{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T16:52:11Z","timestamp":1776444731226,"version":"3.51.2"},"reference-count":56,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2023,11,5]],"date-time":"2023-11-05T00:00:00Z","timestamp":1699142400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Buildings"],"abstract":"<jats:p>Ensuring good indoor air quality in the spaces within educational centres is essential for the health and academic performance of students. In this sense, studying the evolution of health pollutants and their relationship with the environmental parameters of indoor humidity and temperature presents a challenge for the design of more efficient and comfortable buildings with a lower risk of virus infection. In this work, the relationship between pollution levels and SARS-CoV-2 virus infections in the academic year 2021\/22 is shown, comparing the pollution values measured on-site with the value of the official measuring stations of the Community of Madrid. In addition, the impact of ventilation measures implemented during this period is assessed, aiming to establish guidelines for ensuring a safer and healthier school environment. It was found that during winter months, when there is less outdoor ventilation, pollution levels exceeded the recommended limits, according to reference regulations. This highlights the need for interior conditioning strategies in educational spaces. Thus, this multidimensional approach, considering both airborne pollutants and weather conditions, provides a comprehensive perspective on indoor air quality in school buildings in the central area of a metropolitan city, such as the Community of Madrid.<\/jats:p>","DOI":"10.3390\/buildings13112780","type":"journal-article","created":{"date-parts":[[2023,11,5]],"date-time":"2023-11-05T07:35:06Z","timestamp":1699169706000},"page":"2780","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Experimental Study of Indoor Air Quality in Educational Buildings: A Spanish Case Study"],"prefix":"10.3390","volume":"13","author":[{"given":"Alberto Leal","family":"Matilla","sequence":"first","affiliation":[{"name":"Departamento de Tecnolog\u00eda de la Edificaci\u00f3n, Universidad Polit\u00e9cnica de Madrid, Avda. Juan de Herrera, 6, 28040 Madrid, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9976-0541","authenticated-orcid":false,"given":"Jorge Pablo Diaz","family":"Velilla","sequence":"additional","affiliation":[{"name":"Departamento de Ingenier\u00eda de Organizaci\u00f3n, Universidad Polit\u00e9cnica de Madrid, Administraci\u00f3n de Em-Presas y Estad\u00edstica, C. de los Ciruelos, 28660 Madrid, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-7799-9740","authenticated-orcid":false,"given":"Alicia","family":"Zaragoza-Benzal","sequence":"additional","affiliation":[{"name":"Departamento de Tecnolog\u00eda de la Edificaci\u00f3n, Universidad Polit\u00e9cnica de Madrid, Avda. Juan de Herrera, 6, 28040 Madrid, Spain"}]},{"given":"Daniel","family":"Ferr\u00e1ndez","sequence":"additional","affiliation":[{"name":"Departamento de Tecnolog\u00eda de la Edificaci\u00f3n, Universidad Polit\u00e9cnica de Madrid, Avda. Juan de Herrera, 6, 28040 Madrid, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0134-6762","authenticated-orcid":false,"given":"Paulo","family":"Santos","sequence":"additional","affiliation":[{"name":"Department of Civil Engineering, University of Coimbra, ISISE, ARISE, Rua Lu\u00eds Reis Santos\u2014P\u00f3lo II, 3030-788 Coimbra, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2023,11,5]]},"reference":[{"key":"ref_1","unstructured":"(2021). Sustainability of Construction Works\u2014Framework for Assessment of Buildings and Civil Engineering Works (Standard No. EN 15643)."},{"key":"ref_2","unstructured":"(2014). Sustainability of Construction Works\u2014Assessment of Social Performance of Buildings\u2014Calculation Methodology (Standard No. EN 16309 + A1)."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1051\/mattech\/2016040","article-title":"Comparative life cycle social assessment of buildings: Health and comfort criterion","volume":"104","author":"Santos","year":"2017","journal-title":"Mat\u00e9riaux Tech."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1016\/j.buildenv.2017.07.014","article-title":"Assessment of health and comfort criteria in a life cycle social context: Application to buildings for higher education","volume":"123","author":"Santos","year":"2017","journal-title":"Build. Environ."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.jeem.2014.11.002","article-title":"Indoor air quality and academic performance","volume":"70","author":"Stafford","year":"2015","journal-title":"J. Environ. Econ. Manag."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"147498","DOI":"10.1016\/j.scitotenv.2021.147498","article-title":"Identifying the K-12 classrooms\u2019 indoor air quality factors that affect student academic performance","volume":"786","author":"Kabirikopaei","year":"2021","journal-title":"Sci. the Total Environ."