{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T23:05:03Z","timestamp":1772060703689,"version":"3.50.1"},"reference-count":43,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2024,9,20]],"date-time":"2024-09-20T00:00:00Z","timestamp":1726790400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Preservation of cultural heritage sites is of paramount importance. The ruins of Carmo Convent in Lisbon stand as a poignant reminder of the city\u2019s rich history, but challenges regarding structural integrity and safety are present in a highly populated and touristic area. In this paper, a comprehensive study of the Carmo Convent is presented, focused on non-destructive testing (NDT), structural health monitoring (SHM) and numerical modelling. Given its state of ruin and historical relevance, the study relied heavily on NDT. Additionally, a metro line passing underneath the convent raised concerns regarding potential hazards from induced vibrations. Thus, metro vibration monitoring (MVM) was implemented to assess the impact of induced vibrations on the structure. One of the challenges was the scarcity of standards specific to historic structures. However, through a combination of finite element method (FEM) and discrete element method (DEM) numerical modelling, valuable insights into the current condition of the structure were obtained. MVM revealed that the maximum velocity induced by metro activities remained within safe limits, indicating minimal impact. These results not only provide crucial information on structural preservation but also empower stakeholders to make informed decisions regarding the implementation of protective measures.<\/jats:p>","DOI":"10.3390\/s24186095","type":"journal-article","created":{"date-parts":[[2024,9,20]],"date-time":"2024-09-20T10:49:48Z","timestamp":1726829388000},"page":"6095","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Preservation and Protection of Cultural Heritage: Vibration Monitoring and Seismic Vulnerability of the Ruins of Carmo Convent (Lisbon)"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1796-686X","authenticated-orcid":false,"given":"Nuno","family":"Mendes","sequence":"first","affiliation":[{"name":"ISISE, ARISE, Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4706-1815","authenticated-orcid":false,"given":"Nicoletta","family":"Bianchini","sequence":"additional","affiliation":[{"name":"ISISE, ARISE, Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"given":"Georgios","family":"Karanikoloudis","sequence":"additional","affiliation":[{"name":"ISISE, ARISE, Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3664-0830","authenticated-orcid":false,"given":"Anna","family":"Blyth","sequence":"additional","affiliation":[{"name":"ISISE, ARISE, Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"given":"Jacopo","family":"Scacco","sequence":"additional","affiliation":[{"name":"ISISE, ARISE, Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8616-1707","authenticated-orcid":false,"given":"Luis Gerardo","family":"Flores Salazar","sequence":"additional","affiliation":[{"name":"ISISE, ARISE, Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"given":"Cassie","family":"Cullimore","sequence":"additional","affiliation":[{"name":"ISISE, ARISE, Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]},{"given":"Lavina","family":"Jain","sequence":"additional","affiliation":[{"name":"ISISE, ARISE, Department of Civil Engineering, University of Minho, 4800-058 Guimar\u00e3es, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2024,9,20]]},"reference":[{"key":"ref_1","unstructured":"Coelho, M.J., Salgado, F.M., and Rodrigues, L. (2002, January 19\u201322). The Role of Crosshole Seismic Tomography for Site Characterization and Grout Injection Evaluation on Carmo Convent Foundations. Proceedings of the 2nd International Conference on Site Charcterization (ISC\u20192), Porto, Portugal."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.engstruct.2017.03.002","article-title":"Structural safety assessment of geometrically complex masonry vaults by non-linear analysis. The Chapel of the W\u00fcrzburg Residence (Germany)","volume":"140","year":"2017","journal-title":"Eng. Struct."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"3591","DOI":"10.1007\/s10518-023-01615-z","article-title":"Evolutionary numerical model for cultural heritage structures via genetic algorithms: A case study in central Italy","volume":"22","author":"Salachoris","year":"2024","journal-title":"Bull. Earthq. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.culher.2019.09.006","article-title":"Advanced non-destructive techniques for the diagnosis of historic buildings: The Loka-Hteik-Pan temple in Bagan","volume":"43","author":"Costamagna","year":"2020","journal-title":"J. Cult. Herit."