{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T04:33:06Z","timestamp":1772253186606,"version":"3.50.1"},"reference-count":50,"publisher":"Sociedade Brasileira de Cardiologia","issue":"11","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arq. Bras. Cardiol."],"abstract":"<jats:p>Resumo A abla\u00e7\u00e3o da fibrila\u00e7\u00e3o atrial (FA) tem sido cada vez mais utilizada como uma estrat\u00e9gia eficaz para o controle do ritmo, resultando na redu\u00e7\u00e3o da carga arr\u00edtmica, melhora da qualidade de vida e, em casos selecionados, diminui\u00e7\u00e3o da mortalidade. No entanto, por se tratar de um procedimento invasivo, envolve riscos inerentes. Complica\u00e7\u00f5es esof\u00e1gicas graves, como perfura\u00e7\u00e3o esof\u00e1gica ou f\u00edstula \u00e1trio-esof\u00e1gica, embora raras (com incid\u00eancia variando de 0,025% a 0,113%), est\u00e3o associadas a significativa morbidade e mortalidade. Diversos fatores de risco para les\u00e3o esof\u00e1gica foram identificados, incluindo caracter\u00edsticas relacionadas tanto ao paciente quanto ao procedimento. Para mitigar esses riscos durante a abla\u00e7\u00e3o por radiofrequ\u00eancia (RF), v\u00e1rias medidas preventivas foram adotadas, como o uso de cateteres com controle de for\u00e7a de contato, aplica\u00e7\u00f5es de energia de alta pot\u00eancia e curta dura\u00e7\u00e3o, al\u00e9m de estrat\u00e9gias de prote\u00e7\u00e3o como monitoramento da temperatura esof\u00e1gica, dispositivos de deslocamento e t\u00e9cnicas de resfriamento. Les\u00f5es esof\u00e1gicas profundas detectadas por endoscopia de vigil\u00e2ncia s\u00e3o consideradas precursoras de complica\u00e7\u00f5es mais graves e, portanto, merecem aten\u00e7\u00e3o especial. O monitoramento intensivo de pacientes com essas les\u00f5es pode ser crucial para permitir o diagn\u00f3stico precoce e a interven\u00e7\u00e3o oportuna, prevenindo a progress\u00e3o para complica\u00e7\u00f5es mais graves. Embora a terapia por abla\u00e7\u00e3o com campo pulsado \u2013 que apresenta menor risco para o es\u00f4fago e outras estruturas adjacentes \u2013 ainda n\u00e3o esteja amplamente dispon\u00edvel, a implementa\u00e7\u00e3o de estrat\u00e9gias eficazes de monitoramento pode melhorar significativamente os desfechos cl\u00ednicos e aumentar a seguran\u00e7a dos pacientes no contexto da abla\u00e7\u00e3o por RF da FA.<\/jats:p>","DOI":"10.36660\/abc.20250290","type":"journal-article","created":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T15:46:17Z","timestamp":1768923977000},"source":"Crossref","is-referenced-by-count":0,"title":["Complica\u00e7\u00f5es Esof\u00e1gicas Graves ap\u00f3s Abla\u00e7\u00e3o de Fibrila\u00e7\u00e3o Atrial: Ainda Devemos Nos Preocupar?"],"prefix":"10.36660","volume":"122","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3617-9589","authenticated-orcid":false,"given":"Anibal Pires","family":"Borges","sequence":"first","affiliation":[{"name":"Universidade Federal do Rio Grande do Sul,  Brasil; Santa Casa de Porto Alegre,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos","family":"Kalil","sequence":"additional","affiliation":[{"name":"Santa Casa de Porto Alegre,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Josep","family":"Brugada","sequence":"additional","affiliation":[{"name":"Santa Casa de Porto Alegre,  Brasil; Universitat de Barcelona,  Espanha; University of Barcelona,  Espanha"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 Plutarco Guti\u00e9rrez","family":"Yanez","sequence":"additional","affiliation":[{"name":"Santa Casa de Porto Alegre,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pablo da Costa","family":"Soliz","sequence":"additional","affiliation":[{"name":"Santa Casa de Porto Alegre,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8232-3310","authenticated-orcid":false,"given":"Marco Aurelio Lumertz","family":"Saffi","sequence":"additional","affiliation":[{"name":"Universidade Federal do Rio Grande do Sul,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0327-3392","authenticated-orcid":false,"given":"Anderson Donelli da","family":"Silveira","sequence":"additional","affiliation":[{"name":"Universidade Federal do Rio Grande do Sul,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1489-5349","authenticated-orcid":false,"given":"Maur\u00edcio","family":"Pimentel","sequence":"additional","affiliation":[{"name":"Universidade Federal do Rio Grande