{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T15:49:20Z","timestamp":1775144960289,"version":"3.50.1"},"reference-count":24,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2020,9,23]],"date-time":"2020-09-23T00:00:00Z","timestamp":1600819200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["SFRH\/BD\/121549\/2016"],"award-info":[{"award-number":["SFRH\/BD\/121549\/2016"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sustainability"],"abstract":"<jats:p>Measuring moisture content in building materials is essential both for professional practice and for research. However, this is a very complex task, especially when long-term minor destructive measurements are desired. The time-domain reflectometry (TDR) technique is commonly used for soil moisture measurements, but its application in construction materials is considered a relatively new method, particularly for low-porosity building materials. The major obstacles to its current use in construction materials are (1) the difficulty of ensuring good contact between the TDR probe and the material, and (2) the lack of appropriate conversion functions between the measured relative permittivity and the moisture content of building materials. This paper intends to contribute to overcoming these difficulties by explaining in detail all the required steps to monitor moisture content in real-scale limestone walls. For that, a device is presented to guarantee the correct installation of the TDR probes on the walls, and a calibration procedure through the gravimetric method is proposed to avoid the use of an unsuitable calibration function developed for soil moisture measurements. In addition, the importance of the individual probe calibration is discussed, as well as TDR advantages and disadvantages for construction materials. The results obtained so far reveal that the TDR technique is suitable to detect moisture content variations in limestone, which is a low-porosity building material.<\/jats:p>","DOI":"10.3390\/su12197855","type":"journal-article","created":{"date-parts":[[2020,9,24]],"date-time":"2020-09-24T02:56:43Z","timestamp":1600916203000},"page":"7855","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Is the Time-Domain Reflectometry (TDR) Technique Suitable for Moisture Content Measurement in Low-Porosity Building Materials?"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8592-7387","authenticated-orcid":false,"given":"Teresa Stingl","family":"Freitas","sequence":"first","affiliation":[{"name":"Construct-LFC, Faculty of Engineering, University of Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal"}]},{"given":"Ana Sofia","family":"Guimar\u00e3es","sequence":"additional","affiliation":[{"name":"Construct-LFC, Faculty of Engineering, University of Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal"}]},{"given":"Staf","family":"Roels","sequence":"additional","affiliation":[{"name":"KU Leuven, Department of Civil Engineering, Building Physics Section, Kasteelpark Arenberg 40 Bus 2447, 3001 Haverlee, Belgium"}]},{"given":"Vasco","family":"Peixoto de Freitas","sequence":"additional","affiliation":[{"name":"Construct-LFC, Faculty of Engineering, University of Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9031-7690","authenticated-orcid":false,"given":"Andrea","family":"Cataldo","sequence":"additional","affiliation":[{"name":"Department of Innovation Engineering, University of Salento, Via Monteroni, 73100 Lecce, Italy"}]}],"member":"1968","published-online":{"date-parts":[[2020,9,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1177\/0143624407084184","article-title":"Moisture measurement in building materials: An overview of current methods and new approaches","volume":"28","author":"Phillipson","year":"2007","journal-title":"Build. Serv. Eng. Res. Technol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1080\/15583050701476754","article-title":"Measurement Methods of Moisture in Building Envelopes\u2014A Literature Review","volume":"1","author":"Said","year":"2007","journal-title":"Int. J. Arch. Heritage"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.measurement.2008.08.011","article-title":"Time-domain reflectometry method and its application for measuring moisture content in porous materials: A review","volume":"42","year":"2009","journal-title":"Measurement"},{"key":"ref_4","first-page":"1","article-title":"Advances in Reflectometric Sensing for Industrial Applications","volume":"2","author":"Cataldo","year":"2016","journal-title":"Synth. Lect. Emerg. Eng. Technol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.6028\/jres.056.001","article-title":"Dielectric constant of water from 0 to 100 C","volume":"56","author":"Malmberg","year":"1956","journal-title":"J. Res. Natl. Inst. Stand. Technol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1029\/1998WR900006","article-title":"Temperature effects on soil bulk dielectric permittivity measured by time domain reflectometry: Experimental evidence and hypothesis development","volume":"35","author":"Wraith","year":"1999","journal-title":"Water Resour. Res."