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1016\/j.enbuild.2004.06.005","article-title":"The effect of perceived indoor air quality on productivity loss","volume":"36","author":"Kosonen","year":"2004","journal-title":"Energy Build."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"106645","DOI":"10.1016\/j.jobe.2023.106645","article-title":"Optimizing indoor air quality and noise levels in old school classrooms with air purifiers and HRV: A CONTAM simulation study","volume":"73","author":"Na","year":"2023","journal-title":"J. Build. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"109717","DOI":"10.1016\/j.buildenv.2022.109717","article-title":"Assessment of indoor air quality and risk of COVID-19 infection in Spanish secondary school and university classrooms","volume":"226","author":"Urbieta","year":"2022","journal-title":"Build. Environ."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"105324","DOI":"10.1016\/j.jobe.2022.105324","article-title":"Improving indoor air quality in primary school buildings through optimized apertures and classroom furniture layouts Author links open overlay panel","volume":"62","author":"Tikul","year":"2022","journal-title":"J. Build. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1603","DOI":"10.1016\/S0140-6736(21)00869-2","article-title":"Ten scientific reasons in support of airborne transmission of SARS-CoV-2","volume":"397","author":"Greenhalgh","year":"2021","journal-title":"Lancet"},{"key":"ref_12","unstructured":"Harvard, C. (2023, February 15). Gu\u00eda en 5 Pasos Para Medir la Tasa de Renovaci\u00f3n en Las Aulas. Available online: https:\/\/alara.es\/guia-para-medir-la-tasa-de-renovacion-de-aire-en-aulas\/."},{"key":"ref_13","unstructured":"Evaluaci\u00f3n del Riesgo de la Transmisi\u00f3n de SARS-CoV- Mediante Aerosoles (2022, November 15). Medidas de Prevenci\u00f3n y Recomendaci\u00f3n. Available online: https:\/\/www.mscbs.gob.es\/profesionales\/saludPublica\/ccayes\/alertasActual\/nCov\/documentos\/COVID19_Aerosoles.pdf."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"101373","DOI":"10.1016\/j.apr.2022.101373","article-title":"A comprehensive analysis of the intervention of a fresh air ventilation system on indoor air quality in classrooms","volume":"13","author":"Chen","year":"2022","journal-title":"Atmos. Pollut. Res."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"3150","DOI":"10.1016\/j.egypro.2015.11.772","article-title":"Air Permeability of Naturally Ventilated Italian Classrooms","volume":"78","author":"Stabile","year":"2015","journal-title":"Energy Procedia"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.egypro.2016.11.033","article-title":"Natural Ventilation Level Assessment in a School Building by CO2 Concentration Measures","volume":"1101","author":"Schibuola","year":"2016","journal-title":"Energy Procedia"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Bogdanovica, S., Zemitis, J., and Bogdanovics, R. (2020). The Effect of CO2 Concentration on Children\u2019s Well-Being during the Process of Learning. Energies, 13.","DOI":"10.3390\/en13226099"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.envint.2018.08.059","article-title":"Effects of low-level inhalation exposure to carbon dioxide in indoor environments: A short review on human health and psychomotor performance","volume":"121","author":"Azuma","year":"2018","journal-title":"Environ. Int."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"103140","DOI":"10.1016\/j.jobe.2021.103140","article-title":"Development of an assessment methodology for IAQ ventilation performance in residential buildings: An investigation of relevant performance indicators","volume":"43","author":"Poirier","year":"2021","journal-title":"J. Build. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.buildenv.2015.03.018","article-title":"Association of carbon dioxide with indoor air pollutants and exceedance of health guideline values","volume":"93","author":"Ramalho","year":"2015","journal-title":"Build. Environ."},{"key":"ref_21","unstructured":"World Health Organization (2023, March 15). Calidad del Aire Ambiente (Exterior) y Salud. Available online: https:\/\/www.who.int\/es\/news-room\/fact-sheets\/detail\/ambient-(outdoor)-air-quality-and-health."},{"key":"ref_22","unstructured":"(2023, February 15). Air Quality in Europe\u20142020 Report. European Environment Agency. Available online: https:\/\/www.eea.europa.eu\/publications\/air-quality-in-europe-2020-report."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.atmosenv.2015.01.055","article-title":"Outdoor infiltration and indoor contribution of UFP and BC, OC, secondary inorganic ions and metals in PM2.5 in schools","volume":"196","author":"Rivas","year":"2015","journal-title":"Atmos. Environ."