do Sul,  Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"22636","published-online":{"date-parts":[[2025]]},"reference":[{"issue":"36","key":"ref1","doi-asserted-by":"crossref","first-page":"3314","DOI":"10.1093\/eurheartj\/ehae176","article-title":"2024 ESC Guidelines for the Management of Atrial Fibrillation Developed in Collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"45","author":"Van Gelder IC","year":"2024","journal-title":"Eur Heart J"},{"issue":"4","key":"ref2","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1161\/CIRCEP.108.824789","article-title":"Treatment of Atrial Fibrillation with Antiarrhythmic Drugs or Radiofrequency Ablation: Two Systematic Literature Reviews and Meta-Analyses","volume":"2","author":"Calkins H","year":"2009","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"11","key":"ref3","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1001\/jama.2019.0335","article-title":"Effect of Catheter Ablation vs Antiarrhythmic Medication on Quality of Life in Patients with Atrial Fibrillation: The CAPTAF Randomized Clinical Trial","volume":"321","author":"Blomstr\u00f6m-Lundqvist C","year":"2019","journal-title":"JAMA"},{"issue":"13","key":"ref4","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1001\/jama.2019.0693","article-title":"Effect of Catheter Ablation vs Antiarrhythmic Drug Therapy on Mortality, Stroke, Bleeding, and Cardiac Arrest Among Patients with Atrial Fibrillation: The CABANA Randomized Clinical Trial","volume":"321","author":"Packer DL","year":"2019","journal-title":"JAMA"},{"issue":"5","key":"ref5","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1056\/NEJMoa1707855","article-title":"Catheter Ablation for Atrial Fibrillation with Heart Failure","volume":"378","author":"Marrouche NF","year":"2018","journal-title":"N Engl J Med"},{"issue":"15","key":"ref6","doi-asserted-by":"crossref","first-page":"1380","DOI":"10.1056\/NEJMoa2306037","article-title":"Catheter Ablation in End-Stage Heart Failure with Atrial Fibrillation","volume":"389","author":"Sohns C","year":"2023","journal-title":"N Engl J Med"},{"issue":"6","key":"ref7","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1002\/joa3.13082","article-title":"2024 European Heart Rhythm Association\/Heart Rhythm Society\/Asia Pacific Heart Rhythm Society\/Latin American Heart Rhythm Society Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation","volume":"40","author":"Tzeis S","year":"2024","journal-title":"J Arrhythm"},{"issue":"21","key":"ref8","doi-asserted-by":"crossref","first-page":"2089","DOI":"10.1016\/j.jacc.2023.03.418","article-title":"Procedure-Related Complications of Catheter Ablation for Atrial Fibrillation","volume":"81","author":"Benali K","year":"2023","journal-title":"J Am Coll Cardiol"},{"issue":"8","key":"ref9","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1046\/j.1540-8167.2004.04083.x","article-title":"Left Atrial-Esophageal Fistula Following Radiofrequency Catheter Ablation of Atrial Fibrillation","volume":"15","author":"Scanavacca MI","year":"2004","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"22","key":"ref10","doi-asserted-by":"crossref","first-page":"2724","DOI":"10.1161\/01.CIR.0000131866.44650.46","article-title":"Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial Fibrillation","volume":"109","author":"Pappone C","year":"2004","journal-title":"Circulation"},{"issue":"2","key":"ref11","first-page":"250","article-title":"Atrial-Oesophageal Fistula Following Percutaneous Radiofrequency Catheter Ablation of Atrial Fibrillation: The Risk Still Persists","volume":"19","author":"Vasconcelos JTM","year":"2017","journal-title":"Europace"},{"issue":"27","key":"ref12","doi-asserted-by":"crossref","first-page":"2458","DOI":"10.1093\/eurheartj\/ehad250","article-title":"A Worldwide Survey on Incidence, Management, and Prognosis of Oesophageal Fistula Formation Following Atrial Fibrillation Catheter Ablation: The POTTER-AF Study","volume":"44","author":"Tilz RR","year":"2023","journal-title":"Eur Heart J"},{"issue":"47","key":"ref13","doi-asserted-by":"crossref","first-page":"5004","DOI":"10.1093\/eurheartj\/ehad689","article-title":"Early Identification of Oesophageal Lesions after Atrial Fibrillation Ablation to Prevent Atrio-Oesophageal Fistula","volume":"44","author":"Scanavacca M","year":"2023","journal-title":"Eur Heart