{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T17:09:16Z","timestamp":1793984956728,"version":"4.8.0"},"reference-count":91,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:00:00Z","timestamp":1784160000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:00:00Z","timestamp":1784160000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Behav Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Wearable devices enable continuous monitoring of physiological signals in real\u2010world settings, yet a standardized approach for synchronizing signals across devices remains lacking. We present a generalizable, user\u2010friendly pipeline that enables synchronization of any two devices capturing the same physiological signals, without requiring coding expertise. The pipeline performs resampling, dynamic time warping alignment, amplitude correction via wavelet transforms, and signal standardization, followed by agreement analyses at both waveform and feature levels. To demonstrate its validity, we applied the pipeline to a case study comparing two research\u2010grade devices, the Empatica E4 and the EmbracePlus, using up to 48\u00a0h of concurrent recordings from 31 participants. We compared signal\u2010level agreement across waveform similarity, amplitude distribution, spectral content, and extracted features between the two research\u2010grade devices to determine their interchangeability for longitudinal and multi\u2010site studies. Specifically, we aimed to determine how well these devices agree at the signal level and to identify which physiological signals are most robust to device\u2010specific variability. Four signals were examined (blood volume pulse, electrodermal activity, accelerometry, and temperature) using NeuroKit2 and FLIRT. We computed Pearson and concordance correlation coefficients, Bland\u2013Altman bias and limits of agreement, root mean squared error (RMSE), KL divergence, spectral coherence, mutual information, and feature\u2010level correlations using NeuroKit2 and FLIRT. Results showed near\u2010perfect agreement for BVP (concordance correlation coefficient (CCC) \u2248 1.0; coherence \u2264 0.98) and phasic EDA features (CCC 0.85\u20130.99), whereas tonic EDA, temperature, and accelerometry exhibited systematic amplitude biases (EmbracePlus lower) and axis\u2010dependent variability (\n                    <jats:italic>Z<\/jats:italic>\n                    \u2010axis CCC = 0.85;\n                    <jats:italic>Y<\/jats:italic>\n                    \u2010axis = 0.19). Relative signal dynamics were preserved across devices despite differences in absolute levels. These findings support integration of BVP, EDA, and TEMP data across E4 and EmbracePlus with proper preprocessing, while highlighting calibration needs for movement signals.\n                  <\/jats:p>","DOI":"10.3758\/s13428-026-03097-8","type":"journal-article","created":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T15:50:45Z","timestamp":1784217045000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Standardized synchronization and validation pipeline for physiological biomarkers across multiple devices"],"prefix":"10.3758","volume":"58","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-1223-7178","authenticated-orcid":false,"given":"Selin","family":"Acan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cl\u00e0udia","family":"Valenzuela\u2010Pascual","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Filippo","family":"Corponi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryan M.","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diego","family":"Hidalgo\u2010Mazzei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dick","family":"Thijssen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gideon","family":"Vos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Bogaerts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erno","family":"Hermans","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitra","family":"Baratchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Dresler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"De Looff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,16]]},"reference":[{"key":"3097_CR1","doi-asserted-by":"publisher","first-page":"15448","DOI":"10.1038\/s41598-022-18356-9","volume":"12","author":"C Alfonso","year":"2022","unstructured":"Alfonso, C., Garc\u00eda-Gonz\u00e1lez, M. A., Parrado, E., Gil-Rojas, J., Ramos-Castro, J., & CapdevilaOrt\u00eds, L. (2022). Agreement between two photoplethysmography-based wearable devices for monitoring heart rate during different physical activity situations: A new analysis methodology. Scientific Reports, 12, 15448. https:\/\/doi.org\/10.1038\/s41598-022-18356-9","journal-title":"Scientific Reports"},{"issue":"3","key":"3097_CR2","doi-asserted-by":"publisher","first-page":"R1","DOI":"10.1088\/0967-3334\/28\/3\/R01","volume":"28","author":"J Allen","year":"2007","unstructured":"Allen, J. (2007). Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement, 28(3), R1\u2013R39. https:\/\/doi.org\/10.1088\/0967-3334\/28\/3\/R01","journal-title":"Physiological Measurement"},{"issue":"31","key":"3097_CR3","doi-asserted-by":"publisher","first-page":"eabb8308","DOI":"10.1126\/sciadv.abb8308","volume":"6","author":"M Bariya","year":"2020","unstructured":"Bariya, M., Li, L., Ghattamaneni, R., & Javey, A. (2020). Glove-based sensors for multimodal monitoring of natural sweat. Science Advances, 6(31), eabb8308. https:\/\/doi.org\/10.1126\/sciadv.abb8308","journal-title":"Science Advances"},{"issue":"1","key":"3097_CR4","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.jneumeth.2010.04.028","volume":"190","author":"M Benedek","year":"2010","unstructured":"Benedek, M., & Kaernbach, C. (2010). A continuous measure of phasic electrodermal activity. Journal of Neuroscience Methods, 190(1), 80\u201391. https:\/\/doi.org\/10.1016\/j.jneumeth.2010.04.028","journal-title":"Journal of Neuroscience Methods"},{"issue":"9","key":"3097_CR5","doi-asserted-by":"publisher","first-page":"985","DOI":"10.1161\/hc3401.093093","volume":"104","author":"L Bernardi","year":"2001","unstructured":"Bernardi, L., Gabutti, A., Porta, C., & Spicuzza, L. (2001). Slow breathing reduces chemoreflex response to hypoxia and hypercapnia, and increases baroreflex sensitivity. Circulation, 104(9), 985\u2013990. https:\/\/doi.org\/10.1161\/hc3401.093093","journal-title":"Circulation"},{"issue":"8476","key":"3097_CR6","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland, J. M., & Altman, D. G. (1986). Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet, 1(8476), 307\u2013310. https:\/\/doi.org\/10.1016\/S0140-6736(86)90837-8","journal-title":"The Lancet"},{"key":"3097_CR7","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4614-1126-0","volume-title":"Electrodermal activity","author":"W Boucsein","year":"2012","unstructured":"Boucsein, W. (2012). Electrodermal activity (2nd ed.). Springer. https:\/\/doi.org\/10.1007\/978-1-4614-1126-0","edition":"2nd ed."},{"issue":"8","key":"3097_CR8","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1111\/j.1469-8986.2012.01384.x","volume":"49","author":"W Boucsein","year":"2012","unstructured":"Boucsein, W., et al. (2012). Publication recommendations for electrodermal measurements. Psychophysiology, 49(8), 1017\u20131034. https:\/\/doi.org\/10.1111\/j.1469-8986.2012.01384.x","journal-title":"Psychophysiology"},{"key":"3097_CR9","volume-title":"A guide for analysing electrodermal activity (EDA) & skin conductance responses (SCRs) for psychological experiments","author":"J Braithwaite","year":"2015","unstructured":"Braithwaite, J., Watson, D., Jones, R., & Rowe, M. (2015). A guide for analysing electrodermal activity (EDA) & skin conductance responses (SCRs) for psychological experiments. University of Birmingham. https:\/\/www.birmingham.ac.uk\/documents\/college-les\/psych\/saal\/guide-electrodermal-activity.pdf"},{"issue":"5","key":"3097_CR10","doi-asserted-by":"publisher","first-page":"e0216153","DOI":"10.1371\/journal.pone.0216153","volume":"14","author":"R Castaldo","year":"2019","unstructured":"Castaldo, R., Melillo, P., Bracale, M., Caserta, M., Triassi, M., & Pecchia, L. (2019). Heart rate variability monitoring during physical activity: A systematic review. PLOS ONE, 14(5), e0216153. https:\/\/doi.org\/10.1371\/journal.pone.0216153","journal-title":"PLOS ONE"},{"issue":"3","key":"3097_CR11","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.artmed.2012.09.003","volume":"56","author":"M Chan","year":"2012","unstructured":"Chan, M., Est\u00e8ve, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012). Smart wearable systems: Current status and future challenges. Artificial Intelligence in Medicine, 56(3), 137\u2013156. https:\/\/doi.org\/10.1016\/j.artmed.2012.09.003","journal-title":"Artificial Intelligence in Medicine"},{"issue":"9","key":"3097_CR12","doi-asserted-by":"publisher","first-page":"2700","DOI":"10.3390\/s20092700","volume":"20","author":"Y Chen","year":"2020","unstructured":"Chen, Y., Xu, J., Zhou, R., Zheng, Y., Huang, J., & Liu, J. (2020). An improved dynamic time warping algorithm for aligning biomedical signals with uneven sampling frequencies. Sensors, 20(9), 2700. https:\/\/doi.org\/10.3390\/s20092700","journal-title":"Sensors"},{"issue":"18","key":"3097_CR13","doi-asserted-by":"publisher","first-page":"6283","DOI":"10.3390\/s21186283","volume":"21","author":"Z Chen","year":"2021","unstructured":"Chen, Z., Fu, J., Peng, Y., Chen, T., Zhang, L., & Yuan, C. (2021). Baseline correction of acceleration data based on a hybrid EMD\u2013DNN method. Sensors, 21(18), 6283. https:\/\/doi.org\/10.3390\/s21186283","journal-title":"Sensors"},{"key":"3097_CR14","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1109\/MetroXRAINE62247.2024.10797108","volume-title":"Proceedings of the 2024 IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE)","author":"S Coelli","year":"2024","unstructured":"Coelli, S., Carrara, M., Bianchi, A. M., De Tommaso, M., Actis-Grosso, R., & Reali, P. (2024). Comparing consumer and research-grade wristbands for inter-beat intervals monitoring. Proceedings of the 2024 IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) (pp. 201\u2013206). IEEE. https:\/\/doi.org\/10.1109\/MetroXRAINE62247.2024.10797108"},{"issue":"20","key":"3097_CR15","doi-asserted-by":"publisher","first-page":"8423","DOI":"10.3390\/s23208423","volume":"23","author":"S Costantini","year":"2023","unstructured":"Costantini, S., Chiappini, M., Malerba, G., Dei, C., Falivene, A., Arlati, S., Colombo, V., Biffi, E., & Storm, F. A. (2023). Wrist-worn sensor validation for heart rate variability and electrodermal activity detection in a stressful driving environment. Sensors, 23(20), 8423. https:\/\/doi.org\/10.3390\/s23208423","journal-title":"Sensors"},{"issue":"1","key":"3097_CR16","first-page":"3","volume":"17","author":"B Cowley","year":"2014","unstructured":"Cowley, B., Fantato, M., Jennett, C., Ruskov, M., & Ravaja, N. (2014). Learning when serious: Psychophysiological evaluation of a technology-enhanced learning game. Educational Technology & Society, 17(1), 