{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T09:07:18Z","timestamp":1794647238482,"version":"4.9.1"},"reference-count":48,"publisher":"MDPI AG","issue":"24","license":[{"start":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T00:00:00Z","timestamp":1734307200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005908","name":"Federal Ministry of Food and Agriculture","doi-asserted-by":"publisher","award":["313-06.01-28-1-57.071-15"],"award-info":[{"award-number":["313-06.01-28-1-57.071-15"]}],"id":[{"id":"10.13039\/501100005908","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005908","name":"Federal Ministry of Food and Agriculture","doi-asserted-by":"publisher","award":["313-06.01-28-1-DP.01E-20"],"award-info":[{"award-number":["313-06.01-28-1-DP.01E-20"]}],"id":[{"id":"10.13039\/501100005908","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005908","name":"Federal Ministry of Food and Agriculture","doi-asserted-by":"publisher","award":["313-06.01-28-1-89.09A-20"],"award-info":[{"award-number":["313-06.01-28-1-89.09A-20"]}],"id":[{"id":"10.13039\/501100005908","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Electronics"],"abstract":"<jats:p>The use of ion-selective field-effect transistors (ISFETs) facilitates real-time nutrient analysis in agricultural applications, including soil analysis and hydroponics. The rapid digital availability of analysis results allows for the implementation of ion-specific fertilisation control. The success, accuracy, and robustness of measurements using ISFET technology strongly depend on the handling of the process. This article presents a detailed overview of the sub-process steps required for the implementation of a stable automated application-specific ISFET-based measurement. This article provides experience-based recommendations for handling the conditioning, full calibration, and single-point calibration of the ISFET sensors. The hypotheses were empirically tested under authentic conditions and subsequently integrated into an overall process optimisation strategy. A comprehensive investigation has been conducted with the objective of gaining a deeper understanding of the ISFET baseline drift and implementing corrective measures. The results show that the baseline drift can be quantified and taken into account in the evaluation of the ISFET measurements. The efficacy of these measures was validated using standard laboratory analyses.<\/jats:p>","DOI":"10.3390\/electronics13244958","type":"journal-article","created":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T10:08:53Z","timestamp":1734343733000},"page":"4958","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Handling of Ion-Selective Field-Effect Transistors (ISFETs) on Automatic Measurements in Agricultural Applications Under Real-Field Conditions"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-8377-4959","authenticated-orcid":false,"given":"Vadim","family":"Riedel","sequence":"first","affiliation":[{"name":"Faculty of Engineering and Computer Science, University of Applied Sciences Osnabr\u00fcck, 49076 Osnabr\u00fcck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4353-2168","authenticated-orcid":false,"given":"Stefan","family":"Hinck","sequence":"additional","affiliation":[{"name":"Faculty of Engineering and Computer Science, University of Applied Sciences Osnabr\u00fcck, 49076 Osnabr\u00fcck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edgar","family":"Peiter","sequence":"additional","affiliation":[{"name":"Faculty of Agricultural and Nutritional Sciences, Geosciences and Computer Science, Martin-Luther-University Halle-Wittenberg, 06112 Halle, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arno","family":"Ruckelshausen","sequence":"additional","affiliation":[{"name":"Faculty of Engineering and Computer Science, University of Applied Sciences Osnabr\u00fcck, 49076 Osnabr\u00fcck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,12,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e2100207","DOI":"10.1002\/elsa.202100207","article-title":"ISFET-based sensors for (bio)chemical applications: A review","volume":"3","author":"Cao","year":"2023","journal-title":"Electrochem. Sci. Adv."