{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T04:38:54Z","timestamp":1773290334016,"version":"3.50.1"},"reference-count":76,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2024,1,28]],"date-time":"2024-01-28T00:00:00Z","timestamp":1706400000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e Tecnologia","doi-asserted-by":"publisher","award":["PTDC\/ECI-CON\/2240\/2020"],"award-info":[{"award-number":["PTDC\/ECI-CON\/2240\/2020"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Fire"],"abstract":"<jats:p>This paper presents a study based on new fireproof design guidelines for dwellings against the impact of wildfires. The main objective is to present the results from the surveys of the large wildfires of 2017 in Portugal, identifying vulnerabilities in dwellings that may result in spot ignitions when exposed to wildfires. Utilizing the information gathered from these surveys, it is possible to recommend fire resistance and reaction class requirements using European indoor fire standards and adapting them to suit wildfire conditions. The study focuses on classical dwellings predominantly located in high-risk fire zones within the wildland\u2013urban interface. These assessments have the potential to generate new fireproof construction recommendations employing traditional materials commonly found in the European construction industry.<\/jats:p>","DOI":"10.3390\/fire7020040","type":"journal-article","created":{"date-parts":[[2024,1,29]],"date-time":"2024-01-29T12:25:01Z","timestamp":1706531101000},"page":"40","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Ignition Locations and Simplified Design Guidelines for Enhancing the Resilience of Dwellings against Wildland Fires"],"prefix":"10.3390","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4140-2204","authenticated-orcid":false,"given":"M\u00e1rio Rui Tiago","family":"Arruda","sequence":"first","affiliation":[{"name":"CERIS, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0683-3252","authenticated-orcid":false,"given":"Ant\u00f3nio Renato A.","family":"Bicelli","sequence":"additional","affiliation":[{"name":"CERIS, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal"}]},{"given":"Fernando","family":"Branco","sequence":"additional","affiliation":[{"name":"CERIS, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2024,1,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1890\/04-0545","article-title":"Federal forest-fire policy in the United States","volume":"15","author":"Stephens","year":"2005","journal-title":"Ecol. Appl."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1890\/04-1413","article-title":"The wildland\u2013urban interface in the United States","volume":"15","author":"Radeloff","year":"2005","journal-title":"Ecol. Appl."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1007\/BF02101922","article-title":"A new fire management policy on Forest Service lands","volume":"15","author":"Davis","year":"1979","journal-title":"Fire Technol."},{"key":"ref_4","unstructured":"Mueller, V. (2016). Examination of the Underlying Physics in a Detailed Wildland fire Behavior Model through Field-Scale Experimentation, University of Edinburgh."},{"key":"ref_5","unstructured":"Pyne, S.J., Andrews, P.L., and Laven, R.D. (1996). Introduction to Wildland Fire, John Wiley and Sons."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2690","DOI":"10.1111\/1365-2664.13972","article-title":"Effects of large herbivores on fire regimes and wildfire mitigation","volume":"58","author":"Moreira","year":"2021","journal-title":"J. Appl. Ecol."},{"key":"ref_7","first-page":"751","article-title":"Urban wildland interface communities within the vicinity of federal lands that are at high risk from wildfire","volume":"66","author":"Glickman","year":"2001","journal-title":"Fed. Regist."},{"key":"ref_8","first-page":"15","article-title":"Preventing Disaster: Home Ignitability in the Wildland-Urban Interface","volume":"98","author":"Cohen","year":"2000","journal-title":"J. For."