{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T20:30:55Z","timestamp":1770496255890,"version":"3.49.0"},"reference-count":26,"publisher":"MDPI AG","issue":"16","license":[{"start":{"date-parts":[[2024,8,17]],"date-time":"2024-08-17T00:00:00Z","timestamp":1723852800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Getty Conservation Institute (GCI)","award":["UIDB\/04029\/2020"],"award-info":[{"award-number":["UIDB\/04029\/2020"]}]},{"name":"Getty Conservation Institute (GCI)","award":["LA\/P\/0112\/2020"],"award-info":[{"award-number":["LA\/P\/0112\/2020"]}]},{"name":"R&amp;D Unit Institute for Sustainability and Innovation in Structural Engineering (ISISE)","award":["UIDB\/04029\/2020"],"award-info":[{"award-number":["UIDB\/04029\/2020"]}]},{"name":"R&amp;D Unit Institute for Sustainability and Innovation in Structural Engineering (ISISE)","award":["LA\/P\/0112\/2020"],"award-info":[{"award-number":["LA\/P\/0112\/2020"]}]},{"name":"Associate Laboratory Advanced Production and Intelligent Systems ARISE","award":["UIDB\/04029\/2020"],"award-info":[{"award-number":["UIDB\/04029\/2020"]}]},{"name":"Associate Laboratory Advanced Production and Intelligent Systems ARISE","award":["LA\/P\/0112\/2020"],"award-info":[{"award-number":["LA\/P\/0112\/2020"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The structural health monitoring (SHM) of buildings provides relevant data for the evaluation of the structural behavior over time, the efficiency of maintenance, strengthening, and post-earthquake conditions. This paper presents the design and implementation of a continuous SHM system based on dynamic properties, base accelerations, crack widths, out-of-plane rotations, and environmental data for the retrofitted church of Ku\u00f1otambo, a 17th century adobe structure, located in the Peruvian Andes. The system produces continuous hourly records. The organization, data collection, and processing of the SHM system follows different approaches and stages, concluding with the assessment of the structural and environmental conditions over time compared to predefined thresholds. The SHM system was implemented in May 2022 and is part of the Seismic Retrofitting Project of the Getty Conservation Institute. The initial results from the first twelve months of monitoring revealed seasonal fluctuations in crack widths, out-of-plane rotations, and natural frequencies, influenced by hygrothermal cycles, and an apparent positive trend, but more data are needed to justify the nature of these actions. This study emphasizes the necessity for extended data collection to establish robust correlations and refine monitoring strategies, aiming to enhance the longevity and safety of historic adobe structures under seismic risk.<\/jats:p>","DOI":"10.3390\/s24165327","type":"journal-article","created":{"date-parts":[[2024,8,19]],"date-time":"2024-08-19T06:41:31Z","timestamp":1724049691000},"page":"5327","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["An Integrated Data Acquisition Approach for the Structural Health Monitoring and Real-Time Earthquake Response Assessment of a Retrofitted Adobe Church in Peru"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4989-9267","authenticated-orcid":false,"given":"Georgios","family":"Karanikoloudis","sequence":"first","affiliation":[{"name":"Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"given":"Alberto","family":"Barontini","sequence":"additional","affiliation":[{"name":"Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1796-686X","authenticated-orcid":false,"given":"Nuno","family":"Mendes","sequence":"additional","affiliation":[{"name":"Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8459-0199","authenticated-orcid":false,"given":"Paulo B.","family":"Louren\u00e7o","sequence":"additional","affiliation":[{"name":"Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2024,8,17]]},"reference":[{"key":"ref_1","unstructured":"Cancino, C., and Lardinois, S. (2012). Seismic Retrofitting Project: Assessment of Prototype Buildings, Getty Conservation Institute. Available online: https:\/\/www.getty.edu\/conservation\/publications_resources\/pdf_publications\/assess_prototype.html."},{"key":"ref_2","unstructured":"Louren\u00e7o, P.B., Greco, F., Barontini, A., Ciocci, M.P., and Karanikoloudis, G. (2019). Seismic Retrofitting Project: Modeling of Prototype Buildings, TecMinho\u2014University of Minho. Available online: https:\/\/www.getty.edu\/conservation\/publications_resources\/pdf_publications\/modeling-prototype-buildings.html."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.conbuildmat.2015.02.010","article-title":"Post-earthquake continuous dynamic monitoring of the Gabbia Tower in Mantua, Italy","volume":"81","author":"Saisi","year":"2015","journal-title":"Constr. Build. Mater."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1080\/13632469.2017.1323048","article-title":"Earthquake-Induced Damage Detection in a Monumental Masonry Bell-Tower Using Long-Term Dynamic Monitoring Data","volume":"22","author":"Cavalagli","year":"2018","journal-title":"J. Earthq. Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.ymssp.2018.10.021","article-title":"Temperature effects on static and dynamic behavior of Consoli Palace in Gubbio, Italy","volume":"120","author":"Kita","year":"2019","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_6","unstructured":"Venanzi, I., Kita, A., Cavalagli, N., Ierimonti, L., and Ubertini, F. (2019, January 13\u201315). Continuous OMA for damage detection and localization in the Sciri Tower in Perugia, Italy. Proceedings of the 8th IOMAC\u2014International Operational Modal Analysis Conference, Copenhagen, Denmark."