{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T13:35:39Z","timestamp":1777988139301,"version":"3.51.4"},"reference-count":45,"publisher":"Sociedade Brasileira de Cardiologia","issue":"2","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arq. Bras. Cardiol."],"abstract":"<jats:p>Resumo  Fundamento  A interven\u00e7\u00e3o coron\u00e1ria percut\u00e2nea (ICP) de vasos de muito pequeno calibre (\u2264 2,25mm) \u00e9 um desafio t\u00e9cnico e tem piores resultados quando comparado aos maiores calibres. O stent Inspiron\u00ae \u00e9 um stent farmacol\u00f3gico (SF) feito no Brasil, o qual t\u00eam seguran\u00e7a e efic\u00e1cia avaliadas por diversos estudos em diferentes cen\u00e1rios, mas n\u00e3o h\u00e1 dados analisando seu desempenho em vasos &lt;2,5mm.  Objetivos  Analisar os resultados cl\u00ednicos de ICP com SF\u2019s em vasos de muito pequeno calibre e comparar com outras plataformas de SF\u2019s contempor\u00e2neos. O desfecho MACE foi definido como por mortalidade card\u00edaca, infarto da les\u00e3o alvo e revasculariza\u00e7\u00e3o de les\u00e3o alvo clinicamente dirigida.  M\u00e9todos  Estudo observacional, com amostra consecutiva em centro de refer\u00eancia no Brasil, entre 2017 e 2021, tendo desfechos analisados nos per\u00edodos intra-hospitalar, 30 dias, seis e 12 meses, com n\u00edvel de signific\u00e2ncia estat\u00edstica de 5%.  Resultados  Um total de 783 SF\u2019s foram implantados, sendo 47% INSPIRON\u00ae e 46,8% \u201cOutros SF\u2019s\u201d. A idade m\u00e9dia dos pacientes foi de 64,7\u00b111 anos, 61% dos pacientes masculinos e 42% portadores de Diabetes Mellitus. Aos 12 meses, o desfecho de MACE geral foi 4,54% (36\/793) e foi similar entre os grupos comparados (Inspiron\u00ae-4,6%; vs.. \u201cOutros SF\u2019s\u201d -4,6%; p=1,000), sem diferen\u00e7a significativa nos desfechos individuais. A taxa de trombose de stent foi similar entre os grupos (4 [1,0%] vs. 2 [0,5%], p 0,868).  Conclus\u00e3o  Nossos achados demonstram resultados aceit\u00e1veis e com desempenho similar em 12 meses do Inspiron\u00ae a outros SF\u2019s contempor\u00e2neos em vasos de muito pequeno calibre.<\/jats:p>","DOI":"10.36660\/abc.20250145","type":"journal-article","created":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T18:54:26Z","timestamp":1773687266000},"source":"Crossref","is-referenced-by-count":0,"title":["Registro de Interven\u00e7\u00f5es Coron\u00e1rias em Vasos de Muito Pequeno Calibre: An\u00e1lise de Stent Eluidor de Sirolimus e Outros Stents Contempor\u00e2neos"],"prefix":"10.36660","volume":"123","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4198-2621","authenticated-orcid":false,"given":"Jo\u00e3o Vitor","family":"Slaviero","sequence":"first","affiliation":[{"name":"Instituto de Cardiologia,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andr\u00e9 Luiz Langer","family":"Manica","sequence":"additional","affiliation":[{"name":"Instituto de Cardiologia,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9674-8528","authenticated-orcid":false,"given":"Rog\u00e9rio Eduardo Gomes Sarmento","family":"Leite","sequence":"additional","affiliation":[{"name":"Instituto de Cardiologia,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-3237-0199","authenticated-orcid":false,"given":"Eduarda Paiva","family":"Borsa","sequence":"additional","affiliation":[{"name":"Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2823-5365","authenticated-orcid":false,"given":"Marcia Moura","family":"Schmidt","sequence":"additional","affiliation":[{"name":"Instituto de Cardiologia,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-3986-4848","authenticated-orcid":false,"given":"Rodrigo Campos","family":"Ogando","sequence":"additional","affiliation":[{"name":"Pontif\u00edcia Universidade Cat\u00f3lica do Rio Grande do Sul,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julia Kurtz","family":"Teixeira","sequence":"additional","affiliation":[{"name":"Instituto de Cardiologia,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7883-828X","authenticated-orcid":false,"given":"Raphael