{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T16:48:06Z","timestamp":1770742086785,"version":"3.49.0"},"reference-count":42,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2022,2,14]],"date-time":"2022-02-14T00:00:00Z","timestamp":1644796800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Energies"],"abstract":"<jats:p>Achieving nearly zero-energy buildings (nZEB) is one of the main objectives defined by the European Union for achieving carbon neutrality in buildings. nZEBs are heavily reliant on distributed renewable generation energy sources, which create new challenges associated with their inherent intermittency. To achieve nZEB levels, demand management plays an essential role to balance supply and demand. Since up to two-thirds of the total consumed energy in buildings is dispended for Heating, Ventilation and Air Conditioning (HVAC) operations, intelligent control of HVAC loads is of utmost importance. The present work aims to offer a solution to improve a building microgrids\u2019 flexibility by shifting thermal loads and taking advantage of room thermal inertia. Innovation is present in using the internet of things to link several decentralized local microcontrollers with the microgrid and in the applicability of different control algorithms, such as the pre-emptive heating\/cooling of a room. The developed solution relies on smart thermostats, which can be integrated into a building management system, or in a microgrid, and are capable of fulfilling the occupants\u2019 need for comfort while complementing the building with needed power flexibility. The equipment is capable of controlling several HVAC systems to guarantee thermal and air quality comfort, as well as coordinate with a building\/microgrid operator to reduce energy costs by shifting thermal loads and enacting demand control strategies. The smart thermostat uses an algorithm to calculate room inertia and to pre-emptively heat\/cool a room to the desired temperature, avoiding peak hours, taking advantage of variable tariffs for electricity, or periods of solar generation surplus. The smart thermostat was integrated into a university campus microgrid and tested in live classrooms. Since the work was developed during the COVID-19 pandemic, special attention was given to the air quality features. Results show that smart HVAC control is a viable way to provide occupant comfort, as well as contribute to the integration of renewable generation and increase energy efficiency in buildings and microgrids.<\/jats:p>","DOI":"10.3390\/en15041359","type":"journal-article","created":{"date-parts":[[2022,2,14]],"date-time":"2022-02-14T20:26:42Z","timestamp":1644870402000},"page":"1359","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Smart Thermostats for a Campus Microgrid: Demand Control and Improving Air Quality"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5768-6088","authenticated-orcid":false,"given":"Alexandre","family":"Correia","sequence":"first","affiliation":[{"name":"Institute of System and Robotics, Department of Electrical and Computer Engineering, University of Coimbra, 3030-290 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0066-394X","authenticated-orcid":false,"given":"Lu\u00eds Miguel","family":"Ferreira","sequence":"additional","affiliation":[{"name":"Institute of System and Robotics, Department of Electrical and Computer Engineering, University of Coimbra, 3030-290 Coimbra, Portugal"}]},{"given":"Paulo","family":"Coimbra","sequence":"additional","affiliation":[{"name":"Institute of System and Robotics, Department of Electrical and Computer Engineering, University of Coimbra, 3030-290 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4852-2812","authenticated-orcid":false,"given":"Pedro","family":"Moura","sequence":"additional","affiliation":[{"name":"Institute of System and Robotics, Department of Electrical and Computer Engineering, University of Coimbra, 3030-290 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3641-5174","authenticated-orcid":false,"given":"An\u00edbal T.","family":"de Almeida","sequence":"additional","affiliation":[{"name":"Institute of System and Robotics, Department of Electrical and Computer Engineering, University of Coimbra, 3030-290 Coimbra, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2022,2,14]]},"reference":[{"key":"ref_1","unstructured":"(2021, October 27). Fernbas Energy Performance of Buildings Directive. Available online: https:\/\/ec.europa.eu\/energy\/topics\/energy-efficiency\/energy-efficient-buildings\/energy-performance-buildings-directive_en."},{"key":"ref_2","unstructured":"(2021, October 27). EUR-Lex-32010L0031-EN-EUR-Lex. Available online: https:\/\/eur-lex.europa.eu\/legal-content\/EN\/ALL\/?uri=CELEX%3A32010L0031."},{"key":"ref_3","unstructured":"(2012). Directive 2012\/27\/EU of the European Parliament and of the Council of 25 October 2012 on Energy Efficiency, Amending Directives 2009\/125\/EC and 2010\/30\/EU and Repealing Directives 2004\/8\/EC and 2006\/32\/EC Text with EEA Relevance, Official Journal of the European Union."},{"key":"ref_4","unstructured":"(2021, October 27). Nearly Zero-Energy Buildings. Available online: https:\/\/ec.europa.eu\/energy\/topics\/energy-efficiency\/energy-efficient-buildings\/nearly-zero-energy-buildings_en."