{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T03:44:18Z","timestamp":1769571858786,"version":"3.49.0"},"reference-count":40,"publisher":"Georg Thieme Verlag KG","issue":"06","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nuklearmedizin"],"published-print":{"date-parts":[[2014]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p>Aim of this work is to report first experiences of the feasibility and applicability of a hybrid freehandSPECT\/ultrasound (fh-SPECT\/US) imaging concept, with regard to SLN imaging, in patients with breast cancer and malignant melanoma. Patients, methods: 18 patients with breast cancer or malignant melanoma received standard SLN scintigraphy. Following this, fh-SPECT using declipse\u00aeSPECT (SurgicEye, Munich, Germany) was performed, a handheld-gamma camera-based method to visualize activity distribution within a region of interest as a cross-sectional data set. These data were transferred to an ultrasound device and sensor-navigated ultrasound was performed combining fhSPECT data with ultrasound images, displaying superimposed images. Quality of fh- SPECT and co-registration accuracy was assigned to one of four categories and occurrence of artefacts was assessed. Results: In 4\/18 examinations, there was a no deviation regarding co-registration of both data sets. For 9\/18 patients, there was a deviation of &lt;1 cm (mean 0.7\u00b10.3 cm, range 0.3\u20131.0 cm). For 3\/18 patients, a deviation &gt;1 cm was present (mean 1.7\u00b10.3 cm, range 1.5\u20132.0 cm). In 2\/18 examinations no lymph node was found in the region of highest activity. Fh-SPECT reconstruction artifacts occurred in 6\/18 examinations. Conclusion: The fusion imaging concept combining SLN information with ultrasound images presented here proves to be feasible and technically successful. However, significant technical limitations were shown in fh-SPECT quality and fusion precision. Subject to technical optimisation of SPECT quality and co-registration, a meaningful contribution to the preoperative planning of lymph node therapy is imaginable. Thus, fundamentally a preoperative histological examination by fh-SPECT\/US-guided biopsy is possible.<\/jats:p>","DOI":"10.3413\/nukmed-0680-14-06","type":"journal-article","created":{"date-parts":[[2014,7,24]],"date-time":"2014-07-24T11:24:15Z","timestamp":1406201055000},"page":"259-264","source":"Crossref","is-referenced-by-count":31,"title":["Real-time ultrasound and freehand-SPECT"],"prefix":"10.3413","volume":"53","author":[{"given":"T.","family":"Winkens","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Opfermann","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Elsner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I.","family":"Runnebaum","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Darr","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Freesmeyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2018,1,4]]},"reference":[{"key":"10.3413\/Nukmed-0680-14-06-1","doi-asserted-by":"crossref","unstructured":"Abe H, Schmidt RA, Sennett CA et al. US-guided core needle biopsy of axillary lymph nodes in patients with breast cancer: why and how to do it. Radiographics 2007; 27 Suppl 1: S91-99","DOI":"10.1148\/rg.27si075502"},{"key":"10.3413\/Nukmed-0680-14-06-2","doi-asserted-by":"crossref","unstructured":"Bisplinghoff S, H\u00e4nisch C, Becker M et al. Fusion of coronary angiography and stress echocardiography for myocardial viability evaluation. Int J Comput Assist Radiol Surg 2014; DOI 10.1007\/s11548-014-1063-3","DOI":"10.1007\/s11548-014-1063-3"},{"key":"10.3413\/Nukmed-0680-14-06-3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejso.2013.02.008"},{"key":"10.3413\/Nukmed-0680-14-06-4","doi-asserted-by":"crossref","unstructured":"Bucki M, Chassat F, Galdames F et al. Real-Time SPECT and 2D Ultrasound Image Registration. In: Ayache N, Ourselin S, Maeder A (eds). Medical Image Computing and Computer-Assisted Intervention - MICCAI 2007. Vol 4792: Springer Berlin \/ Heidelberg 2007: 219-226","DOI":"10.1007\/978-3-540-75759-7_27"},{"key":"10.3413\/Nukmed-0680-14-06-5","doi-asserted-by":"publisher","DOI":"10.1097\/MNM.0b013e32832ed3a6"},{"key":"10.3413\/Nukmed-0680-14-06-6","doi-asserted-by":"publisher","DOI":"10.1007\/s00268-011-1319-9"},{"key":"10.3413\/Nukmed-0680-14-06-7","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2007.903572"},{"key":"10.3413\/Nukmed-0680-14-06-8","doi-asserted-by":"publisher","DOI":"10.3413\/nukmed-0320-10-05"},{"key":"10.3413\/Nukmed-0680-14-06-9","doi-asserted-by":"crossref","first-page":"N29","DOI":"10.1055\/s-0037-1622115","volume":"52","author":"Drescher","year":"2013","journal-title":"Nuklearmedizin"},{"key":"10.3413\/Nukmed-0680-14-06-10","doi-asserted-by":"publisher","DOI":"10.1093\/annonc\/mds229"},{"key":"10.3413\/Nukmed-0680-14-06-11","first-page":"B4172","volume":"57","author":"Ewertsen","year":"2010","journal-title":"Dan