{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T20:05:41Z","timestamp":1778529941074,"version":"3.51.4"},"reference-count":42,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2021,3,3]],"date-time":"2021-03-03T00:00:00Z","timestamp":1614729600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["PhD Grants FCT PD\/BD\/150576\/2020 and PD\/BD\/127848\/2016"],"award-info":[{"award-number":["PhD Grants FCT PD\/BD\/150576\/2020 and PD\/BD\/127848\/2016"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Energies"],"abstract":"<jats:p>The global increase in energy needs and environmental awareness for a more efficient energy use have boosted building rehabilitation to decrease energy consumption. The installation of solar control films (SCFs) in buildings with large glazing fa\u00e7ades makes it possible to reduce excessive solar gains through the glazing. The main purpose of the work is to assess, with field experimental data, the thermal and luminous performances of double-glazing units with SCFs installed in office rooms, in Lisbon. An experimental campaign was carried out simultaneously in three adjacent offices: one with a highly reflective SCF (external installation), one with a reflective SCF (internal installation) and one without an SCF. The exterior SCF showed the best thermal performance with reductions in the peak indoor air temperature of up to 6.9 and 2.3 \u00b0C during the representative days of the heating and cooling periods, respectively, increasing thermal comfort mainly during the cooling period. The interior SCF had a poorer thermal performance since it contributed to solar radiation absorption that is then emitted as heat into the indoor environment, increasing the greenhouse effect of the office. The presence of SCFs reduced the indoor illuminance levels, having a positive impact on thermal comfort and glare reduction in the cooling period.<\/jats:p>","DOI":"10.3390\/en14051388","type":"journal-article","created":{"date-parts":[[2021,3,3]],"date-time":"2021-03-03T20:33:57Z","timestamp":1614803637000},"page":"1388","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["In-Service Thermal and Luminous Performance Monitoring of a Refurbished Building with Solar Control Films on the Glazing System"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3391-1495","authenticated-orcid":false,"given":"Henriqueta","family":"Teixeira","sequence":"first","affiliation":[{"name":"Civil Engineering Research and Innovation for Sustainability (CERIS), Department of Civil Engineering, Architecture and Georresources (DECivil), Instituto Superior T\u00e9cnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1499-1370","authenticated-orcid":false,"given":"Maria da Gl\u00f3ria","family":"Gomes","sequence":"additional","affiliation":[{"name":"Civil Engineering Research and Innovation for Sustainability (CERIS), Department of Civil Engineering, Architecture and Georresources (DECivil), Instituto Superior T\u00e9cnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal"}]},{"given":"Ant\u00f3nio","family":"Moret Rodrigues","sequence":"additional","affiliation":[{"name":"Civil Engineering Research and Innovation for Sustainability (CERIS), Department of Civil Engineering, Architecture and Georresources (DECivil), Instituto Superior T\u00e9cnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4539-8844","authenticated-orcid":false,"given":"J\u00falia","family":"Pereira","sequence":"additional","affiliation":[{"name":"Civil Engineering Research and Innovation for Sustainability (CERIS), Department of Civil Engineering, Architecture and Georresources (DECivil), Instituto Superior T\u00e9cnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2021,3,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Calama-Gonz\u00e1lez, C.M., Su\u00e1rez, R., and Le\u00f3n-Rodr\u00edguez, \u00c1.L. (2018). Thermal and Lighting Consumption Savings in Classrooms Retrofitted with Shading Devices in a Hot Climate. Energies, 11.","DOI":"10.3390\/en11102790"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Krsti\u0107-Furund\u017ei\u0107, A., Vujo\u0161evi\u0107, M., and Petrovski, A. (2019). Energy and Environmental Performance of the Office Building Facade Scenarios. Energy.","DOI":"10.1016\/j.energy.2019.05.231"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Prieto, A., Knaack, U., Auer, T., and Klein, T. (2018). Passive Cooling & Climate Responsive Fa\u00e7ade Design Exploring the Limits of Passive Cooling Strategies to Improve the Performance of Commercial Buildings in Warm Climates. Energy Build.","DOI":"10.1016\/j.enbuild.2018.06.016"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Li, J., Ban, Q., Chen, X., and Yao, J. (2019). Glazing Sizing in Large Atrium Buildings: A Perspective of Balancing Daylight Quantity and Visual Comfort. Energies, 12.","DOI":"10.3390\/en12040701"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Detsi, M., Manolitsis, A., Atsonios, I., Mandilaras, I., and Founti, M. (2020). Energy Savings in an Office Building with High WWR Using Glazing Systems Combining Thermochromic and Electrochromic Layers. Energies, 13.","DOI":"10.3390\/en13113020"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Troup, L., Phillips, R., Eckelman, M.J., and