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"100539","DOI":"10.1016\/j.esr.2020.100539","article-title":"Challenges of renewable energy penetration on power system flexibility: A survey","volume":"31","author":"Impram","year":"2020","journal-title":"Energy Strateg. Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"3660","DOI":"10.1109\/TPWRS.2016.2635024","article-title":"Application of Microgrids in Supporting Distribution Grid Flexibility","volume":"32","author":"Majzoobi","year":"2017","journal-title":"IEEE Trans. Power Syst."},{"key":"ref_7","unstructured":"(2021, September 13). Earth\u2019s CO2 Home Page. Available online: https:\/\/www.co2.earth\/."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1038\/nature06949","article-title":"High-resolution carbon dioxide concentration record 650,000\u2013800,000 years before present","volume":"453","author":"Luthi","year":"2008","journal-title":"Nature"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1289\/ehp.1510037","article-title":"Associations of cognitive function scores with carbon dioxide, ventilation, and volatile organic compound exposures in office workers: A controlled exposure study of green and conventional office environments","volume":"124","author":"Allen","year":"2016","journal-title":"Environ. Health Perspect."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.buildenv.2016.11.041","article-title":"The impact of working in a green certified building on cognitive function and health","volume":"114","author":"MacNaughton","year":"2017","journal-title":"Build. Environ."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Moura, P., Correia, A., Delgado, J., Fonseca, P., and De Almeida, A. (2020, January 27\u201330). University campus microgrid for supporting sustainable energy systems operation. Proceedings of the 2020 IEEE\/IAS 56th Industrial and Commercial Power Systems Technical Conference (I&CPS), Virtual.","DOI":"10.1109\/ICPS48389.2020.9176755"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1007\/s12053-018-9742-5","article-title":"Improving energy use in schools: From IEQ towards energy-efficient planning\u2014method and in-field application to two case studies","volume":"12","author":"Pereira","year":"2019","journal-title":"Energy Effic."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1016\/j.rser.2015.02.034","article-title":"Ground source heat pump carbon emissions and primary energy reduction potential for heating in buildings in europe\u2014results of a case study in portugal","volume":"45","author":"Carvalho","year":"2015","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1109\/TSG.2012.2183649","article-title":"An Evaluation of the HVAC Load Potential for Providing Load Balancing Service","volume":"3","author":"Lu","year":"2012","journal-title":"IEEE Trans. Smart Grid"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"111644","DOI":"10.1016\/j.enbuild.2021.111644","article-title":"Load shifting and energy conservation using smart thermostats in contemporary high-rise residential buildings: Estimation of runtime changes using field data","volume":"255","author":"Stopps","year":"2021","journal-title":"Energy Build."},{"key":"ref_16","unstructured":"Conde, N.L. (2020). Intelligent System for Load Monitoring and Control: Sustainable Comfort, Health and Flexible Electricity Consumtion. [Ph.D. Thesis, Universidade de Coimbra]."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1016\/j.energy.2014.07.047","article-title":"Assessment regarding energy saving and decoupling for different AHU (air handling unit) and control strategies in the hot-humid climatic region of Iraq","volume":"74","author":"Homod","year":"2014","journal-title":"Energy"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.renene.2018.03.022","article-title":"Analysis and optimization of HVAC control systems based on energy and performance considerations for smart buildings","volume":"126","author":"Homod","year":"2018","journal-title":"Renew. Energy"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"115255","DOI":"10.1016\/j.apenergy.2020.115255","article-title":"Evaluation of energy-saving potential for optimal time response of HVAC control system in smart buildings","volume":"271","author":"Homod","year":"2020","journal-title":"Appl. Energy"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"7251","DOI":"10.1109\/TIA.2019.2912133","article-title":"Advanced Microgrid Energy Management System for Future Sustainable and Resilient Power Grid","volume":"55","author":"Yang","year":"2019","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_21","unstructured":"Prill, R. (2000). Why Measure Carbon Dioxide Inside Buildings?, Washington State University Extension Energy Program 5."},{"key":"ref_22","unstructured":"(2021, October 01). North Carolina Energy Office Ventilation and Indoor Air Quality Energy Saving\u2013Fact Sheet 2010, Available online: https:\/\/deq.nc.gov\/media\/1440\/download."},{"key":"ref_23","unstructured":"Hara, S. (2021, October 01). Monitoring Carbon Dioxide Concentration in a Room as an Indicator of Ventilation|COVID-19 AI and Simulation Project, AIST. Available online: https:\/\/www.covid19-ai.jp\/en-us\/presentation\/2020_rq2_infection_prevention\/articles\/article010\/."