{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T03:51:47Z","timestamp":1776138707022,"version":"3.50.1"},"reference-count":29,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2025,1,12]],"date-time":"2025-01-12T00:00:00Z","timestamp":1736640000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia (FCT)","award":["PTDC\/BAA-DIG\/4735\/2020"],"award-info":[{"award-number":["PTDC\/BAA-DIG\/4735\/2020"]}]},{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia (FCT)","award":["UIDB\/0536\/2020"],"award-info":[{"award-number":["UIDB\/0536\/2020"]}]},{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia (FCT)","award":["UIDP\/0536\/2020"],"award-info":[{"award-number":["UIDP\/0536\/2020"]}]},{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia (FCT)","award":["UID\/MULTI\/04046\/2021"],"award-info":[{"award-number":["UID\/MULTI\/04046\/2021"]}]},{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia (FCT)","award":["2020.09377.BD"],"award-info":[{"award-number":["2020.09377.BD"]}]},{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia (FCT)","award":["PD\/BD\/ 150393\/2019"],"award-info":[{"award-number":["PD\/BD\/ 150393\/2019"]}]},{"name":"Research Unit INESC MN through the BASE","award":["PTDC\/BAA-DIG\/4735\/2020"],"award-info":[{"award-number":["PTDC\/BAA-DIG\/4735\/2020"]}]},{"name":"Research Unit INESC MN through the BASE","award":["UIDB\/0536\/2020"],"award-info":[{"award-number":["UIDB\/0536\/2020"]}]},{"name":"Research Unit INESC MN through the BASE","award":["UIDP\/0536\/2020"],"award-info":[{"award-number":["UIDP\/0536\/2020"]}]},{"name":"Research Unit INESC MN through the BASE","award":["UID\/MULTI\/04046\/2021"],"award-info":[{"award-number":["UID\/MULTI\/04046\/2021"]}]},{"name":"Research Unit INESC MN through the BASE","award":["2020.09377.BD"],"award-info":[{"award-number":["2020.09377.BD"]}]},{"name":"Research Unit INESC MN through the BASE","award":["PD\/BD\/ 150393\/2019"],"award-info":[{"award-number":["PD\/BD\/ 150393\/2019"]}]},{"name":"PROGRAMATICO","award":["PTDC\/BAA-DIG\/4735\/2020"],"award-info":[{"award-number":["PTDC\/BAA-DIG\/4735\/2020"]}]},{"name":"PROGRAMATICO","award":["UIDB\/0536\/2020"],"award-info":[{"award-number":["UIDB\/0536\/2020"]}]},{"name":"PROGRAMATICO","award":["UIDP\/0536\/2020"],"award-info":[{"award-number":["UIDP\/0536\/2020"]}]},{"name":"PROGRAMATICO","award":["UID\/MULTI\/04046\/2021"],"award-info":[{"award-number":["UID\/MULTI\/04046\/2021"]}]},{"name":"PROGRAMATICO","award":["2020.09377.BD"],"award-info":[{"award-number":["2020.09377.BD"]}]},{"name":"PROGRAMATICO","award":["PD\/BD\/ 150393\/2019"],"award-info":[{"award-number":["PD\/BD\/ 150393\/2019"]}]},{"name":"Research Unit BIOISI","award":["PTDC\/BAA-DIG\/4735\/2020"],"award-info":[{"award-number":["PTDC\/BAA-DIG\/4735\/2020"]}]},{"name":"Research Unit BIOISI","award":["UIDB\/0536\/2020"],"award-info":[{"award-number":["UIDB\/0536\/2020"]}]},{"name":"Research Unit BIOISI","award":["UIDP\/0536\/2020"],"award-info":[{"award-number":["UIDP\/0536\/2020"]}]},{"name":"Research Unit BIOISI","award":["UID\/MULTI\/04046\/2021"],"award-info":[{"award-number":["UID\/MULTI\/04046\/2021"]}]},{"name":"Research Unit BIOISI","award":["2020.09377.BD"],"award-info":[{"award-number":["2020.09377.BD"]}]},{"name":"Research Unit BIOISI","award":["PD\/BD\/ 150393\/2019"],"award-info":[{"award-number":["PD\/BD\/ 150393\/2019"]}]},{"name":"doctoral grants","award":["PTDC\/BAA-DIG\/4735\/2020"],"award-info":[{"award-number":["PTDC\/BAA-DIG\/4735\/2020"]}]},{"name":"doctoral grants","award":["UIDB\/0536\/2020"],"award-info":[{"award-number":["UIDB\/0536\/2020"]}]},{"name":"doctoral grants","award":["UIDP\/0536\/2020"],"award-info":[{"award-number":["UIDP\/0536\/2020"]}]},{"name":"doctoral grants","award":["UID\/MULTI\/04046\/2021"],"award-info":[{"award-number":["UID\/MULTI\/04046\/2021"]}]},{"name":"doctoral grants","award":["2020.09377.BD"],"award-info":[{"award-number":["2020.09377.BD"]}]},{"name":"doctoral grants","award":["PD\/BD\/ 150393\/2019"],"award-info":[{"award-number":["PD\/BD\/ 150393\/2019"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Point-of-care (PoC) devices offer a promising solution for fast, portable, and easy-to-use diagnostics. These characteristics are particularly relevant in agrifood fields like viticulture where the early detection of plant stresses is crucial to crop yield. Microfluidics, with its low reagent volume requirements, is well-suited for such applications. Self-driven microfluidic devices, which rely on capillary forces for fluid motion, offer an attractive alternative by eliminating the need for external pumps and complex fluid control systems. However, traditional microfluidic prototyping materials like polydimethylsiloxane (PDMS) present challenges due to their hydrophobic nature. This paper presents the development of a reusable, portable, capillary-driven microfluidic platform based on a PDMS-PEG (polyethylene glycol) copolymer designed for the rapid low-cost detection of abscisic acid (ABA), a key biomarker for the onset of ripening of non-climacteric fruits and drought stress in vines. By employing passive fluid transport mechanisms, such as capillary-driven sequential flow, this platform enables precise biological and chemical screenings while maintaining portability and ease of use. A simplified field-ready sample processing method is used to prepare the grapes for analysis.