},{"key":"ref_9","unstructured":"Feliciano, D., Alves, R., Mendes, A., Ribeiro, M., and Sottomayor, M. (2015). Forest Land Ownership Change in Portugal, European Forest Institute Central -East and South-East European Regional Office. COST Action FP1201 FACESMAP Country Report."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"13886","DOI":"10.1038\/s41598-019-50281-2","article-title":"Climate drivers of the 2017 devastating fires in Portugal","volume":"9","author":"Turco","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_11","unstructured":"Beighley, M., and Hyde, A.C. (2018). Portugal Wildfire Management in a New Era Assessing Fire Risks, Resources and Reforms, Instituto Superior de Agronomia, University of Lisbon."},{"key":"ref_12","unstructured":"Viegas, D.X., Almeida, M.F., and Ribeiro, L.M. (2017). O Complexo de Inc\u00eandios de Pedr\u00f3g\u00e3o Grande e Concelhos Lim\u00edtrofes, Iniciado a 17 de Junho de 2017, Universidade de Coimbra."},{"key":"ref_13","unstructured":"Guerreiro, J., Fonseca, C., Salgueiro, A., Fernandes, P., Lopez, I.E., Neufville, R., Mateus, F., Castellnou, R.M., Sande, S.J., and Moura, J.M. (2018). Avalia\u00e7\u00e3o dos Inc\u00eandios Ocorridos entre 14 e 16 de Outubro de 2017 em Portugal Continental, Assembleia da Rep\u00fablica."},{"key":"ref_14","unstructured":"(2018). Construction of Buildings in Bushfire Prone Areas (Standard No. AS3959)."},{"key":"ref_15","unstructured":"CBC (2016). California Building Code Part 2 Vol 1 and 2, California Building Standard Commission."},{"key":"ref_16","unstructured":"Thomas, J.C., Mueller, E.V., and Hadden, R.M. (2018). Advances in Forest Fire Research, Imprensa da Universidade de Coimbra."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Bicelli, A.R., Cantor, P., Arruda, M.R., Tiago, C., Bernardes de Assis, E., and Branco, F. (2023). Numerical Assessment of Standard Firebrand Accumulation Curve When Transferring Temperature to Contact Surfaces. Appl. Sci., 13.","DOI":"10.3390\/app13179657"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.firesaf.2018.10.002","article-title":"Thermal characterization of firebrand piles","volume":"104","author":"Hakes","year":"2019","journal-title":"Fire Saf. J."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"103037","DOI":"10.1016\/j.firesaf.2020.103037","article-title":"Localized heat transfer from firebrands to surfaces","volume":"120","author":"Bearinger","year":"2021","journal-title":"Fire Saf. J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"4757","DOI":"10.1016\/j.proci.2020.07.098","article-title":"Thermal dynamics of deposited firebrands using phosphor thermometry","volume":"38","author":"Bouvet","year":"2021","journal-title":"Proc. Combust. Inst."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"100935","DOI":"10.1016\/j.rineng.2023.100935","article-title":"Development of a standard firebrand accumulation temperature curve for residential wildfire protection system","volume":"17","author":"Cantor","year":"2023","journal-title":"Results Eng."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Ribeiro, L.M., Rodrigues, A., Lucas, D., and Viegas, D.X. (2020). The Impact on Structures of the Pedr\u00f3g\u00e3o Grande Fire Complex in June 2017 (Portugal). Fire, 3.","DOI":"10.3390\/fire3040057"},{"key":"ref_23","unstructured":"Laranjeira, J., and Cruz, H. (2024, January 01). Building Vulnerabilities to Fires at the Wildland Urban Interface. In Advances in Forest Fire Research. Available online: https:\/\/ucdigitalis.uc.pt\/pombalina\/item\/70253."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1071\/WF22095","article-title":"Relationships between building features and wildfire damage in California, USA and Pedr\u00f3g\u00e3o Grande, Portugal","volume":"32","author":"Dossi","year":"2023","journal-title":"Int. J. Wildland Fire"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Arruda, M., Tenreiro, T.C., and Branco, F. (2021). Rethinking Dwellings Protection for Wildland Fire. ASCE J. Perform. Constr., 35.","DOI":"10.1061\/(ASCE)CF.1943-5509.0001643"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"04022021","DOI":"10.1061\/(ASCE)HZ.2153-5515.0000706","article-title":"Proposal of Standard Wildfire Curves for the Design Protection of Dwellings against Wildland Fire","volume":"26","author":"Cantor","year":"2022","journal-title":"J. Hazard. Toxic Radioact. Waste"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.rcns.2023.10.002","article-title":"Proposal of a fireproof design code for dwellings against the action of wildland fires","volume":"2","author":"Arruda","year":"2023","journal-title":"Resilient Cities Struct."