{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T04:50:07Z","timestamp":1774414207807,"version":"3.50.1"},"reference-count":72,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2022,1,14]],"date-time":"2022-01-14T00:00:00Z","timestamp":1642118400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"European Regional Development Fund (ERDF)","award":["POCI-01-0145-FEDER-028261"],"award-info":[{"award-number":["POCI-01-0145-FEDER-028261"]}]},{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e Tecnologia","doi-asserted-by":"publisher","award":["POCI-01-0145-FEDER-028261"],"award-info":[{"award-number":["POCI-01-0145-FEDER-028261"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e Tecnologia","doi-asserted-by":"publisher","award":["UIDB\/04539\/2020"],"award-info":[{"award-number":["UIDB\/04539\/2020"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Molecules"],"abstract":"<jats:p>Direct in vivo measurements of neurometabolic markers in the brain with high spatio-temporal resolution, sensitivity, and selectivity is highly important to understand neurometabolism. Electrochemical biosensors based on microelectrodes are very attractive analytical tools for continuous monitoring of neurometabolic markers, such as lactate and glucose in the brain extracellular space at resting and following neuronal activation. Here, we assess the merits of a platinized carbon fiber microelectrode (CFM\/Pt) as a sensing platform for developing enzyme oxidase-based microbiosensors to measure extracellular lactate in the brain. Lactate oxidase was immobilized on the CFM\/Pt surface by crosslinking with glutaraldehyde. The CFM\/Pt-based lactate microbiosensor exhibited high sensitivity and selectivity, good operational stability, and low dependence on oxygen, temperature, and pH. An array consisting of a glucose and lactate microbiosensors, including a null sensor, was used for concurrent measurement of both neurometabolic substrates in vivo in the anesthetized rat brain. Rapid changes of lactate and glucose were observed in the cortex and hippocampus in response to local glucose and lactate application and upon insulin-induced fluctuations of systemic glucose. Overall, these results indicate that microbiosensors are a valuable tool to investigate neurometabolism and to better understand the role of major neurometabolic markers, such as lactate and glucose.<\/jats:p>","DOI":"10.3390\/molecules27020514","type":"journal-article","created":{"date-parts":[[2022,1,16]],"date-time":"2022-01-16T20:45:21Z","timestamp":1642365921000},"page":"514","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Design and Evaluation of a Lactate Microbiosensor: Toward Multianalyte Monitoring of Neurometabolic Markers In Vivo in the Brain"],"prefix":"10.3390","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8123-7007","authenticated-orcid":false,"given":"Eliana","family":"Fernandes","sequence":"first","affiliation":[{"name":"Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal"},{"name":"Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7737-4241","authenticated-orcid":false,"given":"Ana","family":"Ledo","sequence":"additional","affiliation":[{"name":"Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal"},{"name":"Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1604-6324","authenticated-orcid":false,"given":"Rui M.","family":"Barbosa","sequence":"additional","affiliation":[{"name":"Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal"},{"name":"Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2022,1,14]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.tins.2013.07.001","article-title":"Sugar for the brain: The role of glucose in physiological and pathological brain function","volume":"36","author":"Mergenthaler","year":"2013","journal-title":"Trends Neurosci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1016\/j.cmet.2011.08.016","article-title":"Brain Energy Metabolism: Focus on Astrocyte-Neuron Metabolic Cooperation","volume":"14","author":"Allaman","year":"2011","journal-title":"Cell Metab. Rev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1546","DOI":"10.1016\/j.cmet.2021.07.006","article-title":"Astrocyte-neuron metabolic cooperation shapes brain activity","volume":"33","author":"Bonvento","year":"2021","journal-title":"Cell Metab."