Med Bull"},{"key":"10.3413\/Nukmed-0680-14-06-12","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.14132415"},{"key":"10.3413\/Nukmed-0680-14-06-13","doi-asserted-by":"publisher","DOI":"10.1016\/j.ygyno.2013.04.023"},{"key":"10.3413\/Nukmed-0680-14-06-14","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-009-1157-2"},{"key":"10.3413\/Nukmed-0680-14-06-15","first-page":"244","volume":"111","author":"Janni","year":"2014","journal-title":"Dtsch Arztebl International"},{"key":"10.3413\/Nukmed-0680-14-06-16","doi-asserted-by":"publisher","DOI":"10.1007\/s00432-007-0333-7"},{"key":"10.3413\/Nukmed-0680-14-06-17","doi-asserted-by":"publisher","DOI":"10.3413\/nukmed-2012030001"},{"key":"10.3413\/Nukmed-0680-14-06-18","doi-asserted-by":"publisher","DOI":"10.1097\/MNM.0b013e3283508577"},{"key":"10.3413\/Nukmed-0680-14-06-19","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.12.9032"},{"key":"10.3413\/Nukmed-0680-14-06-20","doi-asserted-by":"publisher","DOI":"10.1016\/j.clindermatol.2012.08.015"},{"key":"10.3413\/Nukmed-0680-14-06-21","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2013.54.1177"},{"key":"10.3413\/Nukmed-0680-14-06-22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ygyno.2010.08.001"},{"key":"10.3413\/Nukmed-0680-14-06-23","doi-asserted-by":"publisher","DOI":"10.1109\/MC.2012.75"},{"key":"10.3413\/Nukmed-0680-14-06-24","doi-asserted-by":"publisher","DOI":"10.1007\/s12149-013-0758-9"},{"key":"10.3413\/Nukmed-0680-14-06-25","doi-asserted-by":"publisher","DOI":"10.1067\/j.cpradiol.2011.08.002"},{"key":"10.3413\/Nukmed-0680-14-06-26","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-009-0421-9"},{"key":"10.3413\/Nukmed-0680-14-06-27","doi-asserted-by":"crossref","first-page":"67","DOI":"10.3233\/CH-2011-1458","volume":"49","author":"Rennert","year":"2011","journal-title":"Clin Hemorheol Microcirc"},{"key":"10.3413\/Nukmed-0680-14-06-28","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.10.4865"},{"key":"10.3413\/Nukmed-0680-14-06-29","doi-asserted-by":"publisher","DOI":"10.1186\/2193-1801-2-350"},{"key":"10.3413\/Nukmed-0680-14-06-30","first-page":"2603","volume":"2007","author":"Tang","year":"2007","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"10.3413\/Nukmed-0680-14-06-31","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.112.113746"},{"key":"10.3413\/Nukmed-0680-14-06-32","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1002\/jso.21439","volume":"101","author":"Vermeeren","year":"2010","journal-title":"J Surg Oncol"},{"key":"10.3413\/Nukmed-0680-14-06-33","doi-asserted-by":"publisher","DOI":"10.3413\/nukmed-321"},{"key":"10.3413\/Nukmed-0680-14-06-34","doi-asserted-by":"publisher","DOI":"10.1097\/MNM.0b013e32835c5a24"},{"key":"10.3413\/Nukmed-0680-14-06-35","doi-asserted-by":"crossref","unstructured":"Wei S, Bleiweiss IJ, Nagi C et al. Characteristics of breast carcinoma cases with false-negative sentinel lymph nodes. Clin Breast Cancer 2014;","DOI":"10.1016\/j.clbc.2013.12.009"},{"key":"10.3413\/Nukmed-0680-14-06-36","doi-asserted-by":"publisher","DOI":"10.3413\/Nukmed-0535-12-10"},{"key":"10.3413\/Nukmed-0680-14-06-37","first-page":"909","volume":"10","author":"Wendler","year":"2007","journal-title":"Med Image Comput Comput Assist Interv"},{"key":"10.3413\/Nukmed-0680-14-06-38","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-010-1430-4"},{"key":"10.3413\/Nukmed-0680-14-06-39","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejso.2014.02.228"},{"key":"10.3413\/Nukmed-0680-14-06-40","doi-asserted-by":"publisher","DOI":"10.1111\/j.1524-4741.2009.00829.x"}],"container-title":["Nuklearmedizin"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.3413\/Nukmed-0680-14-06.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,8,22]],"date-time":"2020-08-22T14:52:38Z","timestamp":1598107958000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.3413\/Nukmed-0680-14-06"}},"subtitle":["Experiences with sentinel lymph node mapping"],"short-title":[],"issued":{"date-parts":[[2014]]},"references-count":40,"journal-issue":{"issue":"06","published-online":{"date-parts":[[2018,1,4]]},"published-print":{"date-parts":[[2014]]}},"URL":"https:\/\/doi.org\/10.3413\/nukmed-0680-14-06","relation":{},"ISSN":["0029-5566","2567-6407"],"issn-type":[{"value":"0029-5566","type":"print"},{"value":"2567-6407","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014]]}}}