{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T11:34:44Z","timestamp":1770982484892,"version":"3.50.1"},"reference-count":27,"publisher":"Georg Thieme Verlag KG","issue":"05","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Comp Orthop Traumatol"],"published-print":{"date-parts":[[2014]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p>A four-year old male Labrador Retriever was admitted with head trauma after being hit by a car. The dog had sustained multiple nasal, maxillary, and frontal bone fractures that resulted in separation of the maxilla from the base of the skull. A severely comminuted left zygomatic arch fracture was also present. These fractures were all repaired using a point contact, locking titanium plate system, in a single procedure that resulted in excellent postoperative occlusion and immediate function. Healing was uneventful. Full function and excellent cosmetic appearance were evident 13 months after surgery. This case illustrates the ease of repair and the success of treatment of severely comminuted maxillofacial fractures by conforming to basic biomechanical principles taken directly from the human experience and successfully applied to the dog; these included multiple plate application along the buttresses and trusses of the facial skeleton. The plate fixation was applied to bridge the multiple fractures along the most appropriate lines of stress. The small size of the plates, and the ability to easily contour them to adapt to the bone surface in threedimensions, allowed their placement in the most appropriate positions to achieve sufficient rigidity and lead to uncomplicated healing without any postoperative complications.<\/jats:p>","DOI":"10.3415\/vcot-14-03-0044","type":"journal-article","created":{"date-parts":[[2014,8,4]],"date-time":"2014-08-04T08:26:37Z","timestamp":1407140797000},"page":"398-404","source":"Crossref","is-referenced-by-count":7,"title":["Surgical repair of a severely comminuted maxillary fracture in a dog with a titanium locking plate system"],"prefix":"10.3415","volume":"27","author":[{"given":"E.","family":"Illukka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R. J.","family":"Boudrieau","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2017,12,22]]},"reference":[{"key":"10.3415\/VCOT-14-03-0044-1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1996.tb01414.x"},{"key":"10.3415\/VCOT-14-03-0044-2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950x.2004.04023.x"},{"key":"10.3415\/VCOT-14-03-0044-3","doi-asserted-by":"crossref","unstructured":"Arzi B, Verstraete FJM. Internal fixation of severe maxillofacial fractures in dogs. Vet Surg 2014 Feb 11; [Epub ahead of print]","DOI":"10.1111\/j.1532-950X.2014.12161.x"},{"key":"10.3415\/VCOT-14-03-0044-4","unstructured":"Gerlach KL, Pape H-D. Midface fractures. In: H\u00e4rle F, Champy M, Terry BC, editors. Atlas of Craniomaxillofacial Osteosynthesis: Miniplates, Microplates, and Screws. Stuttgart: Thieme; 1999. pg. 76-80"},{"key":"10.3415\/VCOT-14-03-0044-5","unstructured":"Bos RRM. Panfacial fractures: Planning an organized treatment. In: H\u00e4rle F, Champy M, Terry BC, editors. Atlas of Craniomaxillofacial Osteosynthesis: Miniplates, Microplates, and Screws. Stuttgart: Thieme; 1999. pg. 85-89"},{"key":"10.3415\/VCOT-14-03-0044-6","unstructured":"Gruss JS, Phillips JH. Rigid fixation of LeFort maxillary fractures. In: Gruss JS, Manson PN, Yaremchuk MJ, editors. Rigid Fixation of the Craniomaxillofacial Skeleton. Boston: Butterworth-Heinemann; 1992. pg. 245-262"},{"key":"10.3415\/VCOT-14-03-0044-7","doi-asserted-by":"crossref","unstructured":"Manson PN. Organization and treatment in panfacial fractures. In: Prein J, editor. Manual of Internal Fixation in the Cranio-Facial Skeleton. Berlin: Springer; 1998. pg. 95-107","DOI":"10.1007\/978-3-642-58789-4_4"},{"key":"10.3415\/VCOT-14-03-0044-8","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199004000-00002"},{"key":"10.3415\/VCOT-14-03-0044-9","unstructured":"Forrest CR, Phillips JH, Prein J. LeFort I-III fractures. In: Prein J, editor. Manual of Internal Fixation in the Cranio-Facial Skeleton. Berlin: Springer; 1998. pg. 108-126"},{"key":"10.3415\/VCOT-14-03-0044-10","unstructured":"Boudrieau RJ. Mandibular and maxillofacial fractures. In: Tobias K, Johnston S, editors. Veterinary Surgery - Small Animal. St. Louis: Elsevier; 2012. pg. 1054-1077"},{"key":"10.3415\/VCOT-14-03-0044-11","doi-asserted-by":"crossref","unstructured":"Boudrieau