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"101454","DOI":"10.1016\/j.redox.2020.101454","article-title":"Lactate as a fulcrum of metabolism","volume":"35","author":"Brooks","year":"2020","journal-title":"Redox Biol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1038\/nrn.2018.19","article-title":"Lactate in the brain: From metabolic end-product to signalling molecule","volume":"19","author":"Magistretti","year":"2018","journal-title":"Nat. Rev. Neurosci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1038\/jcbfm.2011.175","article-title":"Brain lactate metabolism: The discoveries and the controversies","volume":"32","author":"Dienel","year":"2012","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"13267","DOI":"10.1021\/acsomega.8b02055","article-title":"Analytical and Quantitative in Vivo Monitoring of Brain Neurochemistry by Electrochemical and Imaging Approaches","volume":"3","author":"Wu","year":"2018","journal-title":"ACS Omega"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1021\/acs.analchem.6b04278","article-title":"Analytical Techniques in Neuroscience: Recent Advances in Imaging, Separation, and Electrochemical Methods","volume":"89","author":"Ganesana","year":"2017","journal-title":"Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1021\/acssensors.7b00324","article-title":"Glucose and Lactate Miniaturized Biosensors for SECM-Based High-Spatial Resolution Analysis: A Comparative Study","volume":"2","author":"Valenti","year":"2017","journal-title":"ACS Sensors"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2996","DOI":"10.1021\/ac5047455","article-title":"Platinum-doped ceria based biosensor for in vitro and in vivo monitoring of lactate during hypoxia","volume":"87","author":"Sardesai","year":"2015","journal-title":"Anal. Chem."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3173","DOI":"10.1021\/ac950630x","article-title":"Thin-Film Microbiosensors for Glucose-Lactate Monitoring","volume":"68","author":"Jobst","year":"1996","journal-title":"Anal. Chem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"8096","DOI":"10.1021\/ac301670h","article-title":"Ultrafast detection and quantification of brain signaling molecules with carbon fiber microelectrodes","volume":"84","author":"Lama","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1039\/B807563H","article-title":"Carbon-fiber microelectrodes for in vivo applications","volume":"134","author":"Huffman","year":"2009","journal-title":"Analyst."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1964","DOI":"10.1021\/la053032e","article-title":"Carbon-fiber microelectrodes modified with 4-sulfobenzene have increased sensitivity and selectivity for catecholamines","volume":"22","author":"Hermans","year":"2006","journal-title":"Langmuir"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2554","DOI":"10.1021\/cr068081q","article-title":"Monitoring rapid chemical communication in the brain","volume":"108","author":"Robinson","year":"2008","journal-title":"Chem. Rev."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.cbpa.2008.06.035","article-title":"Microelectrodes for studying neurobiology","volume":"12","author":"Kita","year":"2008","journal-title":"Curr. Opin. Chem. Biol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.trac.2007.11.008","article-title":"Designing sensitive and selective polymer\/enzyme composite biosensors for brain monitoring in vivo","volume":"27","author":"Rocchitta","year":"2008","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.1021\/acscentsci.8b00797","article-title":"Minimally Invasive Microelectrode Biosensors Based on Platinized Carbon Fibers for in Vivo Brain Monitoring","volume":"4","author":"Chatard","year":"2018","journal-title":"ACS Cent. Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"6646","DOI":"10.1021\/acs.analchem.0c05108","article-title":"Fiber-Based Electrochemical Biosensors for Monitoring pH and Transient Neurometabolic Lactate","volume":"93","author":"Booth","year":"2021","journal-title":"Anal. Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/S0165-0270(01)00396-X","article-title":"Effects of recording media composition on the responses of Nafion-coated carbon fiber microelectrodes measured using high-speed chronoamperometry","volume":"109","author":"Gerhardt","year":"2001","journal-title":"J. Neurosci. Methods"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"113614","DOI":"10.1016\/j.jelechem.2019.113614","article-title":"The selective electrochemical sensing of dopamine at a polypyrrole film doped with an anionic \u03b2\u2212cyclodextrin","volume":"855","author":"Harley","year":"2019","journal-title":"J. Electroanal Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.1016\/j.electacta.2009.09.069","article-title":"Effects of polymerization potential on the permselectivity of poly(o-phenylenediamine) coatings deposited on Pt-Ir electrodes for biosensor applications","volume":"55","author":"Rothwell","year":"2010","journal-title":"Electrochim. Acta."