3\u201316. https:\/\/www.jstor.org\/stable\/jeductechsoci.17.1.3.","journal-title":"Educational Technology & Society"},{"issue":"2","key":"3097_CR17","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1023\/A:1009982611386","volume":"15","author":"LA Critchley","year":"1999","unstructured":"Critchley, L. A., & Critchley, J. A. (1999). A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. Journal of Clinical Monitoring and Computing, 15(2), 85\u201391. https:\/\/doi.org\/10.1023\/A:1009982611386","journal-title":"Journal of Clinical Monitoring and Computing"},{"key":"3097_CR18","doi-asserted-by":"publisher","unstructured":"Daza, R., Gomez, L. F., Morales, A., Fierrez, J., Tolosana, R., Cobos, R., & Ortega-Garcia, J. (2023). MATT: Multimodal attention level estimation for e-learning platforms. arXiv. https:\/\/doi.org\/10.48550\/arXiv.2301.09174\n\u2060","DOI":"10.48550\/arXiv.2301.09174"},{"issue":"1","key":"3097_CR19","doi-asserted-by":"publisher","first-page":"103","DOI":"10.4103\/mgmj.mgmj_232_22","volume":"9","author":"CA Deshmukh","year":"2022","unstructured":"Deshmukh, C. A., Jindal, G. D., Bagal, U. R., & Nagare, G. D. (2022). Pulse arrival time: Measurement and clinical applications. MGM Journal of Medical Sciences, 9(1), 103\u2013111. https:\/\/doi.org\/10.4103\/mgmj.mgmj_232_22","journal-title":"MGM Journal of Medical Sciences"},{"issue":"1","key":"3097_CR20","doi-asserted-by":"publisher","first-page":"14","DOI":"10.2174\/157340312801215782","volume":"8","author":"M Elgendi","year":"2012","unstructured":"Elgendi, M. (2012). On the analysis of fingertip photoplethysmogram signals. Current Cardiology Reviews, 8(1), 14\u201325. https:\/\/doi.org\/10.2174\/157340312801215782","journal-title":"Current Cardiology Reviews"},{"issue":"10","key":"3097_CR21","doi-asserted-by":"publisher","first-page":"e76585","DOI":"10.1371\/journal.pone.0076585","volume":"8","author":"M Elgendi","year":"2013","unstructured":"Elgendi, M., Norton, I., Brearley, M., Abbott, D., & Schuurmans, D. (2013). Systolic peak detection in acceleration photoplethysmograms measured from emergency responders in tropical conditions. PLoS One, 8(10), e76585. https:\/\/doi.org\/10.1371\/journal.pone.0076585","journal-title":"PLoS One"},{"key":"3097_CR22","volume-title":"E4 wristband product page","author":"Empatica","year":"2020","unstructured":"Empatica. (2020). E4 wristband product page. Empatica Store. https:\/\/store.empatica.com\/products\/e4-wristbands"},{"key":"3097_CR23","unstructured":"Empatica. (2021). EmbracePlus user manual (Rev. 4.0). Empatica. https:\/\/s3.amazonaws.com\/box.empatica.com\/manuals\/embraceplus\/EmbracePlus-UserManual-UM-22-Rev-4.0.pdf\u2060"},{"key":"3097_CR24","unstructured":"Empatica. (2022). Empatica E4 EDA\/GSR wristband specifications. iMotions. https:\/\/imotions.com\/products\/hardware\/empatica-e4-eda-gsr-wristband\/"},{"key":"3097_CR25","unstructured":"Empatica Inc. (2014). Empatica E4 wristband technical specifications [Technical specifications]. Empatica Inc. https:\/\/box.empatica.com\/documentation\/20141119_E4_TechSpecs.pdf\u2060"},{"key":"3097_CR26","unstructured":"Empatica Inc. (2025a). Care app says \"EmbracePlus not worn\" [Support article]. Empatica Support. https:\/\/support.empatica.com\/hc\/en-us\/articles\/9368914517789\u2060"},{"key":"3097_CR27","unstructured":"Empatica Inc. (2025b). Raw data in the Empatica cloud [Support article]. Empatica Support. https:\/\/support.empatica.com\/hc\/en-us\/articles\/17727336158365\u2060"},{"key":"3097_CR28","unstructured":"Empatica S.r.l. (2015). E4 user manual [User manual]. Empatica S.r.l. https:\/\/archive.arch.ethz.ch\/emaptics.pdf\u2060"},{"key":"3097_CR29","volume-title":"EmbracePlus FCC report","author":"Empatica S.r.l","year":"2021","unstructured":"Empatica S.r.l. (2021). EmbracePlus FCC report. Federal Communications Commission. https:\/\/fcc.report\/FCC-ID\/2AGGH-EMBPLUS\/5892431.pdf"},{"key":"3097_CR30","volume-title":"Embrace materials","author":"Empatica Support","year":"2025","unstructured":"Empatica Support. (2025). Embrace materials. Empatica Support."},{"key":"3097_CR31","doi-asserted-by":"publisher","first-page":"106461","DOI":"10.1016\/j.cmpb.2021.106461","volume":"212","author":"S F\u00f6ll","year":"2021","unstructured":"F\u00f6ll, S., Maritsch, M., Spinola, F., Mishra, V., Barata, F., Kowatsch, T., & Fleisch, E. (2021). FLIRT: A feature generation toolkit for wearable data. Computer Methods and Programs in Biomedicine, 212, 106461. https:\/\/doi.org\/10.1016\/j.cmpb.2021.106461","journal-title":"Computer Methods and Programs in Biomedicine"},{"key":"3097_CR32","doi-asserted-by":"publisher","first-page":"1371181","DOI":"10.3389\/fcomp.2024.1371181","volume":"6","author":"A Foltyn","year":"2024","unstructured":"Foltyn, A., Deuschel, J., Lang-Richter, N. R., Holzer, N., & Oppelt, M. P. (2024). Evaluating the robustness of multimodal task load estimation models. Frontiers in Computer Science, 6, 1371181. https:\/\/doi.org\/10.3389\/fcomp.2024.1371181","journal-title":"Frontiers in Computer Science"},{"issue":"9","key":"3097_CR33","doi-asserted-by":"publisher","first-page":"e13570","DOI":"10.2196\/13570","volume":"21","author":"Y Gao","year":"2019","unstructured":"Gao, Y., Fang, Y., Wang, X., Weng, M., Bian, J., Li, M., Zhang, Y., & Fu, Q. (2019). Wavelet-based analysis of physical activity and sleep movement data from wearable sensors among obese adults. Journal of Medical Internet Research, 21(9), e13570. https:\/\/doi.org\/10.2196\/13570","journal-title":"Journal of Medical Internet Research"},{"issue":"7","key":"3097_CR34","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1016\/j.jsams.2022.03.006","volume":"25","author":"C