{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T21:02:59Z","timestamp":1778187779083,"version":"3.51.4"},"reference-count":52,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2025,7,6]],"date-time":"2025-07-06T00:00:00Z","timestamp":1751760000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e Tecnologia (FCT)","award":["2023.05546.BD"],"award-info":[{"award-number":["2023.05546.BD"]}]},{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e Tecnologia (FCT)","award":["2023.00413.BD"],"award-info":[{"award-number":["2023.00413.BD"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Applied Sciences"],"abstract":"<jats:p>Foot plantar pressure refers to the pressure or force that the foot generates in contact with the ground, varying across different regions of the foot. This parameter is essential in static and dynamic analyses to access accurate diagnoses, study the human body biomechanics, create functional footwear designs, aid in rehabilitation and physiotherapy, and prevent injuries in athletes during sports practice. This study presents an experimental comparison between two different plantar pressure measurement devices, Pedar\u00ae (sensorized insoles) and Physiosensing\u00ae (pressure platform). The devices were selected based on their capacity to measure contact area and peak pressure points. Results showed that Physiosensing\u00ae provided a more uniform measurement of the contact area, proving its efficiency for weight distribution and stability analysis applications, particularly in posture assessment and balance studies. The Pedar\u00ae system showed higher capacity in peak pressure point detection. Therefore, the insole system is more suitable for applications requiring precise high-pressure zone localization. Comparative analysis highlights the strengths and limitations of each device and offers insights regarding its optimal usage in clinical, sports, and research settings.<\/jats:p>","DOI":"10.3390\/app15137575","type":"journal-article","created":{"date-parts":[[2025,7,7]],"date-time":"2025-07-07T10:03:27Z","timestamp":1751882607000},"page":"7575","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Comparative Analysis of Pressure Platform and Insole Devices for Plantar Pressure Assessment"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0334-3503","authenticated-orcid":false,"given":"Catarina M.","family":"Amaro","sequence":"first","affiliation":[{"name":"University of Coimbra, CIPER (Interdisciplinary Center for Human Performance), Faculty of Sports Science and Physical Education, 3040-248 Coimbra, Portugal"},{"name":"University of Coimbra, CEMMPRE\u2014ARISE Department of Mechanical Engineering, 3040-248 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9838-1299","authenticated-orcid":false,"given":"Maria F.","family":"Paulino","sequence":"additional","affiliation":[{"name":"University of Coimbra, CEMMPRE\u2014ARISE Department of Mechanical Engineering, 3040-248 Coimbra, Portugal"}]},{"given":"Sara","family":"Valvez","sequence":"additional","affiliation":[{"name":"University of Coimbra, CEMMPRE\u2014ARISE Department of Mechanical Engineering, 3040-248 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6043-6007","authenticated-orcid":false,"given":"Luis","family":"Roseiro","sequence":"additional","affiliation":[{"name":"University of Coimbra, CEMMPRE\u2014ARISE Department of Mechanical Engineering, 3040-248 Coimbra, Portugal"},{"name":"Coimbra Institute of Engineering, Polytechnic University of Coimbra, 3030-199 Coimbra, Portugal"},{"name":"Research Center for Natural Resources, Environment and Society (CERNAS), Polytechnic University of Coimbra, 3045-601 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1500-355X","authenticated-orcid":false,"given":"Maria Ant\u00f3nio","family":"Castro","sequence":"additional","affiliation":[{"name":"University of Coimbra, CEMMPRE\u2014ARISE Department of Mechanical Engineering, 3040-248 Coimbra, Portugal"},{"name":"School of Health Sciences, ciTechCare, CDRSP, Polytechnic University of Leiria, 2411-901 Leiria, Portugal"},{"name":"RoboCorp Lab, i2a\u2014IPC Polytechnic Institute of Coimbra, 3045-093 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5237-0773","authenticated-orcid":false,"given":"Ana M.","family":"Amaro","sequence":"additional","affiliation":[{"name":"University of Coimbra, CEMMPRE\u2014ARISE Department of Mechanical Engineering, 3040-248 Coimbra, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2025,7,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Re, R., Scano, A., Amata, O., Spinelli, L., Tomba, A., Brambilla, C., Frizziero, A., Caserta, A.V., Cubeddu, R., and Torricelli, A. (2024). A personalized clinical assessment: Multi-sensor approach for understanding musculoskeletal health in the frail population. Biomed. Eng. Online, 23.","DOI":"10.1186\/s12938-024-01287-z"},{"key":"ref_2","unstructured":"Kobayashi, Y., and Nakashima, Y. (2024). Estimation of posture and joint angle of human body using foot pressure distribution: Morphological computation with human foot. arXiv."