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2735","DOI":"10.1021\/ac00223a016","article-title":"Glucose Fast-Response Amperometric Sensor Based on Glucose Oxidase Immobilized in an Electropolymerized Poly(o-phenylenediamine) Film","volume":"62","author":"Malitesta","year":"1990","journal-title":"Anal. Chem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2128","DOI":"10.1039\/b408051n","article-title":"The selectivity of electrosynthesised polymer membranes depends on the electrode dimensions: Implications for biosensor applications","volume":"18","author":"McMahon","year":"2004","journal-title":"Chem. Commun."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"7303","DOI":"10.1016\/j.electacta.2008.03.076","article-title":"Characterization of permselective coatings electrosynthesized on Pt-Ir from the three phenylenediamine isomers for biosensor applications","volume":"53","author":"Killoran","year":"2008","journal-title":"Electrochim. Acta"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"107325","DOI":"10.1016\/j.bioelechem.2019.06.010","article-title":"Platinized carbon fiber-based glucose microbiosensor designed for metabolic studies in brain slices","volume":"130","author":"Caetano","year":"2019","journal-title":"Bioelectrochemistry"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1016\/j.snb.2012.12.077","article-title":"Highly selective and stable microdisc biosensors for l-glutamate monitoring","volume":"178","author":"Govindarajan","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_28","first-page":"1209","article-title":"Lactate as a biomarker for sleep","volume":"35","author":"Naylor","year":"2012","journal-title":"Sleep."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1007\/s12678-011-0054-1","article-title":"Determining the Active Surface Area for Various Platinum Electrodes","volume":"2","author":"Chen","year":"2011","journal-title":"Electrocatalysis"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"8392","DOI":"10.1039\/C4CP00342J","article-title":"Electrochemical characteristics of nanostructured platinum electrodes-A cyclic voltammetry study","volume":"16","author":"Daubinger","year":"2014","journal-title":"Phys. Chem. Chem. Phys."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"24","DOI":"10.3126\/jncs.v29i0.9233","article-title":"Stability of Platinum in Sulfuric Acid Solution Studied by Electrochemical Quartz Crystal Microbalance","volume":"29","author":"Yadav","year":"2012","journal-title":"J. Nepal Chem. Soc."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1351\/pac199163050711","article-title":"International Union of Pure and Applied Chemistry Physical Chemistry Division Commission on Electrochemistry: Real Surface Area Measurements in Electrochemistry","volume":"63","author":"Trasatti","year":"1991","journal-title":"Pure Appl. Chem."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"14756","DOI":"10.1021\/ja902876v","article-title":"Adsorption\/desorption of hydrogen on Pt nanoelectrodes: Evidence of surface diffusion and spillover","volume":"131","author":"Zhan","year":"2009","journal-title":"J. Am. Chem. Soc."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"7384","DOI":"10.1039\/c2cp40616k","article-title":"Hydrogen peroxide electrochemistry on platinum: Towards understanding the oxygen reduction reaction mechanism","volume":"14","author":"Katsounaros","year":"2012","journal-title":"Phys. Chem. Chem. Phys."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2388","DOI":"10.1016\/j.bios.2004.12.003","article-title":"Biosensors for real-time in vivo measurements","volume":"20","author":"Wilson","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.aca.2006.03.034","article-title":"Highly selective microbiosensors for in vivo measurement of glucose, lactate and glutamate","volume":"573\u2013574","author":"Schuvailo","year":"2006","journal-title":"Anal. Chim. Acta."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"2596","DOI":"10.1166\/jctn.2014.3678","article-title":"Non-linearization of modified Michaelis-Menten kinetics","volume":"11","author":"Nesakumar","year":"2014","journal-title":"J. Comput. Theor. Nanosci."