Garnett","year":"2022","unstructured":"Garnett, C., Cai, Z., Briggs, A. M., Parry, S. M., & Burton, N. W. (2022). Comparability of five wrist-worn accelerometers during free-living activities in healthy adults: A cross-sectional study. Journal of Science and Medicine in Sport, 25(7), 557\u2013562. https:\/\/doi.org\/10.1016\/j.jsams.2022.03.006","journal-title":"Journal of Science and Medicine in Sport"},{"issue":"1","key":"3097_CR35","doi-asserted-by":"publisher","first-page":"e0228949","DOI":"10.1371\/journal.pone.0228949","volume":"15","author":"G Ger\u0161ak","year":"2020","unstructured":"Ger\u0161ak, G., & Drnov\u0161ek, J. (2020). Electrodermal activity patient simulator. PLOS ONE, 15(1), e0228949. https:\/\/doi.org\/10.1371\/journal.pone.0228949","journal-title":"PLOS ONE"},{"issue":"4","key":"3097_CR36","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1109\/TBME.2015.2474131","volume":"63","author":"A Greco","year":"2016","unstructured":"Greco, A., Valenza, G., & Scilingo, E. P. (2016). CvxEDA: A convex optimization approach to electrodermal activity processing. IEEE Transactions on Biomedical Engineering, 63(4), 797\u2013804. https:\/\/doi.org\/10.1109\/TBME.2015.2474131","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"3097_CR37","doi-asserted-by":"publisher","unstructured":"Haddadi, R., Abdelmounim, E., Hanine, M. E., & Belaguid, A. (2017). Discrete wavelet transform-based algorithm for recognition of QRS complexes. arXiv. https:\/\/doi.org\/10.48550\/arXiv.1703.00075\u2060","DOI":"10.48550\/arXiv.1703.00075"},{"issue":"12","key":"3097_CR38","doi-asserted-by":"publisher","first-page":"e0260952","DOI":"10.1371\/journal.pone.0260952","volume":"16","author":"K Haak","year":"2021","unstructured":"Healthy Brain Study consortium, & Haak, K. (2021). Protocol of the healthy brain study: An accessible resource for understanding the human brain and how it dynamically and individually operates in its bio-social context. PLoS One, 16(12), e0260952. https:\/\/doi.org\/10.1371\/journal.pone.0260952","journal-title":"PLoS One"},{"key":"3097_CR39","doi-asserted-by":"publisher","first-page":"116935","DOI":"10.1016\/j.neuroimage.2020.116935","volume":"219","author":"K Imaizumi","year":"2020","unstructured":"Imaizumi, K., Koike, S., & Kaneko, M. (2020). Dynamic time warping outperforms Pearson correlation in detecting atypical functional connectivity in autism spectrum disorders. NeuroImage, 219, 116935. https:\/\/doi.org\/10.1016\/j.neuroimage.2020.116935","journal-title":"NeuroImage"},{"issue":"1","key":"3097_CR40","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1177\/1932296820948619","volume":"15","author":"M Jacobsen","year":"2020","unstructured":"Jacobsen, M., Scheel, O., & Hejlesen, O. (2020). Noninvasive continuous monitoring of vital signs with wearables: Fit for medical use? Journal of Diabetes Science and Technology, 15(1), 194\u2013210. https:\/\/doi.org\/10.1177\/1932296820948619","journal-title":"Journal of Diabetes Science and Technology"},{"issue":"3","key":"3097_CR41","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1109\/TAFFC.2019.2924678","volume":"11","author":"J Kim","year":"2020","unstructured":"Kim, J., Lee, S., Park, S., & Lee, H. (2020). Robust electrodermal activity signal processing for wearable stress detection using Savitzky-Golay filtering. IEEE Transactions on Affective Computing, 11(3), 482\u2013492. https:\/\/doi.org\/10.1109\/TAFFC.2019.2924678","journal-title":"IEEE Transactions on Affective Computing"},{"issue":"10","key":"3097_CR42","doi-asserted-by":"publisher","first-page":"2237","DOI":"10.3390\/s19102237","volume":"19","author":"HY Lee","year":"2019","unstructured":"Lee, H. Y., Lee, J. S., & Lee, J. W. (2019). IMU consensus exception detection with dynamic time warping. Sensors, 19(10), 2237. https:\/\/doi.org\/10.3390\/s19102237","journal-title":"Sensors"},{"key":"3097_CR43","doi-asserted-by":"publisher","first-page":"198","DOI":"10.3389\/fphys.2019.00198","volume":"10","author":"X Li","year":"2019","unstructured":"Li, X., Liang, C., Zhang, Y., Liu, Y., & Chen, Z. (2019). Quantitative comparison of photoplethysmographic waveform morphology across body sites. Frontiers in Physiology, 10, 198. https:\/\/doi.org\/10.3389\/fphys.2019.00198","journal-title":"Frontiers in Physiology"},{"issue":"11","key":"3097_CR44","doi-asserted-by":"publisher","first-page":"3898","DOI":"10.3390\/s18113898","volume":"18","author":"YP Liang","year":"2018","unstructured":"Liang, Y. P., & Lo, M. T. (2018). Improving PPG-based heart rate estimation in wearable devices with motion artifact reduction via ensemble empirical mode decomposition. Sensors, 18(11), 3898. https:\/\/doi.org\/10.3390\/s18113898","journal-title":"Sensors"},{"issue":"1","key":"3097_CR45","doi-asserted-by":"publisher","first-page":"255","DOI":"10.2307\/2532051","volume":"45","author":"LI-K Lin","year":"1989","unstructured":"Lin, L.I.