{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T18:44:54Z","timestamp":1790880294705,"version":"4.1.0"},"reference-count":32,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2018,3,30]],"date-time":"2018-03-30T00:00:00Z","timestamp":1522368000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>A research investigation of \u201cant nest\u201d corrosion (ANC) on copper tube was conducted in terms of the variables of the corrosion potential and pH value in 103 ppm copper formate solution over 20 days. The paper presents the surface and cross-sectional observations and examines Cu2O and H2O as the stable chemical species produced. A Cannizzaro reaction as a disproportionation reaction from formic acid and a comproportionation reaction from the metallic copper tube and copper formate solution critically influenced the ANC mechanism. The paper also categorizes the ANC attack as a rapid reaction system from the electrochemical point of view by using a polarization resistance curve.<\/jats:p>","DOI":"10.3390\/ma11040533","type":"journal-article","created":{"date-parts":[[2018,3,30]],"date-time":"2018-03-30T12:43:48Z","timestamp":1522413828000},"page":"533","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Investigating the Mechanism behind \u2018Ant Nest\u2019 Corrosion on Copper Tube"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9878-5202","authenticated-orcid":false,"given":"Riky","family":"Situmorang","sequence":"first","affiliation":[{"name":"Division of Engineering, Muroran Institute of Technology, 27-1, Mizumoto-cho, Muroran, Hokkaido 050-8585, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideki","family":"Kawai","sequence":"additional","affiliation":[{"name":"Database Researcher of Department of Mechanical System Engineering, Muroran Institute of Technology, 27-1, Mizumoto-cho, Muroran, Hokkaido 050-8585, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2018,3,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3116","DOI":"10.3390\/su5073116","article-title":"Sustainability challenges from climate change and air conditioning use in urban areas","volume":"5","author":"Lundgren","year":"2013","journal-title":"Sustainability"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"367","DOI":"10.3989\/revmetalm.2006.v42.i5.34","article-title":"Ant-nest corrosion of copper tubing in air-conditioning units","volume":"42","author":"Bastidas","year":"2006","journal-title":"Rev. Metal."},{"key":"ref_3","first-page":"56","article-title":"Copper corrosion in air-conditioning systems","volume":"52","author":"Cano","year":"2005","journal-title":"Corros. Prev. Control"},{"key":"ref_4","unstructured":"Elliott, P., and Corbett, R.A. (1999). CORROSION\/99, NACE International. Paper Number 99342."},{"key":"ref_5","unstructured":"Corbett, R.A., and Elliott, P. (2000). CORROSION\/2000, NACE International. Paper Number 00646."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.engfailanal.2013.11.014","article-title":"Failure analysis of copper tube used in a refrigerating plant","volume":"37","author":"Chandra","year":"2014","journal-title":"Eng. Fail. Anal."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.engfailanal.2017.09.013","article-title":"Interactive effect of ant nest corrosion and stress corrosion on the failure of copper tubes","volume":"83","author":"Zhou","year":"2018","journal-title":"Eng. Fail. Anal."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.engfailanal.2015.02.016","article-title":"Failure analysis of a copper tube in a finned heat exchanger","volume":"51","author":"Peltola","year":"2015","journal-title":"Eng. Fail. Anal."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"5962","DOI":"10.1073\/pnas.1423558112","article-title":"Contribution of air conditioning adoption to future energy use under global warming","volume":"112","author":"Davis","year":"2015","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_10","first-page":"18","article-title":"Early Corrosion Failures in Copper Heat Exchanger Tubing","volume":"16","author":"Edwards","year":"1977","journal-title":"Mater. Perform."},{"key":"ref_11","unstructured":"Miya, K. (2011, January 28\u201330). Quantitative evaluation of progress rate of Ant nest corrosion for Phosphorous deoxidized copper and oxygen-free copper. In Proceeding of the 58th Japan Conference on Materials and Environments (JSCE 2011), Nagoya, Japan. (In Japanese)."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"4140","DOI":"10.1149\/1.1838928","article-title":"A laboratory study of the effect of acetic acid vapor on atmospheric copper corrosion","volume":"145","author":"Cano","year":"1998","journal-title":"J. Electrochem. Soc."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1002\/(SICI)1521-4176(199902)50:2<103::AID-MACO103>3.0.CO;2-B","article-title":"Early corrosion failure of copper tubing used in air-conditioning units","volume":"50","author":"Cano","year":"1999","journal-title":"Mater. Corros."