Boesche","family":"Guimar\u00e3es","sequence":"additional","affiliation":[{"name":"Instituto de Cardiologia,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexandre Damiani","family":"Azmus","sequence":"additional","affiliation":[{"name":"Instituto de Cardiologia,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos A. M.","family":"Gottschall","sequence":"additional","affiliation":[{"name":"Instituto de Cardiologia,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"22636","published-online":{"date-parts":[[2026]]},"reference":[{"issue":"24","key":"ref1","doi-asserted-by":"crossref","first-page":"2840","DOI":"10.1016\/j.jcin.2020.08.035","article-title":"Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease: PICCOLETO II Randomized Clinical Trial","volume":"13","author":"Cortese B","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"issue":"4","key":"ref2","first-page":"E262","article-title":"Temporal Trends in Percutaneous Coronary Interventions thru the Drug Eluting Stent Era: Insights from 18,641 Procedures Performed Over 12-Year Period","volume":"92","author":"Landes U","year":"2018","journal-title":"Catheter Cardiovasc Interv"},{"issue":"2","key":"ref3","doi-asserted-by":"crossref","first-page":"e167","DOI":"10.4244\/EIJV12I2A30","article-title":"Bioresorbable Polymer Sirolimus-Eluting Coronary Stent Compared with Permanent Polymer Everolimus-Eluting Coronary Stent Implantation for Treatment of Small Vessel Coronary Artery Disease: CENTURY II Trial","volume":"12","author":"W\u00f6hrle J","year":"2016","journal-title":"EuroIntervention"},{"issue":"1","key":"ref4","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/S0735-1097(99)00181-3","article-title":"Implications of Small Reference Vessel Diameter in Patients Undergoing Percutaneous Coronary Revascularization","volume":"34","author":"Schunkert H","year":"1999","journal-title":"J Am Coll Cardiol"},{"issue":"5","key":"ref5","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1161\/01.CIR.74.5.964","article-title":"Histologic Evidence for Small-Vessel Coronary Artery Disease in Patients with Angina Pectoris and Patent Large Coronary Arteries","volume":"74","author":"Mosseri M","year":"1986","journal-title":"Circulation"},{"issue":"8","key":"ref6","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1016\/j.jacc.2004.11.063","article-title":"Relationship between Angiographic Late Loss and Target Lesion Revascularization after Coronary Stent Implantation: Analysis from the TAXUS-IV Trial","volume":"45","author":"Ellis SG","year":"2005","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"ref7","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.jjcc.2013.06.015","article-title":"Association of Prediabetes with Diffuse Coronary Narrowing and Small-Vessel Disease","volume":"63","author":"Ertan C","year":"2014","journal-title":"J Cardiol"},{"issue":"4","key":"ref8","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.carrev.2015.03.008","article-title":"Composite Outcomes in 2.25-mm Drug Eluting Stents: A Systematic Review","volume":"16","author":"Lee JZ","year":"2015","journal-title":"Cardiovasc Revasc Med"},{"issue":"1","key":"ref9","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1177\/0300060517717826","article-title":"One-Year Clinical Outcomes of Patients Implanted with a Resolute Onyx\u2122 Zotarolimus-Eluting Stent","volume":"46","author":"Tam CC","year":"2018","journal-title":"J Int Med Res"},{"issue":"5","key":"ref10","doi-asserted-by":"crossref","first-page":"767","DOI":"10.5603\/CJ.a2020.0127","article-title":"Small Vessel Coronary Artery Disease: How Small can we go with Myocardial Revascularization?","volume":"28","author":"Wybraniec MT","year":"2021","journal-title":"Cardiol J"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.ahj.2016.02.020","article-title":"Small-Vessel Treatment with Contemporary Newer-Generation Drug-Eluting Coronary Stents in All-Comers: Insights from 2-year DUTCH PEERS (TWENTE II) Randomized Trial","volume":"176","author":"van der Heijden LC","year":"2016","journal-title":"Am Heart