{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T13:43:11Z","timestamp":1788183791304,"version":"build-2803163510"},"reference-count":28,"publisher":"The Editorial Committee of Annals of Vascular Diseases","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Annals of Vascular Diseases","Ann Vasc Dis","AVD"],"published-print":{"date-parts":[[2022,6,25]]},"DOI":"10.3400\/avd.oa.22-00037","type":"journal-article","created":{"date-parts":[[2022,5,10]],"date-time":"2022-05-10T22:09:29Z","timestamp":1652220569000},"page":"94-100","source":"Crossref","is-referenced-by-count":10,"title":["Water Distribution Changes in Complex Decongestive Treatment for Leg Lymphedema: Quantitative Evaluation by Direct Segmental Multi-Frequency Bioimpedance Analysis"],"prefix":"10.3400","volume":"15","author":[{"given":"Masahiro","family":"Toshima","sequence":"first","affiliation":[{"name":"Department of Vascular Surgery, Kamiichi General Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshihisa","family":"Morino","sequence":"additional","affiliation":[{"name":"Department of Rehabilitation, Kamiichi General Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1983","reference":[{"key":"1","unstructured":"1) Fu MR, Cleland CM, Guth AA, et al. L-Dex ratio in detecting breast cancer-related lymphedema: reliability, sensitivity, and specifity. Lymphology 2013; <b>46<\/b>: 85-96."},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Hidding JT, Viehoff PB, Beurskens CH, et al. Measurement properties of instruments for measuring of lymphedema: systematic review. Phys Ther 2016; <b>96<\/b>: 1965-81.","DOI":"10.2522\/ptj.20150412"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Kim L, Jeon JY, Sung IY, et al. Prediction of treatment outcome with bioimpedance measurements in breast cancer related lymphedema patients. Ann Rehabil Med 2011; <b>35<\/b>: 687-93.","DOI":"10.5535\/arm.2011.35.5.687"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Kim H, Choi GH, Shim KE, et al. Changes in bioimpedance analysis components before and after hemodialysis. Kidney Res Clin Pract 2018; <b>37<\/b>: 393-403.","DOI":"10.23876\/j.krcp.18.0035"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Malbrain ML, Huygh J, Dabrowski W, et al. The use of bio-electrical impedance analysis (BIA) to guide fluid management, resuscitation and deresuscitation in critically ill patients: a bench-to-bedside review. Anaesthesiol Intensive Ther 2014; <b>46<\/b>: 381-91.","DOI":"10.5603\/AIT.2014.0061"},{"key":"6","unstructured":"6) Watanabe R, Miura A, Inoue M, et al. Evaluation of leg edema using a multifrequency impedance meter in patients with lymphatic obstruction. Lymphology 1989; <b>22<\/b>: 85-92."},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Ward LC, Bunce IH, Cornish BH, et al. Multi-frequency bioelectrical impedance augments the diagnosis and management of lymphedema in post-mastectomy patients. Eur J Clin Invest 1992; <b>22<\/b>: 751-4.","DOI":"10.1111\/j.1365-2362.1992.tb01440.x"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Cornish BH, Thomas BJ, Ward LC, et al. A new technique for the quantification of peripheral edema with application in both unilateral and bilateral cases. Angiology 2002; <b>53<\/b>: 41-7.","DOI":"10.1177\/000331970205300106"},{"key":"9","unstructured":"9) Yoshimura Y. Evaluation method of body composition and historical transition. Jpn J Clin Nutr 2016; <b>128<\/b>: 146-52. (in Japanese)"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Ling CH, de Craen AJ, Slagboom PE, et al. Accuracy of direct segmental multi-frequency bioimpedance analysis in the assessment of total body and segmental body composition in middle-aged adult population. Clin Nutr 2011; <b>30<\/b>: 610-5.","DOI":"10.1016\/j.clnu.2011.04.001"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Kim M, Shinkai S, Murayama H, et al. Comparison of segmental multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for the assessment of body composition in a community-dwelling older population. Geriatr Gerontol Int 2015; <b>15<\/b>: 1013-22.","DOI":"10.1111\/ggi.12384"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Cha K, Chertow GM, Gonzalez J, et al. Multifrequency bioelectrical impedance estimates the distribution of body water. J Appl Physiol 1995; <b>79<\/b>: 1316-9.","DOI":"10.1152\/jappl.1995.79.4.1316"},{"key":"13","unstructured":"13) Cha K, Shin S, Shon C, et al. Evaluation of segmental bioelectrical impedance analysis (SBIA) for measuring muscle distribution. J ICHPER SD-ASIA 1997: 11-4."