-K. (1989). A concordance correlation coefficient to evaluate reproducibility. Biometrics, 45(1), 255\u2013268. https:\/\/doi.org\/10.2307\/2532051","journal-title":"Biometrics"},{"issue":"4","key":"3097_CR46","doi-asserted-by":"publisher","first-page":"1689","DOI":"10.3758\/s13428-020-01516-y","volume":"53","author":"D Makowski","year":"2021","unstructured":"Makowski, D., Pham, T., Lau, Z. J., Brammer, J. C., Lespinasse, F., Pham, H., Sch\u00f6lzel, C., & Chen, S. A. (2021). NeuroKit2: A Python toolbox for neurophysiological signal processing. Behavior Research Methods, 53(4), 1689\u20131696. https:\/\/doi.org\/10.3758\/s13428-020-01516-y","journal-title":"Behavior Research Methods"},{"key":"3097_CR47","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.chb.2017.07.005","volume":"76","author":"A Marakhimov","year":"2017","unstructured":"Marakhimov, A., & Joo, J. (2017). Consumer adaptation and infusion of wearable devices for healthcare. Computers in Human Behavior, 76, 135\u2013148. https:\/\/doi.org\/10.1016\/j.chb.2017.07.005","journal-title":"Computers in Human Behavior"},{"issue":"4","key":"3097_CR48","doi-asserted-by":"publisher","first-page":"193","DOI":"10.3233\/SCS-230021","volume":"2","author":"AL Meijer","year":"2023","unstructured":"Meijer, A. L., Arts, L. P., Gomez, R., & van den Broek, E. L. (2023). Electrodermal activity: A continuous monitor of well-being. Journal of Smart Cities and Society, 2(4), 193\u2013207. https:\/\/doi.org\/10.3233\/SCS-230021","journal-title":"Journal of Smart Cities and Society"},{"issue":"18","key":"3097_CR49","doi-asserted-by":"publisher","first-page":"6884","DOI":"10.3390\/s22186884","volume":"22","author":"X Meng","year":"2022","unstructured":"Meng, X., Li, X., Zhang, Z., Wang, Y., & Li, Y. (2022). Using multidimensional dynamic time warping to identify time-varying lead\u2013lag relationships. Sensors, 22(18), 6884. https:\/\/doi.org\/10.3390\/s22186884","journal-title":"Sensors"},{"issue":"11","key":"3097_CR50","doi-asserted-by":"publisher","first-page":"e13441","DOI":"10.1111\/psyp.13441","volume":"56","author":"L Menghini","year":"2019","unstructured":"Menghini, L., Gianfranchi, E., Cellini, N., Patron, E., Tagliabue, M., & Sarlo, M. (2019). Stressing the accuracy: Wrist-worn wearable sensor validation over different conditions. Psychophysiology, 56(11), e13441. https:\/\/doi.org\/10.1111\/psyp.13441","journal-title":"Psychophysiology"},{"issue":"1","key":"3097_CR51","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.neuroimage.2004.01.019","volume":"22","author":"Y Nagai","year":"2004","unstructured":"Nagai, Y., Critchley, H., Featherstone, E., Trimble, M., & Dolan, R. (2004). Activity in ventromedial prefrontal cortex covaries with sympathetic skin conductance level: A physiological account of a \u201cdefault mode\u201d of brain function. NeuroImage, 22(1), 243\u2013251. https:\/\/doi.org\/10.1016\/j.neuroimage.2004.01.019","journal-title":"NeuroImage"},{"key":"3097_CR52","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2020.112105","volume":"312","author":"S Nasiri","year":"2020","unstructured":"Nasiri, S., & Khosravani, M. R. (2020). Progress and challenges in fabrication of wearable sensors for health monitoring. Sensors and Actuators A: Physical, 312, Article 112105. https:\/\/doi.org\/10.1016\/j.sna.2020.112105","journal-title":"Sensors and Actuators A: Physical"},{"issue":"4","key":"3097_CR53","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1007\/s40140-017-0239-0","volume":"7","author":"PM Odor","year":"2017","unstructured":"Odor, P. M. (2017). Cardiac output monitoring: Validation studies\u2014how results should be presented. Current Anesthesiology Reports, 7(4), 327\u2013332. https:\/\/doi.org\/10.1007\/s40140-017-0239-0","journal-title":"Current Anesthesiology Reports"},{"issue":"3","key":"3097_CR54","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1109\/JBHI.2012.2234129","volume":"17","author":"A Pantelopoulos","year":"2013","unstructured":"Pantelopoulos, A., & Bourbakis, N. G. (2013). Real-time human ambulation, activity, and physiological monitoring: Taxonomy of issues, techniques, applications, challenges and limitations. IEEE Journal of Biomedical and Health Informatics, 17(3), 610\u2013628. https:\/\/doi.org\/10.1109\/JBHI.2012.2234129","journal-title":"IEEE Journal of Biomedical and Health Informatics"},{"issue":"2","key":"3097_CR55","doi-asserted-by":"publisher","first-page":"430","DOI":"10.3390\/s25020430","volume":"25","author":"Y Park","year":"2023","unstructured":"Park, Y., Park, S. H., & Ha, J. (2023). Coordinate system alignment of wrist-worn inertial measurement units: Implications for hand motion analysis. Sensors, 25(2), 430. https:\/\/doi.org\/10.3390\/s25020430","journal-title":"Sensors"},{"issue":"4","key":"3097_CR56","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1177\/1754073914565517","volume":"7","author":"RW Picard","year":"2015","unstructured":"Picard, R. W., Fedor, S., & Ayzenberg, Y. (2015). Multiple arousal theory and daily-life electrodermal activity asymmetry. Emotion Review, 7(4), 342\u2013349. https:\/\/doi.org\/10.1177\/1754073914565517","journal-title":"Emotion Review"},{"issue":"9","key":"3097_CR57","doi-asserted-by":"publisher","first-page":"2095","DOI":"10.3390\/s19092095","volume":"19","author":"CM Polo","year":"2019","unstructured":"Polo, C. M., Preger, R., Ramachandran, V., Nussbaum, M. A., & Madigan, M. L. (2019). On placement, location and orientation of wrist-worn tri-axial accelerometers. Sensors, 19(9), 2095. https:\/\/doi.org\/10.3390\/s19092095","journal-title":"Sensors"},{"issue":"10","key":"3097_CR58","doi-asserted-by":"publisher","first-page":"3124","DOI":"10.1007\/s10439-016-1596-4","volume":"44","author":"H Posada-Quintero","year":"2016","unstructured":"Posada-Quintero, H., Florian, J. P., Orjuela-Ca\u00f1\u00f3n, \u00c1., Aljama-Corrales, T., Charleston-Villalobos, S., & Chon, K. H. (2016). Power spectral density analysis of electrodermal activity for sympathetic function assessment. Annals of Biomedical Engineering, 44(10), 3124\u20133135. https:\/\/doi.org\/10.1007\/s10439-016-1596-4","journal-title":"Annals of Biomedical Engineering"},{"issue":"4","key":"3097_CR59","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1109\/TBME.2016.2631481","volume":"64","author":"HF Posada-Quintero","year":"2017","unstructured":"Posada-Quintero, H. F., Rood, R. J., Noh, Y. S., & Chon, K. H. (2017). Dry carbon\/salt adhesive electrodes for recording electrodermal activity. IEEE Transactions on Biomedical Engineering, 64(4), 1234\u20131242. https:\/\/doi.org\/10.1109\/TBME.2016.2631481","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"3097_CR60","volume-title":"Proceedings of the Third Workshop on Mining Temporal and Sequential Data","author":"Ratanamahatana","year":"2005","unstructured":"Ratanamahatana, & Keogh, E. (2005). Everything you know about dynamic time warping is wrong. Proceedings of the Third Workshop on Mining Temporal and Sequential Data. IEEE."