{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T12:23:07Z","timestamp":1769602987692,"version":"3.49.0"},"reference-count":36,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2020,3,17]],"date-time":"2020-03-17T00:00:00Z","timestamp":1584403200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Moisture is one of the major causes of problems in buildings, and it can compromise their performance. Infrared thermography (IRT) is a non-destructive testing technology that can be used to assess the humidification phenomenon and, thus, prevent some of the problems caused by moisture. The images obtained by IRT reflect the thermal patterns of the surface under study and can be evaluated using a quantitative approach, which allows not only the traditional visualization of the thermal patterns but also quantification of surface temperatures and\/or their differences. The relevance of this work is related to the discussion of the strengths and weaknesses of several methods to quantitatively assess the humidification phenomenon using IRT. For that purpose, the partial humidification by the bottom surface of a lightweight concrete specimen was considered as a case study. To evaluate the thermal gradients, the evolution of the thermal imaging throughout the measurement period and the definition of the areas particularly affected by moisture, a methodology that included a pre-processing phase for data reduction, followed by a data processing phase, were implemented. In the data processing, different statistical and numerical methods were tested. The results of the statistical descriptive analysis highlighted the time variation of the surface temperature, both when considering the entire specimen and when considering only specific areas. The variability of the temperatures at certain moments of the experiment could be observed in the box-plot representation. The image subtraction proved to be an interesting technique to quantify the temperature differences if the first image was used as reference. A thermal index, TI, was proposed to assess the cooling rate. The index highlighted the initial instant when the effect of moisture on the surface temperature was detectable.<\/jats:p>","DOI":"10.3390\/s20061664","type":"journal-article","created":{"date-parts":[[2020,3,18]],"date-time":"2020-03-18T08:20:44Z","timestamp":1584519644000},"page":"1664","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Quantitative Infrared Thermography to Evaluate the Humidification of Lightweight Concrete"],"prefix":"10.3390","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1343-5578","authenticated-orcid":false,"given":"Eva","family":"Barreira","sequence":"first","affiliation":[{"name":"CONSTRUCT-LFC, Department of Civil Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias s\/n, 4200-465 Porto, Portugal"}]},{"given":"Ricardo M.S.F.","family":"Almeida","sequence":"additional","affiliation":[{"name":"CONSTRUCT-LFC, Department of Civil Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias s\/n, 4200-465 Porto, Portugal"},{"name":"Department of Civil Engineering, Polytechnic Institute of Viseu, Campus Polit\u00e9cnico de Repeses, 3504-510 Viseu, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0639-3867","authenticated-orcid":false,"given":"Maria","family":"L. Sim\u00f5es","sequence":"additional","affiliation":[{"name":"CONSTRUCT-LFC, Department of Civil Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias s\/n, 4200-465 Porto, Portugal"}]},{"given":"Daniela","family":"Rebelo","sequence":"additional","affiliation":[{"name":"CONSTRUCT-LFC, Department of Civil Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias s\/n, 4200-465 Porto, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2020,3,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Maldague, X. (1993). Nondestructive Evaluation of Materials by Infrared Thermography, Springer.","DOI":"10.1007\/978-1-4471-1995-1"},{"key":"ref_2","unstructured":"Hart, J. (2001). A Practical Guide for Infra-Red Thermography for Building Surveys, BRE."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1108\/02630809810219669","article-title":"Assessing building fa\u00e7ades using infra-red thermography","volume":"16","author":"Chew","year":"1998","journal-title":"Struct. Surv."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.enbuild.2003.12.012","article-title":"Thermographic survey of two rural buildings in Spain","volume":"36","author":"Guerrero","year":"2004","journal-title":"Energy Build."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1108\/SS-05-2014-0021","article-title":"Infrared thermography\u2014Evaluation of the results reproducibility","volume":"33","author":"Bauer","year":"2015","journal-title":"Struct. Surv."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.enbuild.2017.02.009","article-title":"An infrared thermography passive approach to assess the effect of leakage points in buildings","volume":"140","author":"Barreira","year":"2017","journal-title":"Energy Build."},{"key":"ref_7","unstructured":"ASTM C1371-04a (2010). Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers, American Society for Testing and Materials."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.ijthermalsci.2017.04.003","article-title":"Evaluation of the state of conservation of mosaics: Simulations and thermographic signal processing","volume":"117","author":"Sfarra","year":"2017","journal-title":"Int. J. Therm. Sci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.infrared.2004.03.020","article-title":"Moisture detection in wood and plaster by IR thermography","volume":"46","author":"Ludwig","year":"2004","journal-title":"Infrared Phys. Technol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1007\/s10973-019-08264-y","article-title":"Automatic detection of moistures in different construction materials from thermographic images","volume":"138","author":"Garrido","year":"2019","journal-title":"J. Therm. Anal. Calorim."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1007\/s10973-015-4974-5","article-title":"Ceramics and defects. Infrared thermography and numerical simulations\u2014A wide-ranging view for quantitative analysis","volume":"123","author":"Sfarra","year":"2016","journal-title":"J. Therm. Anal. Calorim."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1080\/00103624.2017.1374399","article-title":"The use of thermography images in the description of the humidification bulb in soilless culture","volume":"48","author":"Urrestarazu","year":"2017","journal-title":"Commun. Soil Sci. Plant Anal."