Fannon, D. (2019). Effect of Window-to-Wall Ratio on Measured Energy Consumption in US Office Buildings. Energy Build.","DOI":"10.1016\/j.enbuild.2019.109434"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Chiesa, G., Acquaviva, A., Grosso, M., Bottaccioli, L., Floridia, M., Pristeri, E., and Sanna, E.M. (2019). Parametric Optimization of Window-to-Wall Ratio for Passive Buildings Adopting a Scripting Methodology to Dynamic-Energy Simulation. Sustainability, 11.","DOI":"10.3390\/su11113078"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/j.egypro.2018.08.084","article-title":"The Effect of Glazing on NZEB Performance","volume":"148","author":"Murano","year":"2018","journal-title":"Energy Procedia"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Moret Rodrigues, A., Santos, M., Gomes, M.G., and Duarte, R. (2019). Impact of Natural Ventilation on the Thermal and Energy Performance of Buildings in a Mediterranean Climate. Buildings, 9.","DOI":"10.3390\/buildings9050123"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Gomes, M.G., Rodrigues, A.M., and Bogas, J.A. (2012). Numerical and Experimental Study of the Optical Properties of Venetian Blinds. J. Build. Phys.","DOI":"10.1177\/1744259112444022"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.buildenv.2013.09.003","article-title":"Solar and Visible Optical Properties of Glazing Systems with Venetian Blinds: Numerical, Experimental and Blind Control Study","volume":"71","author":"Gomes","year":"2014","journal-title":"Build. Environ."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Sghiouri, H., Mezrhab, A., Karkri, M., and Naji, H. (2018). Shading Devices Optimization to Enhance Thermal Comfort and Energy Performance of a Residential Building in Morocco. J. Build. Eng.","DOI":"10.1016\/j.jobe.2018.03.018"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Kunwar, N., Cetin, K.S., Passe, U., Zhou, X., and Li, Y. (2020). Energy Savings and Daylighting Evaluation of Dynamic Venetian Blinds and Lighting through Full-Scale Experimental Testing. Energy.","DOI":"10.1016\/j.energy.2020.117190"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Fedorczak-Cisak, M., Nowak, K., and Furtak, M. (2019). Analysis of the Effect of Using External Venetian Blinds on the Thermal Comfort of Users of Highly Glazed Office Rooms in a Transition Season of Temperate Climate-Case Study. Energies, 13.","DOI":"10.3390\/en13010081"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Atzeri, A.M., Gasparella, A., Cappelletti, F., and Tzempelikos, A. (2018). Comfort and Energy Performance Analysis of Different Glazing Systems Coupled with Three Shading Control Strategies. Sci. Technol. Built Environ.","DOI":"10.1080\/23744731.2018.1449517"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1016\/j.renene.2003.10.006","article-title":"Lighting and Energy Performance of Solar Film Coating in Air-Conditioned Cellular Offices","volume":"29","author":"Li","year":"2004","journal-title":"Renew. Energy"},{"key":"ref_17","unstructured":"Chen, Y., Hou, G., Xie, H., and Chan, W. (2007, January 28\u201331). In-Site Experimental Measurement of Energy-Saving Performance for Solar-Control Film on Single Window Glass. Proceedings of the Sixth International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings: Sustainable Built Environment, Sendai, Japan."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Calama-Gonz\u00e1lez, C.M., Le\u00f3n-Rodr\u00edguez, \u00c1.L., and Su\u00e1rez, R. (2019). Daylighting Performance of Solar Control Films for Hospital Buildings in a Mediterranean Climate. Energies, 12.","DOI":"10.3390\/en12030489"},{"key":"ref_19","first-page":"65","article-title":"Small-Scale Field Study of Window Films\u2019 Impact on Daylight Availability under Clear Sky Conditions","volume":"8","author":"Pereira","year":"2020","journal-title":"J. Facade Des. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/j.enbuild.2010.11.015","article-title":"Thermal Analysis for a Double Glazing Unit with and without a Solar Control Film (SnS-CuxS) for Using in Hot Climates","volume":"43","author":"Arce","year":"2011","journal-title":"Energy Build."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/j.enbuild.2014.03.015","article-title":"Thermal Analysis for a Double Pane Window with a Solar Control Film for Using in Cold and Warm Climates","volume":"76","author":"Arce","year":"2014","journal-title":"Energy Build."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Xam\u00e1n, J., Olazo-G\u00f3mez, Y., Zavala-Guill\u00e9n, I., Hern\u00e1ndez-P\u00e9rez, I., Aguilar, J.O., and Hinojosa, J.F. (2017). Thermal Evaluation of a Room Coupled with a Double Glazing Window with\/without a Solar Control Film for Mexico. Appl. Therm. Eng.","DOI":"10.1016\/j.applthermaleng.2016.08.156"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.enbuild.2011.10.062","article-title":"Case Study: Energy Savings from Solar Window Film in Two Commercial Buildings in Shanghai","volume":"45","author":"Yin","year":"2012","journal-title":"Energy Build."