},{"key":"ref_7","first-page":"13","article-title":"Electrical and dielectric properties of water","volume":"13","author":"Freitas","year":"2017","journal-title":"Sci. Plena"},{"key":"ref_8","first-page":"63","article-title":"Electric properties of water. New experimental data in the 5HZ-13MHZ frequency range","volume":"52","author":"Rusiniak","year":"2004","journal-title":"Acta Geophys. Pol."},{"key":"ref_9","unstructured":"(2019, January 24). Instruction Manual\u2013TDR Probes CS605, CD610, CS630, CS635, CS640, CS645 (Revision:9\/13). Available online: https:\/\/s.campbellsci.com\/documents\/ca\/manuals\/tdr-probes-manual.pdf."},{"key":"ref_10","first-page":"179","article-title":"Sensitivity range determination of surface TDR probes","volume":"35","author":"Suchorab","year":"2009","journal-title":"Environ. Prot. Eng."},{"key":"ref_11","first-page":"1661","article-title":"Application of Time-Domain Reflectometry for Measurement of Moisture Profiles in a Drying Experiment","volume":"33","author":"Mihulka","year":"2011","journal-title":"Int. J. Thermophys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1190\/1.1437539","article-title":"Estimation of permeable pathways and water content using tomographic radar data","volume":"16","author":"Hubbard","year":"1997","journal-title":"Lead. Edge"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Martinez, A., and Bymes, A.P. (2019, January 24). Modelling Dielectric-Constant Values of Geologic Materials: An Aid to Ground-Penetrating Radar Data Collection and Interpretation. Available online: http:\/\/www.kgs.ku.edu\/Current\/2001\/martinez\/martinez.pdf.","DOI":"10.17161\/cres.v0i247.11831"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1732","DOI":"10.3923\/jas.2008.1732.1737","article-title":"Determination of Moisture Content of Hygroscopic Building Materials Using Time Domain Reflectometry","volume":"8","author":"Pavlik","year":"2008","journal-title":"J. Appl. Sci."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1556\/Pollack.4.2009.2.8","article-title":"Analysis of dielectric mixing models for the moisture assessment of porous building materials","volume":"4","author":"Fiala","year":"2009","journal-title":"Pollack Period."},{"key":"ref_16","first-page":"171","article-title":"Laboratory measurements of moisture in a model red-brick wall using the surface TDR probe","volume":"7","author":"Suchorab","year":"2013","journal-title":"Proc. Ecopole"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"04016262","DOI":"10.1061\/(ASCE)MT.1943-5533.0001794","article-title":"Use of TDR to Compare Rising Damp in Three Tuff Walls Made with Different Mortars","volume":"29","author":"Agliata","year":"2017","journal-title":"J. Mater. Civ. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1177\/0143624408092423","article-title":"Suitability of time domain reflectometry for monitoring moisture in building materials","volume":"29","author":"Phillipson","year":"2008","journal-title":"Build. Serv. Eng. Res. Technol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1179\/sic.2008.53.Supplement-2.33","article-title":"Techniques for monitoring moisture in walls","volume":"53","author":"Pinchin","year":"2008","journal-title":"Stud. Conserv."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1177\/1744259106064356","article-title":"Determination of Moisture Diffusivity using the Time Domain Reflectometry (TDR) Method","volume":"30","author":"Sobczuk","year":"2006","journal-title":"J. Build. Phys."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Cataldo, A., De Benedetto, E., Cannazza, G., Piuzzi, E., and Pittella, E. (2017, January 22\u201325). Moisture content monitoring of construction materials: From in-line production through on-site applications. Proceedings of the 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Turin, Italy.","DOI":"10.1109\/I2MTC.2017.7969762"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/j.buildenv.2005.07.034","article-title":"Treatment of rising damp in historical buildings: Wall base ventilation","volume":"42","author":"Torres","year":"2007","journal-title":"Build. Environ."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2079","DOI":"10.1007\/s00231-012-1053-3","article-title":"Rising damp in building walls: The wall base ventilation system","volume":"48","author":"Azevedo","year":"2012","journal-title":"Heat Mass Transf."},{"key":"ref_24","unstructured":"(2020, March 05). Instruction Manual-TDR200 (Revision 4\/17). Available online: https:\/\/s.campbellsci.com\/documents\/ca\/manuals\/tdr200_man.pdf."}],"container-title":["Sustainability"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2071-1050\/12\/19\/7855\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:12:49Z","timestamp":1760177569000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2071-1050\/12\/19\/7855"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,23]]},"references-count":24,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2020,10]]}},"alternative-id":["su12197855"],"URL":"https:\/\/doi.org\/10.3390\/su12197855","relation":{},"ISSN":["2071-1050"],"issn-type":[{"value":"2071-1050","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,23]]}}}