{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T16:24:40Z","timestamp":1774369480532,"version":"3.50.1"},"reference-count":52,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2021,6,24]],"date-time":"2021-06-24T00:00:00Z","timestamp":1624492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Energies"],"abstract":"<jats:p>Existing megawatt-scale photovoltaic (PV) power plant producers must understand that simple and low-cost Operation and Maintenance (O&amp;M) practices, even executed by their own personal and supported by a comparison of field data with simulated ones, play a key role in improving the energy outputs of the plant. Based on a currently operating 18 MW PV plant located in an under-developing South-Asia country, we show in this paper that comparing real field data collected with simulated results allows a central vision concerning plant underperformance and valuable indications about the most important predictive maintenances actions for the plant in analysis. Simulations using the globally recognized software PVSyst were first performed to attest to the overall power plant performance. Then, its energy output was predicted using existing ground weather data located at the power plant. Compared with the actual plant\u2019s annual energy output, it was found that it was underperforming by \u22124.13%, leading to a potential monetary loss of almost 175,000 (EUR)\/year. Besides, an analysis of the O&amp;M power plant reports was performed and compared to the best global practices. It was assessed that the tracker systems\u2019 major issues are the forerunner of the most significant PV power plant underperformance. In addition, issues in inverters and combiner boxes were also reported, leading to internal shutdowns. In this case, predictive maintenance and automated plant diagnosis with a bottom-up approach using low-cost data acquisition and processing systems, starting from the strings level, were recommended.<\/jats:p>","DOI":"10.3390\/en14133798","type":"journal-article","created":{"date-parts":[[2021,6,24]],"date-time":"2021-06-24T11:01:38Z","timestamp":1624532498000},"page":"3798","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":32,"title":["Why Can Simple Operation and Maintenance (O&amp;M) Practices in Large-Scale Grid-Connected PV Power Plants Play a Key Role in Improving Its Energy Output?"],"prefix":"10.3390","volume":"14","author":[{"given":"Hamid","family":"Iftikhar","sequence":"first","affiliation":[{"name":"IDMEC, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal"}]},{"given":"Eduardo","family":"Sarquis","sequence":"additional","affiliation":[{"name":"IDMEC, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7072-5184","authenticated-orcid":false,"given":"P. J. Costa","family":"Branco","sequence":"additional","affiliation":[{"name":"IDMEC, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2021,6,24]]},"reference":[{"key":"ref_1","unstructured":"IRENA (2019). Renewable Capacity Statistics, International Renewable Energy Agency (IRENA)."},{"key":"ref_2","unstructured":"International Renewable Energy Agency (IRENA) (2019). Renewable Capacity Highlights, International Renewable Energy Agency."},{"key":"ref_3","unstructured":"REN21 Renewables (2019). 2019 Global Status Report, Secretariat."},{"key":"ref_4","unstructured":"Solar Trade, Inter Solar, and Solar Power Europe (2018). Operation & Maintenance Best Practices Guidelines, Version 3.0, SolarPower Europe."},{"key":"ref_5","unstructured":"Bem Lumby, International Finance Corporation (2015). Utility-Scale Solar Photovoltaic Power Plants in Partnership with a Project Developer\u2019s Guide, International Finance Corporation."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Lisco, F., Bukhari, F., Uli\u010dn\u00e1, S., Isbilir, K., Barth, K.L., Taylor, A., and Walls, J.M. (2020). Degradation of Hydrophobic, Anti-Soiling Coatings for Solar Module Cover Glass. Energies, 13.","DOI":"10.3390\/en13153811"},{"key":"ref_7","unstructured":"IEC 61724-1 (2017). Photovoltaic System Performance\u2014Part 1: Monitoring, IEC Central Office."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.esd.2019.10.004","article-title":"An overview on performance of PV plants commissioned at different places in the world","volume":"54","author":"Srivastava","year":"2020","journal-title":"Energy Sustain. Dev."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.esd.2021.02.004","article-title":"Performance evaluation and analysis of grid-tied large scale PV plant in Algeria","volume":"61","author":"Dahmoun","year":"2021","journal-title":"Energy Sustain. Dev."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Bosman, L.B., Leon-Salas, W.D., Hutzel, W., and Soto, E.A. (2020). PV System Predictive Maintenance: Challenges, Current Approaches, and Opportunities. Energies, 13.","DOI":"10.3390\/en13061398"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Betti, A., Tucci, M., Crisostomi, E., Piazzi, A., Barmada, S., and Thomopulos, D. (2021). Fault Prediction and Early-Detection in Large PV Power Plants Based on Self-Organizing Maps. Sensors, 21.","DOI":"10.20944\/preprints202101.0632.v1"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1016\/j.solener.2019.09.099","article-title":"New monitoring method to characterize individual modules in large photovoltaic systems","volume":"193","author":"Ortega","year":"2019","journal-title":"Sol. Energy"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"114097","DOI":"10.1016\/j.enconman.2021.114097","article-title":"Techno-economic potential assessment of mega-scale grid-connected PV power plant in five climate zones of Pakistan","volume":"237","author":"Ahmed","year":"2021","journal-title":"Energy Convers. Manag."