J"},{"issue":"13","key":"ref14","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1161\/CIRCULATIONAHA.117.025827","article-title":"Esophageal Injury and Atrioesophageal Fistula Caused by Ablation for Atrial Fibrillation","volume":"136","author":"Kapur S","year":"2017","journal-title":"Circulation"},{"issue":"4","key":"ref15","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1007\/s00276-019-02327-3","article-title":"Translational Anatomy of the Left Atrium and Esophagus as Relevant to the Pulmonary Vein Antral Isolation for Atrial Fibrillation","volume":"42","author":"Gupta T","year":"2020","journal-title":"Surg Radiol Anat"},{"issue":"7","key":"ref16","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1016\/j.hrthm.2019.01.030","article-title":"Endoscopic Evaluation of the Esophagus after Catheter Ablation of Atrial Fibrillation Using Contiguous and Optimized Radiofrequency Applications","volume":"16","author":"Wolf M","year":"2019","journal-title":"Heart Rhythm"},{"issue":"4","key":"ref17","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1007\/s10840-024-01922-8","article-title":"Surveillance of Esophageal Injury after Atrial Fibrillation Catheter Ablation","volume":"68","author":"Ferraz AP","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"issue":"2","key":"ref18","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.hrthm.2018.09.027","article-title":"Temporal Relationships between Esophageal Injury Type and Progression in Patients Undergoing Atrial Fibrillation Catheter Ablation","volume":"16","author":"Yarlagadda B","year":"2019","journal-title":"Heart Rhythm"},{"issue":"8","key":"ref19","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.117.005233","article-title":"Progression from Esophageal Thermal Asymptomatic Lesion to Perforation Complicating Atrial Fibrillation Ablation: A Single-Center Registry","volume":"10","author":"Halbfass P","year":"2017","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"5","key":"ref20","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae107","article-title":"Incidence and Predictors of Thermal Oesophageal and Vagus Nerve Injuries in Ablation Index-Guided High-Power-Short-Duration ablation of Atrial Fibrillation: A prospective Study","volume":"26","author":"Wolff C","year":"2024","journal-title":"Europace"},{"issue":"9","key":"ref21","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1016\/j.hrthm.2010.02.027","article-title":"Identification of a High-Risk Population for Esophageal Injury during Radiofrequency Catheter Ablation of Atrial Fibrillation: Procedural and Anatomical Considerations","volume":"7","author":"Martinek M","year":"2010","journal-title":"Heart Rhythm"},{"issue":"6","key":"ref22","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1016\/j.hrthm.2011.01.045","article-title":"Prevalence and Characteristics of Asymptomatic Excessive Transmural Injury after Radiofrequency Catheter Ablation of Atrial Fibrillation","volume":"8","author":"Yamasaki H","year":"2011","journal-title":"Heart Rhythm"},{"issue":"1","key":"ref23","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.joa.2014.05.002","article-title":"Incidence of Esophageal Injury after Pulmonary Vein Isolation in Patients with a Low Body Mass Index and Esophageal Temperature Monitoring at a 39 \u00b0C Setting","volume":"31","author":"Kiuchi K","year":"2015","journal-title":"J Arrhythm"},{"issue":"8","key":"ref24","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1111\/pace.14551","article-title":"Esophageal Thermal Lesions in Radiofrequency Ablation for Atrial Fibrillation: A Prospective Comparative Study of Thermal Sensors","volume":"45","author":"Arai S","year":"2022","journal-title":"Pacing Clin Electrophysiol"},{"issue":"6","key":"ref25","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1016\/j.hrthm.2021.02.003","article-title":"Temperature Monitoring and Temperature-Driven Irrigated Radiofrequency Energy Titration do Not Prevent Thermally Induced Esophageal Lesions in Pulmonary Vein Isolation: A Randomized Study Controlled By Esophagoscopy Before and after Catheter Ablation","volume":"18","author":"Meininghaus DG","year":"2021","journal-title":"Heart Rhythm"},{"issue":"10","key":"ref26","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1093\/europace\/euaa209","article-title":"Oesophageal Probe Evaluation in Radiofrequency Ablation of Atrial Fibrillation (OPERA): Results from a Prospective Randomized Trial","volume":"22","author":"Schoene