},{"issue":"1","key":"3097_CR61","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s12938-025-01353-0","volume":"24","author":"H Reithe","year":"2025","unstructured":"Reithe, H., Marty, B., Torrado, J. C., F\u00f8rsund, E., Huseb\u00f8, B. S., & Erdal, A. (2025). Cross-evaluation of wearable data for use in Parkinson\u2019s disease research: A free-living observational study on Empatica E4, Fitbit Sense, and Oura. BioMedical Engineering OnLine, 24(1), 22. https:\/\/doi.org\/10.1186\/s12938-025-01353-0","journal-title":"BioMedical Engineering OnLine"},{"key":"3097_CR62","doi-asserted-by":"publisher","unstructured":"Romero, F. P., Romaguera, L. V., V\u00e1zquez-Seisdedos, C. R., Filho, C. F. F. C., Costa, M. G. F., & Neto, J. E. (2018). Baseline wander removal methods for ECG signals: A comparative study. arXiv.\u00a0https:\/\/doi.org\/10.48550\/arXiv.1807.11359","DOI":"10.48550\/arXiv.1807.11359"},{"key":"3097_CR63","doi-asserted-by":"publisher","unstructured":"Ronca, V., Martinez-Levy, A. C., Vozzi, A., Giorgi, A., Aric\u00f2, P., & Capotorto, R. (2023). A comparison between Fitbit Sense, Empatica E4 and Shimmer GSR3+ in measuring electrodermal activity and photoplethysmographic signals. Sensors, 23(13), 5847. https:\/\/doi.org\/10.3390\/s23135847","DOI":"10.3390\/s23135847"},{"issue":"2","key":"3097_CR64","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1016\/j.biopsycho.2012.07.002","volume":"91","author":"WT Roth","year":"2012","unstructured":"Roth, W. T., Dawson, M. E., & Schell, A. M. (2012). Autonomic nervous system reactivity to positive and negative mood induction: The role of trait anxiety. Biological Psychology, 91(2), 256\u2013264. https:\/\/doi.org\/10.1016\/j.biopsycho.2012.07.002","journal-title":"Biological Psychology"},{"issue":"5","key":"3097_CR65","doi-asserted-by":"publisher","first-page":"561","DOI":"10.3233\/IDA-2007-11508","volume":"11","author":"S Salvador","year":"2007","unstructured":"Salvador, S., & Chan, P. (2007). Toward accurate dynamic time warping in linear time and space. Intelligent Data Analysis, 11(5), 561\u2013580. https:\/\/doi.org\/10.3233\/IDA-2007-11508","journal-title":"Intelligent Data Analysis"},{"issue":"5","key":"3097_CR66","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1515\/bmt-2012-0062","volume":"58","author":"A Schafer","year":"2013","unstructured":"Schafer, A., & Vagedes, J. (2013). Empirical comparison of signal quality indices for the automatic assessment of pulse wave signals. Biomedizinische Technik\/Biomedical Engineering, 58(5), 277\u2013285. https:\/\/doi.org\/10.1515\/bmt-2012-0062","journal-title":"Biomedizinische Technik\/Biomedical Engineering"},{"issue":"11","key":"3097_CR67","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1007\/s10916-020-01648-w","volume":"44","author":"AAT Schuurmans","year":"2020","unstructured":"Schuurmans, A. A. T., de Looff, P., Nijhof, K. S., Rosada, C., Scholte, R. H. J., & Popma, A. (2020). Validity of the Empatica E4 wristband to measure heart rate variability (HRV) parameters: A comparison to electrocardiography (ECG). Journal of Medical Systems, 44(11), 190. https:\/\/doi.org\/10.1007\/s10916-020-01648-w","journal-title":"Journal of Medical Systems"},{"issue":"2","key":"3097_CR68","doi-asserted-by":"publisher","first-page":"zpaf021","DOI":"10.1093\/sleepadvances\/zpaf021","volume":"6","author":"AM Schyvens","year":"2025","unstructured":"Schyvens, A. M., Peters, B., Van Oost, N. C., Aerts, J. M., Masci, F., & Neven, A. (2025). A performance validation of six commercial wrist-worn wearable sleep-tracking devices for sleep stage scoring compared to polysomnography. Sleep Advances, 6(2), zpaf021. https:\/\/doi.org\/10.1093\/sleepadvances\/zpaf021","journal-title":"Sleep Advances"},{"issue":"1","key":"3097_CR69","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41746-020-0288-7","volume":"3","author":"N Selvaraj","year":"2020","unstructured":"Selvaraj, N., Jaryal, A. K., Santhosh, J., Deepak, K. K., & Anand, S. (2020). Assessment of heart rate variability derived from wrist photoplethysmography in a heterogeneous patient population. npj Digital Medicine, 3(1), 1\u20139. https:\/\/doi.org\/10.1038\/s41746-020-0288-7","journal-title":"npj Digital Medicine"},{"issue":"4","key":"3097_CR70","doi-asserted-by":"publisher","first-page":"420","DOI":"10.3390\/s16040420","volume":"16","author":"SY Sim","year":"2016","unstructured":"Sim, S. Y., Koh, M. J., Joo, K. M., Park, Y. J., & Kim, J. (2016). Estimation of thermal sensation based on wrist skin temperatures. Sensors, 16(4), 420. https:\/\/doi.org\/10.3390\/s16040420","journal-title":"Sensors"},{"issue":"2","key":"3097_CR71","doi-asserted-by":"publisher","first-page":"e70004","DOI":"10.1111\/psyp.70004","volume":"62","author":"M Sinichi","year":"2025","unstructured":"Sinichi, M., Gevonden, M., & Krabbendam, L. (2025). Quality in question: Assessing the accuracy of four heart rate wearables and the implications for psychophysiological research. Psychophysiology, 62(2), e70004. https:\/\/doi.org\/10.1111\/psyp.70004","journal-title":"Psychophysiology"},{"key":"3097_CR72","doi-asserted-by":"publisher","first-page":"1710693","DOI":"10.3389\/fspor.2025.1710693","volume":"7","author":"CA Staunton","year":"2026","unstructured":"Staunton, C. A., Edholm, P., Ide, B. N., Ditroilo, M., & Wundersitz, D. (2026). PlayerLoad\u2122 and accelerometer-based metrics: Scientific evaluation and implications for athlete monitoring. Frontiers in Sports and Active Living, 7, 1710693. https:\/\/doi.org\/10.3389\/fspor.2025.1710693","journal-title":"Frontiers in Sports and Active Living"},{"key":"3097_CR73","doi-asserted-by":"publisher","first-page":"103118","DOI":"10.1016\/j.micpro.2020.103118","volume":"79","author":"T Steinmetzer","year":"2020","unstructured":"Steinmetzer, T., Knaflitz, M., & Tarabini, M. (2020). Analyzing gait symmetry with automatically synchronized wearable sensors. Microprocessors and Microsystems, 79, 103118. https:\/\/doi.org\/10.1016\/j.micpro.2020.103118","journal-title":"Microprocessors and Microsystems"},{"issue":"5","key":"3097_CR74","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1016\/j.ijinfomgt.2015.04.010","volume":"35","author":"N Sultan","year":"2015","unstructured":"Sultan, N. (2015). Reflective thoughts on the potential and challenges of wearable technology for healthcare provision and medical education. International Journal of Information Management, 35(5), 521\u2013526. https:\/\/doi.org\/10.1016\/j.ijinfomgt.2015.04.010","journal-title":"International Journal of Information Management"},{"issue":"13","key":"3097_CR75","doi-asserted-by":"publisher","first-page":"5005","DOI":"10.3390\/s22135005","volume":"22","author":"T Tanaka","year":"2022","unstructured":"Tanaka, T., Nambu, I., Maruyama, Y., & Wada, Y. (2022). Sliding-window normalization to improve the performance of machine-learning models for real-time motion prediction using electromyography. Sensors, 22(13), 5005. https:\/\/doi.org\/10.3390\/s22135005","journal-title":"Sensors"},{"issue":"1","key":"3097_CR76","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.artmed.2008.11.007","volume":"45","author":"P Tormene","year":"2009","unstructured":"Tormene, P., Giorgino, T., Quaglini, S., & Stefanelli, M. (2009). Matching incomplete time series with dynamic time warping: An algorithm and an application to post-stroke rehabilitation. Artificial Intelligence in Medicine, 45(1), 11\u201334. https:\/\/doi.org\/10.1016\/j.artmed.2008.11.007","journal-title":"Artificial Intelligence in Medicine"},{"issue":"2","key":"3097_CR77","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.pec.2015.09.013","volume":"99","author":"I Van Bruinessen","year":"2016","unstructured":"Van Bruinessen, I., van den Ende, I., Visser, L., & van Dulmen, S. (2016). The impact of watching educational video clips on analogue patients\u2019 physiological arousal and information recall. Patient Education and Counseling, 99(2), 243\u2013249. https:\/\/doi.org\/10.1016\/j.pec.2015.09.013","journal-title":"Patient Education and Counseling"},{"issue":"2","key":"3097_CR78","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.physbeh.2012.01.020","volume":"106","author":"M van Dooren","year":"2012","unstructured":"van Dooren, M., de Vries, G. J. J., & Janssen, J. H. (2012). Emotional sweating across the body: Comparing 16 different skin conductance measurement locations. Physiology & Behavior, 106(2), 298\u2013304. https:\/\/doi.org\/10.1016\/j.physbeh.2012.01.020","journal-title":"Physiology & Behavior"},{"issue":"7","key":"3097_CR79","doi-asserted-by":"publisher","first-page":"8804","DOI":"10.3390\/s130708804","volume":"13","author":"VT van Hees","year":"2013","unstructured":"van Hees, V. T., Gorzelitz, J., Dean Le\u00f3n, E. C., Eder, M., Pias, M., & Kinnunen, H. (2013). Optimal placement of accelerometers for the detection of everyday activities. Sensors, 13(7), 8804\u20138824. https:\/\/doi.org\/10.3390\/s130708804","journal-title":"Sensors"},{"issue":"2","key":"3097_CR80","doi-asserted-by":"publisher","first-page":"607","DOI":"10.3758\/s13428-019-01253-9","volume":"52","author":"HG van Lier","year":"2020","unstructured":"van Lier, H. G., Pieterse, M. E., Garde, A., Postel, M. G., de Haan, H. A., Vollenbroek-Hutten, M. M., Noordzij, M. L., & Hermens, H. J. (2020). A standardized validity assessment protocol for physiological signals from wearable technology: Methodological underpinnings and an application to the E4 biosensor. Behavior Research Methods, 52(2), 607\u2013629. https:\/\/doi.org\/10.3758\/s13428-019-01253-9","journal-title":"Behavior Research Methods"},{"key":"3097_CR81","first-page":"1","volume-title":"International Conference on Biomedical Electronics and Devices","author":"HG van Lier","year":"2021","unstructured":"van Lier, H. G., Pieterse, M. E., Garde, A., Postel, M. G., & Hermens, H. J. (2021). Criterion validation of an open-source wearable physiological monitoring platform. International Conference on Biomedical Electronics and Devices (pp. 1\u20138). SCITEPRESS. https:\/\/www.scitepress.org\/Papers\/2021\/106403\/106403.pdf"},{"issue":"22","key":"3097_CR82","doi-asserted-by":"publisher","first-page":"9061","DOI":"10.3390\/s23229061","volume":"23","author":"KS van Schooten","year":"2023","unstructured":"van Schooten, K. S., Pijnappels, M., Rispens, S. M., Elders, P. J. M., Lips, P., & van Die\u00ebn, J. H. (2023). Stepmatch-DTWBA: Person-specific template matching using dynamic time warping