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Chaiyapinunt, S., Phueakphongsuriya, B., Mongkornsaksit, K., and Khomporn, N. (2005). Performance Rating of Glass Windows and Glass Windows with Films in Aspect of Thermal Comfort and Heat Transmission. Energy Build.","DOI":"10.1016\/j.enbuild.2004.10.008"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Amirkhani, S., Bahadori-Jahromi, A., Mylona, A., Godfrey, P., and Cook, D. (2019). Impact of Low-E Window Films on Energy Consumption and CO2 Emissions of an Existing UK Hotel Building. Sustainability, 11.","DOI":"10.3390\/su11164265"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.1016\/j.energy.2008.03.002","article-title":"Lighting and Cooling Energy Consumption in an Open-Plan Office Using Solar Film Coating","volume":"33","author":"Li","year":"2008","journal-title":"Energy"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.enbuild.2015.04.025","article-title":"Experimental and Theoretical Study on the Effect of Window Films on Building Energy Consumption","volume":"102","author":"Li","year":"2015","journal-title":"Energy Build."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.buildenv.2015.07.031","article-title":"Evaluation of Energy, Thermal, and Daylighting Performance of Solar Control Films for a Case Study in Moderate Climate","volume":"94","author":"Moretti","year":"2015","journal-title":"Build. Environ."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.enbuild.2019.06.003","article-title":"Thermal, Luminous and Energy Performance of Solar Control Films in Single-Glazed Windows: Use of Energy Performance Criteria to Support Decision Making","volume":"198","author":"Pereira","year":"2019","journal-title":"Energy Build."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"106474","DOI":"10.1016\/j.buildenv.2019.106474","article-title":"Thermal and Visual Comfort, Energy Use and Environmental Performance of Glazing Systems with Solar Control Films","volume":"168","author":"Teixeira","year":"2020","journal-title":"Build. Environ."},{"key":"ref_31","unstructured":"European Commission (2020, April 10). Indoor Air Pollution: New EU Research Reveals Higher Risks than Previously Thought. Available online: https:\/\/ec.europa.eu\/commission\/presscorner\/detail\/en\/IP_03_1278."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Reis, C., and Lopes, A. (2019). Evaluating the Cooling Potential of Urban Green Spaces to Tackle Urban Climate Change in Lisbon. Sustainability, 11.","DOI":"10.3390\/su11092480"},{"key":"ref_33","unstructured":"Louren\u00e7o, D.L. (2016). Experimental Study on the Thermal and Optical Performance of Glazing Systems with Solar Control Window Films. [Master\u2019s Thesis, Department of Civil Engineering, Architecture and Georesources, Instituto Superior T\u00e9cnico, Universidade de Lisboa]. (In Portuguese)."},{"key":"ref_34","unstructured":"(2018). WINDOW Technical Documentation, Lawrence Berkeley Natl. Lab."},{"key":"ref_35","unstructured":"ISO (2005). ISO Standard 7730: Ergonomics of the Thermal Environment\u2014Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria, International Organization for Standardization."},{"key":"ref_36","unstructured":"ASHRAE (2017). ASHRAE Standard 55-2017: Thremal Environmental Conditions for Human Occupancy, Am. Soc Heating Refrig. Air-Conditioning Eng."},{"key":"ref_37","unstructured":"(2013). Regulamento de Desempenho Energ\u00e9tico Dos Edif\u00edcios de Habita\u00e7\u00e3o (REH), Decree-Law 118\/2013 of 20 of August 2013. Di\u00e1rio Rep\u00fablica, 159, 4988\u20135005."},{"key":"ref_38","unstructured":"(2013). Order 15793-K of 2 of December 2013. Di\u00e1rio Rep\u00fablica, 234, 35088-(58)\u201335088-(87)."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"(2013). Order 349-B\/2013 of 29 of November 2013. Di\u00e1rio Rep\u00fablica, 232, 6624-(18)\u20136624-(29).","DOI":"10.1007\/s00735-013-0216-x"},{"key":"ref_40","unstructured":"ISO (1998). ISO Standard 7726: Ergonomics of the Thermal Environment\u2014Instruments for Measuring Physical Quantities, International Organization for Standardization."},{"key":"ref_41","unstructured":"Moura, P.S., and de Almeida, A.T. (2009). Methodologies and Technologies for the Integrations of Renewable Resources in Portugal. Conference: Renewable Energy World Europe 2009, Department Electrical & Computer Engineering University of Coimbra Portugal."},{"key":"ref_42","unstructured":"Mardaljevic, J., Andersen, M., Roy, N., and Christoffersen, J. (2012). Daylighting metrics: Is there a relation between usefuldaylight illuminance and daylight glare probability. First Building Simulation and Optimization Conference, IBPSA."}],"container-title":["Energies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1073\/14\/5\/1388\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:32:09Z","timestamp":1760160729000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1073\/14\/5\/1388"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,3]]},"references-count":42,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2021,3]]}},"alternative-id":["en14051388"],"URL":"https:\/\/doi.org\/10.3390\/en14051388","relation":{},"ISSN":["1996-1073"],"issn-type":[{"value":"1996-1073","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,3]]}}}