{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T03:25:17Z","timestamp":1768620317205,"version":"3.49.0"},"reference-count":35,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2022,4,30]],"date-time":"2022-04-30T00:00:00Z","timestamp":1651276800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"European Union\u2019s Horizon 2020 research and innovation program under the grant agreement","award":["PCIF\/GFC\/0109\/2017"],"award-info":[{"award-number":["PCIF\/GFC\/0109\/2017"]}]},{"name":"European Union\u2019s Horizon 2020 research and innovation program under the grant agreement","award":["PCIF\/MPG\/0108\/2017"],"award-info":[{"award-number":["PCIF\/MPG\/0108\/2017"]}]},{"name":"European Union\u2019s Horizon 2020 research and innovation program under the grant agreement","award":["PCIF\/MPG\/0147\/2019"],"award-info":[{"award-number":["PCIF\/MPG\/0147\/2019"]}]},{"name":"European Union\u2019s Horizon 2020 research and innovation program under the grant agreement","award":["PCIF\/SSO\/0163\/2019"],"award-info":[{"award-number":["PCIF\/SSO\/0163\/2019"]}]},{"DOI":"10.13039\/501100001871","name":"FireStorm","doi-asserted-by":"publisher","award":["PCIF\/GFC\/0109\/2017"],"award-info":[{"award-number":["PCIF\/GFC\/0109\/2017"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"FireStorm","doi-asserted-by":"publisher","award":["PCIF\/MPG\/0108\/2017"],"award-info":[{"award-number":["PCIF\/MPG\/0108\/2017"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"FireStorm","doi-asserted-by":"publisher","award":["PCIF\/MPG\/0147\/2019"],"award-info":[{"award-number":["PCIF\/MPG\/0147\/2019"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"FireStorm","doi-asserted-by":"publisher","award":["PCIF\/SSO\/0163\/2019"],"award-info":[{"award-number":["PCIF\/SSO\/0163\/2019"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"McFire","doi-asserted-by":"publisher","award":["PCIF\/GFC\/0109\/2017"],"award-info":[{"award-number":["PCIF\/GFC\/0109\/2017"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"McFire","doi-asserted-by":"publisher","award":["PCIF\/MPG\/0108\/2017"],"award-info":[{"award-number":["PCIF\/MPG\/0108\/2017"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"McFire","doi-asserted-by":"publisher","award":["PCIF\/MPG\/0147\/2019"],"award-info":[{"award-number":["PCIF\/MPG\/0147\/2019"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"McFire","doi-asserted-by":"publisher","award":["PCIF\/SSO\/0163\/2019"],"award-info":[{"award-number":["PCIF\/SSO\/0163\/2019"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"Smokestorm","doi-asserted-by":"publisher","award":["PCIF\/GFC\/0109\/2017"],"award-info":[{"award-number":["PCIF\/GFC\/0109\/2017"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"Smokestorm","doi-asserted-by":"publisher","award":["PCIF\/MPG\/0108\/2017"],"award-info":[{"award-number":["PCIF\/MPG\/0108\/2017"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"Smokestorm","doi-asserted-by":"publisher","award":["PCIF\/MPG\/0147\/2019"],"award-info":[{"award-number":["PCIF\/MPG\/0147\/2019"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"Smokestorm","doi-asserted-by":"publisher","award":["PCIF\/SSO\/0163\/2019"],"award-info":[{"award-number":["PCIF\/SSO\/0163\/2019"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"SafeFire","doi-asserted-by":"publisher","award":["PCIF\/GFC\/0109\/2017"],"award-info":[{"award-number":["PCIF\/GFC\/0109\/2017"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"SafeFire","doi-asserted-by":"publisher","award":["PCIF\/MPG\/0108\/2017"],"award-info":[{"award-number":["PCIF\/MPG\/0108\/2017"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"SafeFire","doi-asserted-by":"publisher","award":["PCIF\/MPG\/0147\/2019"],"award-info":[{"award-number":["PCIF\/MPG\/0147\/2019"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"SafeFire","doi-asserted-by":"publisher","award":["PCIF\/SSO\/0163\/2019"],"award-info":[{"award-number":["PCIF\/SSO\/0163\/2019"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Fire"],"abstract":"<jats:p>Wildland fires are frequent events worldwide, particularly in the European-Mediterranean region, USA, and Australia. These