<\/jats:p>","DOI":"10.3390\/s25020411","type":"journal-article","created":{"date-parts":[[2025,1,13]],"date-time":"2025-01-13T06:42:15Z","timestamp":1736750535000},"page":"411","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A Reusable Capillary Flow-Driven Microfluidic System for Abscisic Acid Detection Using a Competitive Immunoassay"],"prefix":"10.3390","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1000-1181","authenticated-orcid":false,"given":"Cristiana","family":"Domingues","sequence":"first","affiliation":[{"name":"Instituto de Engenharia de Sistemas e Computadores\u2013Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-5287-6294","authenticated-orcid":false,"given":"Marta S. C.","family":"Rodrigues","sequence":"additional","affiliation":[{"name":"Instituto de Engenharia de Sistemas e Computadores\u2013Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal"}]},{"given":"Pedro G. M.","family":"Condelipes","sequence":"additional","affiliation":[{"name":"Instituto de Engenharia de Sistemas e Computadores\u2013Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal"}]},{"given":"Ana Margarida","family":"Fortes","sequence":"additional","affiliation":[{"name":"Instituto de Biossistemas e Ci\u00eancias Integrativas (BioISI), Faculdade de Ci\u00eancias de Lisboa, Universidade de Lisboa, 1749-016 Lisbon, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5306-4409","authenticated-orcid":false,"given":"Virginia","family":"Chu","sequence":"additional","affiliation":[{"name":"Instituto de Engenharia de Sistemas e Computadores\u2013Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5677-3024","authenticated-orcid":false,"given":"Jo\u00e3o Pedro","family":"Conde","sequence":"additional","affiliation":[{"name":"Instituto de Engenharia de Sistemas e Computadores\u2013Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal"},{"name":"Department of Bioengineering, Instituto Superior T\u00e9cnico, Avenida Rovisco Pais, 1049-001 Lisbon, Portugal"}]}],"member":"1968","published-online":{"date-parts":[[2025,1,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1634","DOI":"10.1039\/D0LC01156H","article-title":"Point-of-care testing detection methods for COVID-19","volume":"21","author":"Song","year":"2021","journal-title":"Lab Chip"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Manessis, G., Gelasakis, A.I., and Bossis, I. (2022). Point-Of-Care Diagnostics for Farm Animal Diseases: From Biosensors to Integrated Lab-On-Chip Devices. Biosensors, 12.","DOI":"10.3390\/bios12070455"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"107248","DOI":"10.1016\/j.microc.2022.107248","article-title":"State-of-the-art cancer biomarker detection by portable (Bio) sensing technology: A critical review","volume":"177","author":"Sohrabi","year":"2022","journal-title":"Microchem. J."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Buja, I., Sabella, E., Monteduro, A.G., Chiriac\u00f2, M.S., De Bellis, L., Luvisi, A., and Maruccio, G. (2021). Advances in plant disease detection and monitoring: From traditional assays to in-field diagnostics. Sensors, 21.","DOI":"10.3390\/s21062129"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1039\/c0lc00230e","article-title":"Microfluidics for food, agriculture and biosystems industries","volume":"11","author":"Neethirajan","year":"2011","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"26388","DOI":"10.1109\/JSEN.2024.3423678","article-title":"A Versatile Platform for Point-of-Care Detection of Molecular Biomarkers","volume":"24","author":"Silva","year":"2024","journal-title":"IEEE Sens. J."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1038\/nm.2408","article-title":"Microfluidics-based diagnostics of infectious diseases in the developing world","volume":"17","author":"Chin","year":"2011","journal-title":"Nat. Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"3","DOI":"10.2147\/AHCT.S94024","article-title":"Microfluidics technology: Future prospects for molecular diagnostics","volume":"3","author":"Lo","year":"2017","journal-title":"Adv. Health Care Technol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1038\/nature05058","article-title":"The origins and the future of microfluidics","volume":"442","author":"Whitesides","year":"2006","journal-title":"Nature"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1146\/annurev.bioeng.4.112601.125916","article-title":"Physics and Applications of Microfluidics in Biology","volume":"4","author":"Beebe","year":"2002","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/j.plantsci.2019.01.024","article-title":"The study of hormonal metabolism of Trincadeira and Syrah cultivars indicates new roles of salicylic acid, jasmonates, ABA and IAA during grape ripening and upon infection with Botrytis cinerea","volume":"283","author":"Coelho","year":"2019","journal-title":"Plant Sci."