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"111487","DOI":"10.1016\/j.envres.2021.111487","article-title":"Effects of air pollution on health: A mapping review of systematic reviews and meta-analyses","volume":"201","author":"Dominski","year":"2021","journal-title":"Environ. Res."},{"key":"ref_25","unstructured":"(2021, August 05). ASHRAE Standards 62.1 & 62.2. Available online: https:\/\/www.ashrae.org\/technical-resources\/bookstore\/standards-62-1-62-2."},{"key":"ref_26","unstructured":"World Health Organization (2021, October 01). Roadmap to Improve and Ensure Good Indoor Ventilation in the Context of COVID-19. Available online: https:\/\/www.who.int\/publications\/i\/item\/9789240021280."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Birnir, B. (2020). Ventilation and the SARS-CoV-2 coronavirus: Analysis of outbreaks in a restaurant and on a bus in china, and at a call center in South Korea. medRxiv.","DOI":"10.1101\/2020.09.11.20192997"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Birnir, B., and Angheluta, L. (2020). The Build-Up of droplet\/Aerosols carrying the SARS-CoV-2 coronavirus, in confined spaces. medRxiv.","DOI":"10.1101\/2020.08.11.20173195"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"045205","DOI":"10.1063\/5.0045582","article-title":"Breathing, virus transmission, and social distancing\u2014An experimental visualization study","volume":"11","author":"Arumuru","year":"2021","journal-title":"AIP Adv."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1111\/risa.13500","article-title":"Consideration of the Aerosol Transmission for COVID-19 and Public Health","volume":"40","author":"Anderson","year":"2020","journal-title":"Risk Anal."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"111765","DOI":"10.1016\/j.envres.2021.111765","article-title":"A review of methods to reduce the probability of the airborne spread of COVID-19 in ventilation systems and enclosed spaces","volume":"203","author":"Berry","year":"2021","journal-title":"Environ. Res."},{"key":"ref_32","unstructured":"(2021, September 04). Carbon Dioxide Monitoring to Lower the Coronavirus Threat. Available online: https:\/\/smartbuildingsmagazine.com\/features\/carbon-dioxide-monitoring-to-lower-the-coronavirus-threat."},{"key":"ref_33","unstructured":"(2021, August 31). Covid: Classrooms in England to Get CO2 Monitors to Help with Ventilation. Available online: http:\/\/www.theguardian.com\/education\/2021\/aug\/21\/classrooms-england-monitor-air-quality-effort-combat-covid-better-ventilation."},{"key":"ref_34","unstructured":"(2021, September 01). Escolas Deviam Testar a Qualidade do ar. Available online: https:\/\/www.dn.pt\/sociedade\/escolas-deviam-testar-a-qualidade-do-ar-14061766.html."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"109781","DOI":"10.1016\/j.mehy.2020.109781","article-title":"Airborne route and bad use of ventilation systems as non-negligible factors in SARS-CoV-2 transmission","volume":"141","author":"Correia","year":"2020","journal-title":"Med. Hypotheses"},{"key":"ref_36","first-page":"46","article-title":"An Analysis of the Transmission Modes of COVID-19 in Light of the Concepts of Indoor Air Quality","volume":"3","year":"2020","journal-title":"REHVA J."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1108\/IJSHE-09-2017-0145","article-title":"Sustainability in university campus: Options for achieving nearly zero energy goals","volume":"19","author":"Fonseca","year":"2018","journal-title":"Int. J. Sustain. High. Educ."},{"key":"ref_38","unstructured":"Incropera, F.P., DeWitt, D.P., Bergman, T.L., and Lavine, A.S. (2007). Fundamentals of Heat and Mass Transfer, John Wiley. [6th ed.]."},{"key":"ref_39","unstructured":"(2021, October 01). CO2 Monitoring: A Benchmark for Indoor Air Quality?. Available online: https:\/\/www.pressac.com\/insights\/co2-levels-a-benchmark-for-indoor-air-quality\/."},{"key":"ref_40","unstructured":"(2021, October 01). United States Environmental Protection Agency APPENDIX B\u2013Overview of Acute Health Effects, Available online: https:\/\/www.epa.gov\/sites\/default\/files\/2015-06\/documents\/co2appendixb.pdf."},{"key":"ref_41","unstructured":"(2021, October 01). American Society of Heating, Refrigerating and Air-Conditioning Engineers ANSI\/ASHRAE Addendum d to ANSI\/ASHRAE Standard 62.1-2016. Available online: https:\/\/www.ashrae.org\/technical-resources\/standards-and-guidelines\/standards-addenda\/addenda-to-standard-62-1-2016."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1111\/j.1600-0668.2006.00432.x","article-title":"Droplet fate in indoor environments, or can we prevent the spread of infection?","volume":"16","author":"Morawska","year":"2006","journal-title":"Indoor Air"}],"container-title":["Energies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1073\/15\/4\/1359\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:19:04Z","timestamp":1760134744000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1073\/15\/4\/1359"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,14]]},"references-count":42,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2022,2]]}},"alternative-id":["en15041359"],"URL":"https:\/\/doi.org\/10.3390\/en15041359","relation":{},"ISSN":["1996-1073"],"issn-type":[{"value":"1996-1073","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,14]]}}}