{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T18:21:47Z","timestamp":1775672507063,"version":"3.50.1"},"reference-count":88,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2024,4,28]],"date-time":"2024-04-28T00:00:00Z","timestamp":1714262400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia (FCT)","award":["FCT PD\/BD\/150576\/2020"],"award-info":[{"award-number":["FCT PD\/BD\/150576\/2020"]}]},{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia (FCT)","award":["UIDB\/04625\/2020"],"award-info":[{"award-number":["UIDB\/04625\/2020"]}]},{"DOI":"10.13039\/501100001871","name":"FCT","doi-asserted-by":"publisher","award":["FCT PD\/BD\/150576\/2020"],"award-info":[{"award-number":["FCT PD\/BD\/150576\/2020"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"FCT","doi-asserted-by":"publisher","award":["UIDB\/04625\/2020"],"award-info":[{"award-number":["UIDB\/04625\/2020"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Energies"],"abstract":"<jats:p>Electrochromic glazing alters its optical properties in the absence\/presence of an electrical charge, varying from clear to dark to control daylighting and solar heat gains. This study aims to evaluate the impact of an electrochromic glazing, with indoor glare or temperature control, on the energy performance and thermal and visual comfort of an office room under three European climates, using a calibrated simulation model. The novelty of the paper lies in its combined performance assessment, using different standards and metrics. The results showed reduced climatization energy requirements with temperature control, but significantly increased artificial lighting energy use. Glare control achieved useful illuminance levels during 74\u201380% of working hours. Concerning temperature control, working hours within thermal comfort increased (21\u201343%) under a free-float regime. Moreover, the performance of this glazing was compared to that of a clear glazing with\/without a reflective film and a thermochromic glazing for different solar orientations. The electrochromic glazing with glare control showed the highest energy savings (14\u201336%) for a western orientation, and the lowest negative impact on daylighting for a northern orientation. The best glare reduction was achieved with the reflective film. Considering the free-float regime, the electrochromic glazing, with temperature control, showed the highest increase in working hours within thermal comfort (6\u20139%) for a western orientation.<\/jats:p>","DOI":"10.3390\/en17092110","type":"journal-article","created":{"date-parts":[[2024,4,29]],"date-time":"2024-04-29T08:49:24Z","timestamp":1714380564000},"page":"2110","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Simulation-Based Evaluation of the Impact of an Electrochromic Glazing on the Energy Use and Indoor Comfort of an Office Room"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3391-1495","authenticated-orcid":false,"given":"Henriqueta","family":"Teixeira","sequence":"first","affiliation":[{"name":"CERIS, Department of Civil Engineering, Architecture and Environment (DECivil), Instituto Superior T\u00e9cnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal"}]},{"given":"A.","family":"Moret Rodrigues","sequence":"additional","affiliation":[{"name":"CERIS, Department of Civil Engineering, Architecture and Environment (DECivil), Instituto Superior T\u00e9cnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1007-1756","authenticated-orcid":false,"given":"Daniel","family":"Aelenei","sequence":"additional","affiliation":[{"name":"Centre of Technology and Systems\/UNINOVA, Department of Civil Engineering, Faculty of Science and Technology, Universidade Nova de Lisboa, 2829-516 Caparica, Portugal"},{"name":"Laborat\u00f3rio Associado de Sistemas Inteligentes, LASI, 4800-058 Guimar\u00e3es, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1499-1370","authenticated-orcid":false,"given":"M. Gl\u00f3ria","family":"Gomes","sequence":"additional","affiliation":[{"name":"CERIS, Department of Civil Engineering, Architecture and Environment (DECivil), Instituto Superior T\u00e9cnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2024,4,28]]},"reference":[{"key":"ref_1","unstructured":"United Nations Environment Programme (2024). Global Status Report for Buildings and Construction: Beyond Foundations\u2014Mainstreaming Sustainable Solutions to Cut Emissions from the Buildings Sector."