{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:46:04Z","timestamp":1760132764764,"version":"build-2065373602"},"publisher-location":"Basel Switzerland","reference-count":13,"publisher":"MDPI","license":[{"start":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T00:00:00Z","timestamp":1698105600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"European Regional Development Fund (ERDF) and the National Science and Technology Foundation (FCT)","award":["SAICT-ALG\/39586\/2018"],"award-info":[{"award-number":["SAICT-ALG\/39586\/2018"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"DOI":"10.3390\/iocbd2023-15209","type":"proceedings-article","created":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T11:30:54Z","timestamp":1700479854000},"page":"24","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Design, Environment, Energy, and Comfort in Buildings Equipped with a PMV-Controlled HVAC System"],"prefix":"10.3390","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5963-2107","authenticated-orcid":false,"given":"Eus\u00e9bio","family":"Concei\u00e7\u00e3o","sequence":"first","affiliation":[{"name":"Faculdade de Ci\u00eancias e Tecnologia, Universidade do Algarve, Campus de Gambelas, 8005-139 Faro, Portugal"}]},{"given":"Margarida","family":"Concei\u00e7\u00e3o","sequence":"additional","affiliation":[{"name":"Instituto Superior T\u00e9cnico, Universidade de Lisboa, 8005-139 Faro, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5322-8875","authenticated-orcid":false,"given":"Maria In\u00eas","family":"Concei\u00e7\u00e3o","sequence":"additional","affiliation":[{"name":"Instituto Superior T\u00e9cnico, Universidade de Lisboa, 8005-139 Faro, Portugal"}]},{"given":"Maria Manuela","family":"L\u00facio","sequence":"additional","affiliation":[{"name":"Faculdade de Ci\u00eancias e Tecnologia, Universidade do Algarve, Campus de Gambelas, 8005-139 Faro, Portugal"}]},{"given":"Hazim","family":"Awbi","sequence":"additional","affiliation":[{"name":"School of Built Environment, University of Reading, Reading RG6 6AW, UK"}]}],"member":"1968","published-online":{"date-parts":[[2023,10,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1016\/j.buildenv.2008.06.015","article-title":"Development of a temperature control model used in HVAC systems in school spaces in Mediterranean climate","volume":"44","author":"Ruano","year":"2009","journal-title":"Build. Environ."},{"key":"ref_2","unstructured":"Fanger, P.O. (1970). Analysis and Applications in Environmental Engineering, Danish Technical Press."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1080\/10789669.1997.10391380","article-title":"Airflow around a passenger seated in a bus","volume":"3","author":"Silva","year":"1997","journal-title":"HVAC R Res."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Concei\u00e7\u00e3o, E.Z.E., and Awbi, H. (2021). Evaluation of integral effect of thermal comfort, air quality and draught risk for desks equipped with personalized ventilation systems. Energies, 14.","DOI":"10.3390\/en14113235"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.apergo.2014.11.013","article-title":"Evaluation of thermal comfort in university classrooms through objective approach and subjective preference analysis","volume":"48","author":"Nico","year":"2015","journal-title":"Appl. Ergon."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1016\/S0378-7788(02)00003-8","article-title":"Extension of the PMV model to non-air-conditioned buildings in warm climates","volume":"34","author":"Fanger","year":"2002","journal-title":"Energy Build."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.buildenv.2013.07.002","article-title":"Thermal comfort evaluation in kindergarten: PMV and PPD measurement through datalogger and questionnaire","volume":"68","author":"Fabbri","year":"2013","journal-title":"Build. Environ."},{"key":"ref_8","unstructured":"(2005). Ergonomics of the Thermal Environment Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria (Standard No. ISO 7730)."},{"key":"ref_9","unstructured":"(2017). Thermal Environmental Conditions for Human Occupancy (Standard No. ANSI\/ASHRAE Standard 55-2017)."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Concei\u00e7\u00e3o, E.Z.E., Gomes, J., and Awbi, H. (2019). Influence of the airflow in a solar passive building on the indoor air quality and thermal comfort levels. Atmosphere, 10.","DOI":"10.3390\/atmos10120766"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.enbuild.2015.02.049","article-title":"Application of sunspaces in fostering energy efficiency and economical viability of residential buildings in Serbia","volume":"98","author":"Kavran","year":"2015","journal-title":"Energy Build."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.enbuild.2017.04.034","article-title":"Experimental monitoring of a sunspace applied to a NZEB mock-up: Assessing and comparing the energy benefits of different configurations","volume":"152","author":"Ulpiani","year":"2017","journal-title":"Energy Build."},{"key":"ref_13","unstructured":"(1990). Ventilation for Acceptable Indoor Air Quality (Standard No. ASHRAE Standard 62-1989)."}],"event":{"name":"International Online Conference on Buildings","acronym":"IOCBD 2023"},"container-title":["IOCBD 2023"],"original-title":[],"link":[{"URL":"https:\/\/www.mdpi.com\/2673-4591\/53\/1\/24\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:26:18Z","timestamp":1760131578000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2673-4591\/53\/1\/24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,24]]},"references-count":13,"alternative-id":["IOCBD2023-15209"],"URL":"https:\/\/doi.org\/10.3390\/iocbd2023-15209","relation":{},"subject":[],"published":{"date-parts":[[2023,10,24]]}}}