J"},{"issue":"2","key":"ref12","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1136\/heartjnl-2013-304933","article-title":"Incidence and Predictors of Restenosis after Coronary Stenting in 10 004 Patients with Surveillance Angiography","volume":"100","author":"Cassese S","year":"2014","journal-title":"Heart"},{"issue":"11","key":"ref13","doi-asserted-by":"crossref","first-page":"1209","DOI":"10.1016\/j.jcin.2011.07.016","article-title":"Impact of Lesion Length and Vessel Size on Clinical Outcomes after Percutaneous Coronary Intervention with Everolimus- versus Paclitaxel-Eluting Stents Pooled Analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-Generation Everolimus-Eluting and Paclitaxel-Eluting Stents in Real-Life Practice) Randomized Trials","volume":"4","author":"Claessen BE","year":"2011","journal-title":"JACC Cardiovasc Interv"},{"issue":"4","key":"ref14","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1161\/01.CIR.93.4.652","article-title":"Effect of Coronary Artery Diameter in Patients Undergoing Coronary Bypass Surgery. Northern New England Cardiovascular Disease Study Group","volume":"93","author":"O'Connor NJ","year":"1996","journal-title":"Circulation"},{"issue":"2","key":"ref15","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000024063","article-title":"Coronary Artery Size as a Predictor of Y-Graft Patency Following Coronary Artery Bypass Surgery","volume":"100","author":"Limanto DH","year":"2021","journal-title":"Medicine"},{"issue":"6","key":"ref16","doi-asserted-by":"crossref","first-page":"1972","DOI":"10.1016\/S0022-5223(03)01276-5","article-title":"Factors affecting Saphenous Vein Graft Patency: Clinical and Angiographic Study in 1402 Symptomatic Patients Operated on Between 1977 and 1999","volume":"126","author":"Shah PJ","year":"2003","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"3","key":"ref17","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1016\/j.ijcard.2014.09.143","article-title":"Impact of Stent Strut Design in Metallic Stents and Biodegradable Scaffolds","volume":"177","author":"Foin N","year":"2014","journal-title":"Int J Cardiol"},{"issue":"3","key":"ref18","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/S0735-1097(02)01989-7","article-title":"In-Stent Restenosis in Small Coronary Arteries: Impact of Strut Thickness","volume":"40","author":"Briguori C","year":"2002","journal-title":"J Am Coll Cardiol"},{"issue":"13","key":"ref19","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.1161\/CIRCULATIONAHA.110.003210","article-title":"Stent Thrombogenicity Early in High-Risk Interventional Settings is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings","volume":"123","author":"Kolandaivelu K","year":"2011","journal-title":"Circulation"},{"issue":"9","key":"ref20","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1016\/j.jcin.2020.01.230","article-title":"Thin Composite-Wire-Strut Zotarolimus-Eluting Stents versus Ultrathin-Strut Sirolimus-Eluting Stents in BIONYX at 2 Years","volume":"13","author":"Buiten RA","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"issue":"4","key":"ref21","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.jacasi.2022.02.009","article-title":"Comparison of Different Types of Drug-Eluting Stents for De Novo Long Coronary Artery Lesions","volume":"2","author":"Kang DY","year":"2022","journal-title":"JACC Asia"},{"issue":"6","key":"ref22","doi-asserted-by":"crossref","first-page":"492","DOI":"10.4244\/EIJ-D-21-00766","article-title":"Sirolimus-Eluting Stents with Ultrathin Struts Versus Everolimus-Eluting Stents for Patients Undergoing Percutaneous Coronary Intervention: Final Three-Year Results of the TALENT Trial","volume":"18","author":"Winter RJ","year":"2022","journal-title":"EuroIntervention"},{"issue":"1","key":"ref23","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1007\/s12928-018-0511-3","article-title":"Two-Year Results after Coronary Stenting of Small Vessels in Japanese Population Using 2.25-mm Diameter Sirolimus-Eluting Stent with Bioresorbable Polymer: Primary and Long-Term Outcomes of CENTURY JSV Study","volume":"34","author":"Saito