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Moser, N., Keeble, L., Rodriguez-Manzano, J., and Georgiou, P. (2019, January 27\u201329). ISFET arrays for lab-on-chip technology: A review. Proceedings of the 2019 IEEE 26th International Conference on Electronics, Circuits and Systems (ICECS), Genoa, Italy.","DOI":"10.1109\/ICECS46596.2019.8965034"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Keller, R.B. (2023). EMC Design Guidelines. Design for Electromagnetic Compatibility-in a Nutshell, Springer.","DOI":"10.1007\/978-3-031-14186-7"},{"key":"ref_4","unstructured":"Riedel, V., Najdenko, E., M\u00f6ller, A., Terhaag, M., Mentrup, D., Kerssen, H., Lorenz, F., Mosler, T., Tesch, H., and Peters, W. (2022, January 9). Prototypes4soil2data: Modular designed mobile field laboratory for standardized soil nutrient analysis directly on the field. Proceedings of the XX CIGR World Congress, Kyoto, Japan."},{"key":"ref_5","unstructured":"Hinck, S., M\u00f6ller, A., Terhaag, M., Meyer, T., Mentrup, D., Kerssen, H., Najdenko, E., Lorenz, F., Mosler, T., and Tesch, H. (August, January 31). Analyse-to-go on the field: Prototypes4soil2data. Proceedings of the 22nd World Congress of Soil Science in Glasgow, Glasgow, UK."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"13349","DOI":"10.3390\/s121013349","article-title":"Ion-specific nutrient management in closed systems: The necessity for ion-selective sensors in terrestrial and space-based agriculture and water management systems","volume":"12","author":"Bamsey","year":"2012","journal-title":"Sensors"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/S0925-4005(04)00113-3","article-title":"ISE and Chemfet sensors in greenhouse cultivation","volume":"105","author":"Gieling","year":"2005","journal-title":"Sens. Actuators B Chem."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Riedel, V., Hinck, S., Peiter, E., and Ruckelshausen, A. (2024). Concept and Realisation of ISFET-Based Measurement Modules for Infield Soil Nutrient Analysis and Hydroponic Systems. Electronics, 13.","DOI":"10.3390\/electronics13132449"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"107828","DOI":"10.1016\/j.compag.2023.107828","article-title":"Towards the implementation of ISFET sensors for in-situ and real-time chemical analyses in soils: A practical review","volume":"209","author":"Archbold","year":"2023","journal-title":"Comput. Electron. Agric."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1002\/jpln.202300166","article-title":"Development of an express method for measuring soil nitrate, phosphate, potassium, and pH for future in-field application","volume":"186","author":"Najdenko","year":"2023","journal-title":"J. Plant Nutr. Soil Sci."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"206","DOI":"10.12912\/27197050\/191781","article-title":"Evaluation of Soil Potassium Using Miniaturized Electrochemical Sensors","volume":"25","author":"Benslimane","year":"2024","journal-title":"Ecol. Eng. Environ. Technol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1038\/d41586-023-03316-8","article-title":"Garbage in, garbage out: Mitigating risks and maximizing benefits of AI in research","volume":"623","author":"Hanson","year":"2023","journal-title":"Nature"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1007\/s10008-011-1456-y","article-title":"Polymeric membranes conditioning for sensors applications: Mechanism and influence on analytes detection","volume":"16","author":"Giamblanco","year":"2012","journal-title":"J. Solid State Electrochem."},{"key":"ref_14","first-page":"1987","article-title":"Ion-selective electrode potentiometry in environmental analysis","volume":"19","author":"Clarke","year":"2007","journal-title":"Electroanal. Int. J. Devoted Fundam. Pract. Asp. Electroanal."},{"key":"ref_15","unstructured":"Marstalerz, J. (2003). Einflu\u00df der Polymermatrix auf Eigenschaften Membranbedeckter Potentiometrischer Mikrosensoren (Influence of the Polymer Matrix on the Properties of Membrane-Covered Potentiometric Micro-Sensors). [Doctoral Dissertation, University of Halle (Saale)]."},{"key":"ref_16","first-page":"83","article-title":"Deposition volume and conditioning time for good Nernstian response from a novel PVCbased Mn (TPP) Cl membrane for histamine sensitive FET","volume":"9","author":"Lee","year":"2015","journal-title":"Int. J. Biol. Biomed. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.aca.2010.08.035","article-title":"Recent trends in potentiometric sensor arrays\u2014A review","volume":"678","author":"Bratov","year":"2010","journal-title":"Anal. Chim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/S0003-2670(97)00396-6","article-title":"Simultaneous determination of mixtures of metal ions by complexometric titration and multivariate calibration","volume":"354","author":"Ni","year":"1997","journal-title":"Anal. Chim. Acta"},{"key":"ref_19","unstructured":"Esbensen, K.H., Guyot, D., Westad, F., and Houmoller, L.P. (2002). Multivariate Data Analysis\u2014In Practise: An Introduction to Multivariate Data Analysis and Experimental Design, CAMO. [5th ed.]