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.gaitpost.2018.03.005","article-title":"Foot posture is associated with plantar pressure during gait: A comparison of normal, planus and cavus feet","volume":"62","author":"Buldt","year":"2018","journal-title":"Gait Posture"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.gaitpost.2018.02.026","article-title":"The relationship between foot posture and plantar pressure during walking in adults: A systematic review","volume":"62","author":"Buldt","year":"2018","journal-title":"Gait Posture"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1093\/ptj\/80.4.399","article-title":"Plantar Pressure Assessment","volume":"80","author":"Orlin","year":"2000","journal-title":"Phys. Ther."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"e26161","DOI":"10.1016\/j.heliyon.2024.e26161","article-title":"Plantar pressure thresholds as a strategy to prevent diabetic foot ulcers: A systematic review","volume":"10","author":"Marques","year":"2024","journal-title":"Heliyon"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1007\/s40200-019-00387-1","article-title":"Plantar pressure distribution in diverse stages of diabetic neuropathy","volume":"18","author":"Abri","year":"2019","journal-title":"J. Diabetes Metab. Disord."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"45","DOI":"10.4236\/jbise.2013.65A008","article-title":"Learning from experience: A simple effective protocol to test footwear prescriptions for the Diabetic foot by using the Pedar system","volume":"6","author":"Giacomozzi","year":"2013","journal-title":"J. Biomed. Sci. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"De Blasiis, P., Caravaggi, P., Fullin, A., Leardini, A., Lucariello, A., Perna, A., Guerra, G., and De Luca, A. (2023). Postural stability and plantar pressure parameters in healthy subjects: Variability, correlation analysis and differences under open and closed eye conditions. Front. Bioeng. Biotechnol., 11.","DOI":"10.3389\/fbioe.2023.1198120"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.msard.2018.01.023","article-title":"Investigating the dynamic plantar pressure distribution and loading pattern in subjects with multiple sclerosis","volume":"20","author":"Keklicek","year":"2018","journal-title":"Mult. Scler. Relat. Disord."},{"key":"ref_11","first-page":"80","article-title":"Plantar Pressure Distribution in People with Stroke and Association with Functional Mobility","volume":"6","author":"Forghany","year":"2019","journal-title":"J. Rehabil. Sci. Res."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"232.e1","DOI":"10.1016\/j.scispo.2020.05.006","article-title":"Differences among plantar pressure of acrobatic gymnasts when they jump over two competition floors. Does the presence of mattresses affect the gymnasts\u2019 performance?","volume":"36","author":"Paulino","year":"2021","journal-title":"Sci. Sports"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Amaro, C.M., Castro, M.A., Roseiro, L., Neto, M.A., and Amaro, A.M. (2020). Plantar pressure evaluation during the season in five basketball movements. Appl. Sci., 10.","DOI":"10.3390\/app10238691"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Santos, V.M., Gomes, B.B., Neto, M.A., and Amaro, A.M. (2024). A Systematic Review of Insole Sensor Technology: Recent Studies and Future Directions. Appl. Sci., 14.","DOI":"10.3390\/app14146085"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2100566","DOI":"10.1002\/admt.202100566","article-title":"Plantar Pressure-Based Insole Gait Monitoring Techniques for Diseases Monitoring and Analysis: A Review","volume":"7","author":"Chen","year":"2022","journal-title":"Adv. Mater. Technol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"9884","DOI":"10.3390\/s120709884","article-title":"Foot plantar pressure measurement system: A review","volume":"12","author":"Zayegh","year":"2012","journal-title":"Sensors"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Subramaniam, S., Majumder, S., Faisal, A.I., and Deen, M.J. (2022). Insole-Based Systems for Health Monitoring: Current Solutions and Research Challenges. Sensors, 22.","DOI":"10.3390\/s22020438"},{"key":"ref_18","unstructured":"Detels, K., Shin, D., Wilson, H., Zhou, S., Chen, A., Rosendorf, J., Taseh, A., Akhbari, B., Schwab, J.H., and Ghaednia, H. (2024). Clinical Applications of Plantar Pressure Measurement. arXiv."