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Sandstrom, M.I., and Rebec, G.V. (2007). Extracellular ascorbate modulates glutamate dynamics: Role of behavioral activation. BMC Neurosci., 8.","DOI":"10.1186\/1471-2202-8-32"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1002\/elan.201300053","article-title":"Real Time In Vivo Measurement of Ascorbate in the Brain Using Carbon Nanotube-Modified Microelectrodes","volume":"25","author":"Ferreira","year":"2013","journal-title":"Electroanalysis"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1626","DOI":"10.1111\/j.1471-4159.2006.03673.x","article-title":"Microelectrode array studies of basal and potassium-evoked release of L-glutamate in the anesthetized rat brain","volume":"96","author":"Day","year":"2006","journal-title":"J. Neurochem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/S0076-6879(08)01220-2","article-title":"In Vivo Real-Time Measurement of Nitric Oxide in Anesthetized Rat Brain","volume":"441","author":"Barbosa","year":"2008","journal-title":"Methods Enzymol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2618","DOI":"10.1021\/ac971299f","article-title":"In Vivo Voltammetric Detection of Rat Brain Lactate with Carbon Fiber Microelectrodes Coated with Lactate Oxidase","volume":"70","author":"Shram","year":"1998","journal-title":"Anal Chem."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"5910","DOI":"10.1016\/S1452-3981(23)19451-X","article-title":"Biosensors based on prussian blue modified carbon fibers electrodes for monitoring lactate in the extracellular space of brain tissue","volume":"7","author":"Salazar","year":"2012","journal-title":"Int. J. Electrochem. Sci."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"12994","DOI":"10.1021\/acs.analchem.8b03694","article-title":"Carbon-Fiber Microbiosensor for Monitoring Rapid Lactate Fluctuations in Brain Tissue Using Fast-Scan Cyclic Voltammetry","volume":"90","author":"Smith","year":"2018","journal-title":"Anal. Chem."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"6764","DOI":"10.1038\/s41598-017-07119-6","article-title":"Neurometabolic and electrophysiological changes during cortical spreading depolarization: Multimodal approach based on a lactate-glucose dual microbiosensor arrays","volume":"7","author":"Ledo","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"1772","DOI":"10.1016\/j.bios.2004.07.003","article-title":"L-lactate measures in brain tissue with ceramic-based multisite microelectrodes","volume":"20","author":"Burmeister","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/j.bios.2014.09.101","article-title":"In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device","volume":"67","author":"Cordeiro","year":"2015","journal-title":"Biosens. Bioelectron."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"10282","DOI":"10.1021\/ac402071w","article-title":"Simultaneous telemetric monitoring of brain glucose and lactate and motion in freely moving rats","volume":"85","author":"Rocchitta","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1021\/ac048686r","article-title":"Polymer-enzyme composite biosensor with high glutamate sensitivity and low oxygen dependence","volume":"77","author":"McMahon","year":"2005","journal-title":"Anal. Chem."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1161\/01.STR.18.3.616","article-title":"Comparisons of oxygen metabolism and tissue po2in cortex and hippocampus of gerbil brain","volume":"18","author":"Nair","year":"1987","journal-title":"Stroke"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.1016\/S0002-9440(10)63747-9","article-title":"Physiological and pathological responses to hypoxia","volume":"164","author":"Michiels","year":"2004","journal-title":"Am. J. Pathol."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1007\/BF00374792","article-title":"A novel, remote-controlled suspension device for brain tissue PO2 measurements with multiwire surface electrodes","volume":"426","author":"Murr","year":"1994","journal-title":"Pfl\u00fcgers Arch. Eur. J. Physiol."},{"key":"ref_53","first-page":"989487","article-title":"Brain temperature: Physiology and pathophysiology after brain injury","volume":"2012","author":"Mrozek","year":"2012","journal-title":"Anesthesiol. Res. Pract."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1152\/physrev.00010.2003","article-title":"Regulation and modulation of pH in the brain","volume":"83","author":"Chesler","year":"2003","journal-title":"Physiol. Rev."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1002\/nbm.1312","article-title":"Brain temperature and pH measured by 1H chemical shift imaging of a thulium agent","volume":"22","author":"Coman","year":"2009","journal-title":"NMR Biomed."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"2928","DOI":"10.1021\/ac971182r","article-title":"Reduction of Interference Response at a Hydrogen Peroxide Detecting Electrode Using Electropolymerized Films of Substituted Naphthalenes","volume":"70","author":"Murphy","year":"1998","journal-title":"Anal. Chem."