."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/j.talanta.2008.04.013","article-title":"Autocalibration technique based on SIA and integrated multisensor chip","volume":"72","author":"Ipatov","year":"2008","journal-title":"Talanta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"131123","DOI":"10.1016\/j.snb.2021.131123","article-title":"Cross-compensation of FET sensor drift and matrix effects in the industrial continuous monitoring of ion concentrations","volume":"353","author":"Liu","year":"2022","journal-title":"Sens. Actuators B Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1049\/el:20071118","article-title":"Drift reduction in ion-sensitive FETs using correlated double sampling","volume":"43","author":"Premanode","year":"2007","journal-title":"Electron. Lett."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Yanagawa, Y., Itabashi, N., Migitaka, S., Yokoi, T., Yoshida, M., and Kawahara, T. (November, January 31). On-chip base sequencing using a two-stage reaction-control scheme: 3.6-times-faster and 1\/100-reduced-data-volume ISFET-based DNA sequencer. Proceedings of the 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS), Rotterdam, The Netherlands.","DOI":"10.1109\/BioCAS.2013.6679668"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1038\/nmeth.2520","article-title":"Simultaneous DNA amplification and detection using a pH-sensing semiconductor system","volume":"10","author":"Toumazou","year":"2013","journal-title":"Nat. Methods"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1016\/S0925-4005(01)00639-6","article-title":"A novel pH sensitive ISFET with on chip temperature sensing using CMOS standard process","volume":"76","author":"Chin","year":"2001","journal-title":"Sens. Actuators B Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.sna.2016.09.004","article-title":"Thermal compensation technique using the parasitic diode for DMOS transistors","volume":"249","author":"Carvajal","year":"2016","journal-title":"Sens. Actuators A Phys."},{"key":"ref_27","unstructured":"(2024, October 23). Technical Note pH-ISFET, Fraunhofer Institute for Photonic Microsystems IPMS. Available online: https:\/\/www.ipms.fraunhofer.de\/content\/dam\/ipms\/common\/documents\/2024\/ofet\/isfet\/FraunhoferIPMS\u2014Ion-sensitivefield-effecttransistors(ISFET).pdf."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Shah, S., and Christen, J.B. (2013, January 3\u20136). Pulse width modulation circuit for ISFET drift reset. Proceedings of the IEEE SENSORS, Baltimore, MD, USA.","DOI":"10.1109\/ICSENS.2013.6688269"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Sohbati, M., and Toumazou, C. (2014, January 1\u20135). A temperature insensitive continuous time \u0394pH to digital converter. Proceedings of the IEEE International Symposium on Circuits and Systems (ISCAS), Melbourne, VIC, Australia.","DOI":"10.1109\/ISCAS.2014.6865059"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.snb.2004.03.004","article-title":"The development of scalable sensor arrays using standard CMOS technology","volume":"103","author":"Milgrew","year":"2004","journal-title":"Sens. Actuators B Chem."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.snb.2018.02.068","article-title":"Ion sensitive AlGaN\/GaN field-effect transistors with monolithically integrated wheatstone bridge for temperature-and drift compensation in enzymatic biosensors","volume":"263","author":"Stock","year":"2018","journal-title":"Sens. Actuators B Chem."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1109\/JSEN.2004.833148","article-title":"An analytical technique for counteracting drift in ion-selective field effect transistors (ISFETs)","volume":"4","author":"Jamasb","year":"2004","journal-title":"IEEE Sens. J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1948","DOI":"10.1109\/JSEN.2008.2006471","article-title":"An intelligent ISFET sensory system with temperature and drift compensation for long-term monitoring","volume":"8","author":"Chen","year":"2008","journal-title":"IEEE Sens. J."},{"key":"ref_34","unstructured":"(2021). Technical Note: NUTRISTAT Specifications from Company Microsens SA, unpublished."