{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:18:43Z","timestamp":1760242723786,"version":"build-2065373602"},"reference-count":27,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2016,3,9]],"date-time":"2016-03-09T00:00:00Z","timestamp":1457481600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["UID\/EEA\/5001\/2013","SFRH\/BPD\/79154\/2011"],"award-info":[{"award-number":["UID\/EEA\/5001\/2013","SFRH\/BPD\/79154\/2011"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This article describes a method that improves the performance of previous approaches for the automatic detection of the common carotid artery (CCA) lumen centerline on longitudinal B-mode ultrasound images. We propose to detect several lumen centerline candidates using local symmetry analysis based on local phase information of dark structures at an appropriate scale. These candidates are analyzed with selection mechanisms that use symmetry, contrast or intensity features in combination with position-based heuristics. Several experimental results are provided to evaluate the robustness and performance of the proposed method in comparison with previous approaches. These results lead to the conclusion that our proposal is robust to noise, lumen artifacts, contrast variations and that is able to deal with the presence of CCA-like structures, significantly improving the performance of our previous approach, from                                        87.5%               \u00b1               0.7%                                  of correct detections to                                        98.3%               \u00b1               0.3%                                  in a set of 200 images.<\/jats:p>","DOI":"10.3390\/s16030350","type":"journal-article","created":{"date-parts":[[2016,3,9]],"date-time":"2016-03-09T10:38:02Z","timestamp":1457519882000},"page":"350","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Automatic Lumen Detection on Longitudinal Ultrasound B-Mode Images of the Carotid Using Phase Symmetry"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4407-9091","authenticated-orcid":false,"given":"Jos\u00e9","family":"Rouco","sequence":"first","affiliation":[{"name":"INESC TEC \u2013 INESC Technology and Science, FEUP, Rua Dr. Roberto Frias s\/n, Porto 4200-465, Portugal"}]},{"given":"Elsa","family":"Azevedo","sequence":"additional","affiliation":[{"name":"FMUP \u2013 Faculty of Medicine, University of Porto, Porto 4200-319, Portugal"},{"name":"Department of Neurology, S\u00e3o Jo\u00e3o Hospital Center, Porto 4200-319, Portugal"}]},{"given":"Aur\u00e9lio","family":"Campilho","sequence":"additional","affiliation":[{"name":"INESC TEC \u2013 INESC Technology and Science, FEUP, Rua Dr. Roberto Frias s\/n, Porto 4200-465, Portugal"},{"name":"FEUP \u2013 Faculty of Engineering, University of Porto, Porto 4200-465, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2016,3,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1159\/000343145","article-title":"Mannheim Carotid Intima-Media Thickness Consensus (2004-2006-2011). An Update on Behalf of the Advisory Board of the 3rd, 4th and 5th Watching the Risk Symposium 13th, 15th and 20th European Stroke Conferences, Mannheim, Germany, 2004, Brussels, Belgium, 2006 and Hamburg, Germany, 2011","volume":"34","author":"Touboul","year":"2012","journal-title":"Cerebrovasc. Dis."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.echo.2007.11.011","article-title":"American Society of Echocardiography Carotid Intima-Media Thickness Task Force. Use of carotid ultrasound to indentify subclinical vascular disease and evaluate cardiovascular disease risk: A consensus statement from the American Society of Echocardiography Carotid Intima-Media Thickness Task Force endorsed by the Society for Vascular Medicine","volume":"21","author":"Stein","year":"2008","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2094","DOI":"10.1093\/eurheartj\/ehm244","article-title":"Carotid intima-media thickness by B-mode ultrasound as surrogate of coronary atherosclerosis: Correlation with quantitative coronary angiography and coronary intravascular ultrasound findings","volume":"28","author":"Amato","year":"2007","journal-title":"Eur. Heart J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.atherosclerosis.2006.04.008","article-title":"Measurement of carotid artery intima-media thickness in dyslipidemic patients increases the power of traditional risk factors to predict cardiovascular events","volume":"191","author":"Baldassarre","year":"2007","journal-title":"Atherosclerosis"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1161\/CIRCULATIONAHA.106.628875","article-title":"Prediction of clinical cardiovascular events with carotid intima-media thickness: A systematic review and meta-analysis","volume":"115","author":"Lorenz","year":"2007","journal-title":"Circulation"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1093\/eurheartj\/ehr192","article-title":"Common carotid artery intima-media thickness is as good as carotid intima-media thickness of all carotid artery segments in improving prediction of coronary heart disease risk in the Atherosclerosis Risk in Communities (ARIC) study","volume":"33","author":"Nambi","year":"2012","journal-title":"Eur. Heart J."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.cmpb.2010.04.007","article-title":"A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound","volume":"100","author":"Molinari","year":"2010","journal-title":"Comput. Methods Progr. Biomed."