{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T00:57:31Z","timestamp":1760057851891,"version":"build-2065373602"},"reference-count":29,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T00:00:00Z","timestamp":1740441600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001871","name":"the CONSTRUCT\u2014Instituto de I&amp;D em Estruturas e Constru\u00e7\u00f5es","doi-asserted-by":"publisher","award":["UIDB\/04708\/2020"],"award-info":[{"award-number":["UIDB\/04708\/2020"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Infrastructures"],"abstract":"<jats:p>The accurate thermal performance assessment of building components is critical for improving energy efficiency in buildings, mainly as space climatization accounts for a large percentage of energy consumption. The literature review points out multiple parameters that influence the measurement of the U-value using the HFM method. However, most of these studies are focused on in situ tests and little information exists on the variability of the results of the hot box method to assess thermal resistance. According to EN 1934, a baffle must be positioned between the surface of the specimen and the fans of the climatic chamber to maintain acceptable air temperature gradients and uniform air temperature distribution to minimize the convective effects. However, no clear information about its position is given. This study investigates the variability in the measurement of the thermal resistance of double leaf brick wall specimen using the hot box method, focusing on the effect of the layout configuration. An experimental campaign was carried out and three configurations were considered: no baffle, a baffle positioned 1.15 m from the wall, and a baffle positioned 0.05 m from the specimen. The experimental results demonstrate that baffle positioning significantly influences measurement variability. The best-performing configuration (P1) resulted in the lowest variability and the closest agreement with theoretical values, with an average R-value deviation of approximately 25%. These findings are relevant for optimizing testing protocols and improving the reliability of thermal resistance assessments. Furthermore, the results have implications for energy efficiency policies and building retrofitting strategies, aligning with global sustainability goals to reduce building energy demand and carbon emissions.<\/jats:p>","DOI":"10.3390\/infrastructures10030048","type":"journal-article","created":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T03:40:12Z","timestamp":1740454812000},"page":"48","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Variability of the Hot Box Method in Assessing Thermal Resistance of a Double Leaf Brick Wall"],"prefix":"10.3390","volume":"10","author":[{"given":"Manuel","family":"Ribas","sequence":"first","affiliation":[{"name":"CONSTRUCT-LFC, Departamento de Engenharia Civil, Faculdade de Engenharia (FEUP), Universidade do Porto, Rua Dr. Roberto Frias, s\/n, 4200-465 Porto, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1343-5578","authenticated-orcid":false,"given":"Eva","family":"Barreira","sequence":"additional","affiliation":[{"name":"CONSTRUCT-LFC, Departamento de Engenharia Civil, Faculdade de Engenharia (FEUP), Universidade do Porto, Rua Dr. Roberto Frias, s\/n, 4200-465 Porto, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9846-6081","authenticated-orcid":false,"given":"Ricardo M. S. F.","family":"Almeida","sequence":"additional","affiliation":[{"name":"CONSTRUCT-LFC, Departamento de Engenharia Civil, Faculdade de Engenharia (FEUP), Universidade do Porto, Rua Dr. Roberto Frias, s\/n, 4200-465 Porto, Portugal"},{"name":"Departamento de Engenharia Civil, Instituto Polit\u00e9cnico de Viseu, Campus Polit\u00e9cnico, 3504-510 Viseu, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2025,2,25]]},"reference":[{"key":"ref_1","unstructured":"(2025, January 20). European Environment Agency (EEA). Available online: https:\/\/www.eea.europa.eu\/en."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.econmod.2020.05.001","article-title":"Air conditioning and electricity expenditure: The role of climate in temperate countries","volume":"90","author":"Randazzo","year":"2020","journal-title":"Econ. Model."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"112198","DOI":"10.1016\/j.enbuild.2022.112198","article-title":"Projected global demand for air conditioning associated with extreme heat and implications for electricity grids in poorer countries","volume":"268","author":"Sherman","year":"2022","journal-title":"Energy Build."},{"key":"ref_4","unstructured":"Bouckaert, S., Pales, A.F., McGlade, C., Remme, U., Wanner, B., Varro, L., and Spencer, T. (2021). Net Zero by 2050: A Roadmap for the Global Energy Secto, International Energy Agency."},{"key":"ref_5","unstructured":"(2014). Thermal Insulation-Building Elements-In-Situ Measurement of Thermal Resistance and Thermal Transmittance. Part 1: Heat Flow Meter Method (Standard No. ISO Standard 9869-1:2014)."},{"key":"ref_6","unstructured":"(1999). Thermal Performance of Buildings\u2014Determination of Thermal Resistance by Hot Box Method Using Heat Flow Meter\u2014Masonry (Standard No. EN 1934)."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.autcon.2014.02.009","article-title":"The gap between predicted and measured energy performance of buildings: A framework for investigation","volume":"41","year":"2014","journal-title":"Autom. Constr."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1016\/j.enbuild.2016.08.072","article-title":"A comparison of standardized calculation methods for in situ measurements of fa\u00e7ades U-value","volume":"130","author":"Gaspar","year":"2016","journal-title":"Energy Build."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Lee, Y.-J., Moon, J.-H., Choi, D.-S., and Ko, M.