RJ. Maxillofacial fracture repair using miniplates and screws. In: Verstraete FJM, Lommer MJ, editors. Oral and Maxillofacial Surgery in Dogs and Cats. Edinburgh: Elsevier; 2012. pg. 293-308","DOI":"10.1016\/B978-0-7020-4618-6.00031-2"},{"key":"10.3415\/VCOT-14-03-0044-12","doi-asserted-by":"crossref","unstructured":"Boudrieau RJ, Verstraete FJ. Principles of maxillofacial trauma repair. In: Verstraete FJM, Lommer MJ, editors. Oral and Maxillofacial Surgery in Dogs and Cats. Edinburgh: Elsevier; 2012. pg. 233-242","DOI":"10.1016\/B978-0-7020-4618-6.00025-7"},{"key":"10.3415\/VCOT-14-03-0044-13","unstructured":"Boudrieau RJ. The Advanced Locking Plate System (ALPS): Design rationale, biomechanics and early clinical use. Proceedings of the 2009 ACVS Veterinary Symposium. 2009 October 8-10; Washington DC, USA. pg. 482-486"},{"key":"10.3415\/VCOT-14-03-0044-14","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2014.12097.x"},{"key":"10.3415\/VCOT-14-03-0044-15","unstructured":"Reddy LV, Pagnatto M. Midface fractures. In: Fonseca RJ, Turvey TA, Marciani RD, editors. Oral and Maxillofacial Surgery. Volume II, 2nd ed. St. Louis: Saunders; 2009. pg. 239-255"},{"key":"10.3415\/VCOT-14-03-0044-16","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1177\/089875640502200401","volume":"22","author":"Reiter","year":"2005","journal-title":"J Vet Dent"},{"key":"10.3415\/VCOT-14-03-0044-17","first-page":"21","volume":"7","author":"Henney","year":"1992","journal-title":"Semin Vet Med Surg (Small Anim)"},{"key":"10.3415\/VCOT-14-03-0044-18","unstructured":"Abubaker AO, Papadopolous H, Giglio JA. Diagnosis and management of dentoalveolar injuries. In: Fonseca RJ, Turvey TA, Marciani RD, editors. Oral and Maxillofacial Surgery. Vol II, 2nd ed. St Louis: Saunders; 2009. pg. 104-138"},{"key":"10.3415\/VCOT-14-03-0044-19","first-page":"6671","volume":"23","author":"Flores","year":"2007","journal-title":"Dent Traumatol"},{"key":"10.3415\/VCOT-14-03-0044-20","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-0813.2003.tb12533.x"},{"key":"10.3415\/VCOT-14-03-0044-21","doi-asserted-by":"crossref","unstructured":"Arens S, Schlegel U, Printzen C, et al. Influence of materials for fixation implants on local infection: An experimental study of steel versus titanium in rabbits. J Bone Joint Surg [Br] 1996; 78B: 647-651","DOI":"10.1302\/0301-620X.78B4.0780647"},{"key":"10.3415\/VCOT-14-03-0044-22","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199909000-00002"},{"key":"10.3415\/VCOT-14-03-0044-23","doi-asserted-by":"crossref","unstructured":"Perren SM, Buchanan JS. Basic concepts relevant to the design and development of the Point Contact Fixator (PC-Fix). Injury 29 (Suppl 2) 1995; S-B1-4","DOI":"10.1016\/0020-1383(95)96891-7"},{"key":"10.3415\/VCOT-14-03-0044-24","doi-asserted-by":"crossref","unstructured":"Tepic S, Perren SM. The biomechanics of the PC-fix internal fixator. Injury 29 (Suppl 2) 1995; S-B5-10","DOI":"10.1016\/0020-1383(95)96892-8"},{"key":"10.3415\/VCOT-14-03-0044-25","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199701000-00005"},{"key":"10.3415\/VCOT-14-03-0044-26","doi-asserted-by":"crossref","unstructured":"Eijer H, Hauke C, Arens S, et al. PC-Fix and local infection resistance--influence of implant design on postoperative infection development, clinical and experimental results. Injury 32 (Suppl 2) 2001; B38-43","DOI":"10.1016\/S0020-1383(01)00124-3"},{"key":"10.3415\/VCOT-14-03-0044-27","doi-asserted-by":"crossref","unstructured":"Schlegel U, Perren SM. Surgical aspects of infection involving osteosynthesis implants: implant design and resistance to local infection. Injury 37 (Suppl 2) 2006; S67-73.","DOI":"10.1016\/j.injury.2006.04.011"}],"container-title":["Veterinary and Comparative Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.3415\/VCOT-14-03-0044.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,13]],"date-time":"2019-08-13T10:38:43Z","timestamp":1565692723000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.3415\/VCOT-14-03-0044"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014]]},"references-count":27,"journal-issue":{"issue":"05","published-online":{"date-parts":[[2017,12,22]]},"published-print":{"date-parts":[[2014]]}},"URL":"https:\/\/doi.org\/10.3415\/vcot-14-03-0044","relation":{},"ISSN":["0932-0814","2567-6911"],"issn-type":[{"value":"0932-0814","type":"print"},{"value":"2567-6911","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014]]}}}