},{"key":"ref_13","first-page":"22","article-title":"Optimal thermographic procedures for moisture analysis in building materials","volume":"3827","author":"Rosina","year":"1999","journal-title":"Soc. Photogr. Instrum. Eng."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1117\/12.459581","article-title":"Detection of Moisture in Porous Materials by Infrared Thermography","volume":"4710","author":"Moropoulou","year":"2002","journal-title":"Thermosense XXIV"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"221","DOI":"10.3166\/qirt.8.221-238","article-title":"Thermographic signal reconstruction with periodic temperature variation applied to moisture classification","volume":"8","author":"Bison","year":"2011","journal-title":"Quant. Infrared Thermogr. J."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1770","DOI":"10.1080\/09500341003731597","article-title":"Moisture map by IR thermography","volume":"57","author":"Grinzato","year":"2010","journal-title":"J. Mod. Opt."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.conbuildmat.2016.02.026","article-title":"Infrared thermography for assessing moisture related phenomena in building components","volume":"110","author":"Barreira","year":"2016","journal-title":"Constr. Build. Mater."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1016\/j.enbuild.2017.12.048","article-title":"Effect of evaporation cooling on drying capillary active building materials","volume":"166","author":"Janetti","year":"2018","journal-title":"Energy Build."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.ijthermalsci.2016.12.018","article-title":"Determination of the water retention curve from drying experiments using infrared thermography: A preliminary study","volume":"114","author":"Janetti","year":"2017","journal-title":"Int. J. Therm. Sci."},{"key":"ref_20","unstructured":"Rajewski, G., and Devine, G. (1996). \u201cBuilding Envelope\u2014Infrared thermography\u201d. Preventative Roof Maintenance Workshop, Building Operator Association."},{"key":"ref_21","unstructured":"ASTM-C 1060-90 (2003). Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of FRAME buildings, American Society for Testing and Materials."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/S0378-7788(01)00105-0","article-title":"Infrared thermography for building diagnostics","volume":"34","author":"Balaras","year":"2002","journal-title":"Energy Build."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2190","DOI":"10.1016\/j.conbuildmat.2010.10.007","article-title":"Multitemporal thermal analysis to detect moisture on a building fa\u00e7ade","volume":"25","author":"Lerma","year":"2011","journal-title":"Constr. Build. Mater."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Vollmer, M., and M\u00f6llmann, K.P. (2010). Infrared Thermal Imaging: Fundamentals, Research and Applications, John Wiley & Sons.","DOI":"10.1002\/9783527630868"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"3051","DOI":"10.1007\/s10765-015-1962-8","article-title":"How to retrieve information inherent to old restorations made on frescoes of particular artistic value using infrared vision?","volume":"36","author":"Bendada","year":"2015","journal-title":"Int. J. Thermophys."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.culher.2015.07.011","article-title":"Diagnostics of wall paintings: A smart and reliable approach","volume":"18","author":"Sfarra","year":"2016","journal-title":"J. Cult. Herit."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"231","DOI":"10.3166\/qirt.3.231-245","article-title":"Determination of critical moisture content in porous materials by IR thermography","volume":"3","author":"Grinzato","year":"2006","journal-title":"Quant. Infrared Thermogr. J."},{"key":"ref_28","unstructured":"Grinzato, E. (2006). Monitoring of Thermal-Hygrometrical Conditions of Large Surfaces by IR. (PD2006A000191), Thermography. Patent."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Madruga, F.J., Sfarra, S., Perilli, S., Pivar\u010diov\u00e1, E., and L\u00f3pez-Higuera, J.M. (2020). Measuring the Water Content in Wood Using Step-Heating Thermography and Speckle Patterns-Preliminary Results. Sensors, 20.","DOI":"10.3390\/s20010316"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.buildenv.2015.07.027","article-title":"Quasi-quantitative infrared thermographic detection of moisture variation in facades with adhered ceramic cladding using principal component analysis","volume":"94","author":"Edis","year":"2015","journal-title":"Build. Environ."},{"key":"ref_31","unstructured":"Maldague, X. (2001). Theory and Practice of Infrared Technology for Nondestructive Testing, John Wiley & Sons."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1080\/09500340.2010.484553","article-title":"In situ examination of structural cracks at historic masonry structures by quantitative infrared thermography and ultrasonic testing","volume":"57","author":"Akevren","year":"2010","journal-title":"J. Mod. Opt."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Tran, Q.H., Han, D., Kang, C., Haldar, A., and Huh, J. (2017). Effects of Ambient Temperature and Relative Humidity on Subsurface Defect Detection in Concrete Structures by Active Thermal Imaging. Sensors, 17.","DOI":"10.3390\/s17081718"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.egypro.2017.09.757","article-title":"Assessing the humidification process of lightweight concrete specimens through infrared thermography","volume":"132","author":"Barreira","year":"2017","journal-title":"Energy Procedia"},{"key":"ref_35","unstructured":"BS EN 12390-7:2000 (2000). Testing Hardened Concrete. Density of Hardened Concrete, BSI, British Standards Institution."},{"key":"ref_36","unstructured":"ISO 15148:2002 (2002). Hygrothermal Performance of Building Materials and Products\u2014Determination of Water Absorption Coefficient by Partial Immersion, ISO, Thermal Performance of Buildings."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/6\/1664\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:07:27Z","timestamp":1760173647000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/6\/1664"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,17]]},"references-count":36,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2020,3]]}},"alternative-id":["s20061664"],"URL":"https:\/\/doi.org\/10.3390\/s20061664","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,17]]}}}