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/J.ENG.2016.01.008","article-title":"A New Look at Building Facades as Infrastructure","volume":"2","author":"Sung","year":"2016","journal-title":"Engineering"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.buildenv.2017.05.016","article-title":"Multi-criteria selection of fa\u00e7ade systems based on sustainability criteria","volume":"121","author":"Nadoushani","year":"2017","journal-title":"Build. Environ."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Fernando, D., Navaratnam, S., Rajeev, P., and Sanjayan, J. (2023). Study of Technological Advancement and Challenges of Fa\u00e7ade System for Sustainable Building: Current Design Practice. Sustainability, 15.","DOI":"10.3390\/su151914319"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.rser.2014.09.020","article-title":"The role of window glazing on daylighting and energy saving in buildings","volume":"42","author":"Hee","year":"2015","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"113177","DOI":"10.1016\/j.enbuild.2023.113177","article-title":"The role of windows on building performance under current and future weather conditions of European climates","volume":"292","author":"Festa","year":"2023","journal-title":"Energy Build."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.scs.2016.05.014","article-title":"A thermal performance parametric study of window type, orientation, size and shadowing effect","volume":"26","author":"Amaral","year":"2016","journal-title":"Sustain. Cities Soc."},{"key":"ref_8","first-page":"47","article-title":"Solar and visible optical properties of glazing systems with venetian blinds: Numerical, experimental and blind control study","volume":"71","author":"Gomes","year":"2014","journal-title":"J. Affect. Disord."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.enbuild.2016.03.014","article-title":"Solar shading control strategy for office buildings in cold climate","volume":"118","author":"Karlsen","year":"2016","journal-title":"Energy Build."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.jobe.2018.03.018","article-title":"Shading devices optimization to enhance thermal comfort and energy performance of a residential building in Morocco","volume":"18","author":"Sghiouri","year":"2018","journal-title":"J. Build. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Moghaddam, S.A., Mattsson, M., Ameen, A., Akander, J., Da Silva, M.G., and Sim\u00f5es, N. (2021). Low-emissivity window films as an energy retrofit option for a historical stone building in cold climate. Energies, 14.","DOI":"10.3390\/en14227584"},{"key":"ref_12","first-page":"106474","article-title":"Thermal and visual comfort, energy use and environmental performance of glazing systems with solar control films","volume":"168","author":"Teixeira","year":"2019","journal-title":"J. Affect. Disord."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.enbuild.2019.06.003","article-title":"Thermal, luminous and energy performance of solar control films in single-glazed windows: Use of energy performance criteria to support decision making","volume":"198","author":"Pereira","year":"2019","journal-title":"Energy Build."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Michael, M., Favoino, F., Jin, Q., Luna-Navarro, A., and Overend, M. (2023). A Systematic Review and Classification of Glazing Technologies for Building Fa\u00e7ades. Energies, 16.","DOI":"10.3390\/en16145357"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"100582","DOI":"10.1016\/j.clet.2022.100582","article-title":"Concept of net zero energy buildings (NZEB)\u2014A literature review","volume":"11","author":"Jaysawal","year":"2022","journal-title":"Clean. Eng. Technol."},{"key":"ref_16","unstructured":"Favoino, F., Loonen, R.C.G.M., Doya, M., Goia, F., Bedon, C., and Babich, F. (2019, December 18). Building Performance Simulation and Characterisation of Adaptive Facades\u2014Adaptive Facade Network. Available online: http:\/\/tu1403.eu\/wp-content\/uploads\/Vol-3-2_for-web-Open-Access_9789463661119.pdf."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.solmat.2009.08.021","article-title":"Properties, requirements and possibilities of smart windows for dynamic daylight and solar energy control in buildings: A state-of-the-art review","volume":"94","author":"Baetens","year":"2010","journal-title":"Sol. Energy Mater. Sol. Cells"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Brzezicki, M. (2021). A systematic review of the most recent concepts in smart windows technologies with a focus on electrochromics. Sustainability, 13.","DOI":"10.3390\/su13179604"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1016\/j.renene.2017.12.049","article-title":"Active dynamic windows for buildings: A review","volume":"119","author":"Casini","year":"2018","journal-title":"Renew. Energy"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.solmat.2016.08.026","article-title":"A review of conventional, advanced, and smart glazing technologies and materials for improving indoor environment","volume":"159","author":"Rezaei","year":"2017","journal-title":"Sol. Energy Mater. Sol. Cells"},{"key":"ref_21","unstructured":"Jones, G., and Dean, M. (2016). Woodhead Publishing Series in Civil and Structural Engineering, Woodhead Publishing."