{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T15:36:55Z","timestamp":1776699415624,"version":"3.51.2"},"reference-count":21,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2018,9,21]],"date-time":"2018-09-21T00:00:00Z","timestamp":1537488000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["UID\/EEA\/50008\/2013"],"award-info":[{"award-number":["UID\/EEA\/50008\/2013"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A velocity induced eddy current probe has been used to detect cracks in both non-ferromagnetic and ferromagnetic metals. The simulation and experimental results show that this probe can successfully detect cracks in both cases, but further investigation shows that the underlying principles for inspecting non-ferromagnetic and ferromagnetic metals are actually different. For an aluminum plate, the induced eddy current density and the signal amplitude both increase with probe speed, which means the signal is caused by velocity induced eddy currents. For a steel plate, probe speed changes the baselines of the testing signals; however, it has little influence on signal amplitudes. Simulation results show that the signal for cracks in a steel plate is mainly caused by direct magnetic field perturbation rather than velocity induced eddy currents.<\/jats:p>","DOI":"10.3390\/s18103199","type":"journal-article","created":{"date-parts":[[2018,9,21]],"date-time":"2018-09-21T11:00:25Z","timestamp":1537527625000},"page":"3199","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Comparison of Inspecting Non-Ferromagnetic and Ferromagnetic Metals Using Velocity Induced Eddy Current Probe"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1057-3932","authenticated-orcid":false,"given":"Bo","family":"Feng","sequence":"first","affiliation":[{"name":"Instituto de Telecomunica\u00e7\u00f5es, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7475-3422","authenticated-orcid":false,"given":"Artur L.","family":"Ribeiro","sequence":"additional","affiliation":[{"name":"Instituto de Telecomunica\u00e7\u00f5es, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal"}]},{"given":"Tiago J.","family":"Rocha","sequence":"additional","affiliation":[{"name":"Instituto de Telecomunica\u00e7\u00f5es, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4931-7960","authenticated-orcid":false,"given":"Helena G.","family":"Ramos","sequence":"additional","affiliation":[{"name":"Instituto de Telecomunica\u00e7\u00f5es, Instituto Superior T\u00e9cnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2018,9,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Mix, P.E. (2005). Introduction to Nondestructive Testing: A Training Guide, John Wiley & Sons Inc.. [2nd ed.].","DOI":"10.1002\/0471719145"},{"key":"ref_2","unstructured":"Rao, B.P.B. (2006). Practical Eddy Current Testing, Alpha Science International Limited."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1109\/TIM.2017.2682758","article-title":"Inspection of Cracks in Aluminum Multilayer Structures Using Planar ECT Probe and Inversion Problem","volume":"66","author":"Pasadas","year":"2017","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.ndteint.2009.10.010","article-title":"Pulsed eddy current technique for defect detection in aircraft riveted structures","volume":"43","author":"He","year":"2010","journal-title":"NDT E Int."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1109\/JSEN.2004.839129","article-title":"Multiple sensors on pulsed eddy-current detection for 3-D subsurface crack assessment","volume":"5","author":"Tian","year":"2005","journal-title":"IEEE Sens. J."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Ribeiro, A.L., and Ramos, H.G. (2008, January 12\u201315). Inductive probe for flaw detection in non-magnetic metallic plates using eddy currents. Proceedings of the Instrumentation and Measurement Technology Conference, Victoria, BC, Canada.","DOI":"10.1109\/IMTC.2008.4547270"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.sna.2015.02.004","article-title":"Magnetic sensors assessment in velocity induced eddy current testing","volume":"228","author":"Rocha","year":"2015","journal-title":"Sens. Actuator A Phys."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1080\/09349847.2015.1061721","article-title":"Theoretical Analysis and Numerical Simulation of the Feasibility of Inspecting Nonferromagnetic Conductors by an MFL Testing Apparatus","volume":"27","author":"Feng","year":"2016","journal-title":"Res. Nondestruct. Eval."},{"key":"ref_9","first-page":"1","article-title":"Optimal magnet design for Lorentz force eddy-current testing","volume":"51","author":"Weise","year":"2015","journal-title":"IEEE Trans. Magn."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1080\/09349849609409601","article-title":"Signal processing for in-line inspection of gas transmission pipelines","volume":"8","author":"Mandayam","year":"1996","journal-title":"Res. Nondestruct. Eval."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1109\/TMAG.2004.824717","article-title":"Analysis of the velocity-induced eddy current in MFL type NDT","volume":"40","author":"Park","year":"2004","journal-title":"IEEE Trans. Magn."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"357","DOI":"10.3233\/JAE-162076","article-title":"Influence of motion induced eddy current on the magnetization of steel pipe and MFL signal","volume":"52","author":"Feng","year":"2016","journal-title":"Int. J. Appl. Electromagn. Mech."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/j.ndteint.2005.10.006","article-title":"Numerical simulation on magnetic flux leakage evaluation at high speed","volume":"39","author":"Li","year":"2006","journal-title":"NDT E Int."},{"key":"ref_14","first-page":"1","article-title":"The effect of motion-induced eddy current on circumferential magnetization in MFL testing for a steel pipe","volume":"53","author":"Wu","year":"2017","journal-title":"IEEE Trans. Magn."},{"key":"ref_15","unstructured":"Rocha, T.J. (2017). Velocity Induced Eddy Current Testing. [Ph.D. Thesis, Instituto Superior T\u00e9cnico]."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.measurement.2015.02.003","article-title":"Studies to optimize the probe response for velocity induced eddy current testing in aluminium","volume":"67","author":"Rocha","year":"2015","journal-title":"Measurement"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1109\/TIM.2015.2507738","article-title":"Evaluation of subsurface defects using diffusion of motion-induced eddy currents","volume":"65","author":"Rocha","year":"2016","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"094914","DOI":"10.1063\/1.4716005","article-title":"Lorentz force sigmometry: A contactless method for electrical conductivity measurements","volume":"111","author":"Uhlig","year":"2012","journal-title":"J. Appl. Phys."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.ndteint.2013.05.005","article-title":"Lorentz force evaluation: A new approximation method for defect reconstruction","volume":"59","author":"Haueisen","year":"2013","journal-title":"NDT E Int."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ndteint.2010.01.007","article-title":"A new NDT method based on permanent magnetic field perturbation","volume":"44","author":"Sun","year":"2011","journal-title":"NDT E Int."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.ndteint.2016.01.004","article-title":"A magnetic perturbation GMR-based probe for the nondestructive evaluation of surface cracks in ferromagnetic steels","volume":"79","author":"Caleyo","year":"2016","journal-title":"NDT E Int."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/10\/3199\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:21:57Z","timestamp":1760196117000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/18\/10\/3199"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,21]]},"references-count":21,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2018,10]]}},"alternative-id":["s18103199"],"URL":"https:\/\/doi.org\/10.3390\/s18103199","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,21]]}}}