{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,10]],"date-time":"2026-01-10T01:47:01Z","timestamp":1768009621822,"version":"3.49.0"},"reference-count":35,"publisher":"Georg Thieme Verlag KG","issue":"06","funder":[{"name":"Department of Companion Animal Clinical Studies Research Fund"},{"name":"Faculty of Veterinary Science"},{"DOI":"10.13039\/501100001343","name":"University of Pretoria","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001343","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Comp Orthop Traumatol"],"published-print":{"date-parts":[[2013]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p>Objectives: To describe a new technique, the reinforced interdental crossover composite splint (RIC), for transverse mandibular fracture repair in dogs. This technique was compared biomechanically with the established reinforced interdental Stout loop composite splint (RIS) technique.<\/jats:p><jats:p>Methods: Six pairs of mandibles from young adult small breed dogs were used for the study. Osteotomies were created in a standardized fashion and fixed with either RIC or RIS. All composite splint constructs were tested biomechanically with a cantilever bending force, using a single column testing machine at a rate of 2 mm\/min. The time of application, amount of composite used, ultimate force, stiffness, total displacement, and total energy absorbed during displacement of the rostral mandibular segment were calculated and compared between the two groups.<\/jats:p><jats:p>Results: No significant difference was found when comparing the time of application of the RIC and the RIS techniques. All implants failed by either composite resin fracture over the region of the osteotomy or by fracture between the first and second molar followed by detachment of the resin from the lingual enamel surface of the first molar. Differences between the RIC and RIS in force (80.5 N \u00b1 40.3 and 51.8 N \u00b1 27.4. respectively) and stiffness (16.2 N\/mm \u00b1 4.4 and 10.1 N\/mm \u00b1 4.1 respectively) were significant (p = 0.03). However differences between the two techniques in displacement and total energy absorbed were not significant.<\/jats:p><jats:p>Clinical significance: In experimentally fractured mandibles of young adult dogs there is evidence that RIC is biomechanically similar to RIS.<\/jats:p>","DOI":"10.3415\/vcot-12-11-0140","type":"journal-article","created":{"date-parts":[[2013,10,1]],"date-time":"2013-10-01T10:02:30Z","timestamp":1380621750000},"page":"461-468","source":"Crossref","is-referenced-by-count":8,"title":["The comparative biomechanics of the reinforced interdental crossover and the Stout loop composite splints for mandibular fracture repair in dogs"],"prefix":"10.3415","volume":"26","author":[{"given":"A. M.","family":"Kitshoff","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"de Rooster","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. M.","family":"Ferreira","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Burger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Steenkamp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2018,1,4]]},"reference":[{"key":"10.3415\/VCOT-12-11-0140-1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-5827.1979.tb06679.x"},{"key":"10.3415\/VCOT-12-11-0140-2","doi-asserted-by":"publisher","DOI":"10.1136\/vr.115.11.273"},{"key":"10.3415\/VCOT-12-11-0140-3","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1177\/089875640502200202","volume":"22","author":"Lopes","year":"2005","journal-title":"J