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2873","DOI":"10.1007\/s11012-016-0482-3","article-title":"One-year dynamic monitoring of a historic tower: Damage detection under changing environment","volume":"51","author":"Gentile","year":"2016","journal-title":"Meccanica"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Sivori, D., Ierimonti, L., Venanzi, I., Ubertini, F., and Cattari, S. (2023). An Equivalent Frame Digital Twin for the Seismic Monitoring of Historic Structures: A Case Study on the Consoli Palace in Gubbio, Italy. Buildings, 13.","DOI":"10.3390\/buildings13071840"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"134580","DOI":"10.1016\/j.conbuildmat.2023.134580","article-title":"Long-term monitoring of a masonry arch bridge to evaluate scour effects","volume":"411","author":"Borlenghi","year":"2024","journal-title":"Constr. Build. Mater."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.engstruct.2017.12.023","article-title":"Structural assessment and seismic vulnerability of earthen historic structures. Application of sophisticated numerical and simple analytical models","volume":"160","author":"Karanikoloudis","year":"2018","journal-title":"Eng. Struct."},{"key":"ref_11","unstructured":"(2024, August 13). Case Study: Ku\u00f1otambo. Seismic Retrofitting Project. Available online: www.getty.edu\/conservation\/our_projects\/field_projects\/seismic\/case_study_kunotambo.html."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Ahmadi, S.S., Karanikoloudis, G., Mendes, N., Illambas, R., and Louren\u00e7o, P.B. (2022). Appraising the Seismic Response of a Retrofitted Adobe Historic Structure, the Role of Modal Updating and Advanced Computations. Buildings, 12.","DOI":"10.3390\/buildings12111795"},{"key":"ref_13","unstructured":"Ghiassi, B., and Louren\u00e7o, P.B. (2019). Long-Term Performance and Durability of Masonry Structures. Chapter 4: Earth Masonry, Woodhead Publishing."},{"key":"ref_14","unstructured":"ICOMOS (2003). Recommendations for the Analysis, Conservation and Structural Restoration of Architectural Heritage\u2014Guidelines, International Council of Monuments and Sites."},{"key":"ref_15","unstructured":"Cardani, G., and Massetti, G.E. (2017, January 12\u201315). When the strengthening of historic masonry buildings should be carried out in different phases: The structural reinforcement and monitoring of the Lombard-Romanesque church of Saint Bassiano, in Pizzighettone (CR), Italy. Proceedings of the 3rd International Conference on Protection of Historical Constructions, Lisbon, Portugal."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1080\/15583058.2020.1802532","article-title":"Monitoring of Induced Groundborne Vibrations in Cultural Heritage Buildings: Miscellaneous Errors and Aliasing through Integration and Filtering","volume":"15","author":"Karanikoloudis","year":"2021","journal-title":"Int. J. Archit. Herit."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Cattari, S., Ottonelli, D., and Mohammadi, S. (2024). EQ-DIRECTION Procedure towards an Improved Urban Seismic Resilience: Application to the Pilot Case Study of Sanremo Municipality. Sustainability, 16.","DOI":"10.3390\/su16062501"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e2581","DOI":"10.1002\/stc.2581","article-title":"Automated data analysis for static structural health monitoring of masonry heritage structures","volume":"27","author":"Makoond","year":"2020","journal-title":"Struct. Control Health Monit."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1785\/BSSA0680051521","article-title":"Automatic earthquake recognition and timing from single traces","volume":"68","author":"Allen","year":"1978","journal-title":"Bull. Seismol. Soc. Am."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/0040-1951(91)90503-K","article-title":"Automated Phase Picker and source location algorithm for local distances using a single three-component seismic station","volume":"189","author":"Saari","year":"1991","journal-title":"Tectonophysics"},{"key":"ref_21","first-page":"ES2001","article-title":"Automated detection of mi-croearthquakes in continuous noisy records produced by local ocean bottom seismographs or coastal networks","volume":"19","author":"Krylov","year":"2019","journal-title":"Russ. J. Earth. Sci."},{"key":"ref_22","unstructured":"(2024, August 13). Earthquake Hazards Program|U.S. Geological Survey, Available online: https:\/\/earthquake.usgs.gov\/."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1002\/joc.6635","article-title":"Trends and variability of precipitation extremes in the Peruvian Altiplano (1971\u20132013)","volume":"41","author":"Huerta","year":"2021","journal-title":"Int. J. Climatol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.conbuildmat.2019.02.140","article-title":"Experimental analysis of the thermohygrometric effects on the dynamic behavior of adobe systems","volume":"208","author":"Zonno","year":"2019","journal-title":"Constr. Build. Mater."},{"key":"ref_25","unstructured":"SVS (2019). ARTeMIS Modal Pro User Manual, Release 6.0.2.0, Structural Vibration Solutions."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1088\/0964-1726\/10\/3\/303","article-title":"Modal identification of output-only systems using frequency domain decomposition","volume":"10","author":"Brincker","year":"2001","journal-title":"Smart Mater. Struct."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/16\/5327\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:38:10Z","timestamp":1760110690000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/16\/5327"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,17]]},"references-count":26,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2024,8]]}},"alternative-id":["s24165327"],"URL":"https:\/\/doi.org\/10.3390\/s24165327","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,17]]}}}