},{"key":"ref_28","unstructured":"Rep\u00fablica, A.d. (2021). Decreto Lei n.\u00b0 82\/2021 Estabelece o Sistema de Gest\u00e3o Integrada de Fogos Rurais no Territ\u00f3rio Continental e Define as suas regras de Funcionamento (Standard No. DL82\/2021)."},{"key":"ref_29","unstructured":"Tenreiro, T.C. (2018). Construction Techniques to Protect Houses From Wildland Fires, University of Lisbon, Instituto Superior T\u00e9cnico."},{"key":"ref_30","unstructured":"Rep\u00fablica, A.d. (2022). Despacho n.\u00b0 8591\/2022 Requisitos Para Ado\u00e7\u00e3o de Medidas de Prote\u00e7\u00e3o Relativas \u00e0 Resist\u00eancia do Edif\u00edcio \u00e0 Passagem do Fogo Florestal (Standard No. D8591\/2022)."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Ramsay, C., and Rudolph, L. (2003). Landscape and Building Design for Bushfire Areas, CSIRO Publishing.","DOI":"10.1071\/9780643090996"},{"key":"ref_32","unstructured":"Weir, I., and Davidson, J. (2011). Bushfire Lecture in the Landscape Architecture, Ian Weir Architec."},{"key":"ref_33","unstructured":"Wright, R. (2019). Suburban Wildfire Adaptation Roadmaps, Insurance Institute for Business & Home Safety."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"6378","DOI":"10.1038\/s41598-022-10479-3","article-title":"A wildfire vulnerability index for buildings","volume":"12","author":"Garlichs","year":"2022","journal-title":"Sci. Rep."},{"key":"ref_35","unstructured":"Westhaver, A. (2016). Why Some Homes Survived: Learning from the Fort McMurray Wildland\/Urban Interface Fire Disaster, Institute for Catastrophic Loss Reduction."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"022034","DOI":"10.1088\/1755-1315\/1101\/2\/022034","article-title":"Resilience of Industrial Buildings to Wildland-Urban Interface Fires","volume":"1101","author":"Lopes","year":"2022","journal-title":"IOP Conf. Ser. Earth Environ. Sci."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Vaz, G., Raposo, J., Reis, L., Monteiro, P., and Viegas, D. (2022). Rigid Protection System of Infrastructures against Forest Fires. Fire, 5.","DOI":"10.3390\/fire5050145"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1853","DOI":"10.1007\/s10694-019-00902-z","article-title":"Guidance on Design and Construction of the Built Environment Against Wildland Urban Interface Fire Hazard: A Review","volume":"56","author":"Intini","year":"2020","journal-title":"Fire Technol."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1016\/j.istruc.2023.01.126","article-title":"Evaluating the bushfire resistance of a safe room using full-scale experiments","volume":"49","author":"Hendawitharana","year":"2023","journal-title":"Structures"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"657","DOI":"10.3390\/civileng4020038","article-title":"Report on Existing Fireproof Construction Guidelines for Dwellings against Wildfires","volume":"4","author":"Cantor","year":"2023","journal-title":"CivilEng"},{"key":"ref_41","unstructured":"(2018). Methods for Fire Tests on Building Materials, Components and Structures, Part 8.1: Tests on Elements of Construction for Buildings Exposed to Simulated Bushfire Attack\u2014Radiant Heat and Small Flaming Sources (Standard No. AS-1530-8-1)."},{"key":"ref_42","unstructured":"(2018). Methods for Fire Tests on Building Materials, Components and Structures, Part 8.1: Tests on Elements of Construction for Buildings Exposed to Simulated Bushfire Attack\u2014Large Flaming Sources (Standard No. AS-1530-8-2)."