K","year":"2020","journal-title":"Europace"},{"issue":"11","key":"ref27","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.118.006681","article-title":"High-Resolution Infrared Thermal Imaging of the Esophagus during Atrial Fibrillation Ablation as a Predictor of Endoscopically Detected Thermal Lesions: Results from the HEAT-AF Study","volume":"11","author":"Deneke T","year":"2018","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"4","key":"ref28","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1111\/jce.16213","article-title":"Machine Learning Identifies Esophageal Luminal Temperature Patterns Associated with Thermal Injury in Catheter Ablation for Atrial Fibrillation","volume":"35","author":"Chahine Y","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"2","key":"ref29","first-page":"82","article-title":"Impact of Contact Force Technology on Reducing the Recurrence and Major Complications of Atrial Fibrillation Ablation: A Systematic Review and Meta-Analysis","volume":"17","author":"Zhou X","year":"2017","journal-title":"Anatol J Cardiol"},{"issue":"12","key":"ref30","doi-asserted-by":"crossref","first-page":"1909","DOI":"10.1093\/europace\/euac103","article-title":"Oesophageal Safety in Voltage-Guided Atrial Fibrillation Ablation Using Ablation Index or Contact Force Only: A Prospective Comparison","volume":"24","author":"Schade A","year":"2022","journal-title":"Europace"},{"issue":"3","key":"ref31","doi-asserted-by":"crossref","DOI":"10.36660\/abc.20230913i","article-title":"Esophageal Protection Strategies for Ablation of Atrial Fibrillation: Comparative Results of Consecutive Endoscopic Evaluation","volume":"122","author":"Ferraz AP","year":"2025","journal-title":"Arq Bras Cardiol"},{"issue":"1","key":"ref32","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1080\/17434440.2024.2447809","article-title":"Proactive Esophageal Cooling during Radiofrequency Cardiac Ablation: Data Update Including Applications in Very High-Power Short Duration Ablation","volume":"22","author":"Sharkoski T","year":"2025","journal-title":"Expert Rev Med Devices"},{"issue":"1","key":"ref33","article-title":"Characteristics of Atrial Fibrillation Patients Suffering Esophageal Injury Caused by Ablation for Atrial Fibrillation","volume":"10","author":"Zhang P","year":"2020","journal-title":"Sci Rep"},{"issue":"5","key":"ref34","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.118.007044","article-title":"RESCUE-AF in Patients Undergoing Atrial Fibrillation Ablation: The RESCUE-AF Trial","volume":"12","author":"Zhang X","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"12","key":"ref35","first-page":"1583","article-title":"High-Power Radiofrequency Catheter Ablation of Atrial Fibrillation: Using Late Gadolinium Enhancement Magnetic Resonance Imaging as a Novel Index of Esophageal Injury","volume":"4","author":"Baher A","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"issue":"7","key":"ref36","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1111\/pace.14286","article-title":"Reduced Esophageal Heating in High-Power Short-Duration Atrial Fibrillation Ablation in the Contact Force Catheter Era","volume":"44","author":"Vassallo F","year":"2021","journal-title":"Pacing Clin Electrophysiol"},{"issue":"10","key":"ref37","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1016\/j.jacep.2020.05.022","article-title":"Esophageal Endoscopy after Catheter Ablation of Atrial Fibrillation Using Ablation-Index Guided High-Power: Frankfurt AI-HP ESO-I","volume":"6","author":"Chen S","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"issue":"4","key":"ref38","article-title":"Intraluminal Esophageal Temperature Monitoring Using the Circa S-Cath\u2122 Temperature Probe to Guide Left Atrial Ablation in Patients with Atrial Fibrillation","volume":"13","author":"Bhuta S","year":"2020","journal-title":"J Atr Fibrillation"},{"issue":"5","key":"ref39","article-title":"Intraluminal Esophageal Temperature Monitoring Using the Circa S-Cath\u2122 Temperature Probe to Guide Left Atrial Ablation in Patients with Atrial Fibrillation","volume":"13","author":"Wm Leung L","year":"2021","journal-title":"J Atr Fibrillation"},{"issue":"2","key":"ref40","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1161\/CIRCEP.110.960328","article-title":"Luminal Esophageal Temperature Monitoring with a Deflectable Esophageal Temperature Probe and Intracardiac Echocardiography May Reduce Esophageal