{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T20:43:00Z","timestamp":1770842580795,"version":"3.50.1"},"reference-count":45,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2022,2,23]],"date-time":"2022-02-23T00:00:00Z","timestamp":1645574400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Applied Sciences"],"abstract":"<jats:p>The monitoring of fracture or osteotomy healing is vital for orthopedists to help advise, if necessary, secondary treatments for improving healing outcomes and minimizing patient suffering. It has been decades since osteotomy stiffness has been identified as one main parameter to quantify and qualify the outcome of a regenerated callus. Still, radiographic imaging remains the current standard diagnostic technique of orthopedists. Hence, with recent technological advancements, engineers need to use the new branches of knowledge and improve or innovate diagnostic technologies. An electromechanical system was developed to help diagnose changes in osteotomy stiffness treated with the external fixator LRS Orthofix\u00ae. The concept was evaluated experimentally and numerically during fracture healing simulation using two different models: a simplified model of a human tibia, consisting of a nylon bar with a diameter of 30 mm, and a synthetic tibia with the anatomical model from fourth-generation Sawbones\u00ae. Moreover, Sawbones\u00ae blocks with different densities simulated the mechanical characteristics of the regenerated bone in many stages of bone callus growth. The experimental measurements using the developed diagnostic were compared to the numerically simulated results. For this external fixator, it was possible to show that the displacement in osteotomy was always lower than the displacement prescribed in the elongator. Nevertheless, a relationship was established between the energy consumption by the electromechanical system used to perform callus stimulus and the degree of osteotomy consolidation. Hence, this technology may lead to methodologies of mechanical stimulation for regenerating bone, which will play a relevant role for bedridden individuals with mobility limitations.<\/jats:p>","DOI":"10.3390\/app12052328","type":"journal-article","created":{"date-parts":[[2022,2,23]],"date-time":"2022-02-23T09:34:38Z","timestamp":1645608878000},"page":"2328","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Evaluation of Bone Consolidation in External Fixation with an Electromechanical System"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9838-1299","authenticated-orcid":false,"given":"Maria F.","family":"Paulino","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Center for Mechanical Engineering, Materials and Processes (CEMMPRE), University of Coimbra, 3030-788 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6043-6007","authenticated-orcid":false,"given":"Luis M.","family":"Roseiro","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Center for Mechanical Engineering, Materials and Processes (CEMMPRE), University of Coimbra, 3030-788 Coimbra, Portugal"},{"name":"Polytechnic of Coimbra, ISEC, Rua Pedro Nunes\u2013Quinta da Nora, 3030-199 Coimbra, Portugal"}]},{"given":"In\u00eas","family":"Balac\u00f3","sequence":"additional","affiliation":[{"name":"Pediatric Orthopedics Service of the Pediatric Hospital of Coimbra\u2014CHUC, EPE, 3004-561 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3030-0146","authenticated-orcid":false,"given":"Maria A.","family":"Neto","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Center for Mechanical Engineering, Materials and Processes (CEMMPRE), University of Coimbra, 3030-788 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5237-0773","authenticated-orcid":false,"given":"Ana M.","family":"Amaro","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Center for Mechanical Engineering, Materials and Processes (CEMMPRE), University of Coimbra, 3030-788 Coimbra, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2022,2,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: Choosing a new balance between stability and biology","volume":"84","author":"Perren","year":"2002","journal-title":"J. Bone Joint Surg. Br."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1054\/cuor.2001.0211","article-title":"The biomechanics of frature fixation","volume":"15","author":"Cunningham","year":"2001","journal-title":"Curr. Orthop."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.orthres.2003.11.007","article-title":"The influence of cyclic compression and distraction on the healing of experimental tibial fractures","volume":"22","author":"Hente","year":"2004","journal-title":"J. Orthop. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2842","DOI":"10.1016\/j.injury.2017.10.036","article-title":"The psychological impact of external fixation using the Ilizarov or Orthofix LRS method to treat tibial osteomyelitis with a bone defect","volume":"48","author":"Abulaiti","year":"2017","journal-title":"Injury"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1636","DOI":"10.1016\/j.injury.2017.05.002","article-title":"Outcomes of post-traumatic tibial osteomyelitis treated with an Orthofix LRS versus an Ilizarov external fixator","volume":"48","author":"Yilihamu","year":"2017","journal-title":"Injury"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1177\/0954411918783782","article-title":"Optimization of Taylor spatial frame half-pins diameter for bone deformity correction: Application to femur","volume":"232","author":"Chavoshnejad","year":"2018","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"14060","DOI":"10.1109\/JSEN.2020.3033192","article-title":"Da Noninvasive Optical Instrumentation for Bone Healing Process Analysis","volume":"21","author":"Kalinowski","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Barcik, J., Epari, D.R., Ibrahim, T., Mercatali, L., and Maria Donati, D. (2021). Can Optimizing the Mechanical Environment Deliver a Clinically Significant Reduction in Fracture Healing Time?. Biomedicines, 9.","DOI":"10.3390\/biomedicines9060691"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"S101","DOI":"10.1016\/j.injury.2020.09.026","article-title":"Smart implants in fracture care\u2014Only buzzword or real opportunity?","volume":"52","author":"Ernst","year":"2021","journal-title":"Injury"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"41","DOI":"10.2147\/IEH.S133518","article-title":"Smart implants in orthopedic surgery, improving patient outcomes: A review","volume":"5","author":"Ledet","year":"2018","journal-title":"Innov. Entrep. Health"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2750","DOI":"10.1109\/TBME.2015.2422751","article-title":"From Wearable Sensors to Smart Implants\u2013Toward Pervasive and Personalized Healthcare","volume":"62","author":"Leff","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Lange, H.E., Arbeiter, N., Bader, R., and Kluess, D. (2021). Performance of a Piezoelectric Energy Harvesting System for an Energy-Autonomous Instrumented Total Hip Replacement: Experimental and Numerical Evaluation. Materials, 14.","DOI":"10.3390\/ma14185151"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/S0021-9290(00)00237-2","article-title":"Mechanical boundary conditions of fracture healing: Borderline indications in the treatment of unreamed tibial nailing","volume":"34","author":"Duda","year":"2001","journal-title":"J. Biomech."},{"key":"ref_14","unstructured":"ASM International Handbook Committee (1998). Properties and Selection: Nonferrous Alloys and Special-Purpose Materials. ASM Int., 2, 1143\u20131144."},{"key":"ref_15","unstructured":"Silva, R. (2017). Estudo Experimental Comparativo do Posicionamento dos Componentes Estruturais de um Fixador Externo, University of Coimbra."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Martins Amaro, A., Paulino, M.F., Roseiro, L.M., Neto, M.A., F\u00e1tima Paulino, M., Manuel Roseiro, L., and Augusta Neto, M. (2020). The Effect of External Fixator Configurations on the Dynamic Compression Load: An Experimental and Numerical Study. Appl. Sci., 10.","DOI":"10.3390\/app10010003"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1177\/1753193417702565","article-title":"Effect of interfragmentary gap on compression force in a headless compression screw used for scaphoid fixation","volume":"43","author":"Tan","year":"2018","journal-title":"J. Hand Surg. Eur. Vol."},{"key":"ref_18","unstructured":"Sawbones\u00ae (2019). Biomechanical Products Catalog, Sawbones\u00ae."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Ghiasi, M.S., Chen, J.E., Rodriguez, E.K., Vaziri, A., and Nazarian, A. (2019). Computational modeling of human bone fracture healing affected by different conditions of initial healing stage. BMC Musculoskelet. Disord., 20.","DOI":"10.1186\/s12891-019-2854-z"},{"key":"ref_20","first-page":"2280800019826512","article-title":"Investigation of load transfer process between external fixator and bone model by experimental and finite element methods","volume":"17","author":"Zhao","year":"2019","journal-title":"J. Appl. Biomater. Funct. Mater."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1016\/j.jbiomech.2005.01.037","article-title":"Comparison of biophysical stimuli for mechano-regulation of tissue differentiation during fracture healing","volume":"39","author":"Isaksson","year":"2006","journal-title":"J. Biomech."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1016\/S0021-9290(02)00086-6","article-title":"A mechano-regulation model for tissue differentiation during fracture healing: Analysis of gap size and loading","volume":"35","author":"Lacroix","year":"2002","journal-title":"J. Biomech."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.medengphy.2017.06.001","article-title":"FE and experimental study on how the cortex material properties of synthetic femurs affect strain levels","volume":"46","author":"Lopes","year":"2017","journal-title":"Med. Eng. Phys."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1302\/0301-620X.73B4.2071654","article-title":"Axial movement and tibial fractures. A controlled randomised trial of treatment","volume":"73","author":"Kenwright","year":"1991","journal-title":"J. Bone Joint Surg. Br."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1016\/j.clinbiomech.2010.03.003","article-title":"Influence of the fixation stability on the healing time--a numerical study of a patient-specific fracture healing process","volume":"25","author":"Wehner","year":"2010","journal-title":"Clin. Biomech."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1016\/j.injury.2010.08.018","article-title":"The influence of compression on the healing of experimental tibial fractures","volume":"42","author":"Sigurdsen","year":"2011","journal-title":"Injury"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1002\/jor.1100150414","article-title":"Influence of size and stability of the osteotomy gap on the success of fracture healing","volume":"15","author":"Claes","year":"1997","journal-title":"J. Orthop. Res."