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"102094","DOI":"10.1016\/j.foot.2024.102094","article-title":"Testing protocols and measurement techniques when using pressure sensors for sport and health applications: A comparative review","volume":"59","author":"Burnie","year":"2024","journal-title":"Foot"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Crossland, S.R., Siddle, H.J., Brockett, C.L., and Culmer, P. (2023). Evaluating the Use of a Novel Low-Cost Measurement Insole to Characterise Plantar Foot Strain during Gait Loading Regimes. Front. Bioeng. Biotechnol., 11.","DOI":"10.3389\/fbioe.2023.1187710"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"109943","DOI":"10.1016\/j.measurement.2021.109943","article-title":"Textile-Film Sensors for a Comfortable Intelligent Pressure-Sensing Insole","volume":"184","author":"He","year":"2021","journal-title":"Measurement"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Samarentsis, A.G., Makris, G., Spinthaki, S., Christodoulakis, G., Tsiknakis, M., and Pantazis, A.K. (2022). A 3D-Printed Capacitive Smart Insole for Plantar Pressure Monitoring. Sensors, 22.","DOI":"10.3390\/s22249725"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Luna-Perej\u00f3n, F., Salvador-Dom\u00ednguez, B., Perez-Pe\u00f1a, F., Corral, J.M.R., Escobar-Linero, E., and Morgado-Est\u00e9vez, A. (2023). Smart Shoe Insole Based on Polydimethylsiloxane Composite Capacitive Sensors. Sensors, 23.","DOI":"10.3390\/s23031298"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"31278","DOI":"10.1109\/JSEN.2023.3330633","article-title":"Estimation of Three-Dimensional Ground Reaction Forces During Walking and Turning Using Insole Pressure Sensors Based on Gait Pattern Recognition","volume":"23","author":"Eguchi","year":"2023","journal-title":"IEEE Sens. J."},{"key":"ref_25","unstructured":"Willemstein, N., Sridar, S., Van Der Kooij, H., and Sadeghi, A. (2023). 3D Printed Graded Porous Sensors for Soft Sensorized Insoles with Gait Phase & Ground Reaction Forces Estimation. arXiv."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Choi, H.S., Yoon, S., Kim, J., Seo, H., and Choi, J.K. (2024). Calibrating Low-Cost Smart Insole Sensors with Recurrent Neural Networks for Accurate Prediction of Center of Pressure. Sensors, 24.","DOI":"10.3390\/s24154765"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Matthies, D.J.C., Roumen, T., Kuijper, A., and Urban, B. (2017, January 4\u20137). CapSoles. Proceedings of the 19th International Conference on Human-Computer Interaction with Mobile Devices and Services, Vienna, Austria.","DOI":"10.1145\/3098279.3098545"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Ivanov, K., Mei, Z., Lubich, L., Guo, N., Xile, D., Zhao, Z., Omisore, O.M., Ho, D., and Wang, L. (2019). Design of a Sensor Insole for Gait Analysis. Intelligent Robotics and Applications, Springer.","DOI":"10.1007\/978-3-030-27538-9_37"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.gaitpost.2005.05.008","article-title":"Accuracy and repeatability of the Pedar Mobile system in long-term vertical force measurements","volume":"23","author":"Hurkmans","year":"2006","journal-title":"Gait Posture"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1016\/j.gaitpost.2006.05.010","article-title":"The Pedar\u00ae in-shoe system: Repeatability and normal pressure values","volume":"25","author":"Putti","year":"2007","journal-title":"Gait Posture"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Quesada, P., Rash, G., and Jarboe, N. (1997). Assessment of pedar and F-scan revisited. Clin. Biomech., 12.","DOI":"10.1016\/S0268-0033(97)88328-3"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/0268-0033(91)90036-P","article-title":"Reliability of pressure measurements: The EM ED F system","volume":"6","author":"Hughes","year":"1991","journal-title":"Clin. Biomech."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1016\/j.gaitpost.2013.01.028","article-title":"Reliability of plantar pressure platforms","volume":"38","author":"Hafer","year":"2013","journal-title":"Gait Posture"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.gaitpost.2009.11.016","article-title":"Plantar pressure measurements using an in-shoe system and a pressure platform: A comparison","volume":"31","author":"Chevalier","year":"2010","journal-title":"Gait Posture"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1177\/107110070502600210","article-title":"Efficacy of Plantar Loading Parameters During Gait in Terms of Reliability, Variability, Effect of Gender and Relationship Between Contact Area and Plantar Pressure","volume":"26","author":"Murphy","year":"2005","journal-title":"Foot Ankle Int."