Vet Dent"},{"key":"10.3415\/VCOT-12-11-0140-4","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-12-01-0003"},{"key":"10.3415\/VCOT-12-11-0140-5","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1990.tb01184.x"},{"key":"10.3415\/VCOT-12-11-0140-6","doi-asserted-by":"crossref","unstructured":"Smith M, Legendre L. Maxillofacial fracture repair using noninvasive techniques. In: Verstraete FJM, Lommer MJ, Bezuidenhout AJ, editors. Oral and Maxillofacial Surgery in Dogs and Cats. Edinburgh: Saunders\/Elsevier; 2012. p. 275-284","DOI":"10.1016\/B978-0-7020-4618-6.00029-4"},{"key":"10.3415\/VCOT-12-11-0140-7","unstructured":"Verstraete FJM. Maxillofacial fractures. In: Slatter DH, editor. Textbook of Small Animal Surgery. Volume - 2. 3rd ed. Philadelphia: Saunders; 2003. p. 2190-2207"},{"key":"10.3415\/VCOT-12-11-0140-8","doi-asserted-by":"crossref","unstructured":"Verstraete FJM. Maxillofacial fractures. In: Holmstrom SE, Frost P, Eisner ER, editors. Veterinary Dental Techniques for the Small Animal Practitioner. 3rd ed. Philadelphia: W.B. Saunders; 2004. p. 559-600","DOI":"10.1016\/B0-72-169383-0\/50013-6"},{"key":"10.3415\/VCOT-12-11-0140-9","unstructured":"Scott H. The skull and mandible. In: Coughlan AR, Miller A, editors. BSAVA Manual of Small Animal\u00a0Fracture\u00a0Repair and Management. Cheltenham: British Small Animal Veterinary Association; 1998. p. 115-129"},{"key":"10.3415\/VCOT-12-11-0140-10","doi-asserted-by":"publisher","DOI":"10.1136\/inpract.25.10.570"},{"key":"10.3415\/VCOT-12-11-0140-11","unstructured":"Evans HE. The skeleton. In: Miller ME, Evans HE, editors. Miller's Anatomy of the Dog. 3rd ed. Philadelphia: Saunders; 1993. p. 122-218"},{"key":"10.3415\/VCOT-12-11-0140-12","unstructured":"Evans H. The heart and arteries. In: Miller ME, Evans HE, editors. Miller's Anatomy of the Dog. 3rd ed. Philadelphia: Saunders; 1993. p. 586-681"},{"key":"10.3415\/VCOT-12-11-0140-13","doi-asserted-by":"crossref","unstructured":"Manfra Marretta S. Maxillofacial fracture complications. In: Verstraete FJM, Lommer MJ, Bezuidenhout AJ, editors. Oral and Maxillofacial Surgery in Dogs and Cats. Edinburgh: Saunders\/Elsevier; 2012. p. 333-341","DOI":"10.1016\/B978-0-7020-4618-6.00034-8"},{"key":"10.3415\/VCOT-12-11-0140-14","doi-asserted-by":"crossref","first-page":"258","DOI":"10.2460\/ajvr.1992.53.02.258","volume":"53","author":"Smith","year":"1992","journal-title":"Am J Vet Res"},{"key":"10.3415\/VCOT-12-11-0140-15","unstructured":"Weigel JP. Trauma to oral structures. In: Harvey CE, editor. Veterinary Dentistry. Philadelphia: WB Saunders 1987; 140-155"},{"key":"10.3415\/VCOT-12-11-0140-16","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.2460\/ajvr.1993.54.07.1177","volume":"54","author":"Kern","year":"1993","journal-title":"Am J Vet Res"},{"key":"10.3415\/VCOT-12-11-0140-17","doi-asserted-by":"crossref","first-page":"873","DOI":"10.2460\/ajvr.1988.49.06.873","volume":"49","author":"Roe","year":"1988","journal-title":"Am J Vet Res"},{"key":"10.3415\/VCOT-12-11-0140-18","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2010.00782.x"},{"key":"10.3415\/VCOT-12-11-0140-19","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.2001.62.576"},{"key":"10.3415\/VCOT-12-11-0140-20","doi-asserted-by":"publisher","DOI":"10.1007\/BF01062525"},{"key":"10.3415\/VCOT-12-11-0140-21","doi-asserted-by":"publisher","DOI":"10.1177\/0049124104268644"},{"key":"10.3415\/VCOT-12-11-0140-22","first-page":"36","volume":"4","author":"Norsworthy","year":"1977","journal-title":"Canine Pract"},{"key":"10.3415\/VCOT-12-11-0140-23","unstructured":"Boudrieau RJ. Mandibular and maxillofacial fractures. In: Tobias KM, Johnston SA, editors. Veterinary Surgery: Small Animal. 