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1970153","DOI":"10.1002\/aenm.201970153","article-title":"Smart Windows: Smart Windows: Electro-, Thermo-, Mechano-, Photochromics, and Beyond","volume":"9","author":"Ke","year":"2019","journal-title":"Adv. Energy Mater."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1800113","DOI":"10.1002\/adfm.201800113","article-title":"Emerging Thermal-Responsive Materials and Integrated Techniques Targeting the Energy-Efficient Smart Window Application","volume":"28","author":"Ke","year":"2018","journal-title":"Adv. Funct. Mater."},{"key":"ref_24","unstructured":"Leftheriotis, G., and Yianoulis, P. (2012). Comprehensive Renewable Energy, Elsevier."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1707","DOI":"10.1016\/j.joule.2018.06.018","article-title":"Thermochromic VO2 for Energy-Efficient Smart Windows","volume":"2","author":"Cui","year":"2018","journal-title":"Joule"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.solener.2021.01.013","article-title":"Optimization of the thermochromic glazing design for curtain wall buildings based on experimental measurements and dynamic simulation","volume":"216","author":"Arnesano","year":"2021","journal-title":"Sol. Energy"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"109828","DOI":"10.1016\/j.solmat.2019.02.041","article-title":"Comparison of the energy saving potential of adaptive and controllable smart windows: A state-of-the-art review and simulation studies of thermochromic, photochromic and electrochromic technologies","volume":"200","author":"Jelle","year":"2019","journal-title":"Sol. Energy Mater. Sol. Cells"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Arnaoutakis, G.E., and Katsaprakakis, D.A. (2021). Energy Performance of Buildings with Thermochromic Windows in Mediterranean Climates. Energies, 14.","DOI":"10.3390\/en14216977"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"109920","DOI":"10.1016\/j.enbuild.2020.109920","article-title":"Energy saving performance of thermochromic coatings with different colors for buildings","volume":"215","author":"Yuxuan","year":"2020","journal-title":"Energy Build."},{"key":"ref_30","unstructured":"Favoino, F., Giovannini, L., Pellegrino, A., and Serra, V. (2021). Eco-Efficient Materials for Reducing Cooling Needs in Buildings and Construction, Elsevier Ltd."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"113335","DOI":"10.1016\/j.apenergy.2019.113335","article-title":"Thermochromic glazing performance: From component experimental characterisation to whole building performance evaluation","volume":"251","author":"Giovannini","year":"2019","journal-title":"Appl. Energy"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.solmat.2016.01.008","article-title":"Thermal and visual performance of real and theoretical thermochromic glazing solutions for office buildings","volume":"149","author":"Costanzo","year":"2016","journal-title":"Sol. Energy Mater. Sol. Cells"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1016\/j.renene.2018.04.038","article-title":"Advances in switchable and highly insulating autonomous (self-powered) glazing systems for adaptive low energy buildings","volume":"126","author":"Ghosh","year":"2018","journal-title":"Renew. Energy"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"112403","DOI":"10.1016\/j.enbuild.2022.112403","article-title":"Energy saving through building automation systems: Experimental and numerical study of a smart glass with liquid crystal and its control logics in summertime","volume":"273","author":"Ruggiero","year":"2022","journal-title":"Energy Build."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"105101","DOI":"10.1016\/j.jobe.2022.105101","article-title":"Polymer-Dispersed Liquid Crystal (PDLC) smart switchable windows for less-energy hungry buildings and visual comfort in hot desert climate","volume":"59","author":"Mesloub","year":"2022","journal-title":"J. Build. Eng."