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1016\/j.gaitpost.2007.07.002","article-title":"Between-day reliability of repeated plantar pressure distribution measurements in a normal population","volume":"27","author":"Gurney","year":"2008","journal-title":"Gait Posture"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/j.gaitpost.2010.06.023","article-title":"Normal pressure values and repeatability of the Emed1 ST2 system","volume":"32","author":"Maetzler","year":"2010","journal-title":"Gait Posture"},{"key":"ref_38","unstructured":"Portney, L.G., and Watkins, M.P. (2014). Foundations of Clinical Research: Applications to Practice, Pearson Education Limited."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Cohen, J. (2013). Statistical Power Analysis for the Behavioral Sciences, Routledge.","DOI":"10.4324\/9780203771587"},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Ciniglio, A., Guiotto, A., Spolaor, F., and Sawacha, Z. (2021). The design and simulation of a 16-sensors plantar pressure insole layout for different applications: From sports to clinics, a pilot study. Sensors, 21.","DOI":"10.3390\/s21041450"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.fas.2018.12.005","article-title":"A state-of-the-art review of foot pressure","volume":"26","author":"Zulkifli","year":"2020","journal-title":"Foot Ankle Surg."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.apergo.2015.08.011","article-title":"Validity and reliability of pressure-measurement insoles for vertical ground reaction force assessment in field situations","volume":"53","author":"Koch","year":"2016","journal-title":"Appl. Ergon."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.measurement.2019.03.023","article-title":"Benchmarking study of the forces and centre of pressure derived from a novel smart-insole against an existing pressure measuring insole and force plate","volume":"142","author":"Weizman","year":"2019","journal-title":"Measurement"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1016\/j.dsx.2020.06.041","article-title":"Effectiveness of customized insoles on maximum plantar pressure in diabetic foot syndrome: A systematic review","volume":"14","author":"Korada","year":"2020","journal-title":"Diabetes Metab. Syndr. Clin. Res. Rev."},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Elstub, L., Grohowski, L., Wolf, D., Owen, M., Noehren, B., and Zelik, K. (2022). Effect of pressure insole sampling frequency on insole-measured peak force accuracy during running. J. Biomech., 145.","DOI":"10.1016\/j.jbiomech.2022.111387"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1177\/0363546507309315","article-title":"Regional foot pressure during running, cutting, jumping, and landing","volume":"36","author":"Orendurff","year":"2007","journal-title":"Am. J. Sports Med."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.gaitpost.2016.03.016","article-title":"Plantar pressure measurements and running-related injury: A systematic review of methods and possible associations","volume":"47","author":"Mann","year":"2016","journal-title":"Gait Posture"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Zhang, Z., Dai, Y., Xu, Z., Grimaldi, N., Wang, J., Zhao, M., Pang, R., Sun, Y., Gao, S., and Boyi, H. (2023). Insole Systems for Disease Diagnosis and Rehabilitation: A Review. Biosensors, 13.","DOI":"10.3390\/bios13080833"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Cucuzzella, A.R., and Marley, J. (2007). Rehabilitation Methods. Interventional Spine E-Book: An Algorithmic Approach, Elsevier Health Sciences.","DOI":"10.1016\/B978-0-7216-2872-1.50068-6"},{"key":"ref_50","first-page":"CD004129","article-title":"Force platform feedback for standing balance training after stroke","volume":"2004","author":"Stevenson","year":"2004","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_51","first-page":"756564","article-title":"The Clinical Relevance of Force Platform Measures in Multiple Sclerosis: A Review","volume":"2013","author":"Prosperini","year":"2013","journal-title":"Mult. Scler. Int."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"20392","DOI":"10.3390\/s150820392","article-title":"Identification of foot pathologies based on plantar pressure asymmetry","volume":"15","author":"Wafai","year":"2015","journal-title":"Sensors"}],"container-title":["Applied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2076-3417\/15\/13\/7575\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:05:25Z","timestamp":1760033125000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2076-3417\/15\/13\/7575"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,6]]},"references-count":52,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2025,7]]}},"alternative-id":["app15137575"],"URL":"https:\/\/doi.org\/10.3390\/app15137575","relation":{},"ISSN":["2076-3417"],"issn-type":[{"value":"2076-3417","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,6]]}}}