1. 1st ed. St. Louis, Missouri: Elsevier, Suanders; 2012. p.1054-1077"},{"key":"10.3415\/VCOT-12-11-0140-24","first-page":"220","volume":"2","author":"Manfra","year":"1990","journal-title":"Probl Vet Med"},{"key":"10.3415\/VCOT-12-11-0140-25","unstructured":"Craig RG, Powers J. Bonding to dental materials. In: Craig RG, Powers J, editors. Restorative dental materials. 11th ed. St Louis: Mosby; 2002. p. 264-266"},{"key":"10.3415\/VCOT-12-11-0140-26","unstructured":"ESPE Dental Products. Protemp 4 Temporization Material Technical Data Sheet [document on the internet]. Seefeld, Germany: 3M ESPE AG; 2008 [cited 2012 November 7]. Available from: http:\/\/multimedia.3m.com\/mws\/mediawebserver?mwsId=66666UF6EVsSyXTtNXfXoxTEEVtQEVs6EVs6EVs6E666666--&fn=protemp_4_tds_ebu.pdf"},{"key":"10.3415\/VCOT-12-11-0140-27","first-page":"36","volume":"67","author":"Lieu","year":"2001","journal-title":"J Can Dent Assoc"},{"key":"10.3415\/VCOT-12-11-0140-28","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1177\/089875640302000201","volume":"20","author":"Legendre","year":"2003","journal-title":"J Vet Dent"},{"key":"10.3415\/VCOT-12-11-0140-29","first-page":"1","volume":"3","author":"Kurtzman","year":"2006","journal-title":"Dental Economics"},{"key":"10.3415\/VCOT-12-11-0140-30","doi-asserted-by":"crossref","unstructured":"Keller T, Liebschner M. Tensile and Compression Testing of Bone. In: An Y, Draughn R, editors. Mechanical Testing of Bone and the Bone-Implant Interface. New York, Washington, USA: CRC Press; 1999. p. 175-205","DOI":"10.1201\/9781420073560.sec2"},{"key":"10.3415\/VCOT-12-11-0140-31","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(03)00259-2"},{"key":"10.3415\/VCOT-12-11-0140-32","doi-asserted-by":"publisher","DOI":"10.1016\/S0109-5641(00)00098-1"},{"key":"10.3415\/VCOT-12-11-0140-33","doi-asserted-by":"crossref","unstructured":"An Y. Mechanical Properties of Bone. In: An Y, Draughn R, editors. Mechanical Testing of Bone and the Bone-Implant Interface. Danvers, USA: CRC Press; 1999. p. 41-63","DOI":"10.1201\/9781420073560.ch3"},{"key":"10.3415\/VCOT-12-11-0140-34","unstructured":"Cross AR. Fracture biology and biomechanics. In: Tobias KM, Johnston SA, editors. Veterinary Surgery: Small Animal. Volume 1. St. Louis, Missouri: Elsevier Saunders; 2011. p. 565-571"},{"key":"10.3415\/VCOT-12-11-0140-35","doi-asserted-by":"crossref","unstructured":"Lopez MJ, Markel MD. Bending tests of bone. In: An Y, Draughn R, editors. Mechanical Testing of Bone and the Bone-Implant Interface. New York, Washington, USA: CRC Press; 1999. p. 207-217","DOI":"10.1201\/9781420073560.ch12"}],"container-title":["Veterinary and Comparative Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.3415\/VCOT-12-11-0140.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T15:06:22Z","timestamp":1746025582000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.3415\/VCOT-12-11-0140"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"references-count":35,"journal-issue":{"issue":"06","published-online":{"date-parts":[[2018,1,4]]},"published-print":{"date-parts":[[2013]]}},"URL":"https:\/\/doi.org\/10.3415\/vcot-12-11-0140","relation":{},"ISSN":["0932-0814","2567-6911"],"issn-type":[{"value":"0932-0814","type":"print"},{"value":"2567-6911","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013]]}}}