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"462","DOI":"10.3323\/jcorr.65.462","article-title":"Corrosion Behavior of Phosphorous Deoxidized Copper Tubes in Copper (II) Formate and Copper (II) Acetate Solution","volume":"65","author":"Sakai","year":"2016","journal-title":"Corros. Eng. Jpn."},{"key":"ref_15","unstructured":"Brillas, E. (2004). Localized \u201cant\u2019s nest\u201d corrosion in copper tubes and its prevention. Trends in Electrochemistry and Corrosion at the Beginning of 21st Century, Edicions Universtat de Barcelona."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"233","DOI":"10.3323\/jcorr1991.44.233","article-title":"Localized corrosion of copper in wet organic acid vapor","volume":"44","author":"Baba","year":"1995","journal-title":"Corros. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1149\/1.1393303","article-title":"Copper corrosion mechanism in the presence of formic acid vapor for short exposure times","volume":"147","author":"Bastidas","year":"2000","journal-title":"J. Electrochem. Soc."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"389","DOI":"10.3323\/jcorr.61.389","article-title":"Ant\u2019s Nest Corrosion on Copper Tube in Formic Acid Solution","volume":"61","author":"Sakai","year":"2012","journal-title":"Corros. Eng. Jpn."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.engfailanal.2012.07.006","article-title":"A microstructural aspect of intergranular stress corrosion cracking of semi-hard U-bend tubes of commercially pure copper in cooling systems","volume":"26","author":"Miyamoto","year":"2012","journal-title":"Eng. Fail. Anal."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3905","DOI":"10.1016\/j.corsci.2007.05.014","article-title":"Intergranular stress corrosion cracking of copper\u2014A case study","volume":"49","author":"Kuznicka","year":"2007","journal-title":"Corros. Sci."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"341","DOI":"10.3323\/jcorr.65.341","article-title":"Ant Nest Corrosion Developed on Phosphorus Deoxidized and Oxygen-Free Copper Tube","volume":"65","author":"Sakai","year":"2016","journal-title":"Corros. Eng. Jpn."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"505","DOI":"10.3323\/jcorr.65.505","article-title":"Development of Zinc Plating Treatment Copper Tube to Ant\u2019s Nest Corrosion","volume":"65","author":"Ueda","year":"2016","journal-title":"Corros. Eng. Jpn."},{"key":"ref_23","first-page":"135","article-title":"Development of Surface Treatment on Copper Tube for Prevention of Ant\u2019s Nest-like Corrosion","volume":"55","author":"Kiyokawa","year":"2016","journal-title":"J. Jpn. Inst. Copp. Tube"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1007\/BF00728041","article-title":"Localized corrosion in copper tubes and the effect of anti-tarnishing pretreatment","volume":"10","author":"Notoya","year":"1991","journal-title":"J. Mater. Sci. Lett."},{"key":"ref_25","first-page":"21","article-title":"Ant\u2019s Nest-Like Pitting Attack on Copper Tubes ans Its Analysis","volume":"65","author":"Seri","year":"2016","journal-title":"Corros. Eng. Jpn."},{"key":"ref_26","first-page":"37","article-title":"Fight formicary corrosion","volume":"68","author":"Elliott","year":"2005","journal-title":"Chem. Process"},{"key":"ref_27","first-page":"147","article-title":"Effect of Copper Formate on Ant\u2019s Nest-like pitting Attacks on Copper Tube","volume":"56","author":"Takashi","year":"2017","journal-title":"J. Jpn. Inst. Copp."},{"key":"ref_28","unstructured":"Pourbaix, M. (1966). Atlas of Electrochemical Equiliberia in Aqueous Solution, Pergamon Press."},{"key":"ref_29","first-page":"154","article-title":"The NBS Table of Chemical Thermodynamic properties","volume":"11","author":"Wagman","year":"1982","journal-title":"J. Phys. Chem. Ref. Data"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"510","DOI":"10.3323\/jcorr.65.510","article-title":"Effect of Dissolved Oxygen on Corrosion behavior of Phosphorous Deoxidized Copper Tube in Formic Acid Solution","volume":"65","author":"Sakai","year":"2016","journal-title":"Corros. Eng. Jpn."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.electacta.2016.08.017","article-title":"Differentiating polarization curve technique for determining the exchange current density of hydrogen electrode reaction","volume":"218","author":"Seri","year":"2016","journal-title":"Electrochim. Acta"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Seri, O., and Siree, B. (2017). The Differentiating Polarization Curve Technique for the Tafel Parameter Estimation. Catalysts, 7.","DOI":"10.3390\/catal7080239"}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/11\/4\/533\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T14:59:08Z","timestamp":1760194748000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/11\/4\/533"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,30]]},"references-count":32,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2018,4]]}},"alternative-id":["ma11040533"],"URL":"https:\/\/doi.org\/10.3390\/ma11040533","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,30]]}}}