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"124073","DOI":"10.1016\/j.energy.2022.124073","article-title":"Assessment of the overall energy performance of an SPD smart window in a hot desert climate","volume":"252","author":"Mesloub","year":"2022","journal-title":"Energy"},{"key":"ref_37","first-page":"227","article-title":"Evaluation of building energy and daylight performance according to applying electrochromic and pdcl (Polymer dispersed liquid crystal) to office building in South Korea","volume":"10","author":"Oh","year":"2019","journal-title":"Int. J. Sustain. Build. Technol. Urban Dev."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Cannavale, A., Ayr, U., Fiorito, F., and Martellotta, F. (2020). Smart electrochromic windows to enhance building energy efficiency and visual comfort. Energies, 13.","DOI":"10.3390\/en13061449"},{"key":"ref_39","first-page":"114338","article-title":"Optimal control parameter for electrochromic glazing operation in commercial buildings under different climatic conditions","volume":"260","author":"Lee","year":"2019","journal-title":"Appl. Energy"},{"key":"ref_40","first-page":"2829","article-title":"Comparing the energy performance of an electrochromic window under various control strategies","volume":"42","author":"Assimakopoulos","year":"2007","journal-title":"J. Affect. Disord."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.solener.2016.04.022","article-title":"Control criteria of electrochromic glasses for energy savings in mediterranean buildings refurbishment","volume":"134","author":"Tavares","year":"2016","journal-title":"Sol. Energy"},{"key":"ref_42","first-page":"479","article-title":"Visual and energy management of electrochromic windows in Mediterranean climate","volume":"38","author":"Gugliermetti","year":"2003","journal-title":"J. Affect. Disord."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"900","DOI":"10.1016\/j.egypro.2018.08.096","article-title":"Innovative electrochromic devices: Energy savings and visual comfort effects","volume":"148","author":"Cannavale","year":"2018","journal-title":"Energy Procedia"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.enbuild.2017.07.046","article-title":"Office buildings with electrochromic windows: A sensitivity analysis of design parameters on energy performance, and thermal and visual comfort","volume":"153","author":"Dussault","year":"2017","journal-title":"Energy Build."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.apenergy.2017.02.007","article-title":"A comparative energy analysis of three electrochromic glazing technologies in commercial and residential buildings","volume":"192","author":"DeForest","year":"2017","journal-title":"Appl. Energy"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"106779","DOI":"10.1016\/j.jobe.2023.106779","article-title":"Experimental investigation on indoor thermal environment improvement and energy-saving of electrochromic window under Singapore\u2019s tropical climate","volume":"73","author":"Li","year":"2023","journal-title":"J. Build. Eng."},{"key":"ref_47","first-page":"2439","article-title":"Energy and visual comfort performance of electrochromic windows with overhangs","volume":"42","author":"Lee","year":"2007","journal-title":"J. Affect. Disord."},{"key":"ref_48","first-page":"1171","article-title":"Effect of switchable glazing on discomfort glare from windows","volume":"44","author":"Piccolo","year":"2009","journal-title":"J. Affect. Disord."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"111738","DOI":"10.1016\/j.enbuild.2021.111738","article-title":"Behind electrochromic glazing: Assessing user\u2019s perception of glare from the sun in a controlled environment","volume":"256","author":"Jain","year":"2021","journal-title":"Energy Build."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"2464","DOI":"10.1016\/j.egypro.2015.11.230","article-title":"Thermal comfort and visual comfort in an office building equipped with smart electrochromic glazing: An experimental study","volume":"78","author":"Ajaji","year":"2015","journal-title":"Energy Procedia"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.ijsbe.2012.09.001","article-title":"Electrochromic dynamic windows for office buildings","volume":"1","author":"Sbar","year":"2012","journal-title":"Int. J. Sustain. Built Environ."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.enbuild.2012.10.057","article-title":"Lighting energy savings potential of split-pane electrochromic windows controlled for daylighting with visual comfort","volume":"61","author":"Fernandes","year":"2013","journal-title":"Energy Build."