-J. (2024). Application of the Heat Flow Meter Method and Extended Average Method to Improve the Accuracy of In Situ U-Value Estimations of Highly Insulated Building Walls. Sustainability, 16.","DOI":"10.3390\/su16135687"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.applthermaleng.2015.03.010","article-title":"Feasibility experiment on the simple hot box-heat flow meter method and the optimization based on simulation reproduction","volume":"83","author":"Meng","year":"2015","journal-title":"Appl. Therm. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/0360-1323(86)90007-7","article-title":"Measurement errors with surface-mounted heat flux sensors","volume":"21","author":"Trethowen","year":"1986","journal-title":"Build. Environ."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1016\/j.enbuild.2014.11.005","article-title":"Factors affecting the in-situ measurement accuracy of the wall heat transfer coefficient using the heat flow meter method","volume":"86","author":"Meng","year":"2015","journal-title":"Energy Build."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.enbuild.2012.08.036","article-title":"A measuring campaign of thermal conductance in situ and possible impacts on net energy demand in buildings","volume":"59","author":"Cesaratto","year":"2013","journal-title":"Energy Build."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Gaspar, K., Casals, M., and Gangolells, M. (2021). Influence of HFM thermal contact on the accuracy of in situ measurements of fa\u00e7ades\u2019 U-value in operational stage. Appl. Sci., 11.","DOI":"10.3390\/app11030979"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Lee, Y.-J., Moon, J.-H., Choi, D.-S., and Ko, M.-J. (2024). Influences of Average Temperature Difference and Measurement Period on Estimation of In Situ Thermal Transmittance of Building Exterior Walls Using the Average Method of ISO 9869-1. Energies, 17.","DOI":"10.3390\/en17051177"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.enbuild.2018.04.012","article-title":"In situ measurement of fa\u00e7ades with a low U-value: Avoiding deviations","volume":"170","author":"Gaspar","year":"2018","journal-title":"Energy Build."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2613","DOI":"10.1016\/j.enbuild.2011.05.025","article-title":"Comparing different approaches to in situ measurement of building components thermal resistance","volume":"43","author":"Desogus","year":"2011","journal-title":"Energy Build."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.enbuild.2015.06.071","article-title":"U-value in situ measurement for energy diagnosis of existing buildings","volume":"104","author":"Ficco","year":"2015","journal-title":"Energy Build."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.buildenv.2015.07.033","article-title":"Thermal performance of a selection of insulation materials suitable for historic buildings","volume":"94","author":"Walker","year":"2015","journal-title":"Build. Environ."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1792","DOI":"10.1016\/j.enbuild.2011.03.021","article-title":"Effect of different parameters on the in situ thermal conductance evaluation","volume":"43","author":"Cesaratto","year":"2011","journal-title":"Energy Build."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.enbuild.2014.07.048","article-title":"In situ measurement of thermal transmittance and thermal resistance of hollow reinforced precast concrete walls","volume":"84","author":"Ahmad","year":"2014","journal-title":"Energy Build."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2076","DOI":"10.1016\/j.enbuild.2008.05.012","article-title":"In situ measuring and evaluating the thermal resistance of building construction","volume":"40","author":"Peng","year":"2008","journal-title":"Energy Build."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.enbuild.2015.07.049","article-title":"Hygrothermal performance evaluation of traditional brick masonry in historic buildings","volume":"105","author":"Litti","year":"2015","journal-title":"Energy Build."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.1016\/j.enbuild.2010.04.007","article-title":"A data analysis method for detecting wall thermal resistance considering wind velocity in situ","volume":"42","author":"Wang","year":"2010","journal-title":"Energy Build."},{"key":"ref_25","unstructured":"(2024). Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus (Standard No. ASTM C1363-19)."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Alhawari, A., and Mukhopadhyaya, P. (2022). Construction and Calibration of a Unique Hot Box Apparatus. Energies, 15.","DOI":"10.3390\/en15134677"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2189","DOI":"10.1016\/j.conbuildmat.2008.12.006","article-title":"Properties of thermal insulation materials during extreme environment changes","volume":"23","author":"Enochsson","year":"2009","journal-title":"Constr. Build. Mater."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.enbuild.2018.10.021","article-title":"Laboratory and in-situ non-destructive methods to evaluate the thermal transmittance and behavior of walls, windows, and construction elements with innovative materials: A review","volume":"182","author":"Soares","year":"2019","journal-title":"Energy Build."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"111342","DOI":"10.1016\/j.enbuild.2021.111342","article-title":"Evaluating dynamic thermal performance of building envelope components using small-scale calibrated hot box tests","volume":"251","author":"Shen","year":"2021","journal-title":"Energy Build."}],"container-title":["Infrastructures"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2412-3811\/10\/3\/48\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:41:47Z","timestamp":1760028107000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2412-3811\/10\/3\/48"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,25]]},"references-count":29,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,3]]}},"alternative-id":["infrastructures10030048"],"URL":"https:\/\/doi.org\/10.3390\/infrastructures10030048","relation":{},"ISSN":["2412-3811"],"issn-type":[{"type":"electronic","value":"2412-3811"}],"subject":[],"published":{"date-parts":[[2025,2,25]]}}}