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.renene.2020.04.137","article-title":"A review of multi-criteria decision-making applications for renewable energy site selection","volume":"157","author":"Shao","year":"2020","journal-title":"Renew. Energy"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.solener.2019.08.061","article-title":"Improved outdoor thermography and processing of infrared images for defect detection in PV modules","volume":"190","author":"Akram","year":"2019","journal-title":"Sol. Energy"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"3475","DOI":"10.1002\/er.4489","article-title":"Further progress in the research of fin-based passive cooling technique for the free-standing silicon photovoltaic panels","volume":"43","year":"2019","journal-title":"Int. J. Energy Res."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Baklouti, A., Mifdal, L., Dellagi, S., and Chelbi, A. (2020). An Optimal Preventive Maintenance Policy for a Solar Photovoltaic System. Sustainability, 12.","DOI":"10.3390\/su12104266"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Walker, H., Lockhart, E., Desai, J., Ardani, K., Klise, G., Lavrova, O., Tansy, T., Deot, J., Fox, B., and Pochiraju, A. (2020). Model of Operation-and-Maintenance Costs for Photovoltaic Systems, National Renewable Energy Lab. (NREL). (No. NREL\/TP-5C00-74840).","DOI":"10.2172\/1659995"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"02007","DOI":"10.1051\/e3sconf\/202018002007","article-title":"Predictive maintenance of photovoltaic plants using multirotor drones with automatic recharging system of Li-Po batteries","volume":"180","author":"Purece","year":"2020","journal-title":"E3S Web Conf."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.solener.2020.05.058","article-title":"Numerical analysis of photovoltaic solar panel cooling by a flat plate closed-loop pulsating heat pipe","volume":"206","author":"Alizadeh","year":"2020","journal-title":"Sol. Energy"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Sengupta, M., Habte, A., Wilbert, S., Gueymard, C., and Remund, J. (2021). Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications, National Renewable Energy Lab. (NREL). (No. NREL\/TP-5D00-77635).","DOI":"10.2172\/1778700"},{"key":"ref_22","first-page":"725","article-title":"Review and analysis of solar photovoltaic softwares","volume":"4","author":"Sharma","year":"2014","journal-title":"Int. J. Curr. Eng. Technol."},{"key":"ref_23","unstructured":"Bhattacharya, I. (2019, September 30). A Detailed Study of 7 Unique Solar PV Design and Simulation Software. Available online: https:\/\/www.linkedin.com\/pulse\/comparative-analysis-7-most-popular-solar-pv-design-bhattacharya\/?trk=mp-reader-card."},{"key":"ref_24","first-page":"11","article-title":"Comparison of different PV power simulation softwares: Case study on performance analysis of 1 MW grid-connected PV solar power plant","volume":"7","author":"Umar","year":"2018","journal-title":"Int. J. Eng. Sci. Invent."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"263","DOI":"10.3103\/S0003701X20040076","article-title":"Study of Energy Yield on Grid Connected Micro-Inverter Type 2.24 kW PV System Using PVsyst Simulation Software","volume":"56","author":"Matchanov","year":"2020","journal-title":"Appl. Sol. Energy"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1093\/ce\/zkaa030","article-title":"Design and simulation of a 1-GWp solar photovoltaic power station in Sudan","volume":"5","author":"Abdalla","year":"2021","journal-title":"Clean Energy"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Akhtar, I., Kirmani, S., and Jamil, M. (2020). Effective grid-connected solar home-based system for smart cities in India. Smart Cities\u2014Opportunities and Challenges, Springer.","DOI":"10.1007\/978-981-15-2545-2_50"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Corba, Z., Popadic, B., Milicevic, D., Dumnic, B., and Katic, V.A. (2020). A Long-Term Condition Monitoring and Performance Assessment of Grid Connected PV Power Plant with High Power Sizing Factor under Partial Shading Conditions. Energies, 13.","DOI":"10.3390\/en13184810"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1109\/JPHOTOV.2020.2978851","article-title":"Photovoltaic potential assessment and dust impacts on photovoltaic systems in Iran","volume":"10","author":"Gholami","year":"2020","journal-title":"IEEE J. Photovolt."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.solener.2020.02.062","article-title":"Analysis of cooling load on commercial building in UAE climate using building integrated photovoltaic fa\u00e7ade system","volume":"199","author":"Salameh","year":"2020","journal-title":"Sol. Energy"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.solener.2018.08.021","article-title":"Ageing and degradation in solar photovoltaic modules installed in northern Ghana","volume":"173","author":"Quansah","year":"2018","journal-title":"Sol. Energy"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"117903","DOI":"10.1016\/j.energy.2020.117903","article-title":"Performance analysis of a 10 MWp utility-scale grid-connected canal-top photovoltaic power plant under Indian climatic conditions","volume":"204","author":"Kumar","year":"2020","journal-title":"Energy"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"100409","DOI":"10.1016\/j.csite.2019.100409","article-title":"Performance, energy loss, and degradation prediction of roof-integrated crystalline solar PV system installed in Northern India","volume":"13","author":"Kumar","year":"2019","journal-title":"Case Stud. Therm. Eng."