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1016\/j.medengphy.2016.07.007","article-title":"Influence of fracture geometry on bone healing under locking plate fixations: A comparison between oblique and transverse tibial fractures","volume":"38","author":"Miramini","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/1350-4533(95)00056-9","article-title":"The influence of external fixators on fracture motion during simulated walking","volume":"18","author":"Gardner","year":"1996","journal-title":"Med. Eng. Phys."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"677","DOI":"10.2106\/JBJS.15.01027","article-title":"Reverse Dynamization: Influence of Fixator Stiffness on the Mode and Efficiency of Large-Bone-Defect Healing at Different Doses of rhBMP-2","volume":"98","author":"Glatt","year":"2016","journal-title":"J. Bone Joint Surg. Am."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"678","DOI":"10.3389\/fphys.2016.00678","article-title":"A Concert between Biology and Biomechanics: The Influence of the Mechanical Environment on Bone Healing","volume":"7","author":"Glatt","year":"2017","journal-title":"Front. Physiol."},{"key":"ref_32","first-page":"115","article-title":"A theoretical analysis and finite element simulation of fixator\u2013bone system stiffness on healing progression","volume":"16","author":"Li","year":"2018","journal-title":"J. Appl. Biomater. Funct. Mater."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"211","DOI":"10.3389\/fendo.2014.00211","article-title":"Mechanical Regulation of Bone Regeneration: Theories, Models, and Experiments","volume":"5","author":"Betts","year":"2014","journal-title":"Front. Endocrinol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/1475-925X-2-8","article-title":"In vivo measurement of bending stiffness in fracture healing","volume":"2","author":"Hente","year":"2003","journal-title":"Biomed. Eng. Online"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1589","DOI":"10.1002\/jor.22721","article-title":"Temporal delimitation of the healing phases via monitoring of fracture callus stiffness in rats","volume":"32","author":"Wehner","year":"2014","journal-title":"J. Orthop. Res."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1002\/jor.22918","article-title":"Implantable microelectromechanical sensors for diagnostic monitoring and post-surgical prediction of bone fracture healing","volume":"33","author":"McGilvray","year":"2015","journal-title":"J. Orthop. Res."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.21037\/atm-21-1853","article-title":"Diagnostic prediction of ovine fracture healing outcomes via a novel multi-location direct electromagnetic coupling antenna","volume":"9","author":"Wolynski","year":"2021","journal-title":"Ann. Transl. Med."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2836","DOI":"10.1016\/j.jbiomech.2014.07.031","article-title":"Partial gravity unloading inhibits bone healing responses in a large animal model","volume":"47","author":"Gadomski","year":"2014","journal-title":"J. Biomech."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Tan, Y., Hu, J., Ren, L., Zhu, J., Yang, J., and Liu, D. (2017). A Passive and Wireless Sensor for Bone Plate Strain Monitoring. Sensors, 17.","DOI":"10.3390\/s17112635"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1016\/j.jbiomech.2003.12.025","article-title":"Three-dimensional load measurements in an external fixator","volume":"37","author":"Seide","year":"2004","journal-title":"J. Biomech."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1964","DOI":"10.1007\/s11999-009-0752-7","article-title":"Monitoring the Mechanical Properties of Healing Bone","volume":"467","author":"Claes","year":"2009","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1302\/0301-620X.94B3.27550","article-title":"Telemetric assessment of bone healing with an instrumented internal fixator: A preliminary study","volume":"94-B","author":"Seide","year":"2012","journal-title":"J. Bone Jt. Surg.-Ser. B"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1007\/s10439-009-9889-5","article-title":"Monitoring in vivo load transmission through an external fixator","volume":"38","author":"Grasa","year":"2010","journal-title":"Ann. Biomed. Eng."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1302\/0301-620X.67B4.4030869","article-title":"The influence of induced micromovement upon the healing of experimental tibial fractures","volume":"67","author":"Goodship","year":"1985","journal-title":"J. Bone Joint Surg. Br."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.1002\/jor.23812","article-title":"Early mechanical stimulation only permits timely bone healing in sheep","volume":"36","author":"Tufekci","year":"2018","journal-title":"J. Orthop. Res."}],"container-title":["Applied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2076-3417\/12\/5\/2328\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:26:27Z","timestamp":1760135187000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2076-3417\/12\/5\/2328"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,23]]},"references-count":45,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2022,3]]}},"alternative-id":["app12052328"],"URL":"https:\/\/doi.org\/10.3390\/app12052328","relation":{},"ISSN":["2076-3417"],"issn-type":[{"value":"2076-3417","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,23]]}}}