fires have been more frequent and intense in recent years due to climate changes and may cause significant damage, especially when reaching the Wildland-Urban Interface (WUI) areas. The presence of liquefied petroleum gas (LPG) cylinders may cause severe events in WUI areas, as occurred in Portugal during the large wildfires of 2017, which could have been avoided if the cylinders were protected. Devices for protecting the parts of houses under WUI fire were previously presented, but a protective device for cylinders was not. In this work, a protective device for LPG cylinders made with a thin fabric with an aluminum coating on the external face was tested in laboratory and field conditions. The cylinder and the fabric were equipped with thermocouples and heat flux sensors attached to their surfaces. The tests showed that the device gave effective protection to the cylinder, decreasing the radiative heat flux that reaches it and keeping it in a safe condition when exposed to a fire; consequently preventing extreme behavior such as an explosion.<\/jats:p>","DOI":"10.3390\/fire5030063","type":"journal-article","created":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T06:23:08Z","timestamp":1651386188000},"page":"63","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["A Protection for LPG Domestic Cylinders at Wildland-Urban Interface Fire"],"prefix":"10.3390","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9255-4219","authenticated-orcid":false,"given":"Thiago Fernandes","family":"Barbosa","sequence":"first","affiliation":[{"name":"Department of Civil Engineering, University of Coimbra, ADAI, Rua Lu\u00eds Reis Santos, P\u00f3lo II, 3030-788 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8651-4007","authenticated-orcid":false,"given":"Lu\u00eds","family":"Reis","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Coimbra, ADAI, Rua Lu\u00eds Reis Santos, P\u00f3lo II, 3030-788 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3964-9400","authenticated-orcid":false,"given":"Jorge","family":"Raposo","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Coimbra, ADAI, Rua Lu\u00eds Reis Santos, P\u00f3lo II, 3030-788 Coimbra, Portugal"}]},{"given":"Domingos Xavier","family":"Viegas","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Coimbra, ADAI, Rua Lu\u00eds Reis Santos, P\u00f3lo II, 3030-788 Coimbra, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2022,4,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Tedim, F., Leone, V., Amraoui, M., Bouillon, C., Coughlan, M., Delogu, G., Fernandes, P., Ferreira, C., McCaffrey, S., and McGee, T. (2018). Defining Extreme Wildfire Events: Difficulties, Challenges, and Impacts. Fire, 1.","DOI":"10.3390\/fire1010009"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Ribeiro, L.M., Rodrigues, A., Lucas, D., and Viegas, D.X. (2020). The impact on structures of the pedr\u00f3g\u00e3o grande fire complex in June 2017 (Portugal). Fire, 3.","DOI":"10.3390\/fire3040057"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"103349","DOI":"10.1016\/j.firesaf.2021.103349","article-title":"Fire downwind a flat surface entering a canyon by lateral spread","volume":"122","author":"Viegas","year":"2021","journal-title":"Fire Saf. J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"101370","DOI":"10.1016\/j.ijdrr.2019.101370","article-title":"Uncovering the perception regarding wildfires of residents with different characteristics","volume":"43","author":"Oliveira","year":"2020","journal-title":"Int. J. Disaster Risk Reduct."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1831","DOI":"10.1007\/s10694-019-00883-z","article-title":"Wildland\u2013Urban Interface Fires in Spain: Summary of the Policy Framework and Recommendations for Improvement","volume":"56","author":"Pastor","year":"2020","journal-title":"Fire Technol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"104588","DOI":"10.1016\/j.ssci.2019.104588","article-title":"Analysis of the impact of wildland-urban-interface fires on LPG domestic tanks","volume":"124","author":"Scarponi","year":"2020","journal-title":"Saf. Sci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.firesaf.2013.08.003","article-title":"Impact of a distant wildland fire on an LPG tank","volume":"61","author":"Heymes","year":"2013","journal-title":"Fire Saf. J."