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"110139","DOI":"10.1016\/j.rser.2020.110139","article-title":"Performance evaluation of a utility-scale dual-technology photovoltaic power plant at the Shagaya Renewable Energy Park in Kuwait","volume":"133","author":"Majed","year":"2020","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.renene.2021.03.012","article-title":"Techno-economic study of photovoltaic systems performance in Shiraz, Iran","volume":"172","author":"Yazdani","year":"2021","journal-title":"Renewable Energy"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Vidal, H., Rivera, M., Wheeler, P., and Vicencio, N. (2020). The Analysis Performance of a Grid-Connected 8.2 kWp Photovoltaic System in the Patagonia Region. Sustainability, 12.","DOI":"10.3390\/su12219227"},{"key":"ref_37","unstructured":"PVsyst (2019, July 30). Array Incidence Loss. Available online: http:\/\/files.pvsyst.com\/help\/iam_loss.htm."},{"key":"ref_38","unstructured":"Upadhyay (2019, July 30). PVsyst Losses & Some Remedies. Available online: https:\/\/www.linkedin.com\/pulse\/pvsyst-losses-some-remedies-amit-upadhyay\/."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1016\/j.rser.2016.01.044","article-title":"Power loss due to soiling on solar panel: A review","volume":"59","author":"Maghami","year":"2016","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Dunn, L., Littmann, B., Caron, J.R., and Gostein, M. (2013, January 16\u201321). PV module soiling measurement uncertainty analysis. Proceedings of the IEEE 39th Photovoltaic Specialists Conference (PVSC), Tampa, FL, USA.","DOI":"10.1109\/PVSC.2013.6744236"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2920","DOI":"10.1016\/j.rser.2012.02.012","article-title":"Effect of dust, humidity and air velocity on efficiency of photovoltaic cells","volume":"16","author":"Mekhilef","year":"2012","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_42","unstructured":"Thevenard, D., Driesse, A., Pelland, S., Turcotte, D., and Poissant, Y. (2010). Uncertainty in Long-Term Photovoltaic Yield Predictions."},{"key":"ref_43","unstructured":"Emblemsv\u00e5g, J. (2020). On the levelised cost of energy of solar photovoltaics. Int. J. Sustain. Energy, 1\u201326."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Mansur, A.A., Amin, M., and Islam, K.K. (2019). Performance comparison of mismatch power loss minimization techniques in series-parallel PV array configurations. Energies, 12.","DOI":"10.3390\/en12050874"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.1016\/j.enpol.2010.11.040","article-title":"Providing all global energy with wind, water, and solar power, Part I: Technologies, energy resources, quantities and areas of infrastructure, and materials","volume":"39","author":"Jacobson","year":"2011","journal-title":"Energy Policy"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1016\/j.enconman.2010.08.007","article-title":"Measured Performance of a 1.72 kW Rooftop Grid-Connected Photovoltaic System in Ireland","volume":"52","author":"Mccormack","year":"2011","journal-title":"Energy Convers. Manag."},{"key":"ref_47","unstructured":"GENSOL (2019, May 30). Generation Assessment and Loss Justification of 315 Wp Panels in 1 MW Power Plant. Available online: https:\/\/www.slideshare.net\/AnmolJaggi\/analysis-of-pvsyst-loss-diagram."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1016\/j.egypro.2014.02.087","article-title":"Soiling and anti-soiling coatings on surfaces of solar thermal systems\u2014Featuring an economic feasibility analysis","volume":"48","author":"Lorenz","year":"2014","journal-title":"Energy Procedia"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1016\/j.solmat.2018.05.036","article-title":"Anti-soiling coatings for solar cell cover glass: Climate and surface properties influence","volume":"185","author":"Braceras","year":"2018","journal-title":"Sol. Energy Mater. Sol. Cells"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1016\/j.rser.2016.04.079","article-title":"Faults and infrared thermographic diagnosis in operating c-Si photovoltaic modules: A review of research and future challenges","volume":"62","author":"Tsanakas","year":"2016","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_51","unstructured":"Solar-DAO (2019, May 30). Everything You Need to Know About Operations & Maintenance (O&M) For Utility Scale PV Solar Plants. Available online: https:\/\/medium.com\/@solar.dao\/everything-you-need-to-know-about-operations-maintenance-o-m-for-utility-scale-pv-solar-plants-9d0048e9b9a2."},{"key":"ref_52","unstructured":"IEC Technical Specs IEC TS (2016). Photovoltaic System Performance\u2014Energy Evaluation Method, British Standards Institution [BSI]."}],"container-title":["Energies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1073\/14\/13\/3798\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:22:59Z","timestamp":1760163779000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1073\/14\/13\/3798"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,24]]},"references-count":52,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2021,7]]}},"alternative-id":["en14133798"],"URL":"https:\/\/doi.org\/10.3390\/en14133798","relation":{},"ISSN":["1996-1073"],"issn-type":[{"value":"1996-1073","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,24]]}}}