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1903","DOI":"10.1007\/s10694-020-00999-7","article-title":"Regulatory Controls for Buildings in Wildfire-Prone Areas of Australia","volume":"56","author":"Baker","year":"2020","journal-title":"Fire Technol."},{"key":"ref_44","unstructured":"(2016). California Code of Regulations Title 24\u2014Chapter 12-7A-2 Materials and Construction Methods for Exterior Wildfire Exposure, Exterior Windows (Standard No. SFM-12-7A-2)."},{"key":"ref_45","unstructured":"(2016). California Code of Regulations Title 24\u2014Chapter 12-7A-1 Materials and Construction Methods for Exterior Wildfire Exposure, Exterior Wall Siding and Sheathing (Standard No. SFM-12-7A-1)."},{"key":"ref_46","unstructured":"(2016). California Code of Regulations Title 24\u2014Chapter 12-7A-4 Materials and Construction Methods for Exterior Wildfire Exposure, Decking (Standard No. SFM-12-7A-4)."},{"key":"ref_47","first-page":"104","article-title":"Implementation of a Vulnerability Assessment Tool for Properties at the Wildland-Urban Interface Based on Real Case Studies","volume":"17","author":"Vacca","year":"2022","journal-title":"Environ. Sci. Proc."},{"key":"ref_48","first-page":"1011","article-title":"Evaluating wildfire vulnerability of Mediterranean dwellings using fuzzy logic applied to expert judgement","volume":"32","author":"Vacca","year":"2023","journal-title":"Int. J. Wildland Fire"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"103853","DOI":"10.1016\/j.firesaf.2023.103853","article-title":"Methodology for the analysis of structural vulnerability of WUI settlements","volume":"140","author":"Vacca","year":"2023","journal-title":"Fire Saf. J."},{"key":"ref_50","unstructured":"\u00c0gueda, A., Vacca, P., Planas, E., and Pastor, E. (2024, January 01). Using Fuzzy Logic to Evaluate Fire Vulnerability of Dwellings Located at the Wildland-Urban Interface. Available online: http:\/\/books.uc.pt\/chapter?chapter=9789892622989122."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Louren\u00e7o, L. (2018). Forest fires in continental Portugal Result of profound alterations in society and territorial consequences. J. M\u00e9diterran\u00e9e Geogr., 130.","DOI":"10.4000\/mediterranee.9958"},{"key":"ref_52","unstructured":"(2015). Fire resistance Tests for Non-Loadbearing Elements (Standard No. EN1364-3-4-5-6)."},{"key":"ref_53","unstructured":"(2009). Fire Classification of Construction Products and Building Elements\u2014Part 1: Classification Using Data from Reaction to Fire Tests (Standard No. EN13501-1)."},{"key":"ref_54","unstructured":"Tenreiro, T.C., Branco, F.A., and Arruda, M.R.T. (2020, January 24\u201327). Rethinking Houses for Wildland Fires Protection. Proceedings of the Euro-American Congress REHABEND 2020, Granada, Spain."},{"key":"ref_55","unstructured":"Bisby, L.A. (2003). Fire Behaviour of Fibre-Reinforced Polymer (FRP) Reinforced or Confined Concrete, Queen\u2019s University."},{"key":"ref_56","unstructured":"Williams, B.K. (2003). Fire Performance of FRP-Strengthened Reinforced Concrete Flexural Members, Queen\u2019s University."},{"key":"ref_57","unstructured":"Schaffer, E.L. (1984). Structural Fire Design: Wood, United States Department of Agriculture."},{"key":"ref_58","unstructured":"Minist\u00e9rio das Obras P\u00fablicas, T.e.C. (2006). Decreto-Lei n.\u00b0 80\/2006 Regulamento das Caracter\u00edsticas de Comportamento T\u00e9rmico dos Edif\u00edcios (RCCTE) (Standard No. DL80\/2006)."},{"key":"ref_59","unstructured":"(2024, January 01). ISO-834. Available online: https:\/\/www.iso.org\/standard\/75137.html."},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"Kodur, V.K.R., and Pakala, P. (2010, January 12\u201315). Energy Based Time Equivalent Approach for Evaluating Fire Resistance under Design Fire Exposures. Proceedings of the Structures Congress ASCE, Orlando, FL, USA.","DOI":"10.1061\/41130(369)117"},{"key":"ref_61","unstructured":"Ingberg, S.H. (1922). Lessons from Fire Tests; Reviews results of fire tests and their application to fire resistive constructions."},{"key":"ref_62","first-page":"43","article-title":"Test of the Severity of Building Fires","volume":"22","author":"Ingberg","year":"1928","journal-title":"NFPA Q."