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"103065","DOI":"10.1016\/j.tust.2019.103065","article-title":"The potential influence of building optimization and passive design strategies on natural ventilation systems in underground buildings: The state of the art","volume":"92","author":"Mukhtar","year":"2019","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_25","first-page":"39","article-title":"Formaldehyde, 2-Butoxyethanol and 1-tert-Butoxypropan-2-ol","volume":"88","author":"IARC","year":"2006","journal-title":"IARC Monogr. Eval. Carcinog. Risks Hum."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1007\/s11869-019-00715-7","article-title":"Indoor air pollution with benzene, formaldehyde, and nitrogen dioxide in schools in Osijek, Croatia","volume":"12","author":"Lutz","year":"2019","journal-title":"Air Qual. Atmos. Health"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1111\/ina.12657","article-title":"Association between indoor formaldehyde exposure and asthma: A systematic review and meta-analysis of observational studies","volume":"30","author":"Yu","year":"2020","journal-title":"Indoor Air"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"689","DOI":"10.3155\/1047-3289.61.6.689","article-title":"Effect of Temperature and Humidity on Formaldehyde Emissions in Temporary Housing Units","volume":"61","author":"Parthasarathy","year":"2011","journal-title":"J. Air Waste Manag. Assoc."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1038\/s41598-019-57263-4","article-title":"Indoor air formaldehyde (HCHO) pollution of urban coach cabins","volume":"10","author":"Qin","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"152271","DOI":"10.1016\/j.scitotenv.2021.152271","article-title":"Diurnal variation and potential sources of indoor formaldehyde at elementary school, high school and university in the Centre Val de Loire region of France","volume":"811","author":"Hu","year":"2022","journal-title":"Sci. Total Environ."},{"key":"ref_31","unstructured":"(2022, November 15). Madrid: Poblaci\u00f3n Por Municipios y Sexo. Available online: https:\/\/www.ine.es\/jaxiT3\/Datos.htm?t=2881."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"e121","DOI":"10.1016\/S2542-5196(20)30272-2","article-title":"Premature mortality due to air pollution in European cities: A health impact assessment","volume":"5","author":"Khomenko","year":"2021","journal-title":"Lancet Planet. Health"},{"key":"ref_33","unstructured":"(2023, September 01). Real Decreto 314\/2006; Ministerio de Vivienda: C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n (in Spanish). Madrid, Spain. Available online: https:\/\/www.codigotecnico.org\/pdf\/Documentos\/HE\/DccHE.pdf."},{"key":"ref_34","unstructured":"(2023, September 01). Real Decreto 238\/2013; Ministerio de Industria, Energ\u00eda y Turismo: Reglamento de Instalaciones T\u00e9rmicas en los Edificios (RITE) (in Spanish). Madrid, Spain. Available online: https:\/\/www.boe.es\/buscar\/doc.php?id=BOE-A-2013-3905."},{"key":"ref_35","unstructured":"European Environment Agency (2019). EMEP\/EEA Air Pollutant Emission Inventory Guidebook."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"101713","DOI":"10.1016\/j.scs.2019.101713","article-title":"Experimental comparative study of the thermal performance of the fa\u00e7ade of a building refurbished using ETICS, and quantification of improvements","volume":"51","author":"Aguilera","year":"2019","journal-title":"Sustain. Cities Society"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"109925","DOI":"10.1016\/j.buildenv.2022.109925","article-title":"Association of indoor temperature and air quality in classrooms based on field and intervention measurements","volume":"229","author":"Zhang","year":"2023","journal-title":"Build. Environ."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"101473","DOI":"10.1016\/j.uclim.2023.101473","article-title":"Application of land-use regression model with regularization algorithm to assess PM2.5 and PM10 concentration and health risk in Kolkata Metropolitan","volume":"49","author":"Das","year":"2023","journal-title":"Urban Clim."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"119515","DOI":"10.1016\/j.atmosenv.2022.119515","article-title":"Small contributions of dust to PM2.5 and PM10 concentrations measured downwind of Oceano Dunes","volume":"294","author":"Lewis","year":"2023","journal-title":"Atmos. Environ."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"e14648","DOI":"10.1016\/j.heliyon.2023.e14648","article-title":"The impact of mortality underreporting on the association of ambient temperature and PM10 with mortality risk in time series study","volume":"9","author":"Lin","year":"2023","journal-title":"Heliyon"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"106124","DOI":"10.1016\/j.envint.2020.106124","article-title":"A novel model for regional indoor PM2.5 quantification with both external and internal contributions included","volume":"145","author":"Lu","year":"2020","journal-title":"Environ. Int."