},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Niimi K, Hirai H, Iwata H, et al. Ultrasonographic findings and the clinical results of treatment for lymphedema. Jpn J Phlebol 2013; <b>24<\/b>: 287-94. (in Japanese)","DOI":"10.7134\/phlebol.24.287"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Antonio J, Kenyon M, Ellerbroek A, et al. Comparison of dual-energy X-ray absorptiometry (DXA) versus a multifrequency bioelectrical impedance (InBody 770) device for body composition assessment after a 4-week hypoenergetic diet. J Funct Morphol Kinesiol 2019; <b>4<\/b>: 23-32.","DOI":"10.3390\/jfmk4020023"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Ward LC, Czerniec S, Kilbreath SL. Quantitative bioimpedance spectroscopy for the assessment of lymphedema. Breast Cancer Res Treat 2009; <b>117<\/b>: 541-7.","DOI":"10.1007\/s10549-008-0258-0"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Ogawa Y. Conservative treatment of lymphedema based on evidence. Jpn J Phlebol 2013; <b>24<\/b>: 447-56. (in Japanese)","DOI":"10.7134\/phlebol.414"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Wang ZM, Pierson RN Jr, Heymsfield SB. The five-level model: a new approach to organizing body-composition research. Am J Clin Nutr 1992; <b>56<\/b>: 19-28.","DOI":"10.1093\/ajcn\/56.1.19"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Ohashi Y, Joki N, Yamazaki K, et al. Changes in the fluid volume balance between intra- and extracellular water in a sample of Japanese adults aged 15-88 yr old: a cross-sectional study. Am J Physiol Renal Physiol 2018; <b>314<\/b>: 614-22.","DOI":"10.1152\/ajprenal.00477.2017"},{"key":"20","unstructured":"20) Tsutsumi R, Oto J, Fukunaga K, et al. Usefulness and limitation of body composition assessment in critical patients. J-JSPEN 2016; <b>31<\/b>: 803-6. (in Japanese)"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Sasaki N, Ueno K, Shiraishi T, et al. The optimal ratio of extracellular water to total body water (ECW\/TBW) determined by bioelectrical impedance analysis (BIA) for setting dry weight in hemodialysis patients. J Jpn Soc Dial Ther 2008; <b>41<\/b>: 723-30. (in Japanese)","DOI":"10.4009\/jsdt.41.723"},{"key":"22","unstructured":"22) Sato K. Complex decongestive physiotherapy (CDP). Nihon Rinsho 2005; <b>63<\/b>: 144-53. (in Japanese)"},{"key":"23","unstructured":"23) Preston NJ, Seers K, Mortimer PS. Physical therapies for reducing and controlling lymphedema of the limbs. Cochrane Database Syst Rev 2008; issue 3."},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Tan IC, Maus EA, Rasmussen JC, et al. Assessment of lymphatic contractile function after manual lymphatic drainage using near-infrared fluorescence imaging. Arch Phys Med Rehabil 2011; <b>92<\/b>: 756-64.e1.","DOI":"10.1016\/j.apmr.2010.12.027"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) De Vrieze T, Vos L, Gebruers N, et al. Protocol of a randomized controlled trial regarding the effectiveness of fluoroscopy-guided manual lymph drainage for the treatment of breast cancer-related lymphedema (EF for T-BCRL trial). Eur J Obstet Gynecol Reprod Biol 2018; <b>221<\/b>: 177-88.","DOI":"10.1016\/j.ejogrb.2017.12.023"},{"key":"26","unstructured":"26) Miranda F Jr, Perez MC, Castiglioni ML, et al. Effect of sequential intermittent pneumatic compression on both leg lymphedema volume and on lymph transport as semi-quantitatively evaluated by lymphoscintigraphy. Lymphology 2001; <b>34<\/b>: 135-41."},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Donahue PM, Crescenzi R, Scott AO, et al. Bilateral changes in deep tissue environment after manual lymphatic drainage in patients with breast cancer treatment-related lymphedema. Lymphat Res Biol 2017; <b>15<\/b>: 45-56.","DOI":"10.1089\/lrb.2016.0020"},{"key":"28","unstructured":"28) Riegerova J, Gaba A, Valenta M, et al. Ratio changes of selected components of body composition after lymphatic massage. Acta Univ Palacki Olomuc Gymn 2009; <b>39<\/b>: 7-14."}],"container-title":["Annals of Vascular Diseases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/avd\/15\/2\/15_oa.22-00037\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,25]],"date-time":"2022-06-25T05:12:55Z","timestamp":1656133975000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/avd\/15\/2\/15_oa.22-00037\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,25]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.3400\/avd.oa.22-00037","relation":{},"ISSN":["1881-641X","1881-6428"],"issn-type":[{"value":"1881-641X","type":"print"},{"value":"1881-6428","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,25]]},"article-number":"oa.22-00037"}}