},{"key":"ref_63","unstructured":"Wessies, S.S. (2021). Firebrand Ignition\u2014Characterization of Heat Transfer Mechanisms, University of Texas at Austin, UT Fire Research Group."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.firesaf.2010.03.002","article-title":"Energy based time equivalent approach for evaluating fire resistance of reinforced concrete beams","volume":"45","author":"Kodur","year":"2010","journal-title":"Fire Saf. J."},{"key":"ref_65","unstructured":"(2002). Eurocode 1: Actions on Structures\u2014Part 1-2: General Actions\u2014Actions of Structures Exposed to Fire (Standard No. EC1-1-2)."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1007\/s10694-016-0589-z","article-title":"Review of Pathways for Building Fire Spread in the Wildland Urban Interface Part I: Exposure Conditions","volume":"53","author":"Caton","year":"2017","journal-title":"Fire Technol."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.firesaf.2008.01.001","article-title":"Establishing safety distances for wildland fires","volume":"43","author":"Arnaldos","year":"2008","journal-title":"Fire Saf. J."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"2063","DOI":"10.1139\/x06-185","article-title":"Crown fire behaviour in a northern jack pine\u2014Black spruce forest","volume":"36","author":"Stocks","year":"2006","journal-title":"Can. J. For. Res."},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Fayad, J., Accary, G., Morandini, F., Chatelon, F.-J., Rossi, L., Marcelli, T., Cancellieri, D., Cancellieri, V., Rahib, Y., and Morvan, D. (2023). Numerical Assessment of Safe Separation Distance in the Wildland\u2013Urban Interfaces. Fire, 6.","DOI":"10.3390\/fire6050209"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/j.psep.2021.01.002","article-title":"Safety distances for storage tanks to prevent fire damage in Wildland-Industrial Interface","volume":"147","author":"Ricci","year":"2021","journal-title":"Process Saf. Environ. Prot."},{"key":"ref_71","unstructured":"Arruda, M.R.T., Cantor, P., Bicelli, A.R.A., and Branco, F. (2023). Thermal Reaction of Firebrand Accumulation in Construction Materials. Case Stud. Constr. Mater., Available online: https:\/\/whp.tecnico.ulisboa.pt\/publications.htm."},{"key":"ref_72","unstructured":"(2009). Fire Classification of Construction Products and Building Elements\u2014Part 2: Classification Using Data from Fire Resistance Tests, excluding Ventilation Services (Standard No. EN 13501-2)."},{"key":"ref_73","unstructured":"(2016). Fire Classification of Construction Products and Building Elements\u2014Part 5: Classification Using Data from External Fire Exposure to Roofs Tests (Standard No. EN13501-5)."},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Manzello, S.L. (2020). Encyclopedia of Wildfires and Wildland-Urban Interface (WUI) Fires, Springer.","DOI":"10.1007\/978-3-319-51727-8"},{"key":"ref_75","doi-asserted-by":"crossref","unstructured":"Fiorini, C., Craveiro, H.D., Santiago, A., La\u00edm, L., and Sim\u00f5es da Silva, L. (2023). Parametric evaluation of heat transfer mechanisms in a WUI fire scenario. Int. J. Wildland Fire, 32.","DOI":"10.1071\/WF22157"},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Craveiro, H.D., Fiorini, C., La\u00edm, L., Guillaume, B., and Santiago, A. (2023). Experimental and Numerical Evaluation of a Wildland\u2013Urban Interface Fire Scenario. Appl. Sci., 13.","DOI":"10.3390\/app132413236"}],"container-title":["Fire"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2571-6255\/7\/2\/40\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T13:50:41Z","timestamp":1760104241000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2571-6255\/7\/2\/40"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,28]]},"references-count":76,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,2]]}},"alternative-id":["fire7020040"],"URL":"https:\/\/doi.org\/10.3390\/fire7020040","relation":{},"ISSN":["2571-6255"],"issn-type":[{"value":"2571-6255","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,28]]}}}