{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T14:18:18Z","timestamp":1780928298448,"version":"3.54.1"},"reference-count":25,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2025,1,17]],"date-time":"2025-01-17T00:00:00Z","timestamp":1737072000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sustainability"],"abstract":"<jats:p>The aging process of bourbon within rickhouses is influenced by various environmental factors, including temperature, humidity, air flow, and air quality. Most rickhouses are not climate-controlled, and natural ventilation is a major contributor to airflow. The corrosion of the steel hoops on bourbon barrels occurs due to the presence of ethyl alcohol vapors and has become an issue for the distilling industry. The loss of a barrel or product is the loss of all of the energy and materials that went into the distillation, as well as the removal of the barrel from the secondary market. Despite the large economic and sustainability impact of barrel losses, there is limited published research with respect to corrective actions. This paper investigates airflow patterns within a bourbon rickhouse using a combination of differential pressure surveys and smoke tracing techniques to understand how natural ventilation impacts the aging process and potential for corrosion. A newly constructed rickhouse was surveyed using a micro-manometer to measure differential pressure and a sheet laser with smoke to visualize airflow. This study revealed significant zones of stagnant air and minimal recirculation within the ricks, which are the structures that hold the bourbon barrels. Airflow was found to primarily enter through windows and ground vents, moving along the walkways before exiting through other openings, with minimal penetration into the ricks. Differential pressure measurements generally indicated a lack of significant airflow, while smoke tracing showed that air entering the side of the building does not circulate into the ricks. This lack of airflow promotes the separation of ethyl alcohol vapor due to density, leading to its accumulation on the floor of the ricks. The findings of this study highlight the need to consider how rickhouse design impacts airflow and the potential for the corrosion of metal hoops on barrels due to the presence of ethyl alcohol vapor, and provide insight into optimizing the ventilation of rickhouses for more efficient and sustainable bourbon maturation.<\/jats:p>","DOI":"10.3390\/su17020699","type":"journal-article","created":{"date-parts":[[2025,1,20]],"date-time":"2025-01-20T12:32:52Z","timestamp":1737376372000},"page":"699","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Reducing Product Loss Through Ventilation in Bourbon Maturation Warehouses"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6529-137X","authenticated-orcid":false,"given":"Steven J.","family":"Schafrik","sequence":"first","affiliation":[{"name":"Department of Mining Engineering, University of Kentucky, Lexington, KY 40506, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-5374-5960","authenticated-orcid":false,"given":"Michael W.","family":"Long","sequence":"additional","affiliation":[{"name":"Department of Mining Engineering, University of Kentucky, Lexington, KY 40506, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4124-8814","authenticated-orcid":false,"given":"Zachary E.","family":"Wedding","sequence":"additional","affiliation":[{"name":"Department of Mining Engineering, University of Kentucky, Lexington, KY 40506, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-8957-8143","authenticated-orcid":false,"given":"Benjamin M.","family":"Diddle","sequence":"additional","affiliation":[{"name":"Department of Mining Engineering, University of Kentucky, Lexington, KY 40506, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9799-4114","authenticated-orcid":false,"given":"Zach","family":"Agioutantis","sequence":"additional","affiliation":[{"name":"Department of Mining Engineering, University of Kentucky, Lexington, KY 40506, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,1,17]]},"reference":[{"key":"ref_1","unstructured":"Russell, I., Stewart, G.G., and Kellershohn, J. (2022). \u2018Chapter 16\u2014Maturation\u2019. Whisky and Other Spirits, Elsevier Ltd.. [3rd ed.]."},{"key":"ref_2","unstructured":"Piggott, J.R., Sharp, R., and Duncan, R.E.B. (1989). Cask quality and warehouse conditions. The Science and Technology of Whiskies, Longman Scientific & Technical; J. Wiley."},{"key":"ref_3","unstructured":"Campari Group (2024, November 11). Sustainability Report. Available online: https:\/\/www.camparigroup.com\/en\/page\/sustainability."},{"key":"ref_4","unstructured":"Suntory (2024, November 11). Sustainability Report. Available online: https:\/\/www.suntoryglobalspirits.com\/news\/suntory-global-spirits-releases-2023-sustainability-report."},{"key":"ref_5","unstructured":"United Nations (2024, December 03). The 17 Goals|Sustainable Development. United Nations. Available online: https:\/\/sdgs.un.org\/goals."