},{"key":"ref_35","unstructured":"Koppenhoefer, D. (2016). Transistor-Transfer Function Measurements Using Ionsensitive Field-Effect Transistors to Analyze Cell Viability as a Novel Tool for Pharmacological High Throughput Screening. [Ph.D. Thesis, University of Saarland]. Available online: https:\/\/scidok.sulb.uni-saarland.de\/bitstream\/20.500.11880\/27064\/1\/Transistor-Transferfunktionsmessungen.pdf."},{"key":"ref_36","unstructured":"(2024, December 10). Microsens SA\u2014Products. Available online: http:\/\/microsens.ch\/products\/chemical.htm."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.1016\/j.proeng.2014.11.713","article-title":"Miniature multisensor probe for soil nutrient monitoring","volume":"87","author":"Lehmann","year":"2014","journal-title":"Procedia Eng."},{"key":"ref_38","unstructured":"Riedel, V. (2024, December 10). ISFET Sensors Measurement Data for Soil Nutrient Analysis. 2024. Available online: https:\/\/doi.org\/10.25625\/UTIMMI."},{"key":"ref_39","unstructured":"VDLUFA (2016). Handbuch der Landwirtschaftlichen Versuchs- und Untersuchungsmethodik (VDLUFA-Methodenbuch). Vol. I, Die Untersuchung von B\u00f6den. (Handbook of Agricultural Research- and Testing Methods, Vol. I, The Testing of Soils), VDLUFA, Verband Deutscher Landwirtschaftlicher Untersuchungs- und Forschungsanstalten (German Association of Agricultural Analysis and Research Institutes)."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/S0169-7439(98)00094-X","article-title":"Simultaneous polarographic chemometric determination of lead, copper, vanadium, cadmium and nickel","volume":"45","author":"Ni","year":"1999","journal-title":"Chemom. Intell. Lab. Sys."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/0003-2670(94)00500-L","article-title":"Indirect voltammetric determination of carbaryl and carbofuran using partial least squares calibration","volume":"305","author":"Guiberteau","year":"1995","journal-title":"Anal. Chim. Acta"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1533","DOI":"10.1002\/1521-4109(200211)14:22<1533::AID-ELAN1533>3.0.CO;2-T","article-title":"Multivariate data analysis in electroanalytical chemistry","volume":"14","author":"Richards","year":"2002","journal-title":"Electroanalysis"},{"key":"ref_43","first-page":"2456-124X","article-title":"Principle and applications of ion selective electrodes-an overview","volume":"2","author":"Naik","year":"2016","journal-title":"Int. J. Appl. Res. Sci. Eng."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/S0003-2670(01)95680-6","article-title":"Selectivity of ion-specific membrane electrodes","volume":"47","author":"Pungor","year":"1969","journal-title":"Anal. Chim. Acta"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1351\/pac200072101851","article-title":"Potentiometric selectivity coefficients of ion-selective electrodes","volume":"72","author":"Umezawa","year":"2000","journal-title":"Pure Appl. Chem."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1016\/S0026-2714(99)00285-1","article-title":"pH, pK and pNa detection properties of SiO2\/Si3N4 ISFET chemical sensors","volume":"40","author":"Hajji","year":"2000","journal-title":"Microelectron. Reliab."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.1021\/cr970113+","article-title":"Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors","volume":"98","author":"Pretsch","year":"1998","journal-title":"Chem. Rev."},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Tsukor, V., Hinck, S., Nietfeld, W., Mosler, T., Tesch, H., Lorenz, F., Najdenko, E., M\u00f6ller, A., Mentrup, D., and Ruckelshausen, A. (2024, October 23). Automated mobile field laboratory for on-the-go soil-nutrient analysis with the ISFET multi-sensor module. In Proceedings 77th International Conference on Agricultural Engineering (AgEng 2019), Hannover, Germany, 8\u20139 November 2019. Available online: https:\/\/elibrary.vdi-verlag.de\/10.51202\/9783181023617-377\/automated-mobile-field-laboratory-for-on-the-go-soilnutrient-analysis-with-the-isfet-multi-sensor-module?page=1.","DOI":"10.51202\/9783181023617-377"}],"container-title":["Electronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-9292\/13\/24\/4958\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:53:16Z","timestamp":1760115196000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-9292\/13\/24\/4958"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,16]]},"references-count":48,"journal-issue":{"issue":"24","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["electronics13244958"],"URL":"https:\/\/doi.org\/10.3390\/electronics13244958","relation":{},"ISSN":["2079-9292"],"issn-type":[{"value":"2079-9292","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,16]]}}}