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3470","DOI":"10.3390\/heritage7070164","article-title":"Digital Tools for the Preventive Conservation of Built Heritage: The Church of Santa Ana in Seville","volume":"7","author":"Chaves","year":"2024","journal-title":"Heritage"},{"key":"ref_6","unstructured":"Elevation of Lisbon, Portugal [Internet] (2024, June 03). Worldw. Elev. Map Finder. Available online: http:\/\/elevation.maplogs.com\/poi\/lisbon_portugal.485.html."},{"key":"ref_7","unstructured":"No\u00e9, P., and Figueiredo, P. (2024, June 20). Igreja do Convento do Carmo [Internet]. Sist. Informa\u00e7\u00e3o Para o Patrim\u00f3nio Arquit, Available online: http:\/\/www.monumentos.gov.pt\/site\/app_pagesuser\/sipa.aspx?id=6521."},{"key":"ref_8","first-page":"311","article-title":"A preliminary study on the seismic behaviour of the church of Convento do Carmo in Lisbon and its confrontation with the historical perspective","volume":"15","author":"Gil","year":"1995","journal-title":"Trans. Built Environ."},{"key":"ref_9","unstructured":"(2018). Bianchini, Cullimore, Jain, Mendes, Salazar and Scacco, \u201cCarmo Convent\u2014The Church Ruins,\u201d Guimar\u00e3es, University of Minho. Report of Integrated project."},{"key":"ref_10","unstructured":"Miranda, J.M., Btll\u00f3, J., Ferreira, H., Matias, L.M., and Baptista, M.A. (2012, January 24\u201328). The 1531 Lisbon earthquake and tsunami. Proceedings of the 15th World Conference on Earthquake Engineering\u2014WCEE, Lisbon, Portugal."},{"key":"ref_11","unstructured":"(2017). Agisoft PhotoScan 1.4.0 build 5310, Agisoft LLC."},{"key":"ref_12","unstructured":"McNeel, R. (2008). Rhinoceros NURBS modeling for Windows, Robert McNeel & Associates."},{"key":"ref_13","unstructured":"Frenz, R. (2015). ReCap 360\u2014Advanced Workflows, Autodesk, Inc."},{"key":"ref_14","unstructured":"ICOMOS-ISCS (2008). Illustrated Glossary on Stone Deterioration Patterns, International Scientific Committee for Stone (ISCS)."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.conbuildmat.2012.04.018","article-title":"Sonic Impact Method\u2014A new technique for characterization of stone masonry walls","volume":"36","author":"Miranda","year":"2012","journal-title":"Constr. Build. Mater."},{"key":"ref_16","unstructured":"(2024, June 14). Norme Tecniche per le Costruzioni; Ministero delle Infrastrutture e Trasporti. Available online: https:\/\/biblus.acca.it\/download\/norme-tecniche-per-le-costruzioni-2018-ntc-2018-pdf\/."},{"key":"ref_17","unstructured":"Lourenco, P.B., and Ramos, L.F. (2017). In Situ NDT and MDT For Masonry Structures, Guimaraes."},{"key":"ref_18","unstructured":"UMacquisition (2008). Guimar\u00e3es, Portugal: Historic Masonry Structures (HMS), University of Minho."},{"key":"ref_19","unstructured":"Cunha, \u00c1., and Caetano, E. (2024, June 14). Experimental Modal Analysis of Civil Engineering Structures. Sound Vib [Internet]. Available online: https:\/\/www.academia.edu\/210199\/Experimental_Modal_Analysis_of_Civil_Engineering_Structures."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Secanellas, S.A., Gallego, J.C.L., Catal\u00e1n, G.A., Navarro, R.M., Heras, J.O., Izquierdo, M.G., Hern\u00e1ndez, M.G., and Velayos, J.J.A. (2022). An Ultrasonic Tomography System for the Inspection of Columns in Architectural Heritage. Sensors, 22.","DOI":"10.3390\/s22176646"},{"key":"ref_21","unstructured":"Thompson, D.J., Jones, C., and Gautier, P. (2009). Railway Noise and Vibration: Mechanisms, Modelling and Means of Control, Elsevier."},{"key":"ref_22","unstructured":"(1996). Mechanical Vibration and Shock\u2014Vibration of Buildings Guidelines for the Measurement of Vibrations and Their Effects on Buildings (Standard No. ISO 4866\u2014Amendment 2)."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1080\/15583058.2020.1802532","article-title":"Monitoring of Induced Groundborne Vibrations in Cultural Heritage Buildings: Miscellaneous Errors and Aliasing through Integration and Filtering","volume":"15","author":"Karanikoloudis","year":"2021","journal-title":"Int. J. Archit. Herit."},{"key":"ref_24","unstructured":"(2015). Assessment of the Influence of Impulsive Vibrations on Structures, Portuguese Standard (Standard No. NP 2074). (In Portuguese)."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1007\/s10950-019-09814-5","article-title":"Maximum intensity maps (MIM) for Portugal mainland","volume":"23","author":"Matias","year":"2019","journal-title":"J. Seism."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.engstruct.2017.03.009","article-title":"The seismic performance of stone masonry buildings in Faial island and the relevance of implementing effective seismic strengthening policies","volume":"141","author":"Maio","year":"2017","journal-title":"Eng. Struct."