barycenter averaging for accurate step counting. Sensors, 23(22), 9061. https:\/\/doi.org\/10.3390\/s23229061","journal-title":"Sensors"},{"key":"3097_CR83","doi-asserted-by":"publisher","unstructured":"Vert, A., Weber, K. S., Thai, V., Turner, E., Beyer, K. B., Cornish, B. F., \u2026, & Christopher Wong, William E. McIlroy, and Karen Van Ooteghem. (2022). Detecting accelerometer non-wear periods using change in acceleration combined with rate-of-change in temperature. BMC Medical Research Methodology, 22(1), 147. https:\/\/doi.org\/10.1186\/s12874-022-01633-6","DOI":"10.1186\/s12874-022-01633-6"},{"issue":"1887","key":"3097_CR84","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1098\/rsta.2008.0232","volume":"367","author":"A Voss","year":"2009","unstructured":"Voss, A., Schulz, S., Schroeder, R., Baumert, M., & Caminal, P. (2009). Methods derived from nonlinear dynamics for analysing heart rate variability. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 367(1887), 277\u2013296. https:\/\/doi.org\/10.1098\/rsta.2008.0232","journal-title":"Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences"},{"key":"3097_CR85","volume-title":"Dynamic time warping (DTW) (Version 2.2) [MATLAB Central File Exchange]","author":"Q Wang","year":"2023","unstructured":"Wang, Q. (2023). Dynamic time warping (DTW) (Version 2.2) [MATLAB Central File Exchange]. MathWorks. https:\/\/www.mathworks.com\/matlabcentral\/fileexchange\/43156-dynamic-time-warping-dtw"},{"key":"3097_CR86","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1038\/s41597-025-04453-7","volume":"12","author":"X Wang","year":"2025","unstructured":"Wang, X., Zhang, L., Chen, W., Liu, Y., & Zhao, M. (2025). WF-PPG: A wrist\u2013finger dual-channel dataset for studying the effects of contact pressure on PPG waveform morphology. Scientific Data, 12, 453. https:\/\/doi.org\/10.1038\/s41597-025-04453-7","journal-title":"Scientific Data"},{"issue":"2","key":"3097_CR87","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1111\/j.1467-2494.2006.00354.x","volume":"29","author":"K Wilke","year":"2007","unstructured":"Wilke, K., Martin, A., Terstegen, L., & Biel, S. (2007). A short history of sweat gland biology. International Journal of Cosmetic Science, 29(2), 169\u2013182. https:\/\/doi.org\/10.1111\/j.1467-2494.2006.00354.x","journal-title":"International Journal of Cosmetic Science"},{"issue":"5","key":"3097_CR88","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1016\/j.compbiomed.2006.06.014","volume":"37","author":"L Xu","year":"2007","unstructured":"Xu, L., Zhang, D., Wang, K., Li, N., & Wang, X. (2007). Baseline wander correction in pulse waveforms using wavelet-based cascaded adaptive filter. Computers in Biology and Medicine, 37(5), 716\u2013731. https:\/\/doi.org\/10.1016\/j.compbiomed.2006.06.014","journal-title":"Computers in Biology and Medicine"},{"key":"3097_CR89","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.ijmedinf.2017.09.013","volume":"108","author":"M Zhang","year":"2017","unstructured":"Zhang, M., Luo, M., Nie, R., & Zhang, Y. (2017). Technical attributes, health attribute, consumer attributes and their roles in adoption intention of healthcare wearable technology. International Journal of Medical Informatics, 108, 97\u2013109. https:\/\/doi.org\/10.1016\/j.ijmedinf.2017.09.013","journal-title":"International Journal of Medical Informatics"},{"issue":"7","key":"3097_CR90","doi-asserted-by":"publisher","first-page":"2119","DOI":"10.3390\/s24072119","volume":"24","author":"Y Zhou","year":"2024","unstructured":"Zhou, Y., Nematallah, H., & Rajan, S. (2024). Quantitative analysis of mother wavelet function selection for wearable sensors-based human activity recognition. Sensors, 24(7), 2119. https:\/\/doi.org\/10.3390\/s24072119","journal-title":"Sensors"},{"key":"3097_CR91","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1109\/CIC.2003.1291139","volume-title":"Computers in Cardiology 2003","author":"W Zong","year":"2003","unstructured":"Zong, W., Moody, G. B., & Jiang, D. (2003). An open-source algorithm to detect onset of arterial blood pressure pulses. Computers in Cardiology 2003 (pp. 259\u2013262). IEEE. https:\/\/doi.org\/10.1109\/CIC.2003.1291139"}],"container-title":["Behavior Research Methods"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.3758\/s13428-026-03097-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.3758\/s13428-026-03097-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.3758\/s13428-026-03097-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T14:11:23Z","timestamp":1785334283000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.3758\/s13428-026-03097-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,16]]},"references-count":91,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["3097"],"URL":"https:\/\/doi.org\/10.3758\/s13428-026-03097-8","relation":{},"ISSN":["1554-3528"],"issn-type":[{"value":"1554-3528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,16]]},"assertion":[{"value":"11 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Board of Hospital Cl\u00ednic de Barcelona (protocol code HCB\/2021\/104).","order":1,"name":"Ethics","label":"Ethics approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was obtained from all subjects involved in the study.","order":2,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The manuscript does not include identifiable personal data. Therefore, this section does not apply to our manuscript.","order":3,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.","order":4,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"239"}}