S","year":"2019","journal-title":"Cardiovasc Interv Ther"},{"issue":"10","key":"ref24","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.4244\/EIJV12I10A200","article-title":"Outcomes of Stenting Extra-Small (=2.25 mm) Vessels Using the Resolute Zotarolimus-Eluting Stent (R-ZES)","volume":"12","author":"Parikh MA","year":"2016","journal-title":"EuroIntervention"},{"issue":"2","key":"ref25","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1136\/heartjnl-2013-304933","article-title":"Incidence and Predictors of Restenosis after Coronary Stenting in 10 004 Patients with Surveillance Angiography","volume":"100","author":"Cassese S","year":"2014","journal-title":"Heart"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"915","DOI":"10.2147\/VHRM.S8161","article-title":"Small Coronary Vessel Angioplasty: Outcomes and Technical Considerations","volume":"6","author":"Rathore S","year":"2010","journal-title":"Vasc Health Risk Manag"},{"issue":"3","key":"ref27","first-page":"290","article-title":"Influence of Stent Design on 1-Year Outcome after Coronary Stent Placement: A Randomized Comparison of Five Stent Types in 1,147 Unselected Patients","volume":"50","author":"Kastrati A","year":"2000","journal-title":"Catheter Cardiovasc Interv"},{"issue":"4","key":"ref28","first-page":"264","article-title":"Four-Year Clinical Follow-Up of the First-In-Man Randomized Comparison of a Novel Sirolimus Eluting Stent with Abluminal Biodegradable Polymer and Ultra-Thin Strut Cobalt-Chromium Alloy: The INSPIRON-I Trial","volume":"5","author":"Oliveira MD","year":"2015","journal-title":"Cardiovasc Diagn Ther"},{"key":"ref29","doi-asserted-by":"crossref","DOI":"10.1155\/2020\/6340716","article-title":"One-Year Clinical Outcome of Inspiron Stent in All-Comers Population (Analysis from 790 Consecutive Patients)","volume":"2020","author":"Falc\u00e3o F","year":"2020","journal-title":"J Interv Cardiol"},{"issue":"6","key":"ref30","article-title":"Real-World Assessment of an Ultrathin Strut, Sirolimus-Eluting Stent in Patients with ST-Elevation Myocardial Infarction Submitted to Primary Percutaneous Coronary Intervention (INSTEMI Registry)","volume":"120","author":"Araujo GN","year":"2023","journal-title":"Arq Bras Cardiol"},{"issue":"18","key":"ref31","doi-asserted-by":"crossref","first-page":"2231","DOI":"10.1016\/j.jacc.2018.08.1038","article-title":"Fourth Universal Definition of Myocardial Infarction (2018)","volume":"72","author":"Thygesen K","year":"2018","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"ref32","doi-asserted-by":"crossref","first-page":"1","DOI":"10.5935\/abc.20170111","article-title":"Diretriz da Sociedade Brasileira de Cardiologia e da Sociedade Brasileira de Hemodin\u00e2mica e Cardiologia Intervencionista sobre Interven\u00e7\u00e3o Coron\u00e1ria Percut\u00e2nea","volume":"109","author":"Feres F","year":"2017","journal-title":"Arq Bras Cardiol"},{"issue":"17","key":"ref33","doi-asserted-by":"crossref","first-page":"2126","DOI":"10.1001\/jama.293.17.2126","article-title":"Incidence, Predictors, and Outcome of Thrombosis after Successful Implantation of Drug-Eluting Stents","volume":"293","author":"Iakovou I","year":"2005","journal-title":"JAMA"},{"issue":"7","key":"ref34","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1161\/01.CIR.0000116750.63158.94","article-title":"Clinical and Angiographic Predictors of Restenosis after Stent Deployment in Diabetic Patients","volume":"109","author":"West NE","year":"2004","journal-title":"Circulation"},{"issue":"1","key":"ref35","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1161\/01.CIR.57.1.133","article-title":"Diffuse Coronary Artery Disease in Diabetic Patients: Fact or Fiction?","volume":"57","author":"Dortimer AC","year":"1978","journal-title":"Circulation"},{"issue":"24","key":"ref36","doi-asserted-by":"crossref","first-page":"2868","DOI":"10.1016\/j.jcin.2020.09.014","article-title":"Target Lesion Failure with Current Drug-Eluting Stents: Evidence from a Comprehensive Network Meta-Analysis","volume":"13","author":"Taglieri