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"108792","DOI":"10.1016\/j.buildenv.2022.108792","article-title":"Impact of air distribution on indoor formaldehyde abatement with\/without passive removal material: A CFD modeling","volume":"212","author":"Malayeri","year":"2022","journal-title":"Build. Environ."},{"key":"ref_43","unstructured":"INSHT (2001). NTP 590: Prevenci\u00f3n de la Exposici\u00f3n a Formaldeh\u00eddo, Ministerio de Trabajo y Asuntos Sociales."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.jhin.2023.01.021","article-title":"Recognition of hand disinfection by an alcohol-containing gel using two-dimensional imaging in a clinical setting","volume":"135","author":"Figueroa","year":"2023","journal-title":"J. Hosp. Infect."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1016\/j.jsps.2021.06.002","article-title":"Preparation and evaluation of benzalkonium chloride hand sanitizer as a potential alternative for alcohol-based hand gels","volume":"29","author":"Aodah","year":"2021","journal-title":"Saudi Pharm. J."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"110247","DOI":"10.1016\/j.enbuild.2020.110247","article-title":"Energy renovation of multi apartment buildings: Contributions to economy and climate changes","volume":"224","author":"Buturac","year":"2020","journal-title":"Energy Build."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"113295","DOI":"10.1016\/j.rser.2023.113295","article-title":"Sustainability of building-integrated bioclimatic design strategies depending on energy affordability","volume":"179","author":"Elaouzy","year":"2023","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"133219","DOI":"10.1016\/j.conbuildmat.2023.133219","article-title":"Study of the hygroscopic properties of environmentally friendly lightened composites through waste recovery","volume":"404","year":"2023","journal-title":"Constr. Build. Mater."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"113389","DOI":"10.1016\/j.enbuild.2023.113389","article-title":"Impact of ambient air temperature, orientation, and plant status on the thermal performance of green fa\u00e7ades","volume":"296","author":"Bakhshoodeh","year":"2023","journal-title":"Energy Build."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"103196","DOI":"10.1016\/j.cities.2021.103196","article-title":"Perceptions on barriers and opportunities for integrating urban agri-green roofs: A European Mediterranean compact city case","volume":"114","author":"Parada","year":"2021","journal-title":"Cities"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.scs.2014.10.003","article-title":"Experimental investigation of the thermal isolation and evaporative cooling effects of an exposed shallow-water-reserved roof under the sub-tropical climatic condition","volume":"14","author":"Yang","year":"2015","journal-title":"Sustain. Cities Soc."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.esd.2022.09.020","article-title":"Contribution of green roofs to energy savings in building renovations","volume":"71","author":"Lerma","year":"2022","journal-title":"Energy Sustain. Dev."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"113233","DOI":"10.1016\/j.enbuild.2023.113233","article-title":"Building integrated vegetation effect on micro-climate conditions for urban heat island adaptation. Lesson learned from Turin and Rome case studies","volume":"295","author":"Susca","year":"2023","journal-title":"Energy Build."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"113044","DOI":"10.1016\/j.enbuild.2023.113044","article-title":"Influence of outdoor air pollution on European residential ventilative cooling potential","volume":"289","author":"Belias","year":"2023","journal-title":"Energy Build."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"113587","DOI":"10.1016\/j.rser.2023.113587","article-title":"Extreme climate change hazards and impacts on European coastal cities: A review","volume":"184","author":"Laino","year":"2023","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"101918","DOI":"10.1016\/j.jobe.2020.101918","article-title":"The nZEB concept and its requirements for residential buildings renovation in Southern Europe: The case of multi-family buildings from 1961 to 1980 in Portugal and Spain","volume":"34","author":"Resende","year":"2021","journal-title":"J. Build. Eng."}],"container-title":["Buildings"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-5309\/13\/11\/2780\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:17:51Z","timestamp":1760131071000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-5309\/13\/11\/2780"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,5]]},"references-count":56,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2023,11]]}},"alternative-id":["buildings13112780"],"URL":"https:\/\/doi.org\/10.3390\/buildings13112780","relation":{},"ISSN":["2075-5309"],"issn-type":[{"value":"2075-5309","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,5]]}}}