Injury during Atrial Fibrillation Ablation Procedures: Results of a Pilot Study","volume":"4","author":"Leite LR","year":"2011","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"1","key":"ref41","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.jacep.2023.09.004","article-title":"EsophAguS Deviation during RadiofrequencY Ablation of Atrial Fibrillation: The EASY AF Trial","volume":"10","author":"Weiss R","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"issue":"1","key":"ref42","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.jacep.2023.10.019","article-title":"A Hard Look at EASY AF","volume":"10","author":"Kaul R","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"issue":"5","key":"ref43","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad080","article-title":"Role of Oesophageal Cooling in the Prevention of Oesophageal Injury in Atrial Fibrillation Catheter Ablation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials","volume":"25","author":"Hamed M","year":"2023","journal-title":"Europace"},{"issue":"12","key":"ref44","doi-asserted-by":"crossref","first-page":"2558","DOI":"10.1016\/j.jacep.2023.08.022","article-title":"Atrioesophageal Fistula Rates Before and after Adoption of Active Esophageal Cooling during Atrial Fibrillation Ablation","volume":"9","author":"Sanchez J","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"issue":"5","key":"ref45","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1016\/j.jacep.2021.02.014","article-title":"Pulsed Field Ablation of Paroxysmal Atrial Fibrillation: 1-Year Outcomes of IMPULSE, PEFCAT, and PEFCAT II","volume":"7","author":"Reddy VY","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"issue":"18","key":"ref46","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","article-title":"Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation","volume":"389","author":"Reddy VY","year":"2023","journal-title":"N Engl J Med"},{"issue":"6","key":"ref47","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.hroo.2024.04.012","article-title":"Pulsed-Field Ablation versus Thermal Ablation for Atrial Fibrillation: A Meta-Analysis","volume":"5","author":"Campos MCAV","year":"2024","journal-title":"Heart Rhythm O2"},{"issue":"3","key":"ref48","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1007\/s12325-023-02765-x","article-title":"Comparative Safety of Pulsed Field Ablation and Cryoballoon Ablation Technologies for Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation: A Critical Literature Review and Indirect Treatment Comparison","volume":"41","author":"Maccioni S","year":"2024","journal-title":"Adv Ther"},{"issue":"7","key":"ref49","doi-asserted-by":"crossref","first-page":"2020","DOI":"10.1038\/s41591-024-03114-3","article-title":"Safety of Pulsed Field Ablation in More than 17,000 Patients with Atrial Fibrillation in the MANIFEST-17K Study","volume":"30","author":"Ekanem E","year":"2024","journal-title":"Nat Med"},{"key":"ref50","doi-asserted-by":"crossref","DOI":"10.15420\/aer.2023.16","article-title":"Endocardial Pulsed Field Ablation and the Oesophagus: Are Atrio-Oesophageal Fistulas Now History?","volume":"13","author":"Nies M","year":"2024","journal-title":"Arrhythm Electrophysiol Rev"}],"container-title":["Arquivos Brasileiros de Cardiologia"],"original-title":["Severe Esophageal Complications Following Atrial Fibrillation Ablation: Should We Still Be Concerned?"],"link":[{"URL":"https:\/\/abccardiol.org\/wp-content\/uploads\/articles_xml\/0066-782x-abc-122-11-e20250290\/0066-782x-abc-122-11-e20250290.x96239.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T15:46:24Z","timestamp":1768923984000},"score":1,"resource":{"primary":{"URL":"https:\/\/abccardiol.org\/article\/complicacoes-esofagicas-graves-apos-ablacao-de-fibrilacao-atrial-ainda-devemos-nos-preocupar\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":50,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025]]}},"alternative-id":["S0066-782X2025001100401"],"URL":"https:\/\/doi.org\/10.36660\/abc.20250290","relation":{"is-translation-of":[{"id-type":"doi","id":"10.36660\/abc.20250290i","asserted-by":"subject"},{"id-type":"doi","id":"10.36660\/abc.20250290i","asserted-by":"object"}]},"ISSN":["1678-4170","0066-782X"],"issn-type":[{"value":"1678-4170","type":"electronic"},{"value":"0066-782X","type":"print"}],"subject":[],"published":{"date-parts":[[2025]]},"article-number":"e20250290"}}