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Domingues, C., Meirinho, R., Rodrigues, R.G., Fortes, A.M., Chu, V., and Conde, J.P. (2024). Competitive Immunoassay in a Microfluidic Biochip for In-Field Detection of Abscisic Acid in Grapes. Biosensors, 14.","DOI":"10.3390\/bios14030123"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1007\/s00425-002-0866-6","article-title":"A multiplex GC-MS\/MS technique for the sensitive and quantitative single-run analysis of acidic phytohormones and related compounds, and its application to Arabidopsis thaliana","volume":"216","author":"Weiler","year":"2002","journal-title":"Planta"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"5743","DOI":"10.1109\/JSEN.2020.3041266","article-title":"Optical Aptamer-Based Sensors for Detecting Plant Hormones","volume":"21","author":"Feng","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"136831","DOI":"10.1016\/j.snb.2024.136831","article-title":"Microfluidic capillary platform with hydrophilic PDMS for point-of-care immunoassays","volume":"423","author":"Condelipes","year":"2025","journal-title":"Sens. Actuators B Chem."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Yang, S.-M., Lv, S., Zhang, W., and Cui, Y. (2022). Microfluidic Point-of-Care (POC) Devices in Early Diagnosis: A Review of Opportunities and Challenges. Sensors, 22.","DOI":"10.3390\/s22041620"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"6139","DOI":"10.1021\/ac0261449","article-title":"Autonomous microfluidic capillary system","volume":"74","author":"Juncker","year":"2002","journal-title":"Anal. Chem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"3330","DOI":"10.1039\/b906523g","article-title":"Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates","volume":"9","author":"Gervais","year":"2009","journal-title":"Lab Chip"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.bios.2011.06.016","article-title":"Capillary-driven multiparametric microfluidic chips for one-step immunoassays","volume":"27","author":"Gervais","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3563","DOI":"10.1002\/elps.200305584","article-title":"Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies","volume":"24","author":"Sia","year":"2003","journal-title":"Electrophoresis"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1007\/s10544-005-6070-2","article-title":"Characterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro\/Nanosystems","volume":"7","author":"Mata","year":"2005","journal-title":"Biomed. Microdevices"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1039\/B609813D","article-title":"Capillary pumps for autonomous capillary systems","volume":"7","author":"Zimmermann","year":"2007","journal-title":"Lab Chip"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"126647","DOI":"10.1016\/j.snb.2019.126647","article-title":"Bin An integrated self-driven microfluidic device for rapid detection of the influenza A (H1N1) virus by reverse transcription loop-mediated isothermal amplification","volume":"296","author":"Ma","year":"2019","journal-title":"Sens. Actuators B Chem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1039\/C2LC41083D","article-title":"Control of sequential fluid delivery in a fully autonomous capillary microfluidic device","volume":"13","author":"Novo","year":"2013","journal-title":"Lab Chip"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"151704","DOI":"10.1016\/j.apsusc.2021.151704","article-title":"Microscale investigation on the wettability and bonding mechanism of oxygen plasma-treated PDMS microfluidic chip","volume":"574","author":"Jiang","year":"2022","journal-title":"Appl. Surf. Sci."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1775","DOI":"10.1002\/elps.200700561","article-title":"Chemical cytometry on microfluidic chips","volume":"29","author":"Yan","year":"2008","journal-title":"Electrophoresis"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1500","DOI":"10.1039\/b901651a","article-title":"Surface modification of PDMS by gradient-induced migration of embedded Pluronic","volume":"9","author":"Wu","year":"2009","journal-title":"Lab Chip"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH Image to ImageJ: 25 years of image analysis","volume":"9","author":"Schneider","year":"2012","journal-title":"Nat. Methods"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1093\/chromsci\/bmab114","article-title":"A Novel, Simple Rapid Reverse-Phase HPLC-DAD Analysis, for the Simultaneous Determination of Phenolic Compounds and Abscisic Acid Commonly Found in Foodstuff and Beverages","volume":"60","author":"Whelan","year":"2022","journal-title":"J. Chromatogr. Sci."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/2\/411\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T10:27:09Z","timestamp":1759919229000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/2\/411"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,12]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,1]]}},"alternative-id":["s25020411"],"URL":"https:\/\/doi.org\/10.3390\/s25020411","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,12]]}}}