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"3993","DOI":"10.1016\/j.bios.2011.03.012","article-title":"Covalent enzyme immobilization by poly(ethylene glycol) diglycidyl ether (PEGDE) for microelectrode biosensor preparation","volume":"26","author":"Vasylieva","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1046\/j.1471-4159.2003.01673.x","article-title":"Quantitative on-line monitoring of hippocampus glucose and lactate metabolism in organotypic cultures using biosensor technology","volume":"85","author":"Gramsbergen","year":"2003","journal-title":"J. Neurochem."},{"key":"ref_59","first-page":"49","article-title":"Blood Brain Barrier Permeability to Lactate","volume":"6","author":"Oldendorf","year":"1971","journal-title":"Cereb Blood Flow Intracran. Press."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"4358","DOI":"10.1021\/ac960190p","article-title":"In vivo brain glucose measurements: Differential normal pulse voltammetry with enzyme-modified carbon fiber microelectrodes","volume":"68","author":"Netchiporouk","year":"1996","journal-title":"Anal. Chem."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1113\/expphysiol.1998.sp004107","article-title":"The relation between local cerebral blood flow and extracellular glucose concentration in rat striatum","volume":"83","author":"Fillenz","year":"1998","journal-title":"Exp. Physiol."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/j.bios.2015.05.004","article-title":"Silicon\/SU8 multi-electrode micro-needle for in vivo neurochemical monitoring","volume":"72","author":"Vasylieva","year":"2015","journal-title":"Biosens. Bioelectron."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.bios.2013.11.048","article-title":"A high sensitivity MEA probe for measuring real time rat brain glucose flux","volume":"55","author":"Wei","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1016\/j.snb.2016.06.083","article-title":"Microelectrode array biosensor for high-resolution measurements of extracellular glucose in the brain","volume":"237","author":"Ledo","year":"2016","journal-title":"Sens. Actuators B Chem."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/j.jneumeth.2011.07.003","article-title":"Simultaneous measurements of glucose, oxyhemoglobin and deoxyhemoglobin in exposed rat cortex","volume":"202","author":"Roche","year":"2011","journal-title":"J. Neurosci. Methods."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"1674","DOI":"10.1021\/acs.analchem.6b03772","article-title":"Ceramic-Based Multisite Platinum Microelectrode Arrays: Morphological Characteristics and Electrochemical Performance for Extracellular Oxygen Measurements in Brain Tissue","volume":"89","author":"Ledo","year":"2017","journal-title":"Anal. Chem."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1038\/ncb1881","article-title":"The bioenergetic and antioxidant status of neurons is controlled by continuous degradation of a key glycolytic enzyme by APC\/C-Cdh1","volume":"11","author":"Almeida","year":"2009","journal-title":"Nat. Cell Biol."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1016\/j.freeradbiomed.2010.01.024","article-title":"Dynamic and Interacting Profiles of \u2022NO and O2 in Rat Hippocampal Slices","volume":"48","author":"Ledo","year":"2010","journal-title":"Free Radic. Biol. Med."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"4399","DOI":"10.5194\/acp-15-4399-2015","article-title":"Compilation of Henry\u2019s law constants (version 4.0) for water as solvent","volume":"15","author":"Sander","year":"2015","journal-title":"Atmos. Chem. Phys."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/j.bios.2008.06.034","article-title":"A comparative study of carbon fiber-based microelectrodes for the measurement of nitric oxide in brain tissue","volume":"24","author":"Santos","year":"2008","journal-title":"Biosens. Bioelectron."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.bioelechem.2018.01.009","article-title":"Simultaneous measurements of ascorbate and glutamate in vivo in the rat brain using carbon fiber nanocomposite sensors and microbiosensor arrays","volume":"121","author":"Ferreira","year":"2018","journal-title":"Bioelectrochemistry"},{"key":"ref_72","unstructured":"Paxinos, G., and Watson, C. (2007). The Rat Brain in Stereotaxic Coordinates, Elsevier Inc.. [6th ed.]."}],"container-title":["Molecules"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1420-3049\/27\/2\/514\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T13:39:48Z","timestamp":1760362788000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1420-3049\/27\/2\/514"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,14]]},"references-count":72,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2022,1]]}},"alternative-id":["molecules27020514"],"URL":"https:\/\/doi.org\/10.3390\/molecules27020514","relation":{},"ISSN":["1420-3049"],"issn-type":[{"value":"1420-3049","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,14]]}}}