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Park, B.R., Hong, J., Choi, E.J., Choi, Y.J., Lee, C., and Moon, J.W. (2019). Improvement in energy performance of building envelope incorporating electrochromic windows (ECWs). Energies, 12.","DOI":"10.3390\/en12061181"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.enpol.2013.07.038","article-title":"Evaluation of electrochromic windows impact in the energy performance of buildings in mediterranean climates","volume":"67","author":"Tavares","year":"2013","journal-title":"Energy Policy"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.solener.2009.10.021","article-title":"Evaluation of control strategies for different smart window combinations using computer simulations","volume":"84","author":"Jonsson","year":"2010","journal-title":"Sol. Energy"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.solener.2021.05.021","article-title":"Effect of electrochromic windows on energy consumption of high-rise office buildings in different climate regions of Iran","volume":"223","author":"Fathi","year":"2021","journal-title":"Sol. Energy"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.apenergy.2018.05.034","article-title":"Energy savings due to building integration of innovative solid-state electrochromic devices","volume":"225","author":"Cannavale","year":"2018","journal-title":"Appl. Energy"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1016\/j.solener.2008.11.013","article-title":"Daylighting performance of an electrochromic window in a small scale test-cell","volume":"83","author":"Piccolo","year":"2009","journal-title":"Sol. Energy"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"1409","DOI":"10.1016\/j.enbuild.2010.03.010","article-title":"Thermal performance of an electrochromic smart window tested in an environmental test cell","volume":"42","author":"Piccolo","year":"2010","journal-title":"Energy Build."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.enbuild.2017.12.049","article-title":"Energy performance of an electrochromic switchable glazing: Experimental and computational assessments","volume":"165","author":"Piccolo","year":"2018","journal-title":"Energy Build."},{"key":"ref_61","first-page":"4330893","article-title":"Effects of Electrochromic Glass Window on Energy Efficiency, Thermal and Visual Performances Under Tropical Climate","volume":"76","author":"Li","year":"2023","journal-title":"SSRN Electron. J."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.enbuild.2011.12.003","article-title":"End user impacts of automated electrochromic windows in a pilot retrofit application","volume":"47","author":"Lee","year":"2012","journal-title":"Energy Build."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.enbuild.2005.02.009","article-title":"Daylighting control performance of a thin-film ceramic electrochromic window: Field study results","volume":"38","author":"Lee","year":"2006","journal-title":"Energy Build."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1016\/S0927-0248(01)00101-5","article-title":"Application issues for large-area electrochromic windows in commercial buildings","volume":"71","author":"Lee","year":"2002","journal-title":"Sol. Energy Mater. Sol. Cells"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.enbuild.2019.06.042","article-title":"Heating and cooling loads with electrochromic glazing in Mediterranean climate","volume":"201","author":"Frattolillo","year":"2019","journal-title":"Energy Build."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"109115","DOI":"10.1016\/j.buildenv.2022.109115","article-title":"Assessment of the visual, thermal and energy performance of static vs thermochromic double-glazing under different European climates","volume":"217","author":"Teixeira","year":"2022","journal-title":"Build. Environ."},{"key":"ref_67","unstructured":"(2022, March 31). Optics Software Downloads. Windows and Daylighting, Available online: https:\/\/windows.lbl.gov\/tools\/optics\/software-download."},{"key":"ref_68","unstructured":"Curcija, C., Vidanovic, S., Hart, R., Jonsson, J., and Mitchell, R. (2018). WINDOW Technical Documentation, Lawrence Berkeley National Laboratory."},{"key":"ref_69","unstructured":"Trimble Inc (2016, November 03). Sketchup Pro. Available online: https:\/\/www.sketchup.com\/."},{"key":"ref_70","unstructured":"(2018, December 30). EnergyPlus Simulation Software. Available online: https:\/\/energyplus.net."