},{"key":"ref_8","unstructured":"(2022, March 02). O Instituto Portugu\u00eas do Mar e da Atmosfera, An\u00e1lise Preliminar do Per\u00edodo 5 a 10 Agosto 2016 na Madeira. Available online: https:\/\/www.ipma.pt\/pt\/media\/noticias\/news.detail.jsp?f=\/pt\/media\/noticias\/arquivo\/2016\/madeira-5-10-ago-2016.html."},{"key":"ref_9","unstructured":"Viegas, D.X., Figueiredo Almeida, M., Ribeiro, L.M., Raposo, J., Viegas, M.T., Oliveira, R., Pinto, C., Jorge, H., Rodrigues, A., and Lucas, D. (2017). O Complexo de Inc\u00eandios de Pedr\u00f3g\u00e3o Grande e Concelhos Lim\u00edtrofes, Iniciado a 17 de Junho de 2017, Centro de Estudos Sobre Inc\u00eandios Florestais (CEIF\/ADAI\/LAETA)."},{"key":"ref_10","unstructured":"Viegas, D.X., Almeida, M.A., Ribeiro, L.M., Raposo, J., Viegas, M.T., Oliveira, R., Alves, D., Pinto, C., Rodrigues, A., and Ribeiro, C. (2017). An\u00e1lise dos Inc\u00eandios Florestais Ocorridos a 15 de Outubro de 2017, Centro de Estudos Sobre Inc\u00eandios Florestais (CEIF\/ADAI\/LAETA)."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Pinto, P., Silva, \u00c1., Viegas, D., Almeida, M., Raposo, J., and Ribeiro, L. (2022). Influence of Convectively Driven Flows in the Course of a Large Fire in Portugal: The case of Prdr\u00f3g\u00e3o Grande. Atmosphere, 13.","DOI":"10.3390\/atmos13030414"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/j.psep.2017.01.007","article-title":"Comparative analysis of BLEVE mechanical energy and overpressure modeling","volume":"106","author":"Hemmatian","year":"2017","journal-title":"Process Saf. Environ. Prot."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.jlp.2004.08.002","article-title":"Calculating overpressure from BLEVE explosions","volume":"17","author":"Salla","year":"2004","journal-title":"J. Loss Prev. Process Ind."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1016\/j.jhazmat.2006.05.001","article-title":"Using liquid superheating energy for a quick estimation of overpressure in BLEVEs and similar explosions","volume":"137","author":"Casal","year":"2006","journal-title":"J. Hazard. Mater."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.jlp.2018.09.006","article-title":"Experimental investigation of consequences of LPG vehicle tank failure under fire conditions","volume":"56","author":"Tschirschwitz","year":"2018","journal-title":"J. Loss Prev. Process Ind."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1016\/j.firesaf.2017.05.006","article-title":"Mobile gas cylinders in fire: Consequences in case of failure","volume":"91","author":"Tschirschwitz","year":"2017","journal-title":"Fire Saf. J."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/S0304-3894(02)00198-X","article-title":"Experimental evaluation of LPG tank explosion hazards","volume":"96","author":"Stawczyk","year":"2003","journal-title":"J. Hazard. Mater."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/j.psep.2021.01.002","article-title":"Safety distances for storage tanks to prevent fire damage in Wildland-Industrial Interface","volume":"147","author":"Ricci","year":"2021","journal-title":"Process Saf. Environ. Prot."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s10694-020-00991-1","article-title":"Active Barrier Combining Fire-Resistant Fiberglass Fabric and Water Sprinkler System for Protection against Forest Fires","volume":"57","author":"Viegas","year":"2021","journal-title":"Fire Technol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"60","DOI":"10.3389\/fmech.2019.00060","article-title":"Whole-House Fire Blanket Protection from Wildland-Urban Interface Fires","volume":"5","author":"Takahashi","year":"2019","journal-title":"Front. Mech. Eng."},{"key":"ref_21","unstructured":"(2017). LPG Equipment and Accessories-Transportable Refillable Welded Steel Cylinders for LPG-Design and Construction (Standard No. EN 1442)."},{"key":"ref_22","unstructured":"(2011). Transportable Gas Cylinders-Fully Wrapped Composite Cylinders (Standard No. EN 12245:2009 + A1: 2011)."