N","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"issue":"20","key":"ref37","doi-asserted-by":"crossref","first-page":"2216","DOI":"10.1161\/CIRCULATIONAHA.118.034456","article-title":"Newer-Generation Ultrathin Strut Drug-Eluting Stents versus Older Second-Generation Thicker Strut Drug-Eluting Stents for Coronary Artery Disease","volume":"138","author":"Bangalore S","year":"2018","journal-title":"Circulation"},{"issue":"2","key":"ref38","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.ahj.2012.08.007","article-title":"Safety and Efficacy of Everolimus- versus Sirolimus-Eluting Stents: A Systematic Review and Meta-Analysis of 11 Randomized Trials","volume":"165","author":"Park KW","year":"2013","journal-title":"Am Heart J"},{"issue":"4","key":"ref39","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1161\/CIRCINTERVENTIONS.111.963256","article-title":"Everolimus-Eluting versus Sirolimus-Eluting Stents: A Meta-Analysis of Randomized Trials","volume":"4","author":"Waha A","year":"2011","journal-title":"Circ Cardiovasc Interv"},{"issue":"2","key":"ref40","first-page":"68","article-title":"Clinical Utility of Intravascular Ultrasonography-Guided Therapy in a Small-Vessel Coronary Lesion Associated with Type 2 Diabetes Mellitus","volume":"22","author":"Li L","year":"2019","journal-title":"Anatol J Cardiol"},{"issue":"1","key":"ref41","first-page":"E9","article-title":"Optimal Threshold of Postintervention Minimum Stent Area to Predict In-Stent Restenosis in Small Coronary Arteries: An Optical Coherence Tomography Analysis","volume":"87","author":"Matsuo Y","year":"2016","journal-title":"Catheter Cardiovasc Interv"},{"issue":"4","key":"ref42","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.116.003700","article-title":"Outcomes with Intravascular Ultrasound-Guided Stent Implantation: A Meta-Analysis of Randomized Trials in the Era of Drug-Eluting Stents","volume":"9","author":"Elgendy IY","year":"2016","journal-title":"Circ Cardiovasc Interv"},{"issue":"7","key":"ref43","first-page":"573","article-title":"Dissection of the Right Coronary Artery as a Complication after the IVUS Procedure","volume":"32","author":"Kordish I","year":"2007","journal-title":"Herz"},{"issue":"10150","key":"ref44","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1016\/S0140-6736(18)31719-7","article-title":"Drug-Coated Balloons for Small Coronary Artery Disease (BASKET-SMALL 2): An Open-Label Randomised Non-Inferiority Trial","volume":"392","author":"Jeger RV","year":"2018","journal-title":"Lancet"},{"issue":"2","key":"ref45","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1007\/s40119-016-0064-4","article-title":"Drug-Eluting Balloons in the Treatment of Coronary De Novo Lesions: A Comprehensive Review","volume":"5","author":"Richelsen RK","year":"2016","journal-title":"Cardiol Ther"}],"container-title":["Arquivos Brasileiros de Cardiologia"],"original-title":["Registry of Percutaneous Coronary Interventions in Very Small-Caliber Vessels: Analysis of a Sirolimus-Eluting Stent and Other Contemporary Drug-Eluting Stents"],"link":[{"URL":"https:\/\/abccardiol.org\/wp-content\/uploads\/articles_xml\/0066-782x-abc-123-2-e20250145\/0066-782x-abc-123-2-e20250145.x74770.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T18:54:32Z","timestamp":1773687272000},"score":1,"resource":{"primary":{"URL":"https:\/\/abccardiol.org\/article\/registro-de-intervencoes-coronarias-em-vasos-de-muito-pequeno-calibre-analise-de-stent-eluidor-de-sirolimus-e-outros-stents-contemporaneos\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":45,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026]]}},"alternative-id":["S0066-782X2026000200602"],"URL":"https:\/\/doi.org\/10.36660\/abc.20250145","relation":{"is-translation-of":[{"id-type":"doi","id":"10.36660\/abc.20250145i","asserted-by":"subject"},{"id-type":"doi","id":"10.36660\/abc.20250145i","asserted-by":"object"}]},"ISSN":["1678-4170","0066-782X"],"issn-type":[{"value":"1678-4170","type":"electronic"},{"value":"0066-782X","type":"print"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"e20250145"}}