},{"key":"ref_6","first-page":"82","article-title":"Some old lessons distilled","volume":"50","author":"Lstiburek","year":"2008","journal-title":"ASHRAE J."},{"key":"ref_7","first-page":"12","article-title":"The effects of temperature on major beer compounds during barrel maturation","volume":"51","author":"Browning","year":"2014","journal-title":"Master Brew. Assoc. Am."},{"key":"ref_8","first-page":"40","article-title":"The Chemistry of Bourbon","volume":"117","author":"Demoranville","year":"2021","journal-title":"Chem. Eng. Prog."},{"key":"ref_9","unstructured":"Macy, T. (2024, November 11). Barrel Maturation. Tom Macy Cocktails. Available online: https:\/\/www.tommacy.com\/barrelmaturation."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.promfg.2018.06.026","article-title":"Testing Lora for food applications-Example application for airflow measurements inside cooled warehouses with apples","volume":"24","author":"Jedermann","year":"2018","journal-title":"Procedia Manuf."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"109746","DOI":"10.1016\/j.jfoodeng.2019.109746","article-title":"Airflow distribution in an apple storage room","volume":"269","author":"Praeger","year":"2020","journal-title":"J. Food Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1016\/j.enbuild.2014.10.040","article-title":"Air infiltration assessment for industrial buildings","volume":"86","author":"Brinks","year":"2015","journal-title":"Energy Build."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.egypro.2017.03.1124","article-title":"Air permeability measurements in a Deep Freeze Warehouse","volume":"112","author":"Iordache","year":"2017","journal-title":"Energy Procedia"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/S0032-5910(00)00265-5","article-title":"Visualization of flow structures inside a circulating fluidized bed by means of laser sheet and image processing","volume":"114","author":"Lackermeier","year":"2001","journal-title":"Powder Technol."},{"key":"ref_15","unstructured":"Xilin, W., Quanlin, F., and Yincheng, G. (1997, January 7\u201311). Visualization of two-phase turbulent jet coherent structures. Proceedings of the International Symposium on Multiphase Flow (ISMF\u201997), Beijing, China."},{"key":"ref_16","unstructured":"Chlebanowski, J.S., and Bodapati, S. (1988). Flow Visualization by Laser Sheet. [Ph.D. Thesis, Naval Postgraduate School]."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Merzkirch, W., and Gersten, K. (1987). Techniques of Flow Visualization, Advisory Group for Aerospace Research and Development, NATO. Technical Report AGARD-AG-302.","DOI":"10.1016\/B978-0-08-050658-6.50007-2"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.ast.2018.08.017","article-title":"Effect of low dorsal fin on the breakdown of vortices over a slender delta wing","volume":"81","author":"Meng","year":"2018","journal-title":"Aerosp. Sci. Technol."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Walker, I.S., Claret, V., and Smith, B. (2006). Laser Sheet Light Flow Visualization for Evaluating Room Air Flows from Registers, Technical Report; US Department of Energy, Office of Scientific and Technical Information.","DOI":"10.2172\/924836"},{"key":"ref_20","first-page":"74","article-title":"Vortex Formation in Incompressible Axisymmetric Free Jets","volume":"13","author":"Woiski","year":"2014","journal-title":"Rev. De Eng. T\u00e9rmica"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/S0010-938X(03)00130-6","article-title":"Electrochemical impedance study on galvanized steel corrosion under cyclic wet\u2013dry conditions\u2014Influence of time of wetness","volume":"46","author":"Yadav","year":"2004","journal-title":"Corros. Sci."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1007\/s11665-010-9692-3","article-title":"Corrosion behavior of mild carbon steel in ethanolic solutions","volume":"20","author":"Bhola","year":"2011","journal-title":"J. Mater. Eng. Perform."},{"key":"ref_23","unstructured":"McPherson, M.J. (2009). Subsurface Ventilation Engineering, Mine Ventilation Services Inc.. [2nd ed.]."},{"key":"ref_24","unstructured":"TSI (2016). DP-Calc\u2122 Micromanometer Model 5815 Operation and Service Manual, TSI."},{"key":"ref_25","unstructured":"ASHRAE (1981). Fundamentals: An Instrument of Service Prepared for the Profession Containing a Technical Data Section of Reference Material Pertaining to Systems for Heating, Refrigerating, Ventilating, and Air Conditioning, American Society of Heating Refrigerating and Air-Conditioning Engineers. Handbook."}],"container-title":["Sustainability"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2071-1050\/17\/2\/699\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T10:30:29Z","timestamp":1759919429000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2071-1050\/17\/2\/699"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,17]]},"references-count":25,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,1]]}},"alternative-id":["su17020699"],"URL":"https:\/\/doi.org\/10.3390\/su17020699","relation":{},"ISSN":["2071-1050"],"issn-type":[{"value":"2071-1050","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,17]]}}}