},{"key":"ref_23","unstructured":"Redmond, M., and Mastropietro, A.J. (2015, January 12\u201316). Thermophysical and Optical Properties of Materials Considered for use on the LDSD Test Vehicle. Proceedings of the 45th International Conference on Environmental Systems, Bellevue, WA, USA."},{"key":"ref_24","unstructured":"Batista, R.M. (2019). Mechanisms for Active Protection of People and Infrastructures against Forest Fires. [Ph.D. Dissertation, Universidade de Coimbra]. Available online: http:\/\/hdl.handle.net\/10316\/86026."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"122301","DOI":"10.1016\/j.ijheatmasstransfer.2021.122301","article-title":"Heat transfer model of fire protection fiberglass thermal barrier coated with thin aluminium layer","volume":"184","author":"Pereira","year":"2022","journal-title":"Int. J. Heat Mass Transf."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.firesaf.2016.11.004","article-title":"Fire whirls in forest fires: An experimental analysis","volume":"87","author":"Pinto","year":"2017","journal-title":"Fire Saf. J."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"S101","DOI":"10.1016\/j.foreco.2006.08.137","article-title":"Analysis of fire behaviour in Mediterranean shrubs: The Gestosa fire experiments (Portugal)","volume":"234","author":"Viegas","year":"2006","journal-title":"For. Ecol. Manag."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"41","DOI":"10.3389\/fmech.2019.00041","article-title":"Effect of Canyons on a Fire Propagating Laterally over Slopes","volume":"5","author":"Rodrigues","year":"2019","journal-title":"Front. Mech. Eng."},{"key":"ref_29","unstructured":"Raposo, J.R.N. (2016). Extreme Fire Behaviour Associated with the Merging of Two Linear Fire Fronts. [Ph.D. Dissertation, Coimbra University]."},{"key":"ref_30","unstructured":"Cohen, J.D., and Butler, B.W. (1996, January 27\u201331). Modeling potential structure ignitions from flame radiation exposure with implications for wildland\/urban interface fire management. Proceedings of the 13th Fire and Forest Meteorology Conference, International Association of Wildland Fire, Victoria, Australia. Available online: https:\/\/www.fs.fed.us\/rm\/pubs_other\/rmrs_1998_cohen_j001.pdf."},{"key":"ref_31","unstructured":"Cohen, J.D. (2022, March 20). The Structure Ignition Assessment Model (SIAM), The Biswell Symposium: Fire Issues and Solutions in Urban Interface and Wildland Ecosystems, Available online: https:\/\/www.fs.usda.gov\/treesearch\/pubs\/27418."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.jlp.2018.09.015","article-title":"LPG vessels exposed to fire: Scale effects on pressure build-up","volume":"56","author":"Scarponi","year":"2018","journal-title":"J. Loss Prev. Process Ind."},{"key":"ref_33","unstructured":"Poling, B.E., Prausnitz, J.M., and O\u2019Connell, J.P. (2001). The Properties of Gases and Liquids, McGraw-Hill."},{"key":"ref_34","unstructured":"(2022, April 07). National Institute of Standards and Technology, Saturation Properties for Propane\u2014Temperature Increments, (n.d.), Available online: https:\/\/webbook.nist.gov\/cgi\/fluid.cgi?Action=Load&ID=C74986&Type=SatP&Digits=5&THigh=60&TLow=0&TInc=1&RefState=DEF&TUnit=C&PUnit=bar&DUnit=kg%2Fm3&HUnit=kJ%2Fkg&WUnit=m%2Fs&VisUnit=uPa*s&STUnit=N%2Fm."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"3141","DOI":"10.1021\/je900217v","article-title":"Thermodynamic properties of propane. III. A reference equation of state for temperatures from the melting line to 650 K and pressures up to 1000 MPa","volume":"54","author":"Lemmon","year":"2009","journal-title":"J. Chem. Eng. Data"}],"container-title":["Fire"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2571-6255\/5\/3\/63\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:05:01Z","timestamp":1760137501000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2571-6255\/5\/3\/63"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,30]]},"references-count":35,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["fire5030063"],"URL":"https:\/\/doi.org\/10.3390\/fire5030063","relation":{},"ISSN":["2571-6255"],"issn-type":[{"value":"2571-6255","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,30]]}}}