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1109\/42.836372","article-title":"A Multiscale Dynamic Programming Procedure for Boundary Detection in Ultrasonic Artery Images","volume":"19","author":"Liang","year":"2000","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1007\/s11517-012-0883-y","article-title":"Automatic segmentation of carotid B-mode images using fuzzy classification","volume":"50","author":"Rocha","year":"2012","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1016\/j.media.2008.03.003","article-title":"Automatic recognition of the common carotid artery in longitudinal ultrasound B-mode scans","volume":"12","author":"Rossi","year":"2008","journal-title":"Med. Image Anal."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1142\/S0219519409003115","article-title":"Automatic Computer-based Tracings (ACT) in longitudinal 2-D ultrasound images using different scanners","volume":"9","author":"Molinari","year":"2009","journal-title":"J. Mech. Med. Biol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1007\/s11517-011-0781-8","article-title":"Completely Automated Robust Edge Snapper for Carotid Ultrasound IMT Measurement on a Multi-Institutional Database of 300 Images","volume":"49","author":"Molinari","year":"2011","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1054","DOI":"10.1109\/TIM.2011.2174901","article-title":"Hypothesis Validation of Far-Wall Brightness in Carotid-Artery Ultrasound for Feature-Based IMT Measurement Using a Combination of Level-Set Segmentation and Registration","volume":"61","author":"Molinari","year":"2012","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1109\/TIP.2011.2169270","article-title":"Completely Automated Multiresolution Edge Snapper\u2014A New Technique for an Accurate Carotid Ultrasound IMT Measurement: Clinical Validation and Benchmarking on Multi-Institutional Database","volume":"21","author":"Molinari","year":"2012","journal-title":"IEEE Trans. Image Process."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1109\/TUFFC.2013.2547","article-title":"Fully Automated Segmentation and Tracking of the Intima Media Thickness in Ultrasound Video Sequences of the Common Carotid Artery","volume":"60","author":"Ilea","year":"2013","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1007\/s10278-012-9481-7","article-title":"Segmentation of the Common Carotid Artery Walls Based on a Frequency Implementation of Active Contours","volume":"26","year":"2013","journal-title":"J. Digit. Imaging"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1016\/j.imavis.2009.09.017","article-title":"Segmentation of the carotid intima-media region in B-mode ultrasound images","volume":"28","author":"Rocha","year":"2010","journal-title":"Image Vis. Comput."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Rouco, J., and Campilho, A. (2013, January 26\u201331). Robust Common Carotid Artery Lumen Detection in B-Mode Ultrasound Images using Local Phase Symmetry. Proceedings of the 2013 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Vancouver, BC, USA.","DOI":"10.1109\/ICASSP.2013.6637785"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.cmpb.2014.04.004","article-title":"Automatic detection of the carotid lumen axis in B-mode ultrasound images","volume":"115","author":"Rocha","year":"2014","journal-title":"Comput. Methods Progr. Biomed."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3136","DOI":"10.1109\/78.969520","article-title":"The Monogenic Signal","volume":"49","author":"Felsberg","year":"2001","journal-title":"IEEE Trans. Sign. Process."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Webb, A. (2002). Statistical Pattern Recognition, Jonh Wiley & Sons. [2nd ed.].","DOI":"10.1002\/0470854774"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1161\/01.STR.0000206440.48756.f7","article-title":"Carotid artery diameter in men and women and the relation to body and neck size","volume":"37","author":"Krejza","year":"2006","journal-title":"Stroke"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2221","DOI":"10.1109\/TIP.2009.2024064","article-title":"Nonlocal means-based speckle filtering for ultrasound images","volume":"18","author":"Hellier","year":"2009","journal-title":"IEEE Trans. Image Process."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1109\/31.16577","article-title":"An Adaptive Weighted Mean Filter for Speckle Suppression in Medical Ultrasound Images","volume":"36","author":"Loupas","year":"1989","journal-title":"IEEE Trans. Circuits Syst."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.sigpro.2013.12.019","article-title":"Nonlocal means method using weight refining for despeckling of ultrasound images","volume":"103","author":"Zhan","year":"2014","journal-title":"Signal Process."},{"key":"ref_26","first-page":"177","article-title":"On the Automatic Normalization of Plaque Regions in Ultrasound Images of the Carotid","volume":"8814","author":"Rouco","year":"2014","journal-title":"Lect. Notes Comput. Sci. Image Anal. Recognit. ICIAR"},{"key":"ref_27","unstructured":"Kovesi, P. (1997, January 2\u20134). Symmetry and Asymmetry from Local Phase. Proceedings of the Tenth Australian Joint Conference on Artificial Intelligence \u2013 Poster Papers, Perth, Australia."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/3\/350\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:20:25Z","timestamp":1760210425000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/3\/350"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3,9]]},"references-count":27,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2016,3]]}},"alternative-id":["s16030350"],"URL":"https:\/\/doi.org\/10.3390\/s16030350","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2016,3,9]]}}}