},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"Teixeira, H., Gomes, M.d.G., Rodrigues, A.M., and Pereira, J. (2021). In-Service Thermal and Luminous Performance Monitoring of a Refurbished Building with Solar Control Films on the Glazing System. Energies, 14.","DOI":"10.3390\/en14051388"},{"key":"ref_72","unstructured":"(2021, January 28). Weather Data by Location. EnergyPlus. Available online: https:\/\/energyplus.net\/weather-location\/europe_wmo_region_6\/PRT\/\/PRT_Lisboa.085360_INETI."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"180214","DOI":"10.1038\/sdata.2018.214","article-title":"Present and future K\u00f6ppen-Geiger climate classification maps at 1-km resolution","volume":"5","author":"Beck","year":"2018","journal-title":"Sci. Data"},{"key":"ref_74","unstructured":"(2024, April 25). Dire\u00e7\u00e3o-Geral de Energia e Geologia and ADENE, Manual T\u00e9cnico para a Avalia\u00e7\u00e3o do Desempenho Energ\u00e9tico dos Edif\u00edcios. Available online: https:\/\/www.sce.pt\/wp-content\/uploads\/2021\/07\/Manual-SCE.pdf."},{"key":"ref_75","unstructured":"(2017). Thremal Environmental Conditions for Human Occupancy (Standard No. ASHRAE Standard 55-2017)."},{"key":"ref_76","unstructured":"(2005). Ergonomics of the Thermal Environment\u2014Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria (Standard No. ISO Standard 7730)."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1191\/1365782805li128oa","article-title":"Useful daylight illuminance: A new paradigm for assessing daylight in buildings","volume":"37","author":"Nabil","year":"2005","journal-title":"Light. Res. Technol."},{"key":"ref_78","unstructured":"Mardaljevic, J., Andersen, M., Roy, N., and Christoffersen, J. (2012, January 10\u201311). Daylighting metrics: I there a relation between useful daylight illuminance and daylight glare probability?. Proceedings of the First Building Simulation and Optimization Conference, Loughborough, UK."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/0003-6870(72)90102-0","article-title":"Glare from daylighting in buildings","volume":"3","author":"Hopkinson","year":"1972","journal-title":"Appl. Ergon."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"112037","DOI":"10.1016\/j.solmat.2022.112037","article-title":"Different ion-based electrolytes for electrochromic devices: A review","volume":"248","author":"Ding","year":"2022","journal-title":"Sol. Energy Mater. Sol. Cells"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"2100431","DOI":"10.1002\/pssa.202100431","article-title":"Structural Investigations in Electrochromic Vanadium Pentoxide Thin Films","volume":"219","author":"Romanitan","year":"2021","journal-title":"Phys. Status Solidi (A) Appl. Mater. Sci."},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Mouratis, K., Tudose, V., Romanitan, C., Pachiu, C., Tutunaru, O., Suchea, M., Couris, S., Vernardou, D., and Emmanouel, K. (2020). Electrochromic performance of V2O5 thin films grown by spray pyrolysis. Materials, 13.","DOI":"10.3390\/ma13173859"},{"key":"ref_83","unstructured":"ANSI\/ASHRAE (2002). ASHRAE Guideline 14-2002 Measurement of Energy and Demand Savings, ASHRAE."},{"key":"ref_84","unstructured":"(2019). Energy Performance of Buildings. Ventilation for Buildings (Standard No. BS EN 16798)."},{"key":"ref_85","first-page":"250","article-title":"Dynamic predictive clothing insulation models based on outdoor air and indoor operative temperatures","volume":"59","author":"Schiavon","year":"2013","journal-title":"J. Affect. Disord."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"1948","DOI":"10.1016\/j.rser.2010.03.040","article-title":"Analysis of daylight calculated using the EnergyPlus programme","volume":"14","author":"Ramos","year":"2010","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1177\/1477153519826003","article-title":"Cross-validation and robustness of daylight glare metrics","volume":"51","author":"Wienold","year":"2018","journal-title":"Light. Res. Technol."},{"key":"ref_88","first-page":"108335","article-title":"Comparing performance of discomfort glare metrics in high and low adaptation levels","volume":"206","author":"Quek","year":"2021","journal-title":"J. Affect. Disord."}],"container-title":["Energies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1073\/17\/9\/2110\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:35:22Z","timestamp":1760106922000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1073\/17\/9\/2110"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,28]]},"references-count":88,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2024,5]]}},"alternative-id":["en17092110"],"URL":"https:\/\/doi.org\/10.3390\/en17092110","relation":{},"ISSN":["1996-1073"],"issn-type":[{"value":"1996-1073","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,28]]}}}