-assisted removable partial dentures in kennedy class i patients: Finite element design considerations. Appl. Sci., 11.","DOI":"10.3390\/app11020659"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1177\/154405910208100907","article-title":"Edentulation alters material properties of cortical bone in the human mandible","volume":"81","author":"Dechow","year":"2002","journal-title":"J. Dent. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1002\/ajpa.10121","article-title":"Variations in cortical material properties throughout the human dentate mandible","volume":"120","author":"Dechow","year":"2003","journal-title":"Am. J. Phys. Anthropol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/j.medengphy.2010.03.009","article-title":"Determination of Young\u2019s modulus of mandibular bone using inverse analysis","volume":"32","author":"Odin","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1080\/10255842.2017.1348501","article-title":"Effect of round curvature of anterior implant-supported zirconia frameworks: Finite element analysis and in vitro study using digital image correlation","volume":"20","author":"Messias","year":"2017","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1038\/ijos.2014.21","article-title":"Review of research on the mechanical properties of the human tooth","volume":"6","author":"Zhang","year":"2014","journal-title":"Int. J. Oral Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1111\/edt.12265","article-title":"A three-dimensional finite element analysis of the sports mouthguard","volume":"32","author":"Gialain","year":"2016","journal-title":"Dent. Traumatol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s11332-018-0488-4","article-title":"Simulation of mouthguard use in preventing dental injuries caused by different impacts in sports activities","volume":"15","author":"Paulo","year":"2019","journal-title":"Sport Sci. Health"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Borges, A.L.S., Dal Piva, A.M.D.O., Conc\u00edlio, L.R.D.S., Paes-Junior, T.J.D.A., and Tribst, J.P.M. (2020). Mouthguard use effect on the biomechanical response of an ankylosed maxillary central incisor during a traumatic impact: A 3-dimensional finite element analysis. Life, 10.","DOI":"10.3390\/life10110294"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1111\/edt.12577","article-title":"Mouthguard use and TMJ injury prevention with different occlusions: A three-dimensional finite element analysis","volume":"36","author":"Tribst","year":"2020","journal-title":"Dent. Traumatol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1111\/edt.12063","article-title":"Shock absorption ability of mouthguard against forceful, traumatic mandibular closure","volume":"30","author":"Ozawa","year":"2014","journal-title":"Dent. Traumatol."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Mordini, L., Lee, P., Lazaro, R., Biagi, R., and Giannetti, L. (2021). Sport and Dental Traumatology: Surgical Solutions and Prevention. Dent. J., 9.","DOI":"10.3390\/dj9030033"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1687","DOI":"10.1016\/j.joen.2016.07.018","article-title":"Influence of Dentoalveolar Ankylosis on the Biomechanical Response of a Single-rooted Tooth and Surrounding Alveolar Bone: A 3-dimensional Finite Element Analysis","volume":"42","author":"Jang","year":"2016","journal-title":"J. Endod."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1002\/ar.a.20358","article-title":"Material properties of the dentate maxilla","volume":"288","author":"Peterson","year":"2006","journal-title":"Anat. Rec.\u2014Part A Discov. Mol. Cell. Evol. Biol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.joen.2018.04.004","article-title":"Biomechanical Properties of First Maxillary Molars with Different Endodontic Cavities: A Finite Element Analysis","volume":"44","author":"Jiang","year":"2018","journal-title":"J. Endod."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Neto, M.A., Roseiro, L., Messias, A., Falacho, R.I., Palma, P.J., and Amaro, A.M. (2021). Influence of cavity geometry on the fracture strength of dental restorations: Finite element study. Appl. Sci., 11.","DOI":"10.3390\/app11094218"}],"container-title":["Applied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2076-3417\/11\/20\/9363\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:10:53Z","timestamp":1760166653000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2076-3417\/11\/20\/9363"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,9]]},"references-count":33,"journal-issue":{"issue":"20","published-online":{"date-parts":[[2021,10]]}},"alternative-id":["app11209363"],"URL":"https:\/\/doi.org\/10.3390\/app11209363","relation":{},"ISSN":["2076-3417"],"issn-type":[{"value":"2076-3417","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,9]]}}}