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/j.culher.2012.11.001","article-title":"Building typologies identification to support risk mitigation at the urban scale\u2014Case study of the old city centre of Seixal, Portugal","volume":"14","author":"Santos","year":"2013","journal-title":"J. Cult. Heritage"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1753","DOI":"10.1007\/s10518-013-9447-2","article-title":"Seismic vulnerability assessment of historical urban centres: Case study of the old city centre in Seixal, Portugal","volume":"11","author":"Ferreira","year":"2013","journal-title":"Bull. Earthq. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2307","DOI":"10.1007\/s10518-018-00527-7","article-title":"Is the use of traditional seismic strengthening strategies economically attractive in the renovation of urban cultural heritage assets in Portugal?","volume":"17","author":"Maio","year":"2018","journal-title":"Bull. Earthq. Eng."},{"key":"ref_30","unstructured":"Varum, H., Vicente, R., Rodrigues, H., and Mendes da Silva, J.A.R. (2006, January 12\u201315). Seismic Evaluation of Old Masonry Buildings: Performance and Strengthening. Proceedings of the 8th International Conference on Computational Structures Technology, Las Palmas de Gran Canaria, Spain."},{"key":"ref_31","unstructured":"Gr\u00fcnthal, G. (1998). European Macroseismic Scale 1998 (EMS-98). Cahiers du Centre Europ\u00e9en de G\u00e9odynamique et de S\u00e9ismologie 15. Cent. Eur, G\u00e9odynamique S\u00e9ismologie."},{"key":"ref_32","first-page":"220","article-title":"Discrete element modelling of the seismic behaviour of stone masonry arches","volume":"4","author":"Lemos","year":"1997","journal-title":"Comput. Methods Struct. Mason."},{"key":"ref_33","unstructured":"DIANA 10.3 (2022). Finite Element Modelling Software, DIANA FEA."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2647","DOI":"10.1007\/s10518-015-9731-4","article-title":"A method for the analysis and classification of historic masonry","volume":"13","author":"Borri","year":"2015","journal-title":"Bull. Earthq. Eng."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2295","DOI":"10.1061\/JSDEAG.0006057","article-title":"Dynamic tests and system identification of bridges","volume":"108","author":"Douglas","year":"1982","journal-title":"J. Struct. Div."},{"key":"ref_36","unstructured":"(2010). Eurocode 8: Design of Structures for Earthquake Resistance\u2014Part 1: General Rules, Seismic Actions and Rules for Buildings (Standard No. NP EN 1998\u20141: 2010)."},{"key":"ref_37","unstructured":"Itasca Consulting Group I (2016). 3DEC\u2014Three-Dimensional Distinct Element Code, Itasca Consulting Group, Inc."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.engstruct.2013.12.013","article-title":"Identification of material parameters for low bond strength masonry","volume":"60","author":"Sarhosis","year":"2014","journal-title":"Eng. Struct."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Lemos, J.V., and Campos Costa, A. (2016). Simulation of Shake Table Tests on Out-Of-Plane Masonry Buildings. Part (V): Discrete Element Approach. Int. J. Arch. Heritage, 1\u20138. Available online: https:\/\/www.tandfonline.com\/doi\/full\/10.1080\/15583058.2016.1237587.","DOI":"10.1080\/15583058.2016.1237587"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.engstruct.2014.12.014","article-title":"Influence of brick\u2013mortar interface on the mechanical behaviour of low bond strength masonry brickwork lintels","volume":"88","author":"Sarhosis","year":"2015","journal-title":"Eng. Struct."},{"key":"ref_41","unstructured":"Oliveira, D.V., Grecchi, G., Mccall, A., Noh, J., Speer, E., and Tohidi, M. (2024, July 05). Seismic Analysis of the Roman Temple of \u00c9vora, Portugal. 15 WCEE [Internet]. Lisbon. Available online: https:\/\/repositorium.sdum.uminho.pt\/bitstream\/1822\/22022\/1\/2012_Seismic analysis of the Roman Temple of \u00c9vora%2C Portugal.pdf."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"3337","DOI":"10.1016\/j.conbuildmat.2009.06.045","article-title":"Experimental characterization of stone masonry in shear and compression","volume":"23","author":"Vasconcelos","year":"2009","journal-title":"Constr. Build. Mater."},{"key":"ref_43","unstructured":"(2017). Eurocode 8: Design of Structures for Earthquake Resistance\u2014Part 3: Assessment and Retrofitting of Buildings (Standard No. NP EN 1998\u20143: 2017)."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/18\/6095\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:01:12Z","timestamp":1760112072000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/18\/6095"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,20]]},"references-count":